Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or Split Type Air Conditioners
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
FTNE-M Series
shock, fire or explosion. Cooling Only [50 Hz]
Read the user’s manual carefully before using this product. The user’s manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of September 2015 but subject to change without notice. c All rights reserved PC
Personalise Your Cool Daikin’s sophisticated airflow control and low sound pressure levels surround
you with a cloud of quiet comfort. Choosing the right model is easy, with a full
lineup of 6 models from 1.5 to 6.0 kW available. These stylish, compact units
FTNE-M
series using
look just as cool as they feel. R-410A is
newly
launched.
1 2
Comfortable Airflow Control
When you choose the low angle, cool air slides off to
reach the corners of the room.
3 4
Energy Savings and Quiet Operation
Capacity (W)
3.15 Set temp. before
Off timer begins
Cooling
COP = to operate
Power consumption (W) FTNE35M
+ 0.5 C
3.15
FTNE25M Time
60 minutes
3.20 Off timer turns on Off timer stops air conditioner
3.30
FTNE15M
3.75
20 28 30 40 50 50 FTNE50/60M
(dB (A))
Indoor Unit On/Off Switch
5 6
Worry-Free Design Functions Function List
Comfortable Airflow
Dual Flaps
salt corrosion. A hydrophilic film layer also prevents rust
Auto Fan Speed
caused by the run off of water droplets. Wide-Angle Louvers Wide-Angle Louvers
The microprocessor automatically controls fan speed to
The smoothly curved Wide-Angle Louvers provide wide adjust the room temperature to the set temperature.
airflow coverage for effective operation no matter where the
Vertical Auto-Swing
indoor unit is placed in a room. (up and down)
Cross section of anticorrosion-treated fin See page 4
Hydrophilic film
Timers
Aluminium Vertical Auto-Swing (up and down)
Comfort Control
This function automatically moves the flaps up and down to Programme
Corrosion-resistant Count Up-Down On/Off Timer Dry Function
acrylic resin distribute air across a room.
See page 4 This timer function allows an off time (up to 9 hours later)
and on time (up to 12 hours later) to be set simply by Auto Fan Speed
pressing the Timer On/Off button on the remote controller.
Convenience
the On/Off timer button on the wireless remote controller.
Lifestyle
Power Chill Operation boosts airflow to maximum volume New Powerful
for a 20-minute period. After this, the unit automatically The On timer and Off timer can be used in combination. Operation
returns to its previous settings.
See page 3 Night Set Mode Indoor Unit
Long Piping Length for Flexible Pressing the Off timer button automatically selects Night
On/Off Switch
Unit Placement New Powerful Operation Set Mode. This function prevents excessive cooling for a
Cleanliness
New Powerful Operation boosts airflow to maximum pleasant sleep. After 60 minutes, the room temperature is
The FTNE35/50/60M supports a piping length of up to 20 raised by 0.5˚C. Wipe-Clean
volume for a 20-minute period. After this, the unit Flat Panel
See page 6
metres to give flexibility during unit installation. This allows automatically returns to its previous settings.
See page 3
the outdoor unit to be placed on a balcony or where it can not
be seen. Indoor units can also be installed where they do not
Indoor Unit On/Off Switch Worry Free Count Up-Down
On/Off Timer
compromise the decor of a room. The unit can be conveniently started manually in the event
the wireless remote controller is misplaced or the wireless
Timers
remote controller batteries are not charged. Auto-Restart after Power Failure 24 Hour
On/Off Timer
Max. piping length Max. level difference See page 6 The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to them
FTNE15/20/25M 15 m 12 m when power is restored after a power failure. Night Set Mode
Cleanliness
FTNE35/50/60M 20 m 15 m
Self-Diagnosis with Digital Display
Wipe-Clean Flat Panel Malfunction codes are shown on the digital display panel Auto-Restart after
The flat panel design can be cleaned with only the single of the wireless remote controller for fast and easy
Worry Free
Power Failure
pass of a cloth across its smooth surface. The flat panel can maintenance.
also be easily removed for more thorough cleaning. Self-Diagnosis with
Digital Display
Anti-Corrosion Treatment of Outdoor Heat
FTNE60M Exchanger Fins
Max. piping length The outdoor unit’s heat exchanger fins are processed using
Max. level difference
Worry Free
Anti-Corrosion Treatment
of Outdoor Heat
Exchanger Fins
7 8
Controllers Specifications
Wireless Remote Controller for FTNE15/20/25/35M Indoor unit FTNE15MV1 FTNE20MV1 FTNE25MV1 FTNE35MV1 FTNE50MV1 FTNE60MV1
Model name
Outdoor unit RNE15MV1 RNE20MV1 RNE25MV1 RNE35MV1 RNE50MV1 RNE60MV1
kW 1.46 2.09 2.62 3.35 5.20 6.40
Capacity
Btu/h 5,000 7,000 9,000 11,450 17,750 21,800
Power supply 1 phase, 220 V, 50 Hz
Running current A 1.9 3.0 3.6 5.0 8.0 9.3
Power consumption W 390 633 819 1,063 1,650 2,032
COP W/W 3.75 3.30 3.20 3.15 3.15
Indoor unit FTNE15MV1 FTNE20MV1 FTNE25MV1 FTNE35MV1 FTNE50MV1 FTNE60MV1
Front panel colour Almond white White
Airflow rate H m3/min (cfm) 7.2 (254) 8.1 (286) 18.5 (653)
Fan speed 5 steps and automatic
Power Chill Operation Sound pressure level H/L dB (A) 35/28 37/28 39/33 48/35 48/36
On/Off switch Dimensions HxWxD mm 273 x 784 x 195 290 x 1,050 x 238
Selects mode: Sets room temperature
Machine weight kg 8 12
cooling, dry, fan-only operation Outdoor unit RNE15MV1 RNE20MV1 RNE25MV1 RNE35MV1 RNE50MV1 RNE60MV1
Casing colour Ivory white
Selects fan speed Type Hermetically sealed rotary type
Compressor
Motor output W 350 593 760 900 1,300 1,959
Vertical Auto-Swing Refrigerant
Type R-410A
Cancels On/Off Timer (up and down) Charge kg 0.42 0.65 0.67 0.88 0.90
Sound pressure level dB (A) 49 50 51 54 53
Count Up-Down Off Timer Count Up-Down On Timer Dimensions HxWxD mm 418 x 695 x 244 550 x 658 x 275 595 x 845 x 300
and Night Set Mode Machine weight kg 21 24 25 32 36 40
Operation range CDB 19.4 to 46
Liquid 6.4
Piping connection Gas mm 9.5 12.7 15.9
Drain 18.0
Max. piping length 15 20
m
Max. level difference 12 15
Measurement conditions
Note: The holder for the wireless remote controller is not available. 1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 5 m.
2. Sound pressure levels are measured in an anechoic chamber based on condition 1. above. These values are normally somewhat higher during actual operation as a result of ambient conditions.
Outdoor unit
Cancels On/Off Timer No. Item RNE15/20/25/35/50/60M
1 Drain plug *1 KKP937A4
24-Hour On Timer Note: *1. One set includes five pieces for five units.
9 10