Intelligent Addressable System Features Conventional System Features Fire Extinguishant Control Panel
◗ Modular structure from 1 loop to 8 loops ◗ 2, 4, 8 and 16 zone capacity ◗ 4 detection zones, 1 extinguishant zone
◗ Model option with thermal printer ◗ Microprocessor controlled ◗ Extinguishant-related front panel LEDs and
LCD screen provide full system information
◗ Microprocessor controlled ◗ Stable sensitivity
◗ Delay and extinguishant time can be
◗ 1000 event log memory ◗ PCB protection against to humidity and adjusted
corrosion
◗ Loop polling in 7.5 sec ◗ Selenoid valve or actuator can be connected
to the extinguishing output
◗ Communication interrupt for fast �ire alarm
detection in 1.5 sec
* IACS Member Classi�ication Societies
◗ Up to 1000 cause-effect scenarios can be
created for each panel
KT.005 Rev.No:0
Perfect Design
4
with Modular
Structure...
ML-1248.P/M
Fire Alarm Control Panel
KT.005 Rev.No:0
15
ML-1238/M
Fire Alarm Control Panel
◗ Surface mount technology ◗ Input/output modules can be connected to ◗ 1000 event log and programmable zones
panel memory
◗ The key is needed for entry to panel menu
◗ User friendly and aesthetic design and easy ◗ Communication interrupt for fast �ire
◗ Protection from electromagnetic interference installation detection in 1.5 sec
◗ Supervised peripheral devices, extension ◗ Advanced parametric arrangement options ◗ 1000 automation scenarios can be created for
cards (power supply, loop extensions, for input/output devices each panel
printer..)
◗ Top priority of �ire alarm indication, different ◗ Up to 64 panels and/or repeater panels can be
◗ Real time clock buttons for �ire and other events, categorical assembled with CAN protocol
classi�ication due to events
◗ 4 programmable supervised remote control ◗ Day and night mode, pre-alarm,
inputs contamination warning into a network
KT.005 Rev.No:0
Graphic
6
Monitoring and
Control...
◗ Integration of building projects into the ML-1280/M 7” TFT Mimic Panel via SD card
KT.005 Rev.No:0
7
Ability to monitor graphically for all Maxlogic �ire alarm system small site and big site applications. 7’’ TFT Mimic Panel contains stylish
exterior design and Surface Mount Technology (SMT) production techniques.
◗ Possible sending information Alarm / Alarm Silence / Reset to all panels in network
◗ Quick intervention
KT.005 Rev.No:0
Perfect
8
Software
Communication…
GCU Panel
GCU MODELS
Abilities…
KT.005 Rev.No:0
Intelligent
10 Integration of
Advanced Systems...
KT.005 Rev.No:0
Announce System
Main
Control Unit
Maxlogic ML-123X Series Intelligent Addressable Fire Alarm Panel
Loop Emergency
Line Signal Input
Unit
Speaker
1 Announce
Line Programmable Alarm/Alert Outputs
8 16 64 Emergency
Message Unit
11
Speaker
Channel Selector
Announce /
Alarm Speaker
Matrix Panel PreAmplifier
4 8 32 Sound
Announce Inputs Outputs
Amplifier
32
Speaker
Amplifier
MODELS
KT.005 Rev.No:0
Managing
12 and Controlling
in Your Hands...
KT.005 Rev.No:0
Dry Contact Input / Output Modules
Modules are loop-powered and can be programmed to The module has one relay output with voltage-free,
operate in cause-effect scenarios. External systems bipolar contact max. load of 30V DC, 1A . The relay can
can be monitored by switch monitor inputs and can be operate as normally open or normally close.
controlled by relay outputs within �ire automation.
The models have SCI, internal short circuit isolator, in
Switch monitor inputs are used for monitoring case of short circuit events, isolates the line.
external dry switch relay output. Switches have
normally open and normally close operate features.
In case of changing of switch position, event type that
is detected by panels can be determined by users.
13
Zone monitoring Inputs are used to monitor the With SCI models, internal short circuit isolator, in case
conventional type detectors and manual call points. of short circuit events, isolates the line.
In case of change of Input status, events type that are
detected by panel can be determined by users.
MODELS MODELS
KT.005 Rev.No:0
Aesthetic
14 and Technologic
Genius...
