Professional Documents
Culture Documents
01 MGC3000speed Governor User Manual PDF
01 MGC3000speed Governor User Manual PDF
01 MGC3000speed Governor User Manual PDF
用户手册
User Manual
长江三峡能事达电气股份有限公司
Three Gorges Nengshida Electric Co.,Ltd.
第一章
Chapter I
概述
General
1-1
概述 General
1. 概述 ..................................................................................................................... 3
GENERAL .................................................................................................................. 3
Content ....................................................................................................................................... 3
Purpose....................................................................................................................................... 3
Chapters ..................................................................................................................................... 4
1-2
1. 概述
General
1.1 手册的内容
Content
《调速器用户手册》旨在向用户介绍我公司调速器的工作原理、组成单元和功能,
设备安装、设备调试以及设备日常使用中的维护方法等,以便于用户更好地使用我公司
的产品。
The User Manual for Speed Governor is aimed to give an introduction of our speed
governor in terms of the working principle, components, functions, installation, debugging
and maintenance in daily application, helping customers have a better understanding of our
products.
1.2 手册的用途
Purpose
了解调速器安装和运行操作中安全注意事项。
To learn the safety information on the installation and operation of speed governor.
掌握正确的设备操作和设备维护方法。
To learn how to operate and maintain the equipment.
熟悉调速器的技术资料。
To get familiarized with the technical documents on the speed governor.
1.3 手册的使用范围
Scope of Application
手册的使用者 本手册面向调速器的安装、运行维护人员。从事这些工作的人员
需具备足够的机械、电气工程专业知识和相关经验。
Users: for personnel to install, operate and maintain the speed governor. The personnel
involved there shall have enough knowledge in mechanical, electrical engineering and so
on, as well as relevant working experience.
手册的使用范围 本手册随设备一起发货,与相应的设备配套使用,不可用来指
1-3
概述 General
导其它产品的使用。
Scope of Application The Manual is enclosed with the equipment and provided for the
corresponding equipment instead of other products.
手册的解释权 长江三峡能事达电气股份有限公司拥有对手册的最终解释权。
Power of Interpretation Three Gorges Nengshida Electric Co.,Ltd. reserves the
power of final interpretation for the Manual.
1.4 手册章节
Chapters
第一章 概述
Chapter I General
介绍整套手册包含的主要内容、用途和使用范围。
To introduce the main contents, purposes and scope of application of the whole manual.
第二章 调速器基本原理和设备特性
Chapter II Basic Principle & Eqiuipment Features
介绍调速系统基本工作原理和调速系统设备的工作特性。
To introduce the basic working principle and features of the speed governor.
第三章 调速器电气图纸读图说明
Chapter III Interpretation of Electrical Drawings for Speed Governor
介绍调速器原理图的读图方法。
To introduce the drawing interpretation methods for Speed Governor Schematic Diagram.
第四章 调速器功能说明
Chapter IV Functions of Speed Governor
介绍调速器的基本功能、操作方式,工况和流程管理,以及 PID 调节规律等。
To introduce basic functions, operation modes, working conditions, process management
and regular patterns for PID regulation, etc.
第五章 调速器试验规程
Chapter V Test Code for Speed Governor
介绍调速器出厂试验和现场试验必须进行的试验项目、步骤和检验标准。
To introduce the necessary test items, steps and criteria for delivery and field tests on
speed governor.
1-4
概述 General
第六章 调速器人机界面
Chapter VI Human Machine Interface (HMI) for Speed Governor
介绍调速器人机界面上各个页面功能,参数的物理意义、设置和修改办法。
To introduce each page function for speed governor HMI as well as the physical
significance, setup and modification methods of parameters.
第七章 调速器柜体和传感器安装
Chapter VII Installation of Speed Governor Cabinet and Sensors
介绍调速器的储存、运输和安装说明。
To introduce the storage, transportation and installation of speed governor.
第八章 调速器运行操作说明
Chapter VIII Operation of Speed Governor
介绍调速器在日常运行操作方法,以及这些操作的定义。
To introduce the daily operation methods of speed governor and the definition of these
operations.
第九章 调速器维护及故障处理
Chapter IX Maintenance and Troubleshooting of Speed Governor
介绍调速器的维护保养办法,介绍常见故障的现象和排查办法。
To introduce the maintenance methods of speed governor, namely, common failures and
troubleshooting methods.
第十章 调速器通讯
Chapter X Communications of Speed Governor
介绍调速器通讯架构以及对外通讯的点表。
To introduce the communication architecture of speed governor and Point Tables for
External Communications
第十一章 调速器硬件手册控制器
Chapter XI Hardware Manual for Speed Governor: Controllers
介绍调速器微机控制器硬件各个模块的特性和接线定义。
To introduce the features and connection definition of each module for the
micro-controller of speed governor.
第十二章 调速器硬件手册 其它元件
Chapter XII Hardware Manual for Speed Governor: Other Elements
介绍调速器内其它重要部件,如:传感器、接近开关、自制板件等。
To introduce other key elements in speed governor, such as sensors, proximity switches
1-5
概述 General
1.5 重要提示
Important Notice
本手册用于产品介绍,不应理解为项目产品的实际性能。因此,产品与产品说明之
间会存在差异,应当以实际产品性能为准。
The Manual is used as a product description instead of real functions. Therefore, in case
of discrepancy between the product and the description, the real product functions shall
prevail.
本手册的编制难免有疏漏,用户如发现任何错误,恳请及时通知我方以尽快校正。
An omission or mistake may occur during the preparation of the Manual. Please notify us
of any mistake for timely updates.
1.6 制造商地址
Manufacturer's Address:
◆ 制造厂名称:长江三峡能事达电气股份有限公司
◆ Name: Three Gorges Nengshida Electric Co., Ltd.
◆ 制造厂地址:武汉市洪山区书城路 36 号
◆ Address: No. 36, Shucheng Road, Hongshan District, Wuhan
◆ 传真:027-50248889
◆ Fax: 027-50248889
◆ 电话:027-50248888
◆ Tel: 027-50248888
1-6
第二章
Chapter II
调速器基本原理和设备特性
2-1
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2.调速器基本原理和设备特性 ................................................................................... 4
2-3
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2.调速器基本原理和设备特性
2.1 调速系统原理介绍
水轮机调速系统由水轮机控制系统和被控制系统组成,方框内即为调速系统。
The turbine governing system consists of the turbine control system and the controlled
system, with the governing system indicated in the block.
水轮机控制系统 用来检测被控参量(转速、流量、水位、功率等) 与给定参量
的偏差,并将它们按照一定特性转换成主接力器行程偏差的一些设备所组成的系统。
Turbine control system a system composing of some equipment to detect the
deviations between the controlled parameters (rotational speed, flow rate, water level, power,
etc.) and the given parameters, converting them to the stroke deviation of the main
servomotor.
被控制系统 由控制系统控制的设备或物理量,包括水轮机、引水和泄水系
统,发电机以及所并入的电网。
Controlled system equipment or physical quantity controlled by the control system,
including turbines, diversion & drainage system, generators and the grid connected.
调速器通过外围的水位、频率、有功功率、导叶开度等传感器将机组的信息送至控
2-4
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
制器,控制器将这些信息与监控系统或者调速器面板上的控制指令进行综合,判断机组
当前的工作状态以及控制目标,并且将控制信号送至执行机构,将控制指令经过电液转
换之后最终作用在导叶(桨叶)接力器上,从而改变机组的运行状态,达到预期的控制
目标。
The speed governor sends the unit information to the controller via peripheral sensors for
water level, frequency, active power, guide vane opening, etc. The controller integrates the
information with the control commands by the monitoring system or the speed governor, to
verify the current working status and control object of the unit and send the control signal to
the actuating mechanism, with the control command finally acting on the guide vane (paddle)
servomotor upon an electro-hydraulic conversion to fulfill the expected control object.
◆ 机组在并网运行前,调速器将机组调整到额定转速运行,此时调速器的作用为
频率调节器,其调整目标是把机组频率调整到额定值。
◆ Before connecting to the grid, the speed governor regulates the unit to operate based
on a rated speed. The speed governor then works as a frequency regulator, aiming to regulate
the unit frequency into a rated value.
◆ 机组在并网运行后,机组向电网输出有功功率,调整水轮机的导叶开度/桨叶开
度能够改变机组输出的有功功率大小,此时调速器作为有功功率调节器工作,其调整目
标是把机组发出的有功功率调整到电网需求的数值。同时,调速器需要控制导叶开度,
使得机组发出的有功功率不超过机组的额定功率,所以调速器也作为机组有功功率限制
器使用。当电网频率波动超过设定值后,调速器自动变为频率调节器,将机组频率稳定
在机组额定值。
◆ Upon a grid-connected operation, the unit outputs the active power. It can regulate
the guide vane opening/paddle opening of the turbine to change the active power outputted by
the unit. The speed governor then works as an active power regulator, aiming to regulate the
active power by the unit to a required value by the grid. In the meantime, the speed governor
needs to control the guide vane opening, making the active power by the unit no more than the
rated power of the unit. Therefore, the speed governor also works as an active power limiter.
When the grid frequency fluctuation exceeds the set value, the speed governor automatically
2-5
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
converts to a frequency regulator, keeping the unit frequency stable at the rated value of the
unit.
MGC3000 系列调速器,是能事达电气根据多年的调速器设计制造经验,并结合我
国国情和水力发电行业特点开发的新产品。其采用了高性能双微机调节器作为控制核
心,搭配可靠性高的执行元件和全国产化具有完全自主知识产权的主配压阀,具有测频
精度高、响应速度快、静态耗油量低和安装维护简便等特点,已经开始广泛应用于国内
大、中型水电站中。
The MGC3000 Series speed governor, is a new product developed by NENGSHIDA
based on years of experience in the design and manufacturing of speed governors while
proceeding from the national conditions and industrial features of hydraulic electro generating.
It adopts high-performance dual microcomputer governor as the core controller, adopting
high-reliability actuator elements and the fully-localized main distributing valve of complete
independent intellectual property rights. It is featured with high frequency measurement
accuracy, fast response speed, low oil consumption in a static status and easy installation and
maintenance, etc, and has been widely applied to medium and large hydropower stations
around China.
2-6
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
◆ 供电需求 AC240V±15%,DC110V±15%
◆ Power demand AC240V±15%,DC110V±15%
◆ 调节柜功耗 1.5KVA @ AC240V,1.5kW@DC110V
2-7
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
◆ 自动/手动启停机组功能
◆ Auto/manual start/stop for the unit
2-9
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
◆ 自动/手动机组频率控制功能
◆ Auto/manual frequency control for the unit
◆ 自动/手动机组有功功率控制功能
◆ Auto/manual active power control for the unit
◆ 双微机控制器冗余功能
◆ Redundancy of dual microcomputer controller
◆ 紧急停机功能
◆ Emergency shutdown
◆ 调速器试验功能
◆ Test on speed governor
◆ 模拟量校准和死区整定功能
◆ Analog calibration and dead-band setting
◆ 调速系统故障自诊断和报警功能
◆ Self-Diagnosis and alarming for failures in speed governor
◆ 一次调频功能
◆ Primary frequency modulation
2.5 调速器电气原理概述
2-10
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2-11
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
外通讯端口。
◆ Communication links Communications between the internal equipment
of the speed governor adopt a serial port or Ethernet, preserving an external communication
port.
2-12
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2-13
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
◆ 输入电源交直流互为备用。
◆ The alternating current and direct current for the input power source are standby for
each other.
◆ 内部电源组成:开关电源交叉冗余合成控制和公共 DC24V 电源,其 DC24V 电
源与外部电源供电电源为完全隔离,保证调速系统内部电源可靠性。
◆ Composition of internal electrical power supply: combined control of the cross
redundancy of the switching power supply and common DC 24V power supply, with
the DC 24V power supply completely isolated from the external power supply
2-14
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
source, ensuring the internal reliability of the power supply for the governing
system.
◆ 双机实现完全独立供电,任何一套微机控制器出现电源故障,不影响另外一套
微机控制器正常运行;即能做到保证一套正常运行的前提下,切除备用机电源,
方便检修运行人员维护检查及故障排除。
◆ The dual-controller system can realize a completely-independent power supply. In
case a power failure occurs to any one of the micro-controllers, the other one can
still work normally with no impacted exerted. That is, when one controller works
well, it is convenient for the maintenance staff to conduct maintenance and
troubleshooting while the standby controller is powered off.
◆ 辅助电源 AC240V 为风扇散热、检修调试插座、柜内照明和柜内除湿等辅助功
能供电。
◆ The auxiliary power supply, AC 240V, is used for such auxiliary functions as heat
elimination of fans, socket inspection & debugging, in-cube illumination and in-cube
dehumidification, etc.
Power supply for emergency shutdown circuit of MGC3000 series speed governors
2-15
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
◆ 双微机控制器冗余为热备冗余,主用机工作的同时,备用机实时采集和处理数
据以及故障报警处理。
◆ The dual-microcomputer controller redundancy is of hot spared redundancy, while
the host machine is working, the standby acquires and processes the data in real time
and give a failure alarming.
◆ 调速器对外控制输出仅仅在主用机上进行,备用机内部采集及处理数据,但不
参与控制输出,备用机的控制数据体现在人机界面数据信息页面上。
◆ The external control output of the speed governor is only conducted by the host
machine, and the standby acquires and processes the data internally without
participating in the control output. The control data by the standby can be displayed
on the data information page of HMI.
◆ 双机均有独立的工作电源,任何一套电源故障都不会影响调速系统正常运行。
◆ The dual controllers both have an independent operational power supply; a power
failure in any one of the two sets can exert no impact on the normal operation of the
governing system.
◆ 备用机自动判断调速器所处于状态,备用机切换至主用时,维持系统工况不变。
◆ The standby controller can automatically determine the status of the speed governor.
When the standby switches over to the host controller, the working conditions of the
system keep unchanged.
◆ 双机切换无扰动:双微机为热备冗余,切换前后调速器状态及工况保持不变。
2-16
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2.8.1 RS232/485 接口
RS232/485 port
2-17
调速器基本原理和设备特性
Basic Principle & Equipment Features of Speed Governors
2.8.2 以太网接口
Ethernet port
※MGC3000 系列调速器的通讯细节请参考本手册第十章《调速器通讯》
Please refer to Chapter X Communications of Speed Governor in this Manual for details about
MGC3000 series speed governors.
2-18
第三章
Chapter III
调速器电气图纸读图说明
Interpretation of Electrical
Drawings for Speed
Governors
3-1
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.调速器电气图纸读图说明 ...................................................................................... 2
3.1 概述 ...................................................................................................................................... 2
General ...................................................................................................................................... 2
3-1
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.调速器电气图纸读图说明
3.1 概述
General
电气图纸中表明了电气控制部分主要硬件的规格和参数。阅读本章的目的在于能够
从电气图纸中快速地找到各个硬件及其连接电路,熟悉电气控制部分的组成和更快地定
位故障。
The electrical drawings indicate the specifications and parameters for the main hardware
of electrical controllers. The purpose of reading this Chapter is: to rapidly find each hardware
and its connecting circuit in the electrical drawings, getting familiarized with the composition
of the electric controllers and locating the failures more rapidly.
电气图纸包含以下几个内容:
The electrical drawings cover the following contents:
第一部分 封面
Part I Cover
第二部分 目录
Part II List
第三部分 系统原理图
Part III System Schematics
第四部分 电气接线原理图纸
Part IV Electrical Wiring Schematics
第五部分 端子图和配线表
Part V Terminal Diagram and Wiring Schedule
※注意 本章节旨在介绍我公司的 MGC 系列产品的电气图纸的读图方法,并不针对某
3-2
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
一个项目的电气原理图,故其中实例可能与实际产品的图纸有些许差别,应当以具体项
目的正式图纸为准。
※Note: this Chapter aims to introduce the methods for electrical drawing interpretation
of MGC Series products, not just for the electrical schematics of a certain project.
Therefore, Examples given in the Chapter may differ from the drawings for real
products in some way. The official drawing for the specific project shall prevail in this
case.
3.2 阅读图纸
Reading of Drawings
电气图纸页码规则:
Rules on sheet numbers for electrical drawings:
◆ 封面
◆ Cover Sheet
◆ 调速系统参数 第 001 页
◆ Parameters for Governing System Sheet 001
◆ 图纸目录 第 010 -011 页
◆ Drawing List Sheet 010 -011
◆ 原理总图部分 第 031 -032 页
◆ General Schematics Sheet 031 -032
◆ 元器件明细表 第 040 -050 页
◆ Element List Sheet 040 -050
◆ 标牌明细表 第 060 -080 页
◆ Detailed Nameplate List Sheet 060 -080
◆ 接线原理图纸 第 100 -900 页
◆ Wiring Schematics Sheet 100 -900
◆ 柜体布置图 第 1000 -1040 页
◆ Cabinet Arrangement Plan Sheet 1000 -1040
◆ 电调柜端子图 第 1200 -1251 页
◆ Electric Governing Cabinet Terminal Diagram Sheet 1200 -1251
3-3
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.2.1 封面
Cover Sheet
图 3.2.1-1 图纸封面(部分)
Figure 3.2.1-1 Cover Sheet (partial)
图纸封面所包含内容有:
The Cover Sheet includes:
◆ 图纸版本说明(供审图纸、正式图纸、生产图纸、竣工图纸);
◆ Note for drawing versions (drawings for approval, official drawings, production
drawings, as-built drawings);
3-4
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
◆ 图纸设计、校对与审查审核信息;
◆ Drawing designing, proofreading, checking and reviewing information;
◆ 图纸设计、校对与审查审核信息;
◆ information on persons to design, proofread, check and approve the drawings;
◆ 图纸适用的项目名称,设备名称及合同编号;
◆ Project names, equipment names and contract numbers applicable to the drawings;
◆ 图纸类型(电气原理图、生产配线图)。
◆ Drawing category (electrical schematics, production wiring diagrams).
3.2.2 调速器系统参数
图 3.2.2-1 调速系统参数(部分)
Figure 3.2. 2-1 Parameters for Speed Governors (partial)
调速系统参数页包含的内容有:
The Parameters for Speed Governors includes:
◆ PT 变比 说明本台设备适用的电压信号变比;
◆ PT transformation ratio to indicate the voltage signal transformation ratio
applicable to the equipment;
◆ CT 变比 说明本台设备适用的电流信号变比;
◆ CT transformation ratio to indicate the current signal transformation ratio
3-5
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.2.3 图纸目录
Drawing List
图 3.2.3-1 图纸目录(部分)
Figure 3.2. 3-1 Drawing List (partial)
图纸目录所包含内容有:
3-6
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.2.4 电气原理总图
图 3.2.4-1 电气原理总图(局部)
Figure 3.2. 4-1 General Electrical Schematics (partial)
3-7
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
测频单元 人工频
(齿盘/残压冗余) 率死区 比例
机组频率 f
Kf Ef KP
电气开限
微分
频率 KDS YPID
L
给定 1+ T1VS
电网频率 积分
KI
LCU跟踪网频 S
/频给选择
人工开度
Ey/p
LCU功率给定 /功率死区
方式选择 调速器工作
模式切换
功率脉冲 永态差
bp(e)p
给定 功率 值环节
功率设定值 给定
给定
开度
给定
调速器工作
模式切换
图 3.2.4-2 自动控制原理框图(局部)
Figure 3.2. 4- 2 Automatic Control Functional Bock Diagram (partial)
◆ 电气原理总图详见设备图纸 P031;
◆ Refer to Drawing P031 for General Electrical Schematics;
电气原理总图反映了调速器的电气控制配置、电气连接方式以及说明,包含有:
The General Electrical Schematics indicate the electric control setup, electrical wiring mode
and related notes for speed governors, including:
① 控制器部分的组成
Composition of controllers
② 输入输出信号来源去向
Sources and whereabouts of I/O signals
③ 频率信号来源和测频回路的组成
Source of frequency signals and composition of frequency measurement circuits
④ 设备的供电和内部电源分配
Equipment power supply and internal power distribution
⑤ 给定信号、反馈信号来源
Sources of command signals and feedback signals
3-8
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
⑥ 备注和说明
Remarks and notes:
◆ 自动控制原理框图详见设备图纸 P032;
◆ Refer to Drawing P032 for Automatic Control Functional Bock Diagram;
自动控制原理框图表明了调速器运行过程中信号采集,控制运算规律,控制信号输出的
信号传导方向,以便于理解调速系统的信号传输方向和工作原理。
The Automatic Control Functional Bock Diagram indicates the signal acquisition during the
operation of speed governors, controls the operation rule and the transmission direction of
signal output, in order to better understand the signal transmission direction and the working
principle of speed governors.
