Product Application Matrix
Agilon Amplon
Hestia - 0.6 Kva RT Series N Series N Series R Series
SX- 0,6 kVA GAIA Series
VX- 0,6 kVA 5-10 kVA 1-3 kVA (online) 6, 12 kVA 1-3 kVA (online)
(off -line) 1-3 kVA (online)
(line interactive) (online) *120Vac (online) *120Vac

Configuration 1:1 X X X X X X X
Configuration 3:1

Configuration 3:3

Rack mountable X X X
Stand alone X X X X X X
Isolation Transformer X
Backup ’ S S S,L S,L S,L S S,L
Home and office * X X X X
Small enterprise, IT and medical ** X X X X X
Medium enterprice, telecom, IT,
media *** X X
Heavy i ndustry, telecom, IT, defence,
industry and building automation ****

’ Small back up time is 5~30mins.----- Long back up time is 0.5~24hrs


* PCs, laptops, modems, printers, hifi and audio equipment
** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation
*** telecom base stations, , data centers, backbone networks, broadcasting, projection systems
**** telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial equipment, automation and control
Delta Confidential
Product Application Matrix
Ultron Modulon
H Series NT Series DPS Series NH Series NH Plus Series DPH Series
15-30kVA 20-500kVA 160-200kVA 20-80kVA 20-120kVA 25-200kVA
(online) [4MVA] (online) [1600kVA] (online) (online) *208Vac (online)*208Vac (online)
Configuration 1:1

Configuration 3:1 X X

Configuration 3:3 X X X X X X

Rack mountable

Stand alone X X X X X X

Isolation Transformer X

Backup ’ S,L S,L S,L S,L S,L S,L

Home and office *

Small enterprise, IT and medical **

Medium enterprice, telecom, IT, media *** X X X X X


Heavy i ndustry, telecom, IT, defence,
X X X X X X
industry and building automation ****
’ Small back up time is 5~30mins.----- Long back up time is 0.5~24hrs
* PCs, laptops, modems, printers, hifi and audio equipment
** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation
*** telecom base stations, , data centers, backbone networks, broadcasting, projection systems
**** telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial equipment, automation and control

Delta Confidential
Delta UPS Product Overview
Delta UPS fall in four categories according to power level:

– : PC & Peripherals – : Data Center, Facility & Industrial


• Hestia 600 VA (1-phase, line-interactive) • H Series 15-30 kVA (3-phase, on-line)
• VX 600 VA (1-phase, line-interactive) • NT Series 20-500 kVA (3-phase, on-line)
• SX 600VA (1-phase, off-line) • DPS Series 160-200kVA (3-phase, on-line)

– : Server & Networking – : Modular


• GAIA Series 1-3 kVA (1-phase, on-line) • NH Series 20-80 kVA (3-phase, on-line)
• N Series 1-3 kVA (1-phase, on-line) • NH Plus Series 20-120 kVA (3-phase, on-line)
• N Series 6-12 kVA (1-phase, on-line) • DPH Series 25-200 kVA (3-phase, on-line)
• R Series 1-3 kVA (1-phase, on-line)
• RT Series 5-10 kVA (1-phase, on-line)

Delta Confidential
Delta UPS
- 600 VA UPS

Hestia 600 VA (1-phase, line-interactive)


VX 600 VA (1-phase, line-interactive)
SX 600 VA (1-phase, off-line)

Delta Confidential
SX Series 600VA
• Off-Line UPS.
• Wide Input voltage range (90 ~ 145)
• Backup Time 10-15 min.
• Wave Form (Battery mode): simulated sine.
• Output receptacles.

