Huawei Data Center Product Catalogue
Huawei Data Center Product Catalogue
Catalogue
Huawei Energy Powering the Future Digital Maintenance and Intelligent Operation
3 Huawei Smart Cooling Solutions
4 Huawei Management system
04
05
Contents
Modular Data Center ���������������������������������������������������������������� 08
Prefabricated Data Center �������������������������������������������������������� 22
FusionModule2000&5000
FusionModule800
FusionModule500
FusionModule500
06
Outdoor Prefabricated Data Center
FusionModule1000B
FusionModule1000A
07
Modular Data Center
FusionModule5000 Smart Modular Data Center
Introduction
HUAWEI FusionModule5000 is a new generation smart modular data
center solution with complete integration of cabinets, power supply and
distribution systems, cooling systems, cabling systems, management
software, and other subsystems. It supports flexible deployment with
single or dual row, cold or hot aisle containment.
Application Scenarios
• Maximum IT power per module can be up to 310kW, which meet FusionModule5000 (Dual-row)
the requirements of large-scale data center for industries like ISP,
government, education, healthcare, finance, telecom, etc.
• Designed for chilled water cooling scenarios.
Efficient
• Closely coupled cooling to efficiently avoid partial hot spot, high-
density deployment supportive
• Hot/cold aisle containment for isolation of hot and cold air
• Local/remote monitoring, PAD or cell phone mobile O&M
Simple
• Standardized devices, modular architecture, on-demand deployment
• Busway for power distribution is optional , easy installation
08
Specifications
Item Specifications
Single-row with aisle containment (L×W×H (IT cabinets)):
L×2400×2000mm, L≤15 m
L×2300×2000mm, L≤15 m
L×2400×2200mm, L≤15 m
Dimensions
Dual-row with aisle containment (L×W×H (IT cabinets)):
L×3600×2000mm, L≤15 m
L×3400×2000mm, L≤15 m
L×3600×2200mm, L≤15 m
Cabinet number per
System Single row: 2-24; Dual row: 6-48
module
Power supply 380/400/415Vac, 50/60Hz, 3Ph+N+PE
IT power consumption per PDU inside: 310kW
module New Main Way inside: 396kW
Redundancy N+1/2N
Availability Tier II or Tier III (up to Tier IV)
Altitude 0-4000m (derating above 1000m)
Installation Installed on concrete or base support
2000mm×600/800mm×1200mm
Dimensions (H×W×D) 2000mm×600/800mm×1100mm
Cabinet 2200mm×600/800mm×1200mm
Space available 42U/47U
Protection level IP20
Cooling capacity 30/65 kW
2000mm×300mm×1200mm/
In-row chilled
Dimensions (H×W×D) 2000mm×600mm× 1200mm/
water smart
2200mm×600mm× 1200mm
cooling product
Power supply 200-240V (1Ph, 50/60Hz)
Refrigerant Water/Ethylene Glycol
Rated Voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Input MCCB Capacity 400/250A
Output MCB 16,40,63A/1P x6 routes or 16,40A/3P x2 routes
New Main Way Surge protection level-C SPD. In=20kA
Monitoring the voltage, current, power, power factor, temperature for
Monitoring function
key point, harmonic etc.
Communication Modbus
Input voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Precision power
Rated capacity 400/250/160A
distribution
AC SPD 20kA, 8/20μs
cabinet (UPS
outside) 16A/20A/32A/40A optional, max branches up to 144 (single phase), or 48
Output
(three phase)
09
Modular Data Center
FusionModule2000 Smart Modular Data Center
Introduction
FusionModule2000 is a new generation of smart modular data center
product which had been awarded the World’s First "Uptime Tier IV
Ready" Certification. It is a module that comprises power, cooling,
rack & structure, cabling, and management. The structure of the
module can be single-row or dual-row, and supports both cold or hot
aisle containment. In addition, Huawei integrates AI technology into
the data center which significantly improves the reliability, availability,
and efficiency of the data center through iPower, iCooling, and
iManager. Dual row, Contained cold/hot aisle
Application Scenarios
•• Designed mostly for small-to-medium sized data centers
•• Suitable for enterprise HQ or large regional branch, operator,
bank secondary branch, government, education, healthcare, etc.