3.2.5 元器件明细表
Element List
图 3.2.5-1 元器件明细表(局部)
Figure 3.2. 5-1 Element List (partial)
◆ 目录 说明元器件的型号规格;
◆ Content to indicate the type and specification of the elements;
◆ 制造商 说明元器件的品牌和制造商;
◆ Manufacturers to indicate the brands and manufactures of the elements;
◆ 描述 说明元器件的主要技术参数;
◆ Description to indicate the main technical parameters for the elements;
3-9
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
◆ 数量 说明同一个元器件在柜内的使用数量;
◆ Quantity to indicate the numbers of a same element adopted in the
cabinet;
◆ 子装配数量和标记 说明同一个元器件柜内的使用标记和明细。
◆ Quantity and Marking of Sub-assembly to indicate the application marks and
details in a same element cabinet.
Wiring Schematics
② Cabinet
③ Element
④Signal trend
3-10
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
图 3.2.6-1 电气原理图图纸(局部)
Figure 3.2. 6-1 Electrical Schematics (partial)
原理接线图包含内容有:
The Electrical Schematics includes:
①电源转换板 物理意义:标明了此信号的物理意义;
Power supply converting board physical significance: to indicate the physical
significance of this signal;
②GR 所在柜体:其中 GR 柜为调速器电气柜,机械柜用 GM 表示,GM
表示该元器件摆放在调速器机械柜里面;
Cabinet where GR located in: here GR Cabinet is the electric cabinet for speed governors,
GM for mechanic cabinet, with GM indicating that the element is placed in the mechanic
cabinet for speed governors;
③PCI101 器件代号:元器件的柜内标识;
PCI101 element code: the marks inside the element cabinet;
④101.1B 信号走向:表明信号的来源去向,此处信号在 101 页图纸 1A 区有
引用。
101.1B signal trend: to indicate the source and whereabouts of signals, the signals
here are cited in Zone 1A on Sheet 101.
3-11
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.2.7 面板布置图
Panel Layout
Display,
instrument
Function
description
Indicator,
switch
图 3.2.7-1 面板布置图(局部)
Figure 3.2. 7-1 Panel Layout (partial)
面板布置图所包含内容有:
The Cover Sheet Panel Layout includes:
◆ 设备面板上的仪表和按钮、指示灯的整体排布;
◆ Instruments and buttons on the panel, overall layout of indicator lamps;
◆ 显示屏、仪表的位置和分布;
◆ position and distribution of displays and instruments;
◆ 指示灯、开关的位置和分布;
◆ position and distribution of indicator lamps and switches;
◆ 功能说明标牌。
◆ Function labels.
3-12
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
3.2.8 端子图
Terminal Diagram
图 3.2.8-1 面板布置图(局部)
Figure 3.2. 8-1 Panel Layout (partial)
端子图所包含内容有:
The Terminal Diagram includes:
◆远端装置代号:表明与该端子关联的其它设备;
Remote device code: to indicate other equipment in related to this terminal;
◆远端电缆编号:表明与该端子连接的电缆代号和芯号;
Remote cable code: to indicate the cable code and core no. related to this terminal;
◆端子号:表示该端子的在本端子排上的序号;
Terminal no.: to indicate the serial number of this terminal on this terminal block;
◆端子定义:表示端子连接的信号的物理定义;
Definition of terminals: to indicate the physical definitions of the signals connected to this
terminal;
3-13
调速器电气图纸读图说明
Interpretation of Electrical Drawings for Speed Governors
◆柜内装置:表示与该端子连接的柜内设备的编号。
Device inside the cabinet: to indicate the equipment no. inside the cabinet that is connected to
this terminal.
3-14
第四章
Chapter IV
调速器功能说明
Functions of Speed
Governors
4-1
调速器功能说明
Functions of Speed Governors
4.调速器功能说明 .................................................................................................................. 4
4.1 概述....................................................................................................................................... 4
General ....................................................................................................................................... 4
4-2
调速器功能说明
Functions of Speed Governors
4-3
调速器功能说明
Functions of Speed Governors
4.调速器功能说明
4.1 概述
General
调速器作为水轮机的控制器,能够判断当前机组状态,根据控制目标值下发控制指
令。其主要功能有测量与处理数据、机组工况管理、执行机构控制、故障诊断与报警等。
As the controller for the turbine, the speed governor can judge the current status of the
unit, giving a command according to the target value for control. Its main functions include:
data measurement & processing, working condition management of the unit, the control, fault
diagnosis and alarming of the actuating mechanism, etc.
调速器软件程序采用功能模块化的设计,定义出水轮机调速器的多个不同的专用功
能,设置多组针对发电机组不同工况的控制参数,采用自适应变参数调节方式,实现调
速器的频率、有功功率和流量控制等功能。
The software program for the speed governor adopts a moduled design, defines multiple
different special functions of the turbine speed governor, sets multiple groups of control
parameters for various working conditions of the generating unit, adopts self-adaptive variable
parameter regulation, realizing such functions as the frequency, active power and flow rate
control of the speed governor.
4-4
调速器功能说明
Functions of Speed Governors
图 4.1-1 软件结构示意图
Figure 4.1-1 Software Architecture Schematics
调速器功能大体分为“工况管理”、“测量及滤波”、“调节算法”、 “电液转换随动控
制”、“故障诊断”、“人机交互”、“控制权竞争”等几个部分。
The functions of speed governors can generally be divided into several parts, namely,
"working condition management", "measurement and filtration", "adjustable algorithm", "
follow-up control of electro-hydraulic conversion", "fault diagnosis", "human-machine
interaction" and "competition for right of control".
4.2 控制模式管理
Control Mode Management
4.2.1 工况管理
调速器根据外部命令、内部状态量判断当前设备的工作状况及故障信息,并且根据
设定的调节目标值进行工况的转换及故障后的响应操作。
The speed governor judges the current working conditions and fault information of the
equipment based on external commands and internal quantities of state, conducting the
working condition conversion and the pro-failure response according to the target regulation
values.
按照机组的工况,调速器的工作状态分为“停机备用态”、“开机过程态”、“空载态”、
“负载态”、“同步调相态”、“停机过程态”。在每个状态下,设备只响应特定的命令,工
4-5
调速器功能说明
Functions of Speed Governors
况转换动作明确,防止误动作。
According to the working conditions of the unit, the working status of the speed governor
can be divided into "shutdown as standby", "in-startup", "no-load", "load", "synchronized
phase modulation" and "in-shutdown". In each status, the equipment can only response to the
specific command and the conversion of working conditions is clear and definite, preventing
from misoperation.
“停机备用态”:停机备用态下停机令、并网令、远方增减令无效,调速器导叶控制
输出为微偏关,避免高水头机组在没有锁定投入情况下水压冲开导叶;此状态下不进行
测频和频率故障判断,接收到持续时间大于 2s 的开机令,转入“开机过程态”。
"Shutdown as standby": in this status, the commands of shutdown, in-connection and
remote speed-up/speed-down are invalid. The guide vane control output of speed governors is
of minimal deviation, avoiding that the guide vane is rushed away by water pressure in case of
unlocked high head unit.
“开机过程态”:此状态下手动开度给定有效,自动 PID 调节无效;进入开机过程,
导叶开启到预设的开度值;开机过程中机组频率高于设定频率值持续 2s 以上,转入“空
载态”,接收到停机令转“停机过程态”。
"In-startup": in this status, the manual opening setting is valid, auto PID regulation is
invalid; in the startup, the guide vane is opened to the preset opening value; the unit frequency
during the startup is higher than the set frequency value for over 2s and then converts to
"no-load" status, converting to the "in-shutdown" status when receiving a shutdown
command.
※ 开机过程中,超出设定的开机时间后机组频率未达到设定频率值则转入“停机过程
态”,调速器自动关闭导叶,并报调速器开机失败故障。
During the startup, when the unit frequency does not reach the set frequency value after going
over the set shutdown time, then it converts to the "in-shutdown" status. The speed governor
automatically closes the guide vane and alarms for the failure of speed governor shutdown.
※调速器在接收到开机命令时,超出设定时间后还未测到残压频率或齿盘转速,调速器
自动关闭导叶,调速器由开机过程态转停机过程态,并报调速器开机失败故障、频率故
障。
When the speed governor receives the startup command, the remaining voltage frequency or
4-6
调速器功能说明
Functions of Speed Governors
fluted disc speed cannot be measured after going over the set time, the speed governor
automatically closes the guide vane and coverts from the "in-startup" to the "in-shutdown"
status, giving an alarm for startup failure and frequency failure.
“空载态”:此状态下,自动 PID 调节有效,可选跟踪网频方式与跟踪频率给定方式,
默认跟踪频率给定方式(频率给定默认值 50Hz);空载态调速器自动调整导叶开度使频
率稳定在频率给定值。改变频率给定值时调速器操作接力器并使实际机频调节到给定的
频率值。在并网之前同期装置下发到调速器的增速/减速命令改变频率给定值,可以加快
并网过程。若空载状态时齿盘和残压测频功能全部失效,则调速器自动将导叶开度限制
在空载电气开度限制以下,防止机组过速。“空载态”时接收到“机组出口断路器合闸”信
号调速器则转入“负载态”运行,接收到“停机令”信号调速器进入“停机过程态”;
"No-load": in this status, the auto PID regulation is valid, with such three modes as
tracking grid frequency, tracking frequency setting and defaulted tracking frequency setting
selectable (with the default of frequency setting is 50Hz); the speed governor in no-load status
automatically regulates the guide vane opening to keep the frequency stable at the frequency
settings. When changing the frequency settings, the speed governor operates the servomotor
and regulates the actual frequency to the set frequency values. Before in-connection, the
synchronizing device gives a speed-up/speed-down command to the speed governor to change
the frequency settings, which can speed up the in-connection process. If the voltage
measurement functions for fluted discs and remaining voltages are invalid in case of no-load
status, the speed governor automatically limits the guide vane opening below the no-load
electrical opening limits, preventing the unit from overspeed. When receiving the "closing
unit outlet circuit breaker" signal in the "no-load" status, the speed governor then converts to
operate in the "load" status; when receiving the "shutdown command", the speed governor
then converts to operate in the "in-shutdown" status.
:此状态下,自动 PID 调节有效,频率死区,开度死区或者功
“负载态”(发电态)
率死区自动投入。
"Load" (generating): in this status, the auto PID regulation is valid, with the frequency
dead-band, the opening dead-band or the power dead-band put into operation automatically.
调速器工作于“开度模式”,负荷的调节方式为脉冲调节,调速器通过远方负荷增减
命令或电柜导叶增减旋钮使机组负荷进行增减操作。
4-7
调速器功能说明
Functions of Speed Governors
When the speed governor is working in the "opening" mode, the way to regulate the load
is of pulse regulation. The speed governor increase and decrease the unit load via the remote
load increase/decrease command or by the cube guide vane increase/decrease knob.
调速器工作于“功率模式”,则通过 LCU 模拟量给定功率或脉冲增减改变功率给定
值,调速器响应功率给定值变化操作导叶接力器使机组功率调节至给定的功率值。
When the speed governor is working in the "power" mode, it then changes the power
settings by setting the power via LCU analog or by increasing/decreasing the pulse. Changes
in the response power settings of the speed governor can operate the guide vane servomotor to
make the unit power regulated to the set power values.
调速器工作于“频率模式”,则调速器将调整导叶开度,使得机组频率稳定在机组额
定值,“频率模式”下可以通过通讯下发或者导叶开度增减信号改变开度给定,导叶开度
的最终稳定值由控制器通过 PID 运算得出。
When the speed governor is working in the “frequency” mode, the speed governor then
regulates the guide vane opening and makes the unit frequency stable at the rated values.
When in the "frequency" mode, it can give a command via communications or give a guide
vane opening increase/decrease signal, with the final stability value of the guide vane opening
worked out by the controller via PID algorithm.
“负载态”且频率稳定时,可以人为地改变调速器的“频率”“功率”“开度”模式,频率
波动超设定值(默认值 0.3Hz“沐若机组为 0.50Hz”)后,调速器自动切换到“频率模式”,
“负载态”时若“断路器合闸”信号消失则调速器进入“空载态”运行;
In case of a "load" status and stable frequency, it can change the "frequency", "power"
and "opening" modes manually. After the frequency fluctuation is beyond the settings (with
the default of 0.3Hz“for Murum Governor0.50Hz”), the speed governor can automatically
switches into the "frequency" mode. When in the "load" status, if the "closing circuit breaker"
signal disappears, the speed governor operates in the "no-load" status.
“同步调相态”(针对有调相运行要求的机组):调速器处于发电运行时,如接到“调
相运行令”,则调速器将关闭导叶,转入“同步调相态”。当“调相运行令”消失时,调速器
自动将导叶开启至空载开度,转为“负载运行态”,再按照监控指令进行增减负荷等操作。
"Synchronized phase modulation" (for units requiring phase modulation operation):
the speed governor is in generating operation, if receiving the "phase modulation operation"
4-8
调速器功能说明
Functions of Speed Governors
command, then the speed governor closes the guide vane and switches into the "synchronized
phase modulation" status. When the "phase modulation operation" command disappears, the
speed governor automatically opens the guide vane to the no-load opening and switches into
the "load" operation status, conducting load increase/decrease as per the monitoring
command.
“停机过程态”:调速器进入停机过程,执行完全关闭导叶接力器,此时开机令、并
网令、增减令无效;调速器在停机过程中判断导叶开度小于设定值(默认值 2%)及机
组频率小于设定值(默认值 10Hz)后停止测频故障判断功能;停机过程完成后调速器
转入“停机备用态”等候下一次机组正常开机。
"In-shutdown": the speed governor is in the shutdown process, closing the guide
vane servomotor completely. The commands of shutdown, in-connection and remote
speed-up/speed-down are invalid at the moment. When the speed governor judges during the
shutdown process that the guide vane opening is less than the settings (with the default of 2%)
and the unit frequency is less than the settings (with the default of 10Hz), it stops verifying the
frequency measuring failure. After the shutdown process is over, the speed governor switches
to the "shutdown as standby" status, waiting for the next normal startup of the unit.
4.2.2 操作方式切换
自动操作功能:调速器正常运行时处于自动操作的状态,此时调速器根据采集的模
拟量信息、开关量状态判断当前所处的工况,并且根据增加/减少、开机/停机等操作命
令做出响应动作,不需要人为干预就能够自动完成机组操作的所有功能。
Automatic operation: when operating normally, the speed governor is in the automatic
operation. The speed governor at the moment judges the current working conditions based on
the collected analog and the switching status, making a response to such commands as
increase/decrease, startup/shutdown, etc., automatically realizing all the functions of the unit
operations without artificial intervention.
手动操作功能: 调速器配置了手动操作功能,手动操作时为开环控制,与频率、
开度、功率差值无关系,调速器根据手柄或者手轮的动作角度控制接力器开向与关向。
实际运行过程中,机组有功功率/频率过高、过低时,需要人为干预才能实现对设备的控
4-9
调速器功能说明
Functions of Speed Governors
制。手动开关一旦投入,调速器上的电机或比例阀等执行机构被直接切除,手动作为后
备保护性操作,其优先级最高。
Manual operation: the speed governor is featured with the manual operation. When in
manual operation, it adopts open-loop control, irrelevant to frequency, opening and power
difference. The speed governor controls the opening and closing directions of servomotors
according to the motion angles of the knob or the handwheel. In the actual operation process,
when the active power/frequency of the unit is too high and too low, it requires artificial
intervention to realize the control over equipment. Once the manual switch is used, such
actuating mechanism as the motor or the proportional valve of speed governors are directly
eliminated, with the manual operation adopted as the backup protective operation of the
highest priority level.
手动操作方法——通过手柄手轮或手动操作阀来控制调速器开关,手动操作时建议
采用点动方式,即操作释放操作释放,手动操作时应观察仪表,确保机组的运行
状态不发生突变。
Manual operation method--to control the switch for speed governors by the knob, the
handwheel or the manual operating valve. It is suggested to adopt an inching manner for
manual operation, that is, operationreleaseoperationrelease. Please observe the
instruments during the manual operation, ensuring that no abrupt changes occur when the unit
is in operation.
※注意:调速器工作在任何状态下出现交流、直流工作电源全部消失的情况,调速
器将报大故障和工作电源消失。
※Note: when the AC and DC working power supplies all disappear when the speed
governor is working in any status, it will alarm for the failure and the disappearance of
the working supply.
调速器在任何工作状态下,由监控系统启动紧急停机流程或者事故停机流程的同
时,必须向调速器下发停机命令。
When the speed governor works in any status, a shutdown command must be given
to the speed governor while the monitoring system starts the emergency shutdown
process or the accident shutdown process.
4-10
调速器功能说明
Functions of Speed Governors
4.3 测量及滤波
4.3.1 信号测量
Signal measurement
4.3.2 信号测量
Signal measurement
工业环境中的多数信号都存在干扰,也可能出现信号突然中断等情况。为保证机组
采用的信号更加接近真实值,使得设备更加安全稳定地运行,就必须对这些信号进行处
理,及时判断信号故障,并作出合理的应急处理。
Interference exists in multiple signals in the industrial environment and such cases as
abrupt signal interruption may occur. In order to ensure that the signal acquired by the unit
approaches to the actual value all the more and make the equipment operate in a safer and
stabler manner, it must process these signals, make timely judgment of signal failures and
rationally respond to the emergencies.
针对本设备运行环境的特点,设备中采用“限幅滤波”的方式对模拟量信号进行处
理,即不断地检测本周期采样与上周期采样的差值,越过设置的容忍范围则本次值无效,
反之则有效,当采样数值越过所使用的传感器的有效量程之后会判采样故障。
Based on the features of the operation environment of the equipment, it adopts a
"filtration with limited amplitudes" method to process the analog signals, that is, to
ceaselessly test the differences between samples of this period and last period. The value of
4-11
调速器功能说明
Functions of Speed Governors
this time will be invalid when exceeding the allowed scope of settings and be valid conversely.
When the sampling values goes over the valid measuring range for the used sensors, it can
verify a sampling failure.
4.3.3 测频部分工作原理
automatically switches to the fluted disc frequency measurement, which can sufficiently
ensure the unit operation; however, the actual precision of the fluted disc frequency
measurement is limited to the processing precision and the probe installation of fluted discs.