Applications
– PC
– Fax
– Monitor
– ADSL

Delta Confidential
Delta UPS
- Up to 12 kVA on-line UPS

GAIA Series 1-3 kVA (on-line)


N Series 1-3 kVA (on-line)
N Series 6-12 kVA (on-line)
R Series 1-3kVA (on-line)
RT Series 5-10kVA [22kVA] (on-line)

Delta Confidential
GAIA Series 1-3kVA
• Standard 19 inches rack / tower configuration(2U).
• Reduced battery discharge probability – extended
battery lifetime.
• RS232 and USB connectivity with Vista
compatible power management software.
• Built-in data line surge protector for phone / fax /
network.
• Output receptacles programmable for efficient
Applications
energy usage.
• Smart slot for mission critical applications. – Server Rack
• Extended battery cabinet available. – ATM
– Security
– Audio/Video
Delta Confidential
GAIA Series 1-3kVA Specification
1 kVA / 0.8kW 2 kVA / 1.6 kW 3 kVA / 2.1kW

Model GA1000R GA2000R GA3000R

Voltage 200 / 208 / 220 / 230 / 240Vac, single phase

Input Voltage Range 160 ~ 275 (full load)130 ~ 160 (linearly de-rating between 70% ~ 100% loading)

Input Connection Power cord

Output Receptacle IEC320 C13 x 3 x2 IEC320 C13 x 3 x 2; IEC320 C19 x 1

Internal Battery 12V/9Ah x 2 12V/9Ah x 4 12V/9Ah x 6

> 12 minutes (half load) > 14 minutes (half load) > 15 minutes (half load)
Backup Time
> 4 minutes (full load) > 5 minutes (full load) > 5 minutes (full load)

EBC* Model GA1000RB GA2000RB GA3000RB

EBC Rating 9Ah x 2 x 2 9Ah x 4 x 2 9Ah x 6 x 2

Interface RS232 x 1, USB x 1, SNMP slot x 1

Data Line Surge Protector Built-in (RJ11/RJ45, 1-to-1)

Tower Stand Kit Included

Rack Rail Kit Optional

Extended Battery Cabinet Optional. The connection cable to UPS is attached. Connector is non-standard type.

WxDxH (mm), same for UPS and EBC 440x335x89 440x432x89 440x610x89

UPS Weight (kg) 13 21 31

Battery Cabinet (kg) 16 29 43

Delta Confidential
N Series 1-3kVA

• Reduced battery discharge probability –


extended battery lifetime.
• Compact size. Savings in the installation space.
• Smart slot for mission critical applications.
• RS232 connectivity compatible power
management software.
• Extended battery cabinet available. Applications
– PC, Workstation
– POS
– ATM
– Security
Delta Confidential
N Series 1-3kVA Specification
*Version 120Vac
1 kVA / 0.7kW 2 kVA / 1.4 kW 3 kVA / 2.1kW
Model GES102N200035 GES202N200035 GES302N200035
Voltage 200 / 208 / 220 / 230 / 240Vac, single phase
Input Voltage Range 80~280Vac. Lower range 80~176Vac is acceptable under 50~100% loading condition.
Input Connection Power cord
Output Receptacle IEC320 C13 x 4 IEC320 C13 x 8
Internal Battery 12V/7Ah x 3 12V/7Ah x 6 12V/9Ah x 6
Backup Time > 14 minutes (half load) > 5 minutes (full load)
EBC* Rating 12V/7Ah x 6 12V/9Ah x 6
Interface RS232x1 RS232x1, SNMP slot x 1
Data Line Surge Protector Optional (RJ11/RJ45, 1-to-1)
Extended Battery Cabinet Optional. Connection is by Delta standard battery cable.
UPS WxDxH (mm) 140x366x242 140x425x373
EBC WxDxH (mm) 140x366x242 (Same as 1KVA)
UPS Weight (kg) 14 30.5
EBC Weight (kg) 20

Delta Confidential
N Series 6,12kVA
• Reduced battery discharge probability – extended
battery lifetime.
• High input power factor(pf>0.98), savings in
installation costs.
• Built-in isolation transformer and dual output voltage.
• Built-in manual bypass switch for maintenance.
• Remote emergency power off function.
• Extended battery cabinet available.
Applications
– IT Room
– Medium Office
– Banking
Delta Confidential
N Series 6,12kVA Specification
6 kVA / 4.2kW 12 kVA / 8.4kW
Model GES602N500135 GES123N500135
Voltage 120/220Vac , single phase
Input Voltage Range 120~280Vac. Lower range 120~176Vac is acceptable under 70~100% loading condition.
Input/Output Connection Hard wire (Terminal block)
Internal Battery 12V/7Ah x 20 12V/7Ah x 20
EBC* Rating 12V/7Ah or 9Ah, maximum 60pcs
Battery Charging 0.7A 1.3A
Optional Charger Board Max. 7A (external installation)
Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1, Dry contatx1