ML-1101/M ML-1102/M
Addressable loop powered Addressable loop-powered ◗ Compatible with EN 54-3 and EN 54-23
base sounder base sounder beacon
◗ Specially designed for indoor use
◗ Loop-powered
◗ Able to integrate into the cause effect ◗ Adjustable different 32 voice tone 15
ML-1410.SCI/M scenarios options
Intelligent addressable
system sounder with
◗ Stable sensitivity ◗ IP33 / IP65 high protection class
short circuit isolator
options
◗ Suitable for outdoor use
MODELS MODELS
ML-1490.SCI/M Product Code Description Product Code Description
Intelligent ML-1410/M* Intelligent addressable system sounder ML-1460/M* Intelligent addressable system sounder & beacon,
Addressable System ML-1410.SCI/M* Intelligent addressable system sounder with weatherproof (IP33)
Sounder & Beacon, short circuit isolator ML-1460.SCI/M* Intelligent addressable system sounder & beacon,
Weatherproof (IP65), ML-1420/M* Intelligent addressable system beacon weatherproof (IP33), short circuit isolator
Short Circuit Isolator ML-1420.SCI/M* Intelligent addressable system beacon ML-1470/M* Intelligent addressable system sounder,
with short circuit isolator weatherproof (IP65)
ML-1430/M* Intelligent addressable system sounder & beacon ML-1470.SCI/M* Intelligent addressable system sounder,
ML-1430.SCI/M* Intelligent addressable system sounder & beacon weatherproof (IP65), short circuit isolator
with short circuit isolator ML-1480/M* Intelligent addressable system beacon,
ML-1440.SCI/M ML-1440/M* Intelligent addressable system sounder, weatherproof (IP65)
Intelligent Addressable weatherproof (IP33) ML-1480.SCI/M* Intelligent addressable system beacon,
System Sounder, ML-1440.SCI/M* Intelligent addressable system sounder, weatherproof (IP65), short circuit isolator
Weatherproof (IP33), weatherproof (IP33), short circuit isolator ML-1490/M* Intelligent addressable system sounder & beacon,
Short Circuit Isolator ML-1450/M* Intelligent addressable system beacon, weatherproof (IP65)
weatherproof (IP33) ML-1490.SCI/M* Intelligent addressable system sounder & beacon,
ML-1450.SCI/M* Intelligent addressable system beacon, weatherproof (IP65), short circuit isolator
weatherproof (IP33), short circuit isolator
ML-1730.SCI/M
Intelligent addressable system
manual call point weatherproof ◗ Compatible with EN 54-11 / EN 54-17 ◗ Transparent protection cover
(IP67) resettable, ML-1710/M
short circuit isolator Intelligent addressable system
manual call point, resettable ◗ Surface mount or �lush mount ◗ Easy resettable
MODELS MODELS
Product Code Description Product Code Description
ML-1101/M* Addressable loop powered base sounder ML-1710/M* Intelligent addressable system manual call point,
ML-1102/M* Addressable loop-powered base sounder resettable
beacon ML-1710.SCI/M* Intelligent addressable system manual call point,
ML-0141/M Mounting base c/w buzzer resettable, short circuit isolator
ML-1730/M* Intelligent addressable system manual call point,
weatherproof (IP67), resettable
* Marked products have the Turkish Loyd certi�icate as well.
ML-1710.SCI/M ML-1730.SCI/M* Intelligent addressable system manual call point,
Intelligent addressable system weatherproof (IP67), resettable, short circuit
manual call point, resettable, isolator
short circuit isolator ML-0710 Transparent protection cover
KT.005 Rev.No:0
Excellent
Harmony of
16
Hardware and
Software...
◗ Compatible with EN 54-5, EN 54-7 ◗ Remote indicator output ◗ Compatible with ML-0121/M series
and EN 54-17 surface mounting back box
◗ Optional short circuit isolator module
◗ Microprocessor controlled ◗ Easy mounting and dismounting
◗ RY LED glows Red in case of �ire, Yellow
◗ Twin �ire alarm indicators for 360° in case of pollution and fault conditions
viewing
ML-1110.SCI/M ML-1140.SCI/M
Optical smoke detector Multisensor detector
with short circuit isolator with short circuit isolator
ML-1130.SCI/M
Heat detector
with short circuit isolator
KT.005 Rev.No:0
Intelligent Addressable Optical Smoke
Detector, with short circuit isolator
17
PANEL MODELS
KT.005 Rev.No:0
Intelligent
18 and
Powerful...