测频的算法:残压频率信号或者齿盘脉冲信号经过整形处理后成为标准的方波,方
波信号送入控制器测频专用模块进行周期测量 T,最后根据公式 f=1/T,计算出频率值。
Frequency measurement algorithm: the remaining frequency signal or the fluted disc
impulse signal become the standard square wave after reshaping, the square wave signal is
sent to the frequency measurement module special for the controller for periodic measurement
T, finally working out the frequency value based on the formula f=1/T.
机频测量的冗余:MGC3000 系列采用了齿盘信号和残压 PT 信号 2 种测频方式对机
组的频率进行测量,保证了机组频率可靠性。机组处于开机过程的开始阶段时,残压测
频的信号幅值较低,不能满足测频的需要,因此采用齿盘频率作为机组频率,当调速器
转入空载之后,残压测频的信号幅值已经大于 300mV,采用残压频率作为机组频率;机
组空载或者负载运行的过程中,发生残压机频故障时,取齿盘频率作为机组频率,如主
用机残压机频故障和齿盘测频故障同时发生,则判为调速器频率大故障且将进行主备用
切换,主用机频率大故障时切换至备用机状态,原备用机切换至主用状态,测频运算及
输出继续正常执行。假如双微机控制器都为频率大故障,机组频率强制输出 50Hz。
Redundancy of frequency measurement: the MGC3000 series adopt such two
frequency measurement methods as the fluted disc signal and the remaining voltage PT signal
to measure the unit frequency and ensure the reliability of frequency measurement. When the
unit is at the beginning of the startup process, the amplitude value for remaining voltage is low,
which cannot meet the requirement for frequency measurement. Therefore, it adopts the fluted
disc frequency measurement for the unit frequency, when the speed governor converts into the
no-load operation, the signal amplitude value of the remaining voltage frequency
measurement is more than 300mV, adopting the remaining voltage frequency for the unit
frequency; when a remaining voltage frequency failure occurs in case the unit is in no-load or
load operation, adopting the fluted disc frequency for the unit frequency; when the host
remaining voltage frequency failure and the fluted disc frequency measurement failure
simultaneity occur, then the speed governor frequency is of major failure, with the host and
standby controllers switched. When the host frequency is of major failure and switched to a
4-13
调速器功能说明
Functions of Speed Governors
standby status, the original standby controller switches to the host status, with the frequency
measurement calculation and output conducted as normal. In case of major failure in dual
microcomputer controllers, the pushed output of the unit frequency is 50Hz.
图 4.3.3-1 控制器测频原理图
Figure 4.3.3 -1 Controller Frequency Measurement Schematics
4.4 调节算法
Regulation Algorithm
4-14
调速器功能说明
Functions of Speed Governors
比例(P)
机组 F
fg
– 放大器
1 KP
频率 + 电液转换器
引导阀、主配压阀
微分(D) 数模 主接力器
+ Y 转换
PID u + A2
KDS + 1
频率 1 y
fc 1 1+T1vS + – TyS
给定
+ 积分(I)
KI 3-2(3-1)
S
+ 位移转换
1
bp
开度 + –
yc 1
给定
图 4.4.1-1 电液型调速器导叶控制方块图
Figure 4. 4.1-1 Electro-hydraulic Speed Governor Guide Vane Control Block
图示为调速器工作在频率调节模式时的导叶控制方块图,机组频率与频率给定值
(或电网频率)做差值,送 PID 调节软件模块,PID 调节原理用传递函数表示如下:
It indicates the guide vane control block diagram when the speed governor works in the
frequency regulation mode, based on the difference between the unit frequency and the
frequency settings (or the grid frequency) and provided with the PID regulation software
module. The PID regulation principle is expressed by the following transfer functions:
KI KDS
W (S ) K
(1 T1V S )
p
S
式中:
Whereas:
K P —— 比例增益,
K P —— proportional gain;
K I —— 积分增益,
K I —— integral gain;
K D —— 微分增益,
K D —— differential gain;
4-15
调速器功能说明
Functions of Speed Governors
工程中为提高装置的抗干扰能力,采用实际微分环节,微分环节时间常数 T1V ( S ) 。
将上述传递函数离散化,设 PID 输出表达式:
In the project, it adopts the actual differentiation element and the differentiation element
所以就有:
Therefore,
y PID (k ) y PID (k 1) k P [ x(k ) x(k 1)]
T1v 1
k1 x(k ) y D (k 1) k D [ x(k ) x(k 1)]
T1v T
上式中,为采样周期。x 为相对频率差,即频率给定或电网频率与机组频率之差和
额定频率的比值。上述 PID 调节器框图中,PID 输出与开度给定综合后,经永态转差系
数环节,送至积分环节输入端,与频率偏差 x 综合后进行积分。
In the above formula, refers to the sampling period. x stands for the relative frequency
difference, that is, the ratio of the difference (between frequency setting or grid frequency and
unit frequency) and the rated frequency. In above PID governor block diagram, the PID output
4-16
调速器功能说明
Functions of Speed Governors
and the opening setting is incorporated and sent to the input of the integrating element via the
permanent speed droop element, getting integrated by incorporating with the frequency
deviation x.
水轮发电机组并入大电网后,调速器从频率控制模式转换至开度控制模式或功率控
制模式后,微分环节增益设置为 0。此时调速器的调节为 PI 调节。由于频差在频率死区
以内,故相对频率差为 0,故 y PID (k ) =0,则此时要使得调速器响应调节命令并操作接力
器开关,必须调节开度给定 y C 。
After the turbine generating unit connects to the main grid, the speed governor switches
from the frequency control mode to the opening control mode or the power control mode,
with the gain for differentiation element set as 0. The speed governor now adopts PI
regulation. As the frequency difference is within the frequency dead-band, therefore, the
relative frequency difference is 0, that is, y PID (k ) =0, it must regulate the opening setting y C ,
in order to make the speed governor respond to the regulation command and operate the
servomotor switch.
一次调频功能投入后,当机组频率与电网频率或给定频率之差越过设定的频率死
区,则调速器按照 PI 调节规律调整接力器开度,在一次调频动作过程中,yc 如果保持
不变,则当机组频率回到正常值之后,导叶应回到一次调频动作之前的位置。一次调频
动作过程中,调速器接到有功功率增加或减少指令,则调速器的动作可能出现开向或者
关向的累加,调速器最终稳定在 yc 处。
When using the primary frequency regulation, the difference between the unit frequency
and the grid frequency or the set frequency exceeds the set frequency dead-band, then the
speed governor regulates the servomotor opening as per the PI regulation rule. During the
primary frequency regulation operation, if yc keeps unchanged, then after the unit frequency
returns to the normal value, the guide vane shall go back to the position before the primary
frequency regulation. During the primary frequency regulation, the speed governor receives
the active power increase/decrease command, and then the speed governor operation may be
accumulated for its opening or closing direction, with the speed governor finally stable at yc.
※注意:监控系统在收到调速器一次调频动作的信号时,建议暂时封闭调速器增/
减命令的开出,以免影响一次调频效果。
4-17
调速器功能说明
Functions of Speed Governors
※Note: when the monitoring system receives the primary frequency regulation
from the speed governor, it is suggested to temporarily forbid the issuing of speed
governor increase/decrease command, in order to avoid an impact exerted on the
primary frequency regulation effect.
在开机过程、停机过程、发电调相运行和停机备用状态时,为避免频率测量的不稳
定性对调速器控制产生不利影响,自动 PID 调节无效,手动 PID 调节投入,即认为地设
regulation is used, that is, the relative frequency difference x is set as 0, then y C = y PID , the
图 4.4.1_2 开环增量环节方块图
opening setting and the power setting, it sets the open-loop gain element to make y PID
respond to and track as per the technical specifications. When the operator operates via the
4-18
调速器功能说明
Functions of Speed Governors
button, y PID then gets increased or decreased quickly. When stop the operation, the y PID
y C immediately. When the value for the host computer is set, the
stop at the set opening
open-loop gain element y PID gets increased /decreased as per the speed stipulated by the
technical specifications.
为便于运行人员操作,在智能触摸显示控制单元中采用人们较为熟悉的参数。
In order to facilitate the operation by the operator, the intelligent touch-screen control
unit adopts the parameters that are popular.
bt -暂态转差系数;
Td -缓冲装置时间常数,单位:秒;
Tn -加速时间常数,单位:秒;
4-19
调速器功能说明
Functions of Speed Governors
4.5 随动系统
Follow-up System
3-1 3-2
位移转换
图 4.5-1 电液随动型调速器结构框图
Figure 4.5-1 Electro-hydraulic Follow-up Speed Governor Structure Diagram
如上图所示,本产品在控制结构上的特点有:
As indicated in the above diagram, the product is featured as follows concerning the
control structure:
这种调速器系统结构有如下特点:
The speed governor system has the following structural features:
微机调节器输出模拟电流 4~20 mA(或 0~10V),在图中以 u 表示,u 是微机调节
器的“电气”接力器的符号,转换驱动环节是数/模转换(D/A)。
The microcomputer regulator output simulate 4~20 mA (or 0~10V) current, which is
expressed as u in the diagram, u is the symbol for the "electrical" servomotor of the
microcomputer regulator, with the conversion driving element of digital/analog conversion
(D/A).
电液转换装置可完成电气信号至机械液压信号的转换,称为电液转换器,其控制参
数为:24V,4~20 mA/0~±10V;另外,电液转换装置还可以完成机械液压信号至电气
信号的转换,例如常采用的有电位器式或感应式接力器位移转换器,与微机调节器输出
相匹配,对应于接力器全行程的反馈电压值为 0~+10V(或 0~20mA),伺服电机上安装
了旋转编码器,电机旋转的角度由电机上的旋转编码器传递给电机。
The electro-hydraulic conversion device can complete the conversion from the electrical
signal to the mechanical hydraulic signal, which is referred to as electro-hydraulic converter,
4-20
调速器功能说明
Functions of Speed Governors
with the control parameters are 24V, 4~20 mA/0~±10V. In addition, the electro-hydraulic
conversion device can also complete the conversion from the mechanical hydraulic signal to
the electrical signal, for instance, the commonly adopted potentiometer or induction type
servomotor displacement transducer, matching with the microcomputer regulator output. The
feedback voltage corresponding to the full servomotor stroke is 0~+10V (or 0~20mA), the
servomotor is provided with the rotary encoder, with the rotating angle transmitted to the
motor via the rotary encoder.
调节器中起闭环调节作用的电气综合比较点为 A2,因此电液随动系统由电液转换装
置和机械液压系统一起构成。
The electrical comprehensive comparison point A2 plays a role on closed cycle control in
the speed governor, therefore, the electro-hydraulic follow-up system consists of the
electro-hydraulic conversion device and the mechanical hydraulic system.
图中所示的机械综合比较点 A3 和反馈通道 3-3 用于机械开度限制和机械液压手动工
况,图中用虚线表示。在调速器自动运行工况,且不受机械开度限制机构限制时,综合
比较点 A3 和反馈通道 3-3 不起作用。
The mechanical comprehensive comparison point A3 and the feedback channel 3-3
indicated in the diagram are used for mechanical opening limit and the manual mechanical
hydraulic working conditions, as marked with dashed lines in the diagram. When the speed
governor works automatically and is not limited to the mechanical opening limits, the
comprehensive comparison point A3 and the feedback channel 3-3 take no effect.
4.6 控制权竞争
4.6.1 双微机控制器在控制执行机构划分
调速器切换监视功能控制两套微机控制器主备切换,实现调速器来电自启动、手动
切换、故障自动切换、故障报警等功能。适用于开机、空载、负载、停机等各种调速器
状态。其利用双机握手及硬件光隔离的原理使该功能能够兼容 MGC 所有双机系列型号
的调速器产品。
The switching & monitoring function of speed governors controls the host/standby
switching of the two microcomputer controllers, realizing the auto startup on energization,
manual switch, auto switch on failures and failure alarms, etc. for speed governors. It applies
to various statuses such as startup, no-load, load, shutdown, etc. for speed governors. Due to
dual controller interface and hardware optical isolation principle, it is compatible with all
speed governors of MGC dual controller series.
来电自启动:当调速器遭遇到停电再来电时,调速器来电自启动,调速器 A\B 机上
电主用判断为先启动完毕的控制器为主用机运行,调速器主用机能够自动接收及发
送对内对外信息,并且进入断电前设定的运行模式及参数设置(不包括手自动状态),
不需要人工干预设置,既省事又保证可靠性。
Auto startup on energization: when the speed governor is energized after a power
failure, the speed governor starts automatically when it is energized. The energization of
Controller A/B of speed governors is verified that the controller first to complete the
startup is the host controller. The host controller of speed governors can automatically
receive and give incoming and outgoing information, entering into the operation mode
and parameter settings as set before the power failure (excluding the manual-auto status),
requiring no artificial intervention, which is convenient and reliable.
4-22
调速器功能说明
Functions of Speed Governors
※ 注意:调速器自启动后为手动操作状态,需运行人员检查调速器无事故报警方可切到自动
运行
※ Note: the speed governor is in manual operation after an auto startup. The operator verifies
that there is no alarm for the speed governor before switching to the automatic operation.
手动主备切换:调速器具备手动切换主备用机功能,其在电柜按钮面板上操作。
Manual host/standby switching: the speed governor can switch manually the
host/standby controllers, which can be done via the buttons on the cube panel.
示例:当 A 机为主用机时,操作面板 B 机主用按钮,即可平稳转换到 B 机主用工
作,并且人机界面相应自动转换主用机数据。
Example: when Controller A is the host controller, to operate the host button on the panel
for Controller B, it can stably switch Controller B as the host controller, with the HMI
automatically switching for the host data accordingly.
(温馨提示:手动切换至执行控制逻辑含有延时操作功能,必须按住按钮大于设定值(默认设置
300ms)时才能切换操作,目的在于有效的规避人为处于频繁的切换开关的情况发生,并规避无意
的触摸)
(Kindly reminder: manual switching to execute control logic has an operation delay function; it must
press the button for more than the set time values (with the default of 300ms) before the switching
operation, it is aimed to effectively avoid the frequent switching artificially and unintentional touch).
单套控制故障自动切换:当调速器主用机出现大故障时进行切换,一般小故障不进
行切换。切换大故障的定义为接力器传感器总故障,主配传感器故障,比例阀系统
故障,电机系统故障,频率总故障,控制器大故障(包含控制器失电)。
Auto switching of single controller failure: to switch when major failures occur to the
host controller of speed governors, no switching in case of minor failures. Major failures
for switching are defined as total failure in servomotor sensors, failure in main
distributing sensors, failure in proportional valves, failure in motor system, total failure in
frequency, major failures in controllers (including controller disenergization).
只要以上任一故障出现,主备切换设定标志输出为 1,调速器进入主备切换状态。
Once any one of the above failures occurs, the set mark output of host/standby switch is 1
and the speed governor enters the host/standby switching status.
示例:B 机为主用机,A 机为备用机;当 B 机出现接力器传感器总故障时,调速器
4-23
调速器功能说明
Functions of Speed Governors
4-24
调速器功能说明
Functions of Speed Governors
Example: Controller A is the current host controller; Controller B is the current standby
controller. When major failures occur to Controller A, it automatically switches
Controller B as the host controller, with the major failures in Controller A unrecovered;
when major failures also occur to Controller B, Controller B still works as the host
controller, with all the incoming and outgoing receipt and issuance done by Controller
B;
状态 2:双套控制器同时故障
Status 2: the dual controllers failed at the same time
示例:A 机为当前主用机,B 机为当前备用机。当 A\B 机同一时刻出现大故障时,
A 机仍然为主用机,所有对内对外接收与发送为 A 机操作;
Example: Controller A is the current host controller; Controller B is the current standby
controller. When major failures occur to Controllers A/B at the same time, Controller A
is still the host controller, with all the incoming and outgoing receipt and issuance by
Controller A;
※ 注意:调速器出现双套控制故障时,调速器由自动状态转到手动状态。手动主备切换无效,
必须大故障消失才能进行手动主备切换操作。
※ Note: when control failures occur to the dual controllers, the speed governor switches from
auto to manual status. The manual host/standby switch is invalid, only when the major
failure disappears can the manual host/standby switching operation be conducted.
4.7 诊断及容错功能
MGC3000 系列调速器具有非常强的诊断及容错功能,不仅包括内部自身的诊断,
还包括外部信号的诊断。内部诊断包括控制器各功能模块、应用程序的诊断;外部信号
包括反馈信号、测频信号、水头信号、功率信号、通信等信号的诊断及容错。故障及事
4-25
调速器功能说明
Functions of Speed Governors
件信号在人机界面或操作终端上显示,并送出综合处理的信号。
The MGC3000 series speed governors are strong in diagnosis and fault-tolerance,
not only including the internal diagnosis of itself, but also for external signals. The
internal diagnosis include each functional modules of the controller and the diagnosis of
applications; the external signals include diagnosis and fault-tolerance for feedback
signal, frequency measurement signal, water head signal, power signal, communication
signal, etc. The failure and event signals are displayed on HMI or operation terminal,
sending a signal for comprehensive processing.
电网频率信号的容错
Fault-tolerance of grid frequency signal
电网频率故障时,频率跟踪模式自动切换到跟踪频率给定模式,默认值 50Hz。
When a failure occurs to grid frequency, the frequency tracking mode automatically
switches to the tracking frequency setting mode, with the default of 50Hz.
机组频率信号的容错
Fault-tolerance of unit frequency signal
残压频率故障时转到齿盘频率信号主用,齿盘频率也同时发生故障时,切换到
另一套正常的控制器运行。双套控制器的残压及齿盘信号都故障时,在空载运行状
态下,导叶开度关到安全的空载位置,可以接收停机令;并网负载运行状态下,机
组频率直接采取 50Hz,机组保持原状态不变化,可以接收增减命令进行操作。
In case of remaining voltage frequency failure, it switches to fluted disc frequency signal
for the host controller, when the fluted disc frequency also failures, it switches to the
other controller that is in normal operation. When the remaining voltage and fluted disc
signals both fail for the dual controllers, when in no-load operation, the guide vane
opening is closed to the safe no-load position, which can receive the shutdown command;
in case of in-connection load operation, the unit frequency adopts 50Hz directly, with the
unit kept its original status unchanged, which can receive the increase/decrease command.
4-26
调速器功能说明
Functions of Speed Governors
一套控制器中控制反馈信号、驱动系统、控制器硬件系统任意一项出现故障时,切
换到正常的另一套微机运行,双套控制器中都出现任意一项故障时,调速器切手动
运行,维持导叶开度不变。
When any one of the control & feedback signal, driver and controller hardware system
fails in one controller, it switches to the other controller that is in normal operation; when
any one fails in the dual controllers, the speed governor switches to the manual operation,
keeping the guide vane opening unchanged.
水头信号故障时,由跟踪水头传感器信号方式,改为跟踪人工设置水头方式,并当
前水头值保持不变。
In case of water head signal failure, it switches from the tracking water head sensor
signal mode to the tracking manual set water head mode, with the current water head
value kept unchanged.
功率信号故障时,由功率模式调节变成开度模式调节,可以接受增减及停机命令。
In case of power signal failure, it switches from the power mode regulation to the
opening mode regulation, which can receive the increase/decrease and shutdown
commands.
人机界面或其它操作终端故障时,仍能完成调速器正常的各种功能,如开机、停机、
并网、负荷增减、一次调频、甩负荷、故障检测及保护等功能。
In case of failures in HMI or other operation terminals, it still can complete the various
speed governor functions normally, such as startup, shutdown, in-connection, load
increase/decrease, primary frequency regulation, load shedding, failure detection and
protection, etc.