Maintenance Bypass Switch Built-in

UPS WxDxH (mm) 280x581x784


EBC WxDxH (mm) 280x581x784
UPS Weight (kg) 133 165

Delta Confidential
R Series 1-3kVA
• Standard 19 inches rack / tower configuration(2U).
• Reduced battery discharge probability – extended
battery lifetime.
• Smart slot for mission critical applications.
• USB and RS232 connectivity compatible power
management software.
• Extended battery cabinet available.
• EPO. Applications
• High input power factor (pf > 0.97). – Server Rack
• Power Factor (output) 0,8 @1kva, 2kva. – ATM
– Security
– Long Backup
Delta Confidential
Time
R Series 1-3kVA Specification
*Version 120Vac
1 kVA / 0.7kW 2 kVA / 1.4 kW 3 kVA / 2.1kW

Model GES102R202035 GES202R202035 GES302R202035

Voltage 230Vac , single phase

Input Voltage Range 80~280Vac. Lower range 80~176Vac is acceptable under 50~100% loading condition.

Input Connection Power cord

Output Receptacle IEC C13x4 IEC C13x8 ; IEC C19x1

Battery Source Rating 36Vdc 72Vdc

Battery Charging Max. 5A Max. 4.5A

Optional Charger Board* Max. 5A Max. 4.5A

Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1

Tower Stand Kit Optional

Rack Rail Kit Included


Data Line Surge Protector Optional

EBC** Optional. Connection is by Delta standard battery cable.

WxDxH (mm) 440x450x89

Weight (kg) 6.7 9.2

Delta Confidential
RT Series 5-10kVA
• Standard 19 inches rack / tower configuration.
• High output power factor 0.9
• 1+1 parallel redundancy to increase the reliability and
flexibility.
• High input power factor (pf > 0.99) and low harmonic
distortion (iTHD < 5%).
• High recharging capability: built-in 4Amp and optional
4Amp extra charger.
• Two smart slots for mission critical applications.
• Multi-language LCD display and status LED. Applications
• Optional maintenance bypass box for parallel – IT Room
redundancy with manual bypass switch. – Security
• Extended battery cabinet available. – Banking
• Extended charger box available. – Long Backup
Time
Delta Confidential
RT Series 5-10kVA Specification
5 kVA / 4.5kW 6 kVA / 5.4 kW 10 kVA / 9kW
Model RT5K RT6K RT10K
Voltage 200/208/220/230/240Vac , single phase
Input Voltage Range 100~300Vac
Input/Output Connection Hard wire (Terminal block)
EBC* Rating 12V/5Ah x 16 12V/9Ah or 12V/34W x 20
Battery Charging Max. 4A
Optional Charger Board** Max. 4A
Internal Battery None! Customer can connect to their own battery source based on correct rating.
Interface RS232x1, SNMP slotx1, Smart slotx1
Rack Rail Kit Optional (But tower stand kit is included)
Parallel Redundancy 1+1
Maintenance Bypass Box Optional
UPS WxDxH (mm) 440x671x89 440x623x131
EBC WxDxH (mm) 440x638x89 440x595x131
UPS Weight (kg) 15.5 21.3
EBC Weight (kg) 37 66
Delta Confidential
Delta Single Phase UPS

• True on-line double conversion technology.