ML-05110/M
SMPS Power Supply
MODELS
KT.005 Rev.No:0
Designed
for Harsh
19
Environment
Conditions…
ML-0121/M
Surface Mounting
Back Box
MODELS
KT.005 Rev.No:0
Keep Your
Eyes On The
Heights...
20
KT.005 Rev.No:0
Re�lective Beam Type Smoke Detector 21
Maxlogic beam type smoke detector Re�lective beam type smoke detector Detectors detect the light obstruction
consists of 2 parts; receiver and consists 2 parts as a receiver/transmitter percentage caused by the smoke created by
transmitter. They should be installed as unit and re�lector. Unit and re�lector should �ire.
facing each other between the distance of be mounted as facing each other, distance
5-100m. is 5-35 meters with 1 re�lector and 5-50
meters with using 4 re�lectors.
◗ Intelligent addressable and conventional ◗ With beam type smoke detector 1500 m2, ◗ Ability to adjust itself to polluted and dirty
models with re�lective beam type smoke detector environment
750 m2 protection area
◗ Short circuit isolator models ◗ Three sensitivity levels can be easily adjusted
◗ Easy programming buttons
◗ Receiver-Transmitter or re�lective models ◗ Continuous control of communication
◗ LED indicators for power, �ire and fault against the faults
◗ 2 digit numerical screen for easy conditions
commissioning and setup
DETECTOR MODELS
KT.005 Rev.No:0
Conventional
System That Can
Work In a Network...
22
◗ Compatible with EN 54-2 and EN 54-4 ◗ Delay can be assigned to zones and
sounders
◗ 2, 4, 8 and 16 zones
◗ Up to 1000 events log memory
◗ Up to 32 repeater panels and/or �ire
panels assembled into a network with ◗ Relay module 8-way (provides zonal
using repeater panel relay output)
KT.005 Rev.No:0
SOUNDER LINE
.
.
. SOUNDER LINE
23
MGRP-64/M MG-2610
Conventional Repeater Panel MGRP-64 Software
ADDRESS: 1
◗ Fire and fault are monitored through zone ◗ Zones can be tested with one-man, through ◗ Stable sensitivity
LEDs and piezoelectric buzzer zone test feature
◗ Protection from electromagnetic interferences
◗ Sounder, fault and �ire relay outputs ◗ Speci�ic zones and/or sounder outputs can
be disabled thorugh zone disable and
sounder disable features
KT.005 Rev.No:0
New Perspective
at Detection
Technology…
24
◗ Compatible with EN 54-5 and ◗ Compatible with ML-0140/M series ◗ Compatible with ML-0121/M series
EN 54-7 standards mounting base c/w relay surface mounting back box
◗ Twin LED indicators for 360° view ◗ Compatible with ML-0141/M series ◗ 2 pcs red LEDs (the light �lashes
mounting base c/w buzzer continuously in case of �ire-situation,
◗ Microprocessor controlled the light �lashes once per 8 second in
◗ Remote indicator output case of normal-status, the light �lashes
twice per 8 second in case of
fault-status)
KT.005 Rev.No:0
Conventional Photo-Electric Smoke Detector
MODELS
26
Conventional Sounder Conventional Beacon / Sounder & Beacon Conventional Sounder / Beacon /
Sounder & Beacon, Weatherproof
Maxlogic series conventional sounders provide Maxlogic series conventional beacon / sounder
stable performance in indoor applications and & beacon generates audible and visual signal, Maxlogic series conventional sounders are
are compatible with all conventional panels. in addition to these features. weather-proof audible warning devices and
suitable for outdoor use.