调速系统交直流的诊断及容错
AC/DC diagnosis and fault-tolerance of governing system
交直流系统,任意一项故障时,都不会影响机组的正常运行;交直流都故障时,
机械液压系统自动复中位,保持机组的正常发电态;少数没有自复中功能的调速器
会直接关闭导叶,并报事故态。
When any one item of the AC/DC system fails, it will not exert an impact on the
normal operation of the unit; when both AC and DC fails, the mechanical hydraulic
system recovers the mid-position automatically, keeping the unit in normal generating
4-27
调速器功能说明
Functions of Speed Governors
status; a few speed governors that are not self-recovers will close the guide vane directly
and alarm accident status.
机械液压执行机构的诊断及容错
Diagnosis and fault-tolerance of mechanical hydraulic actuating mechanism
比例阀系统故障时,自动切换到电机系统运行,电机系统故障时,自动切换到
比例阀系统运行;比例阀与电机系统都故障时,机械液压系统自动复中位,维持导
叶开度不变。
In case of a failure in the proportional valve, it switches to the motor system
operation automatically; in case of a failure in the motor system, it switches automatically
to the proportional valve system operation; in case of failures both in the proportional
valve and the motor systems, the mechanical hydraulic system automatically recovers to
the mid-position, keeping the guide vane opening unchanged.
4-28
第五章
Chapter V
调速器试验规程
5-1
调速器试验规程
Test Code for Speed Governors
本章内容见我公司提供的
Please refer to the following documents as submitted by the Company for this Chapter:
《水轮机调速器出厂调试规程及报告》
Test Code and Report on Delivery Debugging of Turbine Speed Governors
《水轮机调速器现场调试规程及报告》
Test Code and Report on Field Debugging of Turbine Speed Governors
报告内容由我公司人员根据试验情况填写
The report is made by the Company based on the tests.
5-2
第六章
Chapter VI
调速器人机界面
6-1
调速器人机界面
HMI for Speed Governors
6.调速器人机界面 ..................................................................................................... 3
6-2
调速器人机界面
HMI for Speed Governors
6.调速器人机界面
6.1 概述
General
MGC4000 系列调速器均配置了人机界面,提供了简洁友好的人机交互界面,其主
要作用显示设备的运行状态,将运行人员需要完成的操作指令转换之后下发给设备。
The MGC4000 series speed governors are provided with simple and friendly HMI, which
mainly displays the operation status of the equipment and send the operational command
required to be fulfilled by the operator to the equipment upon conversion.
6.2 人机界面与控制器通讯
人机界面与控制器之间通讯采用以太网链路或者串行口通讯,其物理连接主要有以
下的两种形式。
The communication between HMI and the controller adopts the Ethernet link or serial
port, with two main physical connection forms as follows.
◆ 人机界面和控制器通过网线(或以太网交换机)连接。
◆ The HMI and the controller are connected via the network cable (or the Ethernet
exchanger).
◆ 人机界面和控制器直接通过串口通讯电缆连接。
◆ HMI and the controller are connected directly via the cables for serial port
communication.
6.3 人机界面画面显示
HMI Display
6.3.1 画面布局
Layout
按照使用目的,将人机界面划分为以下的几个部分:
6-3
调速器人机界面
HMI for Speed Governors
HMI is divided into the following parts according to the application purposes:
◆ 数据展示页面
◆ Data presentation screen
◆ 参数设置页面
◆ Parameter setup screen
◆ 试验设置界面
◆ Test setup screen
◆ 事件信息页面
◆ Event Information screen
6.3.2 数据展示页面
数据展示页面包含人机界面的主页面和数据显示页面。
The data presentation screen includes the home page and the data presentation screen
for HMI.
(一)主页上的信息为只读,不可操作,主页显示内容有:
(I) the information on the home page is read-only and non-operational, with the contents
displayed on the home page including:
◆ 当前调速系统的重要数据和状态,如导叶开度、桨叶开度(双调节型机组)、频率、
有功功率、开度限制等模拟量信息以及自动/手动/电手动操作模式、频率/开度/功率运行
模式和机组工况等开关量信息。
◆ The current key data and status of the governing system, such as analog information on
guide vane opening, paddle opening (a dual-modulation unit), frequency, active power,
opening limit and switching information on auto/manual/motorized operation modes,
frequency/opening/power operation modes and working conditions for the unit.
6-4
调速器人机界面
HMI for Speed Governors
图 6.3.2-1 主页面
Figure 6.3.2 -1 Home Page
(二)数据显示页面显示内容有:
(II) The contents displayed on the data presentation screen include:
◆ “导叶开度”——显示双机各自的导叶接力器的位置。
◆ "Guide vane opening"--to display the guide vane servomotor position of each dual
controllers.
◆ “机组频率”——显示双机各自的机组频率。
◆ "Unit frequency"--to display the unit frequency of each dual controller.
◆ “频率给定”——显示双机各自频率调节目标值,默认 50Hz。
◆ "Unit setting"--to display the target value for frequency regulation of each dual
controllers, with a default of 50Hz.
◆ “开度给定”——显示双机各自的导叶接力器调节的目标值。
◆ "Opening setting"--to display the target value for regulating the guide vane servomotor.
6-5
调速器人机界面
HMI for Speed Governors
◆ “功率给定”——显示双机各自有功功率的调节目标。
◆ "Power setting"--to display the target regulation value for active power of each dual
controller.
◆ “PID 给定”——显示双机各自 PID 调节输出值。
◆ "PID setting"--to display the output value for PID regulation of each dual controllers.
◆ “运行水头”——显示双机各自采用的水头值。
◆ "Operational water head"--to display the water head value adopted for each dual
controllers.
◆ “开度限制”——显示双机各自的电气开限数值。
◆ "Opening limit"--to display the electrical opening limit value for each dual controllers.
◆ “有功功率”——显示双机各自采集的实发有功数值。
◆ "Active power"--to display the active power value acquired for each dual controllers.
◆ “电网频率”——显示双机各自的电网频率信息。
◆ "Grid frequency"--to display the grid frequency information of each dual controller.
◆ “PID 参数”——显示双机各自的 PID 运行参数。
◆ "PID parameters"--to display the PID operation parameters for each dual controller.
◆ “桨叶开度”——显示双机各自桨叶开度值信息(双调型机组配置)
◆ "Paddle opening"--to display the paddle opening value for each dual controller
(dual-regulation unit).
6-6
调速器人机界面
HMI for Speed Governors
图 6.3.2-2 数据显示页面
Figure 6.3.2 - 2 Data Presentation Screen
6.3.3 参数设置页面
在功能切换区域中点击“参数设置”按钮进入。
To click "Parameter Setup" button to enter this screen in the function switching zone.
一、PID 参数设置,各个数据栏中会显示当前的各个工况下的 PID 参数,对参数进
行修改之后,点击“确定”,设置的参数会被写入控制器中。
I. for PID parameter setting, each data column displays the current PID parameters
for each working conditions; to click "Enter" after modifying the parameters, with the
set parameters written in the controller.
◆ 空载参数 修改这一组参数将改变调速器在“机组出口断路器”合
闸之前的调节效果。
6-7
调速器人机界面
HMI for Speed Governors
6-8
调速器人机界面
HMI for Speed Governors
未进行试验验证的参数不得作为实际运行用的参数。每一项试验结束,恢复所有参数。调速器 PID
参数页面可以修改备用机 PID 参数,每套控制器的 PID 都为单独一页面,页面左上角有 A\B 机标志
提示,切勿修改非当前机的 PID 值。
※Note: after setting the PID parameters, the parameters can be used as the application data for
the speed governor only upon tests and validation, to control the unit operation. Parameters cannot
be used as parameters for real operation without tests and validation. All the parameters shall be
recovered after each test. The PID parameter screen for speed governors can modify the PID
parameters for the standby controller, with the PID for each controller on a separate screen. There is
a Controller A/B mark in the top left-hand corner of the screen, please do not modify the PID values
of the non-current controllers.
6-9
调速器人机界面
HMI for Speed Governors
二、空载开度和负载开度限制设置
II. Limit setup for no-load opening and load opening
在本页面进行开机空载开度,负载开度限制和协联运算设置。具体设置办法如下:
To set the no-load opening limit, load opening limit and associated arithmetics for startup
on this screen. The setup method is as follows:
图 6.3.3-2 协联设置
Figure 6.3. 3 - 2 Associated Setup
本页面内有空载开度,负载开度限制设置,共有 15 个水头点,根据运行经验将对
应水头下的空载开度、负载开限和抽水运行根据水头优化开度的设置到对应的水头下,
运行过程中,控制器根据不同的水头值调用不同的设置值。
6-10
调速器人机界面
HMI for Speed Governors
The screen covers limit setup for no-load opening and load opening, with 15 water head
points in total. It can based on the operation experience, set the no-load opening limit, load
opening limit and pumping operation for the corresponding water heads according to the
optimized opening for water heads. The controller call different settings as per the different
water head values.
※注意:新建电站在设置这些参数时,必须参考主机厂提供的资料。长期运行之后,可根据运行的
实际情况,修改空载开度和负载开度限制。
※Note: When setting a newly-built power station for these parameters, it must refer to the data
provided by the host controller manufacturers. After a long-term operation, it can modify the limits
for no-load opening and load opening according to the actual operation situation.
◆ 水头 根据运行经验将机组可能遇到的运行水头划分为 15 段,将每一段的分
段点设置到水头一栏,设置规律从左到右水头设置值逐渐增减。
◆ Water head According to the operation experience, to divide the operational water heads
that the unit may encounter into 15 sections, with each sub-section points set under the
water head column, gradually increase and decrease the water head settings from left to
right by making the rules.
◆ 空载开度 根据运行经验将水头数值设置到以上表格内之后,再把对应水头下的
空载开度数值设置到空载开度一栏,设置值可以比实际的空载开度值大 1%~2%开
度,设置规律是水头越高,空载开度越低。
◆ No-load opening According to the operation experience, to set the water head values
in the above tables and then set the no-load opening value of the corresponding water
head in the no-load opening column. The settings can be 1%~2% more than the actual
no-load opening value, with a rule that the higher the water head, the lower the no-load
opening.
◆ 负载开限 根据运行经验将以上各个水头下对应的导叶满发时的开度值设置到
负载开限一栏,设置值可以比实际的满发开度值大 1%~2%。
◆ Load opening limit: according to the operation experience, the opening value of the
guide vane in full load corresponding to each water head above can be set to the load
opening limit column, with the setting 1%~2% more than the actual full-load opening
value.
◆ 协联插值表 根据主机厂提供协联值将各个水头下对应的桨叶协联值设置到协联
6-11
调速器人机界面
HMI for Speed Governors
插值表一栏。
◆ Associated interpolation table: according to the associated interpolation provided by
the host controller manufacturer, set the paddle associated interpolation corresponding to
each water head to the associated interpolation table column.
注意:长期运行之后,需要根据运行的实际情况,修改空载开度和负载开度限制,在测得多个水头
下抽水运行的效率值之后也可以修改根据水头优化导叶开度的设置值。
Note: after a long-term operation, it is required to modify the limits for no-load opening and load
opening according to the actual operation situation. It can also modify the settings after measuring
the efficiency values for pumping operation of multiple water heads, based on the settings of the
optimized guide vane opening for water heads.
调速器开机参数页面可以修改备用机开机参数,每套控制器的开机参数都为单独一页面,页面左上
角有 A\B 机标志提示,切勿修改非当前机的开机参数值。
The startup parameter screen for speed governor can modify the startup parameters for the standby
controller, with the parameters for each controller on a separate screen. There is a Controller A/B
mark in the top left-hand corner of the screen, please do not modify the startup parameters of the
non-current controllers.
三、控制参数设置
Control parameter setup
进行模拟试验之前,有必要对电机控制,比例阀控制以及外部命令操作给定值的变
化率进行设置,在“控制参数”调整页面可以完成对调速器控制性能的调节。
Before an analog test, it is necessary to set the motor control, proportional valve control
and change rate for the set values of external command. It can complete the regulation of the
control performance of speed governors on the "Control Parameters" screen.
6-12
调速器人机界面
HMI for Speed Governors
图 6.3.3-3 控制参数设置
Figure 6.3.3 - 3 Control Parameter Setup
在本页面内可以对伺服电机,比例阀的控制性能,对调速器调节的速率以及功率模
式控制的特性做出调节,以使得调速器调节快速、稳定。
On this screen, it can regulate the control performance of servomotor and proportional
valve, the speed of speed governors and the control characteristics of power mode, so that the
speed governor can regulate rapidly and stably.
四、模拟量输入校准
IV. Calibration of Analog Input
在本页面可以实现传感器的校准和越限报警设置。
It can realize the setup of sensor calibration and limit alarming on this screen.
6-13
调速器人机界面
HMI for Speed Governors
图 6.3.3-4 模拟量校正
Figure 6.3.3 - 4 Analog Calibrations
◆ 模拟量校正页面,包括传感器的零点采样值、满度采样值、采用低限值、采用高限
值、输出低限值、输出高限值。
◆ The analog calibration screen includes zero sampling values, full-scale sampling value,
lower sampling limit, higher sampling limit, lower output limit, higher output limit.
◆ 如导叶反馈通道,当导叶全关时,将导叶反馈通道采样值的数值键入“零点设置”,
当导叶全开时将采样数值键入“满点设置”,“采样低限”的设置应比“零点设置”的数值略
小,“采样高限”的设置应该比“满点设置”的数值略大,“输出低限”设置为 0,“输出高限”
设置为 9999,表示导叶开度范围为 0~99.99%。
◆ For guide vane feedback channel, when guide vane is full closed, input the sampling
value for the guide vanefeedback channel into the "Zero Setup"; when guide vane is full open,
input the sampling value for the guide vane feedback channel into the "Full Setup". The setup
for "Lower Sampling Limit" shall be lower than that of "Zero Setup", the setup for "Higher
6-14
调速器人机界面
HMI for Speed Governors
Sampling Limit" shall be higher than that of "Full Setup". The "Lower Output Value" is set as
0, the "Higher Output Value" is set as 9999, indicating the guide vane opening scope of
0~99.99%.
◆ 设输入信号为 x,输出信号为 y,则输入和输出信号之间的线性对应关系如下:y=
{(x-全关采样)/(全开采样-全关采样)}。所得数值 y 为 0~100%的变量,如:机组有功
功率则需要乘以机组的额定有功功率才能与真实的有功功率匹配。
◆ To set the input signal as x, the output signal as y, then the linear relation between input
and output signals are as follows: y={(x-full-closed sampling)/(full-open sampling-full-closed
sampling)} The value y obtained is the variable of 0~100%, for instance, the active power of
the unit shall be multiplied with the rated active power of the unit in order to match with the
actual active power.
※注意:调速器参数设置页面可以修改备用机模拟通道参数,每套控制器的模拟量通道参数都为单
独一页面,页面左上角有 A\B 机标志提示,切勿修改非当前机的模拟量通道参数。
Note: the parameter setting screen for speed governors can modify the analog channel parameters for
the standby controller, with the parameters for each controller on a separate screen. There is a
Controller A/B mark in the top left-hand corner of the screen, please do not modify the analog
channel parameters of the non-current controllers.
6.3.4 试验界面
本页中包含调速控制系统中的各个关键给定值设置和操作模式、驱动设备的切换功
能。
The page includes setup for each key setting for the control system of speed governors,
operation mode and switching of drivers.
6-15
调速器人机界面
HMI for Speed Governors
图 6.3.4-1 试验设置
Figure 6.3.4 -1 Test Setup
◆ 模式切换 当机组处于发电运行且机组出口断路器合闸之后,机组频率偏差在频
率死区以内时,允许使用运行模式切换的功能,选择相应的功能后,调速器会切换到相
应的运行模式。
◆ Mode switch: when the unit is in generating operation and the outlet circuit breaker is
closed, the unit frequency deviation is within the frequency dead-band, the operation mode
switch is allowed. After choosing the corresponding functions, the speed governor can switch
to the corresponding operation mode.
在“功率模式”运行时,则“功率给定”有效,设置一个不同于机组当前有功功率的给
定值,调速器会自动完成调节,使得实际的有功功率调节至给定值。
When operating in "power mode", the "power setting" is valid. When giving a setting
different from the current active power of the unit, the speed governor shall complete the
regulation automatically, with the actual active power regulated to the setting.
6-16
调速器人机界面
HMI for Speed Governors
在“开度模式”运行时,则“开度给定”有效,设置一个不同于当前开度的给定值,调
速器会自动完成调节,使得实际的导叶开度调节至给定值。
When operating in "opening mode", the "opening setting" is valid. When giving a setting
different from the current opening setting, the speed governor shall complete the regulation
automatically, with the actual guide vain opening regulated to the setting.
在“频率模式”运行时,则调速器会自动调节导叶开度,使得机组频率调节至给定值。
When operating in "frequency mode", the speed governor shall regulate the guide vain
opening automatically, with the unit frequency regulated to the setting.
※注意:机组处于发电运行且“频率模式”工作时,调速器的调节作用是减缓机组频率远离额定频率
的,但不能使得机组频率完全等于额定频率,因此调速器在这种工况下的调节频率高,机械损耗大,
应该尽可能地避免机组在这种工况下的运行。
※Note: when the unit is in generating operation and "frequency mode", the regulation role of the
speed governors is to keep the unit frequency not far from the rated frequency, but not completely
equal to the rated frequency. Therefore, the speed governor is high in regulation frequency and great
in mechanical loss under such working conditions. It shall try to avoid operate the unit in such
working conditions.
◆ 驱动设备切换 本系统由伺服电机+比例阀构成冗余的电液转换器件,设备运行自
动运行过程中,控制器会根据电液转换器件的工作状态自动选择,无需人为干预。试验
电液转换器性能时,可以人为选择电液转换器。
◆ Driver switch: the system shall consist of servomotor+ proportional valve, which form
the redundant electro-hydraulic converter, when the equipment is in automatic operation, the
controller can select the working status for the electro-hydraulic converter automatically, with
no artificial interference. When testing the performance of the electro-hydraulic converter, it
can manually select the electro-hydraulic converter.
◆ 水头切换 调速器的运行水头可以设置为人为给定,也可以选用自动水头。
切换为自动水头时,调速器根据 AD 通道采集的蜗壳出口压力和引水管压力插值得到机
组运行的净水头;切换为人工水头时,则可以通过“水头给定”将当前的净水头直接下发
到控制器内。
◆ Water head switch: the operational water head of speed governors can be set both as
manual settings and automatic settings. When switching to the automatic water head, the
speed governor can get the net water head for unit operation based on the spiral case outlet
pressure and the pressure interpolation of diversion pipes collected by AD channel; when
6-17
调速器人机界面
HMI for Speed Governors
switching to the artificial water head, it can send the current net water head directly to the
controller via "water head settings".
◆ 开度死区设置 ——开度死区设置的数值在调速器处于“开度模式”或者“功率模
式”运行时有效,默认设置为 0.2%。
◆ Opening dead-band setup ——the values set for the opening dead-band is valid
when the speed governor is in "opening mode" or "power mode", with a default of 0.2%.
◆ 一次调频频率死区——根据电网的要求设置一次调频频率死区,默认值 0.04Hz
◆ Frequency dead-band of primary frequency regulation——to set the frequency
dead-band of primary frequency regulation according to the grid, with a default of
0.04Hz.