• Wide input voltage range.
• High input power factor and low iTHD.
• Compact dimension.
• Smart cards available for customize capability.
• Delta’s powerful monitoring software for easy
UPS remote management. Applications
• Available for long backup application. – Offices
– Networking
– Medical
– Banking
– Security
Delta Confidential
Delta UPS
- Up to 4000 kVA online UPS

H Series 15-30 kVA (on-line)


NT Series 20-500 kVA [4MVA](on-line)
DPS Series 160-200kVA [1600kVA](on-line)

Delta Confidential
H Series 15-30kVA

• Reduced battery discharge probability – extended


battery lifetime.
• High input power factor, savings in installation costs.
• Hot-standby installation is feasible to increase the
reliability.
• Built-in manual bypass switch for maintenance.
• Extended battery cabinet available.
• Local and remote emergency power off function.
Applications
– Small Data Center
– Banking
– IT Room
Delta Confidential
H Series 15-30kVA Specification
*Version 208/120Vac (20kva y 30kva)
15 kVA / 12kW 20 kVA / 16 kW 30 kVA / 24 kW
Model GES153H GES203H GES303H
Voltage 220/380 , 230/400 , 240/415 (3phase, 4-wire plus ground)
Input Voltage Range 156 ~ 280 / 270 ~ 485 Vac
Input/Output Connection Hard wire (Terminal block)
3/3 model : 220/380 , 230/400 , 240/415 (3phase) 220/380 , 230/400 , 240/415
Output Voltage
3/1 model : 220/230/240 (single phase) (3phase)

Battery Source Rating 240Vdc


Battery Charging 2.6A 5.2A
Optional Charger Board Max. 5A (external installation)
Internal Battery None
Interface RS232x1, SNMP slotx1, AS400x1, Dry contactx1
Maintenance Bypass Switch Built-in
EBC* Optional (Two type : 26Ah or 40Ah) Connection is by Delta standard battery cable.
WxDxH (mm) 380x650x860 (UPS and EBC are the same)
UPS Weight (kg) 108
EBC Weight (kg) 26Ah: 270kg ; 40Ah: 370kg
Delta Confidential
NT Series 20-500kVA
• N+X parallel reduncancy (up to 8 cabinets) for reliability
and flexibility, w/o extra hardware.
• Economic mode for energy and operation cost savings.
• Built-in manual bypass switch for maintenance.
• Built-in SRAM, recording maximum 500 real-time event
logs.
• Compatible with gnerator installation.
• 6 configurable UPS status dry contact outputs.
• Optional 12-pulse rectifier or filter for lower harmonic
distortion.
• Possibility for shared battery source enabling cost
Applications
– Networking
savings. – Data centers
• Custom order voltage rating. –

Telecommunications


Medical
Extended battery cabinet available. – Banking
– Industrial
Delta Confidential
NT Series Specification
NT-series general specification
120 / 208, 220 / 380, 230 / 400, 240 / 415, 277 / 480Vac,
Voltage
three phase, 4 wire plus ground
Voltage Range ±20 %

Interface RS232 x 1, RS485 x 1, SNMP slot x 1, Status output x 6

Parallel Redundancy Maximum 8 units

Input Harmonic Improvement Optional 12-Pulse rectifier or filter


SRAM Event Log Maximum 500 records
Battery Start Yes

100 120 160 200


20 kVA 30 kVA 40 kVA 50 kVA 60 kVA 80 kVA 260 kVA 320 kVA 400 kVA 500 kVA
kVA kVA kVA kVA

1.9 x
W x D x H (m) 0.6 x 0.8 x 1.4 0.8 x 0.83 x 1.7 1.2 x 0.83 x 1.7 1.6 x 0.995 x 1.95 0.995 x
1.95

Weight (kg) 365 365 425 460 506 525 700 745 1050 1085 1680 1720 1920 2400

* Above table is based on 220/380Vac rating.


** 500KVA model is assembled by two cabinets: Inverter (width=1100mm, 1700kg) and Rectifier (width=800mm, 700kg).
Delta Confidential
DPS Series 160 – 200kVA
• Rating: 160/200kVA, double conversion 3phase UPS
• 0.9 high output power factor delivers more real power
• IGBT-based rectifier and transformer-less architecture
• Novel 3 Phase PFC Topology (3 Phase 4 Switch)
• Three-Level Inverter Topology
• Energy efficiency up to 95% (on-line mode)
• Fully digital control guarantees higher reliability
• Wide Input voltage range (-40% ~ 20%)
• Parallel link up to 8 units
• Mimic LCD display with multi-language selection Applications

• Front access for easy maintenance




Networking
Data centers
• Compact design – Telecommunications
– Medical
Delta Confidential – Banking
DPS Series 160 – 200kVA Specification

Delta Confidential
Delta UPS
- Up to 800 kVA online UPS

NH Series 20-80 kVA [320kva] (on-line) // *208Vac 40-60kVA


NH Plus Series 20-120 kVA [480kva](on-line) // *208Vac 40-120kVA
DPH Series 25-200 kVA [800kva](on-line).