*: Optional Configuration
10
Specifications
Item Specifications
Single row (with aisle containment) (L×W×H):
L×2400×2410mm
L×2300×2410mm
L×2400×2610mm
Dimension
Dual row (with aisle containment) (L×W×H):
L×3600×2410mm
L×3400×2410mm
L×3600×2610mm
Cabinets per module Single row≤24 cabinets; dual row: ≤48 cabinets
Micro Module
Power supply 380/400/415Vac, 50/60Hz, 3Ph+N+PE
125kW (with integrated UPS)/ 145kW (with integrated PDC)/ 198kW (with
Max IT load per module
New main way)/ 235kW (with precision PDC)
Ultra low temperature condition: -40ºC to 45ºC(Need low-temp kit)
Operation condition T1 condition: -20ºC to 45ºC
T3 condition: -5ºC to 55ºC(Need T3 outdoor unit)
Cable routing Routed in/out through the top of cabinets
Installation Installing on concrete floor or raised floor
2000mm×600/800mm×1200mm
Dimensions (H×W×D) 2000mm×600mm×1100mm
Cabinet 2200mm×600/800mm×1200mm
Space available 42U/47U
Protection level IP20
Cooling capacity 25kW/46kW
2000mm×300mm×1100mm
Air-cooled In-row Dimensions (H×W×D)
2000mm×600mm×1200mm
air conditioner
Power supply 380V AC~415V AC 50/60Hz, 3Ph+N+PE
Refrigerant R410A
Input voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Input 250/400A MCCB (single input); 250A/400A ATS (dual input)
Input power factor Full load > 0.99, Half load > 0.98
Integrated UPS Output power factor 1.0
(UPS inside) Rated capacity 25~125kVA
Output IT: 40A/1P×24×2; A/C: 40A or 63A/3P×8; lighting: 10A/1P×3
Efficiency ≥ 96%
AC SPD 5kA, 8/20μs
Input voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Integrated power Input IT: 160/250A MCCB; A/C: 160/250A MCCB (single/dual input)
distribution cabinet Rated input current IT: 160A/250A, Air conditioner: 160A/250A
(UPS outside) Output IT: 40A/1P×24×2; A/C: 40A or 63A/3P×8; lighting: 10A/1P×3
AC SPD 20kA, 8/20μs
11
Recommended Configurations——UPS Inside
Single-row Dual-row
IT IT IT IT IT IT IT IT IT IT IT IT IT
Air
Air
Air
R8-32kW R24-112kW
(aisle) (aisle)
Integrated
Integrated
Battery
Battery
Battery
Air
IT IT IT IT IT IT IT IT
Air
Air
Air
IT IT IT IT IT IT IT IT IT IT IT
Air
R8 single row module typical layout R24 dual row module typical layout
IT Load
Power Supply Redundancy AC Configuration Battery
(kW)
20 25kW×2
40 25kW×3
100 46kW×4
125 46kW×5
12
Recommended Configurations——UPS Outside Installation Outside
Single-row Dual-row
Air conditioner
Air conditioner
Air conditioner
IT IT IT IT IT IT IT IT IT IT IT IT
R8-32kW R24-140kW
(aisle) (aisle)
Air conditioner
Air conditioner
Integrated PDC
Integrated PDC
Air conditioner
Air conditioner
Air conditioner
IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT IT
R8 single row module typical layout R24 dual row module typical layout
IT Load
IT Power Supply AC Power Supply Redundancy AC Configuration
(kW)
20 25kW×2
40 25kW×3
145
46kW×5
160
Power Distribution
200 Precision PDC 46kW×6
Box
235 46kW×7
13
Modular Data Center
FusionModule800 Smart Small Data Center
can be deployed flexibly on both sides. A single module can support PDU
Glass door
maximum12 racks and 25kW IT load (T3: IT Load≤21kW), the maximum
UPS Touch
power density for each rack is 7kW/ R(T3:≤6kW). Cold and hot aisle Transformer
screen
(optional))
containment to saving Energy and reduce noise. Monitoring module
Aisle
Efficient
• Rack-mounted air conditioner saves at least one rack footprint.
600 to 7400mm
• Cold and hot aisle containment, saving energy and reducing noise.
• Improve the efficiency of cooling system through DC variable
frequency compressor, wet film humidification ,cold and hot aisle