◆ 功率死区 ——调速器处于“功率模式”运行时功率死区设置有效,默认为
2%Pn
◆ Power dead-band——the setup for power dead-band is valid when the speed
governor is in "power mode", with a default of 2%Pn
◆ 一般频率死区 ——调速器处于发电运行但一次调频功能未投入的情况下,一般
频率死区设置有效,默认值为 0.2Hz
◆ General frequency dead-band ——when the speed governor is in generating
operation but the primary frequency regulation is not used, the setup for general
frequency dead-band is valid, with a default of 0.2Hz
◆ 实验手动模拟量给定——试验手动操作功能投入时,可以选择直接下发实验手动模
拟量给定,方便测试随动系统的控制性能。
◆ Test manual analog setting ——when using the test manual operation, it can
choose to send the test manual analog settings directly, which can facilitate the control
performance of the test follow-up system.
◆ 开度给定 ——调速器处于开度模式且自动调节时,改变开度给定数值可以
直接改变接力器的位置,调速器在开度模式下的调节稳定值至开度给定值。
◆ Opening setting——when the speed governor is in opening mode and can be
regulated automatically, it can directly change the servomotor position by changing the
opening setting, with the stable value for speed governors in opening mode regulated to
be the opening settings.
◆ 功率给定 ——调速器处于功率模式且自动调节时,改变功率给定数值可以
6-18
调速器人机界面
HMI for Speed Governors
使得调速器操作接力器位置,进而调整机组的有功功率值。
◆ Power setting ——when the speed governor is in power mode and can be
regulated automatically, it can change the position of the servomotor for speed governors
by changing the power settings, which further regulates the active power value of the
unit.
◆ 频率给定 ——调速器处于空载且频率模式运行时,改变频率给定值可以使
得机组频率向给定值的方向变化。
◆ Frequency setting ——when the speed governor is in both no-load and
frequency mode operation, it can change the unit frequency approaching to the settings
by changing the frequency settings.
6.3.5 故障、事件记录
在功能切换区域点击“故障”按钮进入。此页上记录了当前正在发生的故障和发生过
的历史故障。
To click "Failure" button to enter this screen in the function switching zone. The screen
records the failures currently occuring and the historic failures previously occured.
◆ 点击“故障”标签进入故障显示页,故障显示页的左边是实时故障记录,右边是历史
故障记录。
◆ To click "Failure" button to enter the failure presentation page. The real-time failure
record is on the left with the historic failure record is on the right.
◆ 当操作面板上的“故障”指示灯点亮时,“当前故障”信息里将会出现实时的故障信息。
◆ When the "Failure" indicator lamp on the operation panel is on, the "Current Failure"
information can display the real-time failure information.
◆ 当调速器运行过程中出现故障而迅速复归之后,可以在“历史故障记录”里面提取到
“故障记录”,以了解故障发生的时间和复归的时间。配合“事件记录”可以查看调速
器的运行状态的转换,以便于确定故障发生的原因。
◆ When a failure occurs to the speed governor during operation and the failure is recovered
rapidly, it can find the "failure record" in the "Historic Failure Record" to learn about the
time of occurrence and recovery of the failure. The operation status switchover of the
speed governor can be reviewed with the help of "Event Record", which can facilitate the
6-19
调速器人机界面
HMI for Speed Governors
causes.
图 6.3.5-1 故障记录页面
Figure 6.3.5 -1 Failure Record Screen
6-20
第七章
Chapter 7
调速器柜体和传感器安装
Installation of Governor
Cabinet and Sensor
7-1
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
7-2
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
7.1. 概述 General
本章节包括有调速器储存、运输和安装的说明。这些说明是为有资格进行电气设备
安装人员编写的。安装人员必须熟悉这些文件和电力设备安装安全规程。
This chapter describes the storage, transportation and installation of governor. These
instructions are compiled for the disqualified personnel for electrical installations. The
installation personnel should be familiar with the documents and master the safety regulations
for electrical installation.
在整个安装、调试和维护工作期间都必须遵循有关的安全指导。在开始进行安装工
作之前必须阅本章节的相关内容,需特别注意其中的安全注意事项。
※警告:
※ Warning:
在开始一项工作之前必须认真阅读相关的电源回路图!
Read carefully the relevant power circuit diagram before a piece of work!
安装过程中可能需要一些临时电源,如照明、电动工具的电源等,应特别小心
这些临时电源!
Please be careful with some temporary power supply such as that of lighting and
electric tools that may be required in installation!
调速器通电后时,连接试验端子必须参考调试规程!
When the governor is energized, be sure to connect the test terminal according
to the debugging regulation!
静电放电可能引起电路损坏,接触电子元件时必须配戴防静电手套!
7-3
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
As the static discharge may cause damages to circuit, please always wear
anti-static gloves before contacting electronic components!
7.1.2 验收 Acceptance
交货时所有的装箱都要检查,在开箱之前,先检查一下包装箱外部是否有损坏。如
果有损坏,那么就要在保险公司和制造商在场的情况下开箱检查内部设备。外部损坏情
况必须立即记录在有关运输的文件中!开箱后发现的损坏必须在一周内向保险公司和制
造商报告!
Inspect all loading boxes in delivery. Check whether there are damages external packing
cases before opening. If any damages, always open the case and inspect the internal device in
the presence of insurance company and manufacturer. Any internal damages must be recorded
in the relevant transportation documents immediately! Be sure to report the damages found
after unpacking the boxes to the insurance company and manufacturer within one week!
设备需用吊车或叉车小心地从运输工具上卸下来。当卸下包装箱的时候,必须按照
箭头指示的方向吊起,包装箱上的一系列符号是根据国家相关标准的规定标记的。当用
叉车提升和搬运包装箱时,叉车的叉子必须平行地插入包装箱的底部。为避免包装箱歪
倒,必须注意包装箱的重心(专门有符号标记)。
Unload the device carefully with crane or forklift from the transportation. Hoist the
packing case as the direction of arrow. A series of symbols on the packing case are marked
according to relevant national regulation. When the forklift lifts and handles the packing case,
its fork must insert into the bottom of packing case in parallel. To avoid the packing case
tilting, pay attention to the gravity of case (there is symbol in the gravity).
只有当设备运抵指定位置时,包装箱才能拆开。
The packing case can be opened only when the device is transported to the defined
location.
7-4
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
图 7.1.3-1 运输包装箱
※警告:调速器在运输途中绝对不得倒置或者侧放,以免损坏内部器件。
7.1.4 储存 Storage
为了避免由于存储不当引起的设备质量下降和损坏,从设备进库一直到设备出库安
装,在整个期间必须遵守相应的防范措施。
To avoid the equipment quality deterioration and destruction due to improper storage,
perform all works from equipment in-warehouse to ex-warehouse for installation in strict
accordance with preventive measures.
设备必须按原包装在室内存储,并且必须放置在货台上或木制的底架上。
The equipment must be stored in original package and put on the cargo platform or
wooden frame.
7-5
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
存储人员需对存储地点入口进行控制以及严格管理。存储库应配备适当型号的灭火
装置和材料,并且要保持其完好可用。存储库要始终保持清洁、干燥和通风,库里的安
排要合理,废物和陈旧的包装箱必须清除干净!为避免设备弄脏和损坏,必须防止小动
物和昆虫进入库内。存储对环境的要求具体如下:
The storage personnel should make strict control and management for the entrance of
storing place. Equip the suitable extinguishing plant and materials for the warehouse, and
make sure they are available in good condition. Keep clean, dry and venting in the storage.
Make arrangement reasonably. Clear up all wastes and worn packing boxes. To avoid
smearing and damaging the equipment, be sure to prevent small animals and insects coming
into warehouse. The specific environment requirements for storage are as following:
相对湿度(无允许的结露)5 % 到 85 %
※警告:调速器设备内部含有精密器件,设备必须按原包装在室内存储,并且必须
放置在货台上或木制的底架上,保持干燥。不得在室外露天存放,不得被水淋湿或者被
水淹没。
※Warning: as the governor contains precise components, the device must be stored
in original package and placed on the cargo platform or wooden frame against wet. Do
not put them in the open air. Prohibit getting wet or submerging.
为保证设备完好,应进行定期检查,至少每月进行一次。任何细微的变化都必须引
起注意,并尽可能快地纠正!检查要按下列几点进行:
Make regular inspection at least once a month for the equipment integrity. Pay attention
to any subtle changes and make corrections as soon as possible! Perform inspection of items
as following:
环境干燥
7-6
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
表面清洁
设备覆盖和密封完好
标记完好
设备外观无物理损坏
7.1.5 开箱 Unpacking
按下列步骤打开包装箱框架:
7-7
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
顶部 Top 后面 Rear
T94_0168.D
前面 Front 底部 Bottom
侧面 Side
图 7.1.5.1-1 设备/柜体的开箱
开箱后,用起重机或叉车将设备运到安装地点。设备只能放在水平的地面上!保证
开始移动的时候设备不能倾倒。设备/柜体需要从底部固定绳缆吊起(见图 3)或从顶部
固定绳缆吊起(见图 7.1.5.2-1)。
Transport the equipment with crane or forklift to the installation location after unpacking.
The equipment can be put on the horizontal ground only. Do not dump the equipment at the
beginning of moving. Fix the rope at the bottom (Figure 3) or at the top (Figure 7.1.5.2-1) and
hoist the equipment/cabinet.
从底部起吊柜体时要遵循下列几点:
7-8
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
从底部缚绳索!
确保绳索有足够的承重能力。
T94_0169.DRW
图 7.1.5.2-1 用起重机运输
用吊环运输时,要遵循下列几点:
绳索和吊钩之间的角度不得超过 120°!
7-9
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
The angle between rope and hook should not exceed 120°!
直接用框架吊起柜体是不允许的!
柜体只能放置在水平的地面上!
柜体安装后可以拆除吊环,在螺丝孔中要安装螺帽,然后用树脂密封好。
After completing the cabinet installation, remove the hanger, install the nut in the
screw hole, and seal it with resin.
※警告:调速器在吊装及运输途中绝对不得倒置或者侧放,以免损坏内部器件。
T94_0170.DRW
图 7.1.5.2-2 用吊环运输
一般情况下,设备在出厂前已按照现场安装的要求做好了相应的准备工作,包括柜
间接线、底部、侧面和顶部开孔等。安装现场的照明和通道必须保证。如果安装现场的
7-10
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
湿度很大,且温度的变化范围也很大,就容易产生凝露现象。通过安装现场加热的方法
可避免凝露现象的产生。
In general, the equipment has been prepared according to the installation requirements on
site before leaving factory, including connection between cabinets, opening pores at bottom,
side and top, etc. Provide sufficient lighting and passage for field installation. If the humidity
is high and the temperature varies greatly in the installation site, the condensation may take
place easily. Provide heating in the installation site to prevent condensation.
7.2.1 概述 General
安装柜体应当遵循下列步骤:
2. 检查 Inspect;
5. 密封 Seal
一般,设备在运输过程中分单柜包装,运输时柜子必须垂直放置!按照前面指引打
开包装箱后,参照设备布置图把柜体依次排列好。
Generally, the equipment is packed in single cabinet during transportation. Put the
cabinet vertically in transportation! After opening the package as instruction, arrange the
cabinet in proper order according to the equipment layout.
安装固定前必须仔细核对各柜体的排列位置、排列次序及前后门的布置方向。
Check the position, sequence and direction of front and rear door for the cabinets
carefully before installation.
7-11
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
7.2.3 检查 Inspection
柜体排列完毕,在没有固定之前,检查所有的门和盖板要完好,必须能够灵活地开
/关,或无扭曲变形。
After cabinet arrangement and before fixing, make sure all doors and cover plates are in
good condition and can be flexibly opened/closed or without distortion.
在电厂建筑物安装面上埋置了槽钢,设备柜体应铆焊固定在槽钢上。
There embeds U-bar on the installation surface of buildings for power plant. The
equipment cabinet should be rivet welded to U-bar.
柜体 Cabinet 槽钢 U-bar
图 6.2.4-1 基础固定
一旦柜体已排列好并可靠地固定在基础上时,吊环和螺钉可以拆掉,保存在安全的
地方。
As soon as the cabinets are arranged well and reliably fixed to the foundation, the hanger
and bolts can be removed and stored in the safe place.
7-12
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
调速器设备内部的电气连接已由制造商连接完毕,在现场安装时,当拼柜完成后,
按照图纸的指引敷设预留的导线并接到相应的端子。
The internal electric connection of governor has been completed by manufacturer. During
field installation, after cabinet assembly, lay the reserved wires and connect to corresponding
terminal according the drawings.
调速器装置与电厂其它设备的连接需由设计或安装单位实施,这包括信号回路、控
制回路和电源回路等。当选择电缆和导线时,要注意电缆要有足够的长度和如何敷设。
随着压降的增加会引起干扰增加。
The connections between governor device and other devices of power plant shall be
performed by design unit or installation unit, including signal circuit, control circuit, power
circuit etc. Pay attention to provide enough cables and the laying methods while selecting
cables and wires. With the increase of pressure drop, the interference will increase.
绑扎电缆用的电缆夹或电缆带应该安装在机箱的底部,以防电缆连接头受拉力拉得
太紧。电缆夹也用于电缆电磁屏蔽的接地。
The cable clamp or cable tie for binding should be located at the bottom of chassis so as
to avoid the cable connector pulling too tight. The cable clamp also can be used for
electromagnetic shielding grounding of cable.
1. 按压接所需长度剥去导线绝缘,剥去长度以压接后压接部分两侧导线裸露部分均匀
不大于 2mm 为宜。Strip the wire insulation as the required length for pressure connection.
It is better for the stripping length that the exposed wires on both sides of pressure
connection parts after pressure connection are not more than 2mm.
油压钳压接。If the conductor section is less than 6mm², the cold-pressure connection
7-13
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
plier can be used for pressure by manual. If the conductor section is greater than 6mm²,
on the end.
4. 将压接好的端头放入端子接线孔内或者电缆连接螺丝上,用螺丝刀拧紧端子或者扳
connection hole or into the connection screw, tighten the terminal with screwdriver or
tighten the nut with wrench. If pulling wires and no looseness, it means the connection
has done.
without damages.
在铜排连接前,用户应将铜排底部擦净,用软布将铜排的连接面彻底地擦干净。如
果连接面很脏,可以用清洁剂(例如酒精)或软刷清洁。连接面绝对不能有污垢和油脂。
用海绵橡皮垫将合适的油脂均匀地涂在接触面。但只能涂很薄的一层。处理完后立即接
好铜排。
The users should wipe clean thoroughly the connection surface and bottom of copper bar
with soft cloth before connection. If the connection surface is very dirty, the cleaning agent
(such as alcohol) or soft brush can be used for cleaning. The connection surface should not
7-14
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
have any dirties or grease. Apply the proper grease to the contact surface with sponge rubber
pad in uniform. The coating must be thin. After that, connect the copper bar immediately.
各单元电气连接的螺钉,必须按照下表规定的力矩拧紧。但是,它们应当预先在接
触处涂以润滑油脂。
The bolts for each electric connection must be tightened at the specified torque in the
following table. However, there should apply the grease at the contacting surface in advance.
螺钉尺寸:
Bolt dimension: M5 M6 M8 M10
M12 M16 M20 M24
扭矩(Nm):
Torque (Nm) 2.2 3.7 9 18.8
31.2 75.5 152.5 146.2
铜缆和铜排的连接在下列图中详细说明 :
The detailed connections for copper cable and copper bar are described in the following
figure:
图 7.3.2-1 电缆连接
主要接地铜排应安装在柜子的底部,主要接地电缆采用螺钉连接到接地铜排。
7-15
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
The main grounding copper bar should be installed at the bottom of cabinet. Connect the
main grounding cable to grounding copper bar with screws.
T94_0186.drw
图 7.3.3-1 接地铜牌
Gear device
The crank arm of gear probe bracket is
Best detection distance projecting
paralleled with the projecting surface of
2.5mm-4mm Proximity switch
gear device.
Fixing nut for proximity
switch – a pair
Probe bracket
图 7.3.4-1 齿盘接近开关的安装
Figure 7.3.4-1 Installation of Proximity Switch of Gear
如图,齿盘接近开关在安装时应首先固定支架,使得支架的拐臂和齿盘装置的凸起
面平行,然后将接近开关穿过支架上的安装孔,调节接近开关固定螺帽,使得接近开关
7-16
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
Move
Fixing Fixing
Pull lever bracket bracket Sensor
Nut
Detected Cable
piece Base
图 7.3.4.2-1 拉杆式直线位移传感器安装
Figure 7.3.4.2-1 Installation of Linear Rod Displacement Sensor
7-17
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
图 7.3.4.2-2 拉杆式直线位移传感器的万向节
Figure 7.3.4.2-2 Cardan Joint of Linear Rod Displacement Sensor
如图所示,将传感器的电缆连接好,通电,未安装之前先拉动拉杆,确认传感器输
出信号正常,在拉杆或者滑块上做标记标定传感器的有效工作范围。安装直线位移传感
器之前应首先将传感器的安装底座固定在接力器本体上或着其它位置固定、可靠的地
方,底座安装完毕,用 M5 的螺丝穿过固定架的螺丝孔将传感器本体安装在底座上,固
定架处螺丝暂时不要上紧。将传感器的拉杆拉出,拉动拉杆上的万向节接头,观察拉杆
在导叶接力器开关全行程内能否平滑地移动,确保接力器全关时拉杆不顶撞本体,全开
时拉杆不拉拽本体。此时用螺母将拉杆与接力器上的牵引部分连接固定,然后用手扶住
传感器本体,联系操作人员缓慢操作接力器开关,确保接力器全关时拉杆相对零点(即
传感器输出信号零点 0V/0mA/4mA)为正,接力器全开时拉杆相对传感器输出全行程点
(10V/5V/20mA)为负,此时再上紧固定架。
As shown in the figure, connect the sensor cable and power it on; pull the rod before
installation; make sure the output signal of sensor is normal; mark the effective working range
of sensor on the rod or slider. Before installation of linear displacement sensor, fix the
mounting base of sensor to the servomotor body or to other secure and reliable place. After
that, pass the M5 screw through the screw hole of securing bracket and secure the sensor to
the mounting base. Do not tighten the screw at the securing bracket position for the time
being. Pull out the rod of sensor, and pull the cardan joint on the rod. Observe that whether
the rod can move smoothly in the full stroke of guide vane servomotor, make sure the rod
does not go against the body at the full closing of servomotor and not pull the body at the full
opening of servomotor. At this time, secure the pull rod with the traction part of servomotor
7-18
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
with screw. Hold the sensor body and contact the operator to operate the servomotor switch,
make sure the relative zero (i.e. the zero of output signal of sensor is 0V/0mA/4mA) of pull
rod at full closing of servomotor is positive and the output full-stroke of sensor for pull rod at
the full opening of servomotor (10V/5V/20mA) is negative. Then, tighten the securing
bracket.
现场加工的传感器底座必须有足够的强度,传感器底座以及牵引支架的加工材料应
该为厚度不小于 5mm 的钢板。
The sensor base fabricated on site must have enough strength, and the sensor base and
traction bracket should be the steel plate with thickness not less than 5mm.
注意:如果采用拉绳传感器,在拉绳被拉开之后不允许突然放手,防止传感器损坏。
Note: if the cord sensor is adopted, do not release the cord suddenly to avoid damaging
the sensor.