Delta Confidential
NH Series 20-80kVA
• N+X parallel reduncancy (up to 4 cabinets, total max. =320kVA)
for reliability and flexibility, w/o extra hardware.
• High input power factor (pf > 0.99) and low harmonic distortion
(iTHD < 3%).
• Over 94 % high efficiency.
• Modular design for easy maintenance.
• Built-in manual and static bypass switch for maintenance.
• Built-in SRAM, recording maximum 500 real-time event logs.
• Multi-language LCD display and status LED indicators.
• Compatible with gnerator installation.
• 6 configurable UPS status dry contact outputs.
• Optional kit for monitoring battery cabinet temperature. Applications
– Networking
• Customized voltage rating. – Data centers
– Telecommunications
– Medical
– Banking
Delta Confidential – Industrial
NH Series Specification
*Version 208/120Vac (40kva y 60kva)
20 kVA / 16 kW 40kVA / 32kW 60kVA / 48kW 80kVA / 64kW
Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
208~477 / 120~276 (380/220 rating).
Input Voltage Range
Lower range 208~300 / 120~173Vac is acceptable under 70~100% loading condition.
Input Power Factor > 0.99
Input Current Harmonic
< 3% (full load)
Distortion
380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Output Voltage
Other rating is available in another cabinet (I/P and O/P transformer is included)
Connection Hard wire (Terminal block)
RS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2, Parallel port x 1,
Interface
Battery cabinet temperature x 4
Parallel Link Up to 4 cabinets. Total maximum = 320kVA
Extended Battery
Optional
Cabinet
WxDxH (mm) 520 x 850 x 1165
Weight (kg) 125 175 210 244
Delta Confidential
NH Plus Series 20-120kVA
• Hot-swappable function to provide uninterruptible power during
module replacement.
• N+X parallel reduncancy(up to 4 cabinets, total max. =480kVA)
for reliability and flexibility, w/o extra hardware.
• High input power factor (pf > 0.99) and low harmonic distortion
(iTHD < 3%).
• Over 94 % high efficiency.
• Built-in manual and static bypass switch for maintenance.
• Built-in SRAM, recording maximum 500 real-time event logs.
• Multi-language LCD display and status LED indicators.
• Compatible with gnerator installation. Applications
• 6 configurable UPS status dry contact outputs. – Networking
• Optional kit for monitoring battery cabinet temperature. – Data centers
– Telecommunications
– Medical
– Banking
Delta Confidential – Industrial
NH Plus Series Specification
*Version 208/120Vac (40kva - 120kva)
20kVA / 16kW 40kVA / 32kW 60kVA / 48kW 80kVA / 64kW 100kVA/80kW 120kVA/96kW
Voltage 380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
208~477 / 120~276 (380/220 rating).
Input Voltage Range
Lower range 208~300 / 120~173Vac is acceptable under 70~100% loading condition.

Input Power Factor > 0.99

Input Current
< 3% (full load)
Harmonic Distortion
380/220 , 400/230 , 415/240 (3Phase, 4-wire plus ground)
Output Voltage
Other rating is available in another cabinet (I/P and O/P transformer is included)
Connection Hard wire (Terminal block)
RS232 x 1, Smart Slot x 2, Dry contact output x 6, Contact input x 2, Parallel port x 1,
Interface
Battery cabinet temperature x 4
Parallel Link Up to 4 cabinets, total maximum = 480kVA
Extended Battery
Optional
Cabinet
WxDxH (mm) 520 x 910 x 1165 520 x 975 x 1695
Weight (kg) 170 200 230 260 320 350