◗ Compatible with EN 54-3 ◗ Compatible with EN 54-3 and EN 54-23
◗ Compatible with EN 54-3 and EN 54-23
◗ Surface mount or �lush mount ◗ Adjustable different 32 voice tone options
◗ Adjustable different 32 voice tone options
◗ Adjustable different 32 voice tone options ◗ Adjustable �lash frequency and coverage area
◗ Adjustable �lash frequency and coverage area
◗ Low or high voice power control ◗ White, strong LED �lasher
◗ IP33 / IP65 high protection class options
◗ Microprocessor controlled
◗ Suitable for outdoor use
◗ Compatible with all conventional �ire alarm Product code Description Product codeDescription
panels ML-2710/M * Manual call point, resettable ML-2410/M * Conventional sounder
ML-0710 Transparent protection cover ML-2420/M * Conventional beacon
◗ Transparent protection cover ML-0314/M Sounder expansion panel ML-2430/M * Conventional sounder & beacon
SMOKE Smoke detector tester / sabre ML-2440/M * Conventional sounder, weatherproof (IP33)
SABRE 01-001 ML-2450/M * Conventional beacon, weatherproof (IP33)
ML-2460/M * Conventional sounder & beacon,
* Marked products have the Turkish Loyd certi�icate as well. weatherproof (IP33)
ML-2470/M * Conventional sounder, weatherproof (IP65)
ML-2480/M * Conventional beacon, weatherproof (IP65)
ML-2490/M * Conventional sounder & beacon,
weatherproof (IP65)
KT.005 Rev.No:0
Reliable Choice
for Exproof
Applications...
28
Gas Alarm Control Panel 4 Channel
The modern design panel, offering advanced programmability and high performance with its 4 channels, is widely applicable for industrial
use. Panels offer many features to integrate to automations applications.
KT.005 Rev.No:0
ML-2490/M Xgard Type 5
Conventional sounder & beacon, (Suitable for �lammable gases)
weatherproof (IP65) ATEX Ex II 2G, EExd IIC T6
Irmax
IR hidrocarbon gas
detector
Z 728.F
Zener barrier HAZARDOUS AREA
29
MG-400/M
Gas Alarm Control Panel,
4 Channel
◗ Compatible with Industrial gas detectors and ◗ Channel measurement unit can be chosen ◗ Latching/non-latching sounder outputs
4-20 mA converter from “%LEL”, “PPB”, “PPM”, “%VOL” or “GAS”
◗ Compatible with two and three wire
◗ Desired channels can be disabled, sounder ◗ High and low alarm warnings can be selected detectors
outputs and relays can be tested, gas according to ambient gas density.
detectors can be zeroed and calibration can ◗ Sink and source operating selection for
be done via panel. ◗ Latching/non-latching relay outputs channels
◗ It is possible to enter zone location names for ◗ Relays can be set as NO or NC ◗ Password access and remote control for
panels and detectors protection against unauthorized
intervention
SANTRAL
MODELS
KT.005 Rev.No:0
Perfect
Extinguishing
Automation...
30
◗ Compatible with EN 12094-1, EN 54-2
and EN 54-4 standards
ML-322/M
Fire extinguishing control panel ML-3313/M
Extinguishing status indicator unit,
with extinguishing status switch
and releasing but
KT.005 Rev.No:0
◗ Adjustable �irst level delay time to sounders ◗ Supervized extiguishing output, second level ◗ Event log can be monitored via PC software
sounders, gas release output
◗ Adjustable delay time to detection zones ◗ Sending event log via RS-232 to PC or printer
◗ Extinguishing mode can be changed remotely
◗ Con�igurable delay and extinguishing time with extinguishing status key input ◗ There are two extinguishing operating types;
automatic and manual or manual only
◗ Non-latching zone option ◗ Fire and fault relays
◗ Detection zones can be tested or disabled, 1.
◗ Countdown clock until the starting of ◗ Dry contact relay output for �ire and fault and 2. Level relay output, extinguishing
extinguishing output and extinguishing abort button can be
◗ Dry or energized contact options for outputs disabled
◗ Fire and fault LEDs for each detection zone
◗ Favorable structure for integration with ◗ Inputs and outputs of panel, inputs and
◗ Supervised zone detection inputs, mechanical systems outputs of expansion module can be
extinguishing hold input, extinguishing programmed via special PC software.
abort input, extinguishing activation input, ◗ Cross-zone operation can be selected to be 31
Possibility of assigning gas active, remote
low pressure input. active/passive via PC software alarm, remote reset and many more features
to the inputs
◗ Real time clock ◗ Up to 1000 events log memory
KT.005 Rev.No:0
www.mavili.com.tr/en
Follow us...
.../mavilielektronikglobal
Mavili Elektronik Tic. ve San. A.S. reserves the right to change the design or speci�ication of these products without notice. Mavili Elektronik Tic. ve San. A.Ş. is free to decide whether to supply or not the products to the market. Images
represented in the catalog are for reference. Mavili Elektronik Tic. ve San. A.Ş. reserves the right of each product in the catalog. Rights reserved works cannot be copied, quoted, published or used elsewhere without the consent of the owner.
2020/V0