带有引出的线的传感器,连接至控制柜或端子箱时必须采用导线焊接的方式连接。
导线焊接前要用剥线钳除去末端绝缘层,去绝缘层时要注意对单股线不应伤及导线,多
股线及屏蔽线不断线,否则将影响接头的质量。
Connect the leading wire of sensor to the control cabinet or terminal box in the wire
welding way. Remove the insulation barrier at the end with a wire stripper before wire
welding. Pay attention not to damage the wire of single-stranded cable and not to break the
multi-stranded cable and shielded wire, otherwise it will affect the connecting quality.
导线之间的连接采用绕焊方式,操作步骤如下:
Connect the wires with contour welding, and the operating procedures are as following:
去掉两侧被焊接导线一定长度绝缘皮并在线头上锡,并穿上合适的绝缘套管。 绞
合导线,施焊。 趁热套上绝缘套管,冷却后套管固定在接头上,待焊接处完全冷却后
以绝缘胶带缠绕。
Remove a length of insulation barrier on the welding lead of both sides, and add the
proper insulating sleeve. Strand the wires and make welding. Put on the insulation sleeve
when it is hot. After it becomes cold, secure the sleeve to the connector. Bind it with
insulating tape until the welding location cools off absolutely.
7-19
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
Bind the thin wire to the thick wire and make welding Bind and weld the wires with same size
图 7.3.4-1 导线绕焊
7.4 密封 Sealing
根据设计和要求的防护等级,在柜体底架和基础的交接处必须用密封垫密封。
According to the prevention grades in the design and requirements, the joint between
cabinet under-frame and foundation must be sealed with sealing gasket.
※警告:如果可能有害虫或污垢进入柜内,在调试后,敞开的基础必须密封好!
※Warning: If there may be pests or dirties entering into cabinet, be sure to seal the
open foundation after debugging!
将所有的运输工具都拿开,例如设备里的木支撑等(如果有的话)。
Remove all transportation tools such as wooden support in the equipment (if any).
把身边所有不用的东西都清掉,例如包装用的材料或柜内的小段电缆等。
Clear out all the unused things such as material used for packing or small cable in the
cabinet etc.
用一块防静电的布将绝缘部分擦净,不要用任何的溶剂!
Wipe clean the insulating section with one anti-static cloth. Do not use any solvent!
7.6 检查 Inspection
◆ 检查基座的固定。
◆ 检查设备的防护等级是否满足,特别注意底盘和柜体顶部的电缆入口处。
7-20
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
◆ Make sure the prevention grad is satisfied, in particular the cable access at chassis
and cabinet top;
◆ 一般查看:外观、完整性、标记、外来异物、清洁度。
◆ 检查电缆的连接和配线。
◆ 屏蔽电缆在柜体的入口处正确接地,导叶开度反馈电缆在传感器一侧接地。
◆ Make correct grounding of shielded cable at the cabinet entrance, and the feedback
cable of guide vane opening is grounded at the sensor;
◆ 所有的保护导线连接正确。
◆ 关闭柜门。
如果安装和配线工作中断时,做好下面的工作以保护设备不脏、不受潮和有外来的
异物:
If the installation and wiring work is interrupted, the following work should be provided
to prevent the equipment from being dirty and affected by damp or foreign matters;
◆ 关闭柜体所有的柜门。
◆ 用塑料布盖好柜体。
◆ 在安装地点加热或连接柜内的加热器(如果已安装)。
◆ Provide heating at the installation place or connect the heater inside of cabinet (if
any).
7-21
调速器柜体和传感器安装 Installation of Governor Cabinet and Sensor
安装过程中,若发现调速器设备内部有器件在运输及安装过程中受到损坏,应尽快
联系生产厂家,协调修复或提供相应的备件。
If the internal components of governor are damaged during transportation and installation,
please contact the manufacturer immediately to remedy or provide the spare part accordingly.
在运输和安装期间,对设备表面的油漆的任何损坏,在调试前必须修复。
If any paints on the equipment surface are damaged during transportation and installation,
be sure to repair it before debugging.
只有聚亚安酯油漆可以用来修复损坏的油漆表面,因为只有它可以保证完全地附着
在原来的漆面上。
Only the polyurethane paint can be used to repair the damaged paint surface, because
only the paint can adhere to the original paint completely.
用细毛刷可以修复擦痕和裂纹。
柜体前门的油漆如果大面积的损坏,这时整个门都要重新刷漆。
If a large area paints on the front door are damaged, the entire door have to be re-painted.
7-22
第 八 章
Chapter 8
调速器运行操作说明
Governor Operation
Instructions
8-1
调速器运行操作说明 Governor Operation Instruction
8.3 来自远方操作的指令定义 Definition for the commands from remote operation ...... 11
8-2
调速器运行操作说明 Governor Operation Instruction
8-3
调速器运行操作说明 Governor Operation Instruction
8.1 概述 General
调速器接收监控系统、电柜面板操作和人机界面操作的指令,并对这些指令做出响
应。本章将详细介绍电柜面板操作与监控系统指令,以及调速系统在日常及大修后的检
查巡检内容作出一些规定。
The governor receives instruction for monitoring system, cabinet panel operation and
human-machine interface operation, and makes response for these instructions. This chapter
will make detailed introduction of cabinet panel operation and monitoring system instruction,
and give some regulation for the patrol inspection items of governing system in the daily work
and overhauls.
调速器电柜面板操作区域也是实现人机交互的一种方式,通过电柜面板的操作可实
现调速器运行状态切换,手动开停机及负荷增减,并可实现手动/自动运行之间无扰切换。
通过面板上指示灯和仪表显示可查看调速系统当前运行状态的各主要数据。
The cabinet panel operating area of governor is one way to realize human-machine
interaction. Through the cabinet panel operation, it is able to achieve operating status
switching, manual startup/shutdown and load increase/decrease, and realize uninterrupted
switching over between manual and automatic operation. On the panel indicator lamp and
meter display, the main data of current operating status for regulating system can be reviewed.
电柜控制面板分为四个部分:(※具体参考随机图纸--电柜面板布置图)
The control panel of cabinet includes four areas: (※Details refer to random drawing –
Cabinet Panel Arrangement)
◆ 表计显示部分 Metering display area
◆ 指示灯显示部分 Indicator lamp display area
◆ 面板操作部分 Panel operating area
◆ 人机界面部分 (※具体参考本手册第六章《调速器人机界面》)Human-machine
interface area (※Details refer to Chapter 6 Human-machine Interface of Governor
in the manual)
8-4
调速器运行操作说明 Governor Operation Instruction
导叶开度表: 显示当前机组导叶开度。
Guide vane opening meter: display the guide vane opening of current unit
桨叶开度表(双调节型机组): 显示当前的桨叶开度。
Paddle opening meter (dual-governor units): display the current paddle opening
机组频率/转速表: 显示当前机组频率/转速百分比。
Frequency/revolution meter of unit: display the frequency/revolution of current unit
机组有功功率表: 显示当前机组的有功功率,调速器调相运行或
者抽水运行时允许出现负值。
Active power meter of unit: display the active power of current unit. The
negative value is allowed for governor at phasing operation or pumping operation.
导叶开限表:(选配) 显示当前的电气开限值。
Opening limit meter of guide vane (optional): display the current electric opening
limit
油压表:(选配) 显示调速系统(或者压力罐)压力。
Oil pressure meter (optional): display the pressure of governing system (or
pressure tank)
◆ 锁定退出灯:当机械锁定在退出位置时,该指示灯点亮。
◆ Locking OUT lamp: when the mechanical locking is in OFF position, the indicator
lamp will be on.
◆ 锁定投入灯:当机械锁定在投入位置时,该指示灯点亮。
◆ Locking ON lamp: when the mechanical locking is in ON position, the indicator
lamp will be on.
◆ 事故指示灯:当调速器报严重故障时,该指示灯点亮。
◆ Accident indicator lamp: when serious fault occurs to the governor, the indicator
lamp will be on.
◆ 故障指示灯:当调速器报一般故障时,该指示灯点亮。
◆ Fault indicator lamp: when common fault occurs to the governor, the indicator lamp
will be on.
◆ A 套主用指示灯:当调速器 A 机控制处于“主用状态”时,该指示灯点亮。
8-5
调速器运行操作说明 Governor Operation Instruction
◆ Active Controller A main indicator lamp: when the speed governor controller A is at
“active status”, the indicator lamp will be on.
◆ B 套主用指示灯:当调速器 B 机控制处于“主用状态”时,该指示灯点亮。
◆ Active Controller B main indicator lamp: when the speed governor controller B is at
“active status”, the indicator lamp will be on.
◆ 导叶手动指示灯:当调速器导叶控制处于“机手动模式”时,该指示灯点亮。
◆ Manual indicator lamp for guide vane: when the guide vane controller of the speed
governor is at “manual mode”, the indicator lamp will be on.
◆ 导叶自动指示灯:当调速器导叶控制处于“自动模式”时,该指示灯点亮。
◆ Auto indicator lamp for guide vane: when the guide vane controller of the speed
governor is at “automatic mode”, the indicator lamp will be on.
◆ 桨叶手动指示灯:当调速器桨叶控制处于“机手动模式”时,该指示灯点亮。
◆ Manual indicator lamp for paddle: when the paddle controller of the speed governor
is at “auto manual mode”, the indicator lamp will be on.
◆ 桨叶自动指示灯:当调速器桨叶控制处于“自动模式”时,该指示灯点亮。
◆ Auto indicator lamp for paddle: when the paddle controller of the speed governor is
at “automatic mode”, the indicator lamp will be on.
※桨叶部分指示灯仅双调节型调速器配置。
※Paddle indicator lamp is only for dual-regulating governor.
※导叶或桨叶自动指示灯闪烁时,调速器处于导叶或桨叶试验手动状态,在投
入运行前必须通过人机界面或者柜内试验手动按钮将试验手动复归。
※When the auto indicator lamp for guide vane or paddle flickers, the speed
governor is at the test manual status of guide vane or paddle. Before putting into
operation, make sure to reset the test manually through the human-machine
interface or manual testing button in cabinet.
电柜面板操作旋钮/按钮:A/B 机切换旋钮、导叶手自动切换旋钮、现地/远方切换旋
钮、导叶开度增加/减少旋钮、紧急及复归按钮、桨叶手自动切换旋钮(双调型机组配置)、
桨叶开度增加/减少旋钮(双调型机组配置)、功率/开度切换模式旋钮(选配)、开限增
减/减少旋钮(选配)。
Cabinet panel operating knob/button: Controller A/B switching knob, auto/manual
8-6
调速器运行操作说明 Governor Operation Instruction
switching knob for guide vane, local/remote switching knob, guide vane opening
increase/decrease knob, emergency and reset button, auto/manual switching knob for paddle
(for dual-regulating unit), paddle opening increase/decrease knob (for dual-regulating unit),
power/opening switching knob (optional), opening limit increase/decrease knob (optional).
◆ A/B 机切换旋钮:调速器不存在大故障的前提下,调速器切至主用机工作时,
对应主用机指示灯点亮。
◆ Controller A/B switching knob: if there are no major faults in the speed governor, it
switches to active status, and the corresponding active indicator lamp will be on.
◆ 导叶手自动切换旋钮:调速器不存在大故障的前提下,调速器切至自动运行工
况,导叶自动运行指示灯点亮;调速器切至手动运行工况,导叶手动运行指示
灯点亮。
◆ Auto/manual switching knob for guide vane: if there are no major faults in the speed
governor, when the governor is switched to automatic operating status, the auto
operation indicator lamp for guide vane will be on; when the governor is switched to
manual operation, the manual operation indicator lamp for guide vane will be on.
※ 注意:导叶手动按钮的操作权限为最优先级,一旦切至导叶手动操作,比例阀
或电机等电气执行机构将无法操作引导阀,调速器纯机手动运行时,无法进行
自动调节,需要操作把手才能动作接力器,调速器切手动运行之后应有专人监
护设备。
※ Note: the manual button of guide vane has top priority. Once the guide vane is
in manual operation, the proportional valve, motor or other electric actuator is
unable to operate the pilot valve. When the governor is at the manual operation
only, it is unable to make auto regulation and requires handle operation to
activate the servomotor. Arrange specific person to monitor the device after the
governor is switched to manual operation.
※ 相应的实验手动按钮存在于柜内,只有在调速器自动及现地操作条件下,投入
实验手动按钮有效,调速器手动状态投入实验手动按钮无效;一旦投入实验手
动按钮,调速器自动等闪烁,当调速器切远方运行时,调速器自动切换到自动
状态运行,在完成实验手动操作时,必须复归实验手动按钮。
※ The corresponding test manual button is inside of cabinet. Only when the
governor is at automatic and local condition, the test manual button can be
effective, and the test manual button is invalid if the governor is at manual
8-7
调速器运行操作说明 Governor Operation Instruction
status. Once the test manual button is on, the corresponding indicator lamp of
the governor flickers. When the governor is at remote operation mode, it
switches to auto operation automatically. After completing manual testing
operation, make sure to reset the test manual button.
◆ 现地/远方切换旋钮:现地控制仅对电柜操作有效,远方控制时 LCU 操作有效。
◆ Local/remote switching knob: the local control is valid for cabinet operation only,
and the remote control is valid for LCU operation.
◆ 导叶增/减旋钮:现地控制有效时,可以通过操作导叶增/减旋钮增大/减少导叶开
度给定值,从而达到调整导叶开度的目的。导叶增/减的速度可以通过触摸屏上
的增/减速度进行设置,设置范围为 1%/s—20%/s 操作增/减旋钮时应点动操作。
◆ Guide vane opening increase/decrease knob: when the local control is effective, it is
able to increase/decrease the guide vane opening value by the guide vane opening
increase/decrease knob so as to adjust the guide vane opening. Make setting of
increase/decrease speed by the touch screen, and the setting range is 1%/s – 20%/s.
Operating the increase/decrease knob by clicking.
◆ 紧急停机按钮:紧急停机按钮在必要时才可进行按压操作,这将导致机组紧急
事故停机,可能会对机组的设备产生损坏,其操作必须慎之又慎。紧急停机按
钮带保护盖,当且仅当机组发生紧急故障时可以掀开保护盖,按下此按钮。按
下此按钮之后,比例阀/电机的控制不再发挥作用,调速器将会以最快速度关闭
导叶。
◆ Emergency shutdown button: the emergency shutdown button can be operated if
necessary. This will lead to emergency accidental shutdown and may cause damages
to equipment. Be careful for the operation. The emergency shutdown button has
protective cover. If and only if there is emergency fault for the units, the protective
cover can be removed for pressing button. After pressing the button, the proportional
valve/motor control will not affect any more, and the governor will close the guide
vane at the top speed.
◆ 紧急停机复归按钮:当机组故障原因查明并排除之后,在开机之前可以按下紧
急停机复归按钮,使得控制油路恢复正常工作状态。
◆ Reset button for emergency shutdown: when the fault is detected and removed, press
the reset button for emergency shutdown before startup so as to recover the oil
circuit to normal condition.
8-8
调速器运行操作说明 Governor Operation Instruction
※注意:手动操作此紧急停机复归按钮(或机械装置紧急停机复归电磁阀)时,运
行人员必须确认调速器在停机备用状态或调速器为手动运行态。
※Note: While operating the reset button for emergency shutdown manually (or
mechanical device shutdown emergently and resets electromagnetic valve), the
operators should make sure the governor is at shutdown as standby or manual
operation status.
◆ 桨叶手自动切换旋钮(双调节型机组):调速器不存在大故障的前提下,桨叶切
至自动运行工况,桨叶自动运行指示灯点亮;桨叶切至手动运行工况,桨叶手
动运行指示灯点亮。
◆ Auto/manual switching knob for paddle (for dual-regulating unit): if there are no
major faults in the governor, when the paddle is switched to automatic operating
status, the auto operation indicator lamp for paddle will be on; when the paddle is
switched to manual operation, the manual operation indicator lamp for paddle will
be on.
◆ 桨叶增/减旋钮(双调节型机组):现地控制有效时,可以通过操作桨叶增/减旋
钮增大/减少桨叶开度给定值,从而达到调整桨叶开度的目的。桨叶的增减速度
调整范围是 1%/s—15%/s。
◆ Paddle opening increase/decrease knob (for dual-regulating unit): when the local
control is effective, it is able to increase/decrease the paddle opening value by the
paddle opening increase/decrease knob so as to adjust the paddle opening. The
regulating range for increase/decrease speed of paddle is 1%/s – 15%/s.
◆ 功率/开度切换模式旋钮(选配):此按钮仅在机组并网负载下操作有效,并且功
率故障时,操作旋钮无效。
◆ Power/opening switching knob (optional): this button is valid only when the units are
connected into grid and with loading. When the power is failed, it is invalid to
operate the knob.
◆ 开限增减/减少旋钮(选配):此按钮仅在现地下操作有效,调速器实验电自动下
调节范围 0-100%,调速器自动态下如出现一些特定故障或调速器为停机等待状
态,此旋钮操作无效。
◆ Opening limit increase/decrease knob (optional): this button is valid only at local
operation. At the auto testing state, the regulating range for speed governor is
0-100%. If some specific faults occur or the governor is at shutdown delay state, it is
8-9
调速器运行操作说明 Governor Operation Instruction
◆ 现地/远方切换旋钮操作的定义:
◆ Definition for operation of local/remote switching knob:
远方操作指接收来自监控系统指挥命令,现地操作指接受来自电柜(包括机械
柜)、人机界面命令。
Remote operation means to receive the commands from monitoring system; local
operation means to receive command from cabinet (including mechanical cabinet)
and human-machine interface.
◆ 现地/远方操作对监控命令闭锁的定义:
◆ Definition for monitoring commands blocking by local/remote operation:
监控系统下发投切一次调频功能命令、远方增加令、远方减少令、远方频率模
式切换命令、远方开度模式切换命令、远方功率模式切换命令,这些命令仅在
调速器远方操作时有效;
The monitoring system issues the primary frequency control on/off command,
remote increasing command, remote decreasing command, remote frequency mode
switching command, remote opening mode switching command and remote power
mode switching command. These commands are valid only when the governor is at
remote operation.
监控系统下发开机令、停机令、并网令、调相令、锁定投入令、锁定拔出令、
导叶手/自动操作令、桨叶手/自动切换令、主备用切换令,这些命令不受现地/
远方的闭锁,即无论调速器现地操作还是远方操作都有效。
The monitoring system issues startup command, shutdown command,
grid-connecting command, phase modulation command, locking input command,
locking output command, manual/auto operating command for guide vane,
manual/auto switching command for paddle and active/standby switching command.
These commands are not blocked by local/remote operation. That is to say, both
local and remote operation is valid for the governor.
◆ 现地/远方操作对电柜(包括机械柜)、人机界面命令闭锁的定义:
◆ Definition of blocking commands for cabinet (including mechanical cabinet)
8-10
调速器运行操作说明 Governor Operation Instruction
调速器处于自动控制状态,调速器才会对监控系统的控制指令做出响应。
When the governor is at the auto control state, it can make response to the control
commands of monitoring system.
调速器开机令 机组各部分工作正常且具备开机条件时,监控系统按照机组
开机流程依次下发各个设备的启动命令,当执行到调速器启动流程时,监控系
统向调速器发出调速器开机令(保持时间不小于 2s),调速器接到指令后,由“停
8-11
调速器运行操作说明 Governor Operation Instruction
机备用态”转为“开机过程态”,满足空载条件,开机流程结束调速器转为“空载
态”。
Governor startup command: when the components of unit work normally and meet
the startup conditions, the monitoring system issues the startup command to each
device as the starting process of unit. If it is turn for the governor to start, the
monitoring system sends the startup command (maintain the time not less than 2s) to
the governor. When the governor receives the command, it switches from “shutdown
as standby” to “in-startup” so as to meet the no-load condition. After it starts up, the
governor switches to “no-load”.