Delta Confidential
DPH Series 25-200kVA

Desempenho
e eficiência de
Disponibilidade Escalabilidade alimentação

Delta Confidential
Apresentação do produto
Modulon DPH é um UPS modular ideal para Data Centers de pequeno e médio porte,
além de outras aplicações de TI.
Desempenho e
Disponibilidade Escalabilidade eficiência de
alimentação

Disponibilidade para Fácil Ampliação para Alto Desempenho e


manter a continuidade atender a rápida eficiência, para reduzir
das operações críticas expansão dos negócios. os custos operacionais.

1.Tolerância a falhas: 1.Eficiência AC-AC:


Redundância para 1.Expansão vertical: 96% a plena carga; 95% em
componentes chaves Escalável a quente em um rack 30% de carga
de até 8 unidades
2.Tecnologia Hot-Swap: 2.Fator de alimentação
Manutenção fácil para reduzir o 2.Expansão horizontal: unitário:
MTTR Expansão paralela de até 4 kVA=kW
unidades. (F.P.saída = 1)

2.Baixo THDi < 3%

37
Delta Confidential
Arquitetura exterior
Dimensões Vista frontal com porta aberta Vista de trás com porta aberta
Módulo de
controle
Módulo STS

Disjuntor de saída Disjuntor


Disjuntor de bypass de bypass
Disjuntor de entrada manual
mm principal
2000

Módulo de
alimentação

Mesma dimensão do rack padrão de 19” Portas de trás dividida para


38 economia de espaço
Delta Confidential
Delta Three Phase UPS

• True on-line double conversion technology.


• Wide input range.
• High efficiency.
• High input power factor and low iTHD.
• Delta’s powerful monitoring software for easy UPS remote
management.
• Multi-Language user-friendly graphic LCD display and LED
indicators.
Applications
• Parallel redundancy installation for reliability enhancement.
– Networking
• Parallel expansion for flexibility and initial investment savings.
– Data Center
• Modular design for easy commissioning.
– Telecommunication
– Medical
– Banking
– Industry
Delta Confidential
Delta Power Management Software
UPSentry Smart 2000
InsightPower Manager
InsightPower Client
Shutdown Agent

Delta Confidential
Delta Power Management Software

Delta Confidential
Management software
Line condition monitoring
• Real-time UPS status

Delta Confidential
Management software
Display Dashboard
• Real-time monitoring.
• Multiple views formats: Meters and gauges

Delta Confidential
Management software
Real-time notification

• SMS (Short Message)


• Pager
• SNMP trap
• E-mail
• Network broadcast
• Audible alarm
• External command file
• Receptacle control

Delta Confidential
Management software
Scheduling task

• Shutdown/Restart
• Quick test, deep battery test
• Outlet bank control

Delta Confidential
Management software
UPSentry Smart 2000

Delta Confidential
Management software
InsightPower Manager

Delta Confidential
Management software
InsightPower Client

Delta Confidential
Management software
Shutdown Agent

Delta Confidential
UPS Connectivity SNMP Card

Delta Confidential
UPS Connectivity SNMP IPv6 Card

Delta Confidential
UPS Connectivity Relay I/O Card

Delta Confidential
UPS Connectivity Modbus Card

Delta Confidential
UPS Connectivity Mini-SNMP Card

Delta Confidential
UPS Connectivity Mini-USB Card

Delta Confidential
UPS Connectivity Mini-Dry Contact Card

Delta Confidential
UPS Connectivity Mini-TVSS Card

Delta Confidential
UPS Connectivity EnviroProbe

Delta Confidential
Summary
Power range from 0.6-500 kVA
Delta UPS fall in four categories:
– -
– -
Both single and three phase configurations
On-line and line-interactive series
Wide range of applications
– PC & Peripherals
– Sever & Networking
– Data Center, Facility & Industrial
– Modular
Delta UPS provide
– Full range of uninterruptible power protection.
– High efficiency for operation cost savings.
– High reliability and performance.
– ISO14001, RoHS compliance.
Delta Confidential – World wide service.