调速器停机令 运行人员根据调度要求执行机组停止,监控系统依次向各个
设备下发停机令,执行到调速器停机流程时,调速器接停机令转为停机过程,
快速关闭导叶,直至导叶全关。如果调速器接停机令时机组仍处于发电状态,
则调速器将会按照导叶减小缓慢的速率将导叶关闭到空载开度附近,待“机组出
口断路器合闸”消失之后,再将导叶完全关闭。
Governor shutdown command: the operators stop the unit as dispatching
requirements, and the monitoring system issues the startup command to each device
as the starting process of unit. If it is turn for the speed governor to stop, the
governor converts the shutdown command to the stopping process, closing the guide
vane rapidly till it is closed completely. If the unit is still in generating state while
the governor receives the shutdown command, the governor will close the guide
vane until approaching to the no-load opening according to the decreasing speed of
guide vane. When the “closing unit outlet circuit breaker” disappears, it will close
the guide vane completely.
调速器增速/减速 机组处于空载运行时,为使得机组更快地并入大电网运行,
同期装置将向调速器下发增速/减速指令,此时调速器将根据增速/减速令的信号
连续地开/关导叶,使得机组频率快速地向电网频率接近,以满足并网的需求。
一般情况下,增速/减速引起的调速器频率波动不超过 50±0.5Hz。
Governor acceleration/deceleration: when the unit is in no-load operation, the
synchronization device will send acceleration/deceleration command to the governor
so that the unit can be connected to large grid more quickly. At this time, the
governor will open/close the guide vane continuously based on
acceleration/deceleration signal so that the unit frequency approaches to grid
8-12
调速器运行操作说明 Governor Operation Instruction
8-13
调速器运行操作说明 Governor Operation Instruction
8-14
调速器运行操作说明 Governor Operation Instruction
◆ 调速器手动信号 调速器运行状态处于手动状态,此时调速器不对测频信
号产生响应,监控系统对调速器下发的常规操作指令如“开机令”“停机
令”“增/减负荷令”等指令无效,调速器可以接收监控系统下发的紧急停机操
作指令。
◆ Manual signal of governor: when the governor is at manual state, it will not
make response to frequency measurement signal, the commands such as “startup
command”, “shutdown command” and “increasing/decreasing load command”
from monitoring system to governor is invalid, and the governor can receive the
emergency shutdown operation command from monitoring system.
◆ 调速器自动信号 调速器内部自动进行控制运算,并对接收到的指令结合
机组目前的状态进行控制操作及状态信号输出。
◆ Auto signal of governor: the governor makes internal control calculation
automatically, and makes control operation and status signal output based on the
received commands and current state of unit.
◆ 调速器主用信号 调速器处于 A 套运行还是 B 套运行。
◆ Active signal of governor: the governor is in the mode of Controller A or
Controller B.
◆ 现地/远方信号 调速器处于现地调节还是远方调节
◆ Local/remote signal: the governor is in local adjustment or remote adjustment.
◆ 开度模式 调速器的调节目标为导叶开度,调速器开度模式在自
动运行条件下接收增减命令开关导叶。
◆ Opening mode: the target for governor adjustment is the guide vane opening.
The opening mode of governor is to receive increasing or decreasing command
in automatic operation to open or close the guide vane.
◆ 功率模式 调速器的调节目标为机组功率,调速器功率模式在自
动运行条件下接收增减命令调节有功功率至功率给定。
◆ Power mode: the target for governor adjustment is the unit power. The power
mode of governor is to receive increasing or decreasing command in automatic
operation to adjust the active power until approaching to the set power.
◆ 频率模式 调速器的调节目标为频率给定值,调速器在自动运行条
8-15
调速器运行操作说明 Governor Operation Instruction
件下接收增减命令调节机组频率至频率给定。当机组出口断路器合闸且调
速器处于自动、频率模式运行时,调速器状态处于孤网运行的状态。
◆ Frequency mode: the target for governor adjustment is the set frequency. The
governor receives increasing or decreasing command in automatic operation to
adjust the unit frequency until approaching to the set frequency. When the unit
outlet circuit breaker closes and the governor is in auto and frequency mode, the
governor will be in the isolated network operation.
◆ 一次调频功能投入 当调速器处于自动运行,机组出口断路器合闸,一次
调频功能开关投入且调速器处于开度/功率模式运行时,调速器一次调频功
能投入。
◆ Primary frequency control input: when the governor is in auto operation. the unit
outlet circuit breaker closes, the primary frequency control switch is on and the
governor is in opening/power mode, the primary frequency control function for
governor will be activated.
◆ 一次调频动作 调速器一次调频功能投入之后,当机组频率越过调频
死区设定值时,调速器开始调整导叶,一次调频动作信号输出,当机组频
率从一次调频动作死区以外回复到正常频率之后,一次调频动作复归。建
议在一次调频动作之后,监控系统的有功功率调节退出;一次调频复归设
定时间之后,再投入监控的有功功率调节功能。
◆ Primary frequency control action: after the primary frequency control of
governor inputs and when the unit frequency exceeds the setting value of
frequency control dead zone, the governor starts adjusting the guide vane and
outputs the action signal of primary frequency control. When the unit frequency
recovers to normal frequency, the primary frequency control resets. It is
recommended to exit the active power adjustment of monitoring system after the
primary frequency control acts, and to activate the active power adjustment after
the primary frequency control resets.
◆ 一般故障 调速器内部元件或功能发生故障,但不影响机组的正
常运行,调速器报一般故障信号。调速器报一般故障时,调速器不进行主
用机切换,允许调速器流程顺序执行。
◆ Common failures: if there occurs failures on the internal component of governor
or functions and the failures do not affect the normal operation of units, the
8-16
调速器运行操作说明 Governor Operation Instruction
governor will send signals of common failure. When the governor is in common
failure, the switching between active and standby unit will not made, and it will
execute according to the governor process.
◆ 严重故障 调速器的故障使得主用机本身已经无法继续完成自动
控制的任务,主用机报严重故障,备用机替代原主用机成为当前主用机工
作。当调速器双套控制器出现严重故障,此时调速已经无法按照既有的流
程执行对导叶接力器的操作,需要机手动操作停止机组运行或者紧急停机。
◆ Serious failure: the governor is impossible to complete auto control due to the
failures. The active unit makes signal of serious failure, and the standby unit will
replace the active unit to complete works. When the dual-controller of governor
has serious failure, the governor is unable to make operation for guide vane
servomotor according to the existing process, which requires manual operation
to stop unit or make emergency shutdown.
1、调速系统电源正常,信号正常。
The power and signal for governing system is normal.
2、调速器人机界面的参数确认。
Confirm the parameters of human-machine interface for governing system.
3、 调速器接力器关闭与开启时间与关闭规律应符合调节保证计算要求。
The opening/closing time and closing rule for governor servomotor should meet the regulation
calculation requirements.
4、 远方及机旁开(停)机、负荷调整、事故停机等动作正确。
Remote and local startup (shutdown), load adjustment and emergency shutdown are correct.
5、机组频率信号回路和电网频率信号回路熔断器完好并已投入。
The signal circuit fuses for unit frequency and grid frequency are in good condition and have
switched on.
6、 锁锭装置动作正常、指示正确。
The locking device operates normally and indicates correctly.
8-17
调速器运行操作说明 Governor Operation Instruction
7、 调速系统用油的油质符合要求。
The oil quality for governing system meets the requirements.
8、 压力油罐油位及油压信号装置动作正常。
The oil level in the pressure tank and oil-pressure signal device are normal.
9、 油泵及阀组工作正常,运行平稳。
Oil pump and valve bank work normally and reliably.
10、急停阀及事故阀动作正常。
Emergency stop valve and emergency valve work normally.
1、开机前应确认机组已具备开机条件;
Make sure the unit is ready for startup;
2、调速器显示手动位置。
The governor is at manual position.
3、在手轮运行过程中,操作人员不得离开操作岗位。
3. During hand wheel operation, the operator should not leave the operating position.
1、退出锁定机构。
Exit the locking mechanism.
2、打开主供油阀,观察调速主配旁油压表正常。
Open the main delivery valve, and observe the oil pressure gauge nearby the main distributing
valve is normal.
3、急停阀在复归位置。
The emergency stop valve is at reset position.
4、通过手动操作机构,缓慢调整导叶开度,在开机过程中应注意观察机组转速表,防
止机组过速。
Adjust the guide vane opening slowly by manual operation mechanism. Observe the
revolution meter of unit during starting up to prevent overrunning.
8-18
调速器运行操作说明 Governor Operation Instruction
1、 手动操作机构减机组负荷至空载。
Decrease the unit load to no-load by manual operation mechanism.
2、 等待断路器跳开后,手动操作机构关闭导叶至全关。
When the circuit breaker trips off, operate the mechanism by manual to close the guide vane
until full closing.
3、 监视机组转速,当机组转速降至规定值时,对机组进行刹车。
Monitor the unit revolution speed. When the revolution speed reduces to specified value,
make braking for the unit.
4、 停机后投入锁定。
Apply locking after shutdown.
1、调速器系统在自动态时,必须确认调速器为“停机备用态”。
When the governing system is in auto state, the governor must be in “shutdown as standby”.
2、如调速器不在“停机备用态”,必须保证调速系统为手动状态。
If the governor is not in "shutdown as standby”, the governing system must be in manual
state.
1、 开机前应确认机组已具备自动开机条件。
Make sure the unit is ready for startup;
2、 调速器电气柜工作正常,并没有故障信号。
The electric cabinet of governor works normally and does not send failure signals.
2、 调速器面板操作旋钮在“自动”与“远方”位置。
The knob on the governor panel is in “auto” and “remote” position.
3、 发出开机令并监视机组自动开机过程。
Give the startup command and monitor the auto starting process of unit.
4、 调速器开机完成后,会上报“调速器空载状态”信号
After starting up, the governor will report the “governor no-load status” signal.
8-19
调速器运行操作说明 Governor Operation Instruction
1、 调速器在“自动”状态。
The governor is in auto state.
2、 根据监控命令减机组负荷至空载,调速系统等待断开发电机的出口开关并灭磁。
When the loading of unit is reduced to no-loading according to monitoring command, the
governing system will disconnect the outlet switch of the generator and make field discharge.
3、 监控发出停机令,监视机组自动停机过程。
The monitoring system issues shutdown command and monitors the auto shutdown process of
unit.
4、 停机后投入锁定装置。
Apply the locking device after shutdown.
5、 调速器停机完成后,会上报“调速器停机备用”信号
After shutdown, the governor will report “governor shutdown standby” signal.
1、 确认调速器为正常状态。
Make sure the governor is in normal condition.
2、 调速器手动或自动状态都可以进行 A/B 机切换。
Controller A/B switching of governor is available for both manual state and auto state.
3、 调速器现地或远方状态都可以进行 A/B 机切换。
Controller A/B switching of governor is available for both local state and remote state.
4、 手动操作切换旋钮,假如切换到 B 机,要按住 B 机旋钮 0.2 秒以上。
Operate the switching knob by manual. If it requires switching to B unit, press the knob of
Controller B for over 0.2 s.
5、 手动主备用切换后,观察人机界面的参数与导叶开度是否有变化。
After active/standby switching manually, observe the changes of human-machine interface
parameter and guide vane opening.
1、 由手动转到自动时,需确认调速器为正常状态,自动转手动无此要求。
The governor should be in normal state while switching from manual to auto operation.
However, this requirement is not applied for switching from auto to manual operation.
8-20
调速器运行操作说明 Governor Operation Instruction
2、 调速器手自动切换在现地与远方都可以进行切换。
Auto/manual switching of governor is available for both local state and remote state.
3、 操作手自动旋钮,切换到你想切换的状态。
Operate the auto and manual knob to obtain the desired status.
4、 切换过程,请勿频繁快速来回切换,间隔应该大于 0.5 秒以上。
Do not make switching frequently and quickly. The switching interval should be above 0.5 s.
5、 切换过后观察导叶开度是否发生变化。
Observe the changes of guide vane opening after switching.
1、 通过手动操作机构进行调整,调整时应避免机组有功进相或超负荷运行,避免机组
在震动区运行。
Make adjustment by the manual operation mechanism. Avoid active power into phase or
over-loading operation of units during adjustment, and prevent units operating in
vibration zone.
2、 自动时,可根据电站实际运行情况,设定电气开度限制,根据监控增减指令操作。
At the auto status, make settings of opening limit according to the actual operation of power
station, and perform increasing/decreasing operations as the command from monitoring
system.
3、 调速器在故障时,自动态有可能开度限制被保护功能下调,有可能无法增负荷的情
况,此时应该先恢复故障,再调高开度限制。
If the governor is failed, the protection function for opening limit may diminish, and the load
may be unable for increasing. At this time, please repair the failure first, and improve the
opening limit later.
4、 调速器减负荷到空载减不下去时,一般是由于当前水头与空载开度设置偏差大导致。
If the load decreasing of governor cannot continue to no-loading, there may be great
deviations between current water head and no-loading opening.
1、 现场运行规程应对调速器及油压装置的巡回检查、定期维护项目和要求作出规定。
The field operation standards should make stipulation for the polling inspection, regular
8-21
调速器运行操作说明 Governor Operation Instruction
8-22
调速器运行操作说明 Governor Operation Instruction
5、 定期维护:
Regular maintenance:
(1)定期进行调速器自动、手动切换及事故停机电磁阀动作试验,并检查相应动作情
况及指示是否正确。
Make auto/manual switching and electromagnetic valve testing at emergency shutdown for
governor regularly, and check that the corresponding situation and indicating are correct or
not.
(2)定期对滤油器进行切换、清洗。
Replace and clean the oil filter regularly.
(3)定期对油位、油质的检查。
Inspect the oil level and oil quality regularly.
(4)定期对调速器电柜内元件老化情况进行记录。
Record the aging situation of components in the governor cabinet regularly.
8-23
第九章
Chapter 9
调速器维护及故障处理
Speed Governor Maintenance and
Troubleshooting
9-1
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
9-3
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
9.1 概述 General
◆ 维护和运行人员必须熟悉调速器相关操作,对发出的调速器的报警和应对措施
都要熟悉。
◆ The maintenance and operation personnel must be familiar with the relevant
operation of the speed governor as well as the governor alarming and
countermeasures.
◆ 维护和运行人员需要具备应对机组事故的丰富经验,且有能力在紧急情况下关
闭导叶。
◆ 维护和运行人员必须熟悉在工作现场防止意外事件的措施。
◆ The maintenance and operation personnel must be familiar with the accident-proof
measures at the working site.
紧急情况说明
Descriptions of Emergencies
工作人员必须知道灭火器和紧急出口的位置,并且要会使用灭火器。灭火器分卤素
灭火剂、二氧化碳(CO2) 或泡沫等几种。
Workers must know the location of the fire extinguisher and emergency exit, and how to
use the fire extinguisher. The fire extinguisher is divided into halogen fire extinguishing agent,
CO2, and foam, etc.
◆ CO2 灭火器专门用于电气设备的灭火。
◆ The CO2 fire extinguisher is specially used to extinguish fire of electrical equipment.
◆ 泡沫灭火器是专门用于非电器设备的灭火。它们不能用于电气设备的灭火。
9-4
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
◆ The foam fire extinguisher is specially used for non-electrical equipment fire
extinguishing, and it shall not be used to extinguish the fire of electrical equipments.
◆ 调速系统起火时,首先切断调速系统电源,如有必要就首先动用紧急停机装置,
然后断开系统的所有的电源。
◆ Once the speed governing system is on fire, firstly cut off the power of speed
governing system, startup the emergency shutdown devices if necessary, and then disconnect
all the powers of the system.
当在带电的柜中灭火时,只能使用二氧化碳灭火器,绝不能用泡沫或水!Only the
CO2 fire extinguisher can be used to extinguish the electric cabinet! Foam or water is
never allowed.
注意:机组大修结束之后必须进行模拟试验验证调速器功能,试验条件如下
Notes: Analog test must be carried out after finishing the unit overhauling to verify
the functions of the speed governor, and the test conditions are as below:
1)蜗壳、导叶控制环等处没有人,接力器能开关动作,操作安全;
No irrelevant person nearby the spiral case or guide vane control ring, and the
servomotor shall be able to switch normally and operate safely;
2)安全闸门未吊起,即导叶打开后不至于机组转动起来。
The safety gate is not lifted, that is, the opening of guide vane will not cause unit
operation.
试验的内容简述如下:
调整和校验反馈:
9-5
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
接力器行程反馈调整:固定传感器本体,按照图纸连接传感器接头,滑动传感器的滑块
磁铁,观察传感器的输出信号在 4~20mA,避开传感器的无信号区。导叶全关时,选定
滑块位置,使得滑块运动到此为止时传感器输出信号约为 4.5mA;打开导叶至全开位置,
使得此时的传感器输出信号小于 20mA,固定传感器滑块和拉杆。
Feedback regulating of servomotor travel: fix the sensor body and connect the sensor
connector in accordance with drawing, slide the slider magnet of the sensor, observe whether
the sensor output signal is 4~20mA, and avoid the zero signal zone of the sensor. While the
guide vane is totally closed, select the slider location to make the sensor output signal being
about 4.5mA while the slider moves to the location aforementioned; open the guide vane to
total open location to make the sensor output signal less than 20mA, and then fix the sensor
slider and draw bar.
开关机时间调整:机组大修前后,必须检查记录导叶接力器开关机时间,对照调速器投
运试验报告上的数据,确保导叶接力器开关机时间符合调保计算的要求,不符合调保计
算要求的,必须重新调整导叶接力器开关机时间和机械零点。
Startup/shutdown time regulating: before and after unit overhauling, check and record the
guide vane servomotor startup/shutdown time, compare the data on the speed governor
operation test report, and ensure that the guide vane servomotor startup/shutdown time
complies with regulation & guarantee requirements, and if it fails to comply with the
regulation & guarantee requirements, readjust the guide vane servomotor startup/shutdown
time and mechanical zero.
◆ 准备工作:按照图纸在端子接上模拟的机组频率信号,检查所有参数与投运
报告上参数一致,机组蜗壳、接力器控制环等部位没有其他人员工作。
9-6
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
◆ 开始测试:按照调速器现场试验规程的要求完成模拟开机、模拟扰动、模拟
并网、模拟甩负荷和模拟停机的试验,试验结束,恢复所有接线,调速器恢复停机备用
态。
※试验设备不属于调速器设备内,需另外订购。
※The test equipments are beyond the scope of speed governor equipment and therefore
they shall be procured separately.
9.3.1 概述 General
The STDS type hydraulic turbine governor simulation test diagnosis system as R&D
independently by NENGSHIDA Electric can satisfy the demands of hydropower stations for
the speed governor test and simulation. This equipment adopts advanced DSP technology
which is better than traditional single chip microcomputer (9.6Kbps) simulator in terms of
stability and collection rate (480Mbps). The strong DSP processor make it easier for data
collection and processing, the communication interface of USB2.0 highly improves data
collection rate, especially at the time of measuring the load dump dead time, and the
collection rate of us level further improves the accuracy rating. Meanwhile, the primary
frequency modulation function is specially designed based on the demand of domestic
primary frequency modulation, making the test more convenient.
9-7
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
9.3.2 特点 Characteristics
Most of the speed governor equipments in the market only have wave recording and
analysis functions, but the STDS type product as produced by us is with the hydraulic
turbine speed governor simulation equipment with simulation function test.
仿真功能使机组不需要开机的情况下完成开机、空载、负载、停机的各种模拟实验,
也使维护运行人员在机组未开机的状态下就能进行一些故障分析及机组的所需要的
数据。
The simulation function makes the unit can finish various kinds of simulation tests of
startup, no-load operation, load operation, shutdown without the startup condition and
meanwhile help the maintenance and operation personnel carry out fault analysis and get
the data as required by the unit under the condition when the machine is not started up.
The innovational digital signal processor (DSP) is the core of the simulation, detection
and signal processing system. The application of the DSP technology effectively
improves the data collection and processing capability of the device as well as the
real-time of non-linear dynamic simulation.
◆ The universal serial bus V2.0 technology (USB2.0) is used to satisfy the fastness
requirements for the simulation test system and eliminate the mutual restriction between
the communication speed of the detection device and signal processing real-time; so it is
faster than traditional serial port for several thousand times.
非线性仿真计算模型,提高了水轮机调节系统在大波动调节过程中的仿真性能。
The non-linear simulation calculation model improves the simulation performance of the
9-8
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
◆ 采用面向环节的离散相似算法对水轮机调节系统进行仿真程序模块的设计,不仅提
高了仿真计算的精度和实时性,而且还实现了仿真计算中的基本环节组态。
DSP 系统的仿真仪运行可靠、稳定,不会随周围温度的变化产生漂移、死机等等现
象。
The simulator of the DSP system operates reliably and stably and it is free of such
defects as drift or dead halt, etc. caused by change of surrounding temperature.
◆ 便携式,重量轻(仅 3.7Kg),特别适合外出调试和试验。
◆ It is portable and light (only 3.7kg) and suitable for field debugging and test.
9.4.1 概述 General
设备投入运行后,部分电气元件存在缓慢老化现象,有些情况下可能发生物理损坏
的情况,厂房的振动可能使端子连接处或其他有螺钉连接的地方松动,所以定期检查检
测设备是必须的。
Some electrical elements may age slowly after the equipment is put into operation,
physical damage may also occur under certain conditions, the plant vibration may loosen the
terminal connection or screw connection, so it is necessary to check the detection equipment
regularly.
在进行维护工作时,应首先确认维护工作是否具备条件,不同的检查、维护项目在
不同的工作条件下进行。
While carrying out maintenance work, determine firstly whether the maintenance
9-9
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
conditions are available, and different inspection and maintenance items shall be carried out
under different conditions.
在装置投运的第一年,应严格按维护时间表执行,后期维护时间间隔可根据第一年
的观测情况做调整。如果灰尘积聚很快,则维护间隔应缩短。如果运行环境好,灰尘很
少,则维护的时间间隔可适当延长。
At the first year after the device is put into operation, carry out inspection and
maintenance strictly in accordance with the schedule, and the subsequent maintenance time
interval may be adjusted based on the observation conditions of the first year. If the dust
accumulates fast, the maintenance interval shall be shortened. If the operation environment is
good and the dust is rare, the maintenance time interval may be prolonged appropriately.
保持环境清洁,防止灰尘进入调速器。检查风机表面及叶片是否存在严重污垢,风
流是否正常,是否有不正常噪音,因为风机不方便拆开润滑转轴等,噪音明显增大时,
可考虑在下次维护时更换。拆下柜门上空气过滤网并清洗,如果空气过滤很脏,且难以
清洗时,必须更换。
Keep clean environment and avoid dust from entering into the speed governor. Check
the surface and blade of the fan to see whether there is serious dirt, whether the air flow is
normal, and whether there is abnormal noise. Since the lubricating spindle of the fan is
inconvenient to be disconnected, if the noise increases apparently, it may be replaced at the
next maintenance. Remove the air strainer from the cabinet door and clean it, if the strainer is
dirty and hard to be cleaned, it must be replaced.
机械部分维护和保养办法参考本手册第十三章。
Refer to Chapter 13 of this manual for the mechanical part maintenance methods.
故障处理前先阅读安全措施,如果更换装置中器件,则必须切断所有电源及与外界
的电气联接,以保证人身及设备的安全,严禁带电更换其它元件。
9-10
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
Read carefully the safety measures before troubleshooting. If it is needed to replace the
pieces from the device, cut off all powers and the external electrical connection so as to ensure
personnel and equipment safety, and it is prohibited to replace other live elements.
被更换器件最好由本公司提供,我公司提供的所有备件都已在工厂检测,可以直接
替换原被换件,不必进行跳线及设置等。
It is preferable to use the elements of our company for replacement. All the spare parts as
provided by our company had been detected before coming out of factory and it can directly
replace the original parts without any need to use jumper or other setting, etc.
在大部分情况下,调速系统的各正常功能都由调速故障监测系统在持续地监测着,
这些功能一旦发生故障,监测系统会发出报警信号,并给出故障信息。相应的故障处理
参见下面的调速系统故障及异常信息表中描述的方法进行。
Under most conditions, each normal function of the speed governing system is
continuously monitored by the monitoring system of the speed governing fault. Once such
functions fail, the monitoring system will send alarming signal and provide fault information.
Refer to the speed governing system faults as well as the methods as described in the
abnormal information sheet for the corresponding fault elimination measures.
调速器故障分为一般故障和严重故障,一般故障时“一般故障”指示灯点亮,“调速器
一般故障”信号报至 LCU;严重故障发生时,“严重事故”指示灯点亮,“调速器事故”信
号报至 LCU。
The speed governor fault is divided into common fault and serious fault. Once common
fault occurs, the Common Fault indicator lamp lights up and the Speed Governor Common
Fault signal is sent to LCU; once serious fault occurs, the Serious Accident indicator lamp
lights up and the Speed Governor Accident signal is sent to LCU.
◆ 一般故障 水头故障、功率给定故障、功率反馈故障、网频故障、残压测频故障、
齿盘测频故障,发生故障时“一般故障”指示灯亮,“一般故障”继电器动作,人机界
9-11
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
面显示对应的上述故障信息,调速器的主用状态不发生改变;
◆ The common fault includes water head fault, power setting fault, power feedback fault,
grid frequency fault, residual voltage frequency detection fault, and gear frequency
detection fault; once these faults occur, the Common Fault indicator lamp lights up and
the Common Fault relay acts, and the corresponding fault information is shown in the
human-machine interface, whilst the main function state of the speed governor will not be
changed;
◆ 严重故障 测频总故障(残压测频和齿盘测频同时发生故障)、导叶反馈故障、主配
压阀反馈故障、微机控制器故障、液压系统故障,事故指示灯亮,事故继电器动作,
人机界面显示对应的上述故障信息。调速器严重故障将自动进行主备用机切换 (若
两套控制器同时发生事故则控制的主用状态不变,同时调速器切到手动状态运行)。
◆ The serious fault includes total fault of frequency detection (both the residual voltage
frequency detection and gear frequency detection fail at the same time), guide vane
feedback fault, main distributing valve feedback fault, microcomputer controller fault,
hydraulic system fault. Once these faults occur, the accident indicator lamp lights up and
the accident relay acts, and the corresponding fault information is shown in the
human-machine interface. Once the serious fault of the speed governor occurs, the main
machine and standby machine will automatically switch (if two sets of controllers fail
then the main function state of the controller will not change and meanwhile the speed
governor switches into manual operation mode).
9-12
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
注意:严重故障检查均应该在停机状态下检查,如需要操作导叶来检查故障原因的必须
确认机组安全措施已经就绪,不会对检查人员和设备带来伤害。
state, and the indicator 4. 1 2 3 措施均无效,更换 CPU 模块。Replace CPU module if the
lamps of the rest IO measure 1, 2 and 3 are ineffective.
module are in flash state
or totally not light up
模块配置与实际信号
不 符 故 障 —— 功 能 模
块上的 RUN 指示灯亮,
同时 ERR 指示灯亮 1.检查连接到模块的信号是否超过了模块通道的容量;Check
Module configuration whether the signal as connected to the module exceeds the capacity
not in accord with actual of the module channel;
signal: RUN indicator 2.实际模块型号与软件中配置的型号不符 Actual module model
lamp on the functional is not in accord with the model as configured in the software.
module lights up and
meanwhile ERR
indicator lamp lights up
测 频 跳 变 大 —— 调 速
器无测频故障,测得的
机频与实际值比较差 1.以标准的频率信号装置,重新校验测频准确性,如校验过程
值大于 0.05Hz,且有震 中测频准确则检查 PT 回路的信号源;Use standard frequency
荡的迹象 signal device to re-verify the accuracy of the detected frequency, if
Large frequency the detected frequency is correct, check the signal source of PT
detection hopping: circuit;
speed governor is free 2.测频校验过程中发现测频仍不准确,首先更换测频用隔离变
of frequency detection 压器,重新校验后无效再更换测频整形版;If the detected
fault, the difference frequency is still not correct, replace the isolation transformer for
between the detected frequency detection purposes, and replace the frequency detection
unit frequency and the shaping panel if it is invalid after re-calibration;
actual value is larger
than 0.05Hz, and
oscillation occurs
1.检查是否存在驱动器或者电机本体温度超过 55℃的情况;
Check whether the drive or motor body exceeds 55℃;
2.检查电液转换器件有无锈蚀,损坏造成的操作卡涩的情况;
电 机 故 障 —— 人 机 界
Check whether the electro-hydraulic switching element is rusted,
面上报“电机故障” and whether the damage causes operation jamming;
Motor fault: motor fault
3.检查电机驱动器的供电电源是否在工作电压 220V/24V±10%
reported on the
human-machine 以内;Check whether the power for the motor drive is within the
interface working voltage 220V/24V±10%;
4. 按 照 驱 动 器 液 晶 面 板 上 的 故 障 代 码 表 确 定 故 障 原 因 ;
Determine the fault causes based on the fault code on the drive
LCD panel;
导叶/桨叶接力器抽动 1. 桨叶出现抽动时,切导叶机手动,观察桨叶是否正常,假如
—— 调 速 器 处 于 自 动 还出现抽动请按 3、4、5、6 条处理,如已为正常,桨叶抽
运行状态时,导叶/桨叶 动原因是跟随导叶协联,桨叶系统为正常,仅需排查导叶系
接力器频繁抽动,造成 统 。 Once the paddle twitches, switch the paddle into
机组负荷波动大或者 mechanical manual mode to view whether the paddle is normal,
机频波动大 if twitching lasts, please dispose it in accordance with clause 3,
9-17
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
9-18
调速器维护及故障处理 Speed Governor Maintenance and Troubleshooting
9-19
第十章
Chapter 10
调速器通讯
Governor Communication
10-1
调速器通讯 Governor Communication
10-2
调速器通讯 Governor Communication
Communication
MGC3000 系列调速器通过以太网的方式与其它设备之间实现连接和数
据交换,一般调速器在整个通讯网络中均作为从站,根据主站下发的读写代码要
求向主站的做出回应。
MGC3000 series governor establishes connection and data exchange with other
devices through Ethernet. In general, the governor is deemed as the slave station in
the overall communication network and makes response according to the
requirements of read/write code issued from master station.
Controller
To monitoring
system bus
Touch screen
图 10.1.1 通讯连接
A/B 机通过以太网交换机的网线直接通讯,其特点:
Controller A/ B makes direct communication through the cable of Ethernet exchanger.
It possesses features as following:
通讯速度快 普通的串口等通讯一般可达 15.2kbps,以太网轻松达到
10Mbps。
10-3
调速器通讯 Governor Communication
Fast communication: the communication for common serial port is 15.2 kbps,
and Ethernet communication is up to 10Mbps.
调试方便 调试实验只需要网线做为编程电缆,可直接连接两套控制器。
Convenient debugging: the debugging test requires the networks cables as
programming cable only, which can be connected with two controllers directly.
连接灵活 控制器 CPU 多余出的串口可与其它非以太网设备通讯。
Flexible connection: the excessive serial port of controller CPU can
communicate with other non-Ethernet devices.
控制器与人机界面通讯通过以太网交换机的网线直接通讯,其特点:
Controller and human-machine interface makes direct communication through
the network cable of Ethernet exchanger. It possesses features as following:
通讯速度快 普通的串口等通讯一般可达 15.2kbps,以太网轻松达到
10Mbps。
Fast communication: the communication for common serial port is 15.2 kbps,
and Ethernet communication is up to 10Mbps.
连接方便 普通的串口等需要 A/B 机都提供一个串口连接,不但占 CPU
串口,还占用人机界面自身的两个串口。
Convenient connection: the common serial port requires a serial connector for
Controller A/B individually, which not only occupies the CPU serial port but also
uses the two serial ports equipped on the human-machine interface.
维护方便 更换线路只需要网线。
Convenient maintenance: it only requires replacing network cables for circuit
replacement.
可靠性能 串口通讯线路易受干扰,维护时焊接头易脱落,网线没这方
面缺点。
Strong reliability: the communication of serial port is easy for disturbance, and
10-4
调速器通讯 Governor Communication
the welded connection is easy to fall off in maintenance. However, the network
cable does not have defects of this respect.
检查通讯链路的物理连接有无故障,尤其是接头有无误接、松脱;
Make sure the physical connection of communication link is fault free, especially
the connection does not have error or become loose;
检查端口的通讯参数设置是否正确,包括地址(站号)、通讯速率、数据位、
停止位;
Make sure the communication parameter settings are correct, including address
(station number), communication rate, data bit and stop bit;
检查设备是否被错误重启,且没有完全完成重启之后又被断电重启;
Make sure the device has not been restarted by mistakes and the device is not
powered off and restarted if it does not complete restart absolutely;
10-5
调速器通讯 Governor Communication
10-6
调速器通讯 Governor Communication
调速器通讯点表
模拟量
Analog Value
地址 变量名 当量对应关系
Address Variable Name Equivalent Correspondence
10-7
调速器通讯 Governor Communication
10-8
调速器通讯 Governor Communication
开关量
Switch Quantity
地址 变量名 地址 变量名
Address Variable Name Address Variable Name
Proportional valve of
%MW340:bit3 Shutdown process %MW343:bit3
guide vane failed
Proportional valve of
%MW340:bit4 Shutdown delay %MW343:bit4
paddle failed
10-9
调速器通讯 Governor Communication
%MW340:bit12 备用 %MW343:bit12
Quick generation
%MW340:bit15 %MW343:bit15
instruction
10-10
调速器通讯 Governor Communication
Primary frequency
%MW341:bit9 %MW344:bit9 Grid frequency failed
modulation action
10-11
调速器通讯 Governor Communication
10-12
第十一章
Chapter 11
硬件手册-控制器
Hardware Manual -
Controller
11-1
硬件手册-控制器 Hardware Manual - Controller
11-2
硬件手册-控制器 Hardware Manual - Controller
11.1. 概述 General
本章介绍我公司使用的微机控制器硬件特点与接线原理。
This chapter introduces hardware features and connection principles of
micro-controller used by our company.
我公司 MGC4000 系列调速器微机控制器主要采用施耐德 PLC M340 与贝加莱
PCC2005,这两款是在调速器中应用广泛、成熟、高效能的微机控制器。
Our micro-controller for MGC4000 series speed governors mainly employs
Schneider PLC M340 and BampR PCC2005, both of which are the mature and
high-performance micro-computer controllers that have widely applied in the
governors.
M340、PCC2005 都有各自优势,根据电站机组具体参数结合实际投运经验,计
算出每款控制器的配置参数,以下为两款控制器在调速器应用中模块经典配置。
Both M340 and PCC2005 have their respective advantages. Based on the specific
parameters of units in the power station and combining the actual operation
experiences, the configuration parameters for each controller are calculated. The
followings are the classic module configurations of two controllers for the governor
application.
※注意:本章用于产品硬件介绍,不应理解为具体项目产品的实际性能,不应理解为产品的具体模
块数。因此,不同项目产品之间会存在一些差异,应当以实际产品为准。
※Note: This chapter is for introducing the product hardware, neither for the actual performance of
specific project products nor for specific number of product modules. Therefore, there will be some
differences between different project products and in this case the actual products shall prevail.
11-3
硬件手册-控制器 Hardware Manual - Controller
24V or 48V
network
Alarm relay
Protective
grounding
11-4
硬件手册-控制器 Hardware Manual - Controller
端子号 端子名
Terminal Terminal
No. Name
1 RXD
2 TXD
3 RTS
4 D1
5 D0
6 CTS
7 5VDC
8 GND
RJ45 以太网引脚分配如下:
Pin assignment for RJ45 Ethernet is shown as following:
11-5
硬件手册-控制器 Hardware Manual - Controller
端子号 端子名
Terminal Terminal
No. Name
1 TD+
2 TD-
3 RD+
未连接
4 Not
connected
未连接
5 Not
connected
6 RD-
未连接
7 Not
connected
未连接
8 Not
connected
下图显示直流输入的电路图(正逻辑):
The following is the DC input circuit (positive logic):
Fuse Sensor power and voltage monitoring
Sensor
Input % I (O..n)
Entry
Module
图 12.4-1 直流输入电路图
Figure 12.4-1 DC Input Circuit Diagram
模块与传感器之间的连接显示如下:
Connection between the module and sensor is as following:
11-7
硬件手册-控制器 Hardware Manual - Controller
Fuse
电源 Power: +24VDC
熔断器 Fuse: 0.5A quick-break fuse 速断熔断器
图 12.4-2 模块与传感器之间的连接图
Figure 12.4-2 Connection Diagram between Module and Sensor
注:数字量输入信号的具体定义详见电气图纸。
Note: detailed definition of digital input signal refers to electrical drawing.
图 11.4-4 端子连接原理表
Figure 11.4-4 Terminal Connection Diagram
11-8
硬件手册-控制器 Hardware Manual - Controller
terminal block. It is a positive logic (or drain) module: 16-way output channel provides
current to pre-actuator.
下图显示直流输出的电路图(正逻辑):
The following is the DC output circuit (positive logic):
Output
Command
Error
图 12.5-1 直流输出电路图
Figure 12.5-1 DC Output Circuit Diagram
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Pre-actuator
Fuse
11-9
硬件手册-控制器 Hardware Manual - Controller
电源 Power: +24VDC
熔断器 Fuse: 0.5A quick-break fuse 速断熔断器
图 12.5-2 模块与预执行器之间的连接
Figure 12.5-2 Connection Diagram between Module and Pre-actuator
注:数字量输出信号的具体定义详见电气图纸。
Note: detailed definition of digital output signal refers to electrical drawing.
11-10
硬件手册-控制器 Hardware Manual - Controller
11-11
硬件手册-控制器 Hardware Manual - Controller
11-12
硬件手册-控制器 Hardware Manual - Controller
1:IN_A 输入
1: IN_A input
2:IN_B 输入
2: IN_B input
3:IN_SYNC 输入
3: IN_SYNC input
4:IN_A 输入
4: IN_A input
图 11.9-1 端子连接传感器图
Figure 11.9-1 Connection Diagram between Terminal and Sensor
下图显示电源和执行器到 10 针连接器的连接:
The connection between power/actuator and 10-pin connector is shown as following:
11-13
硬件手册-控制器 Hardware Manual - Controller
图 11.9-2 连接输出和输出电源图
Figure 11.9-2 Connection Diagram between Output and Output Power Supply
11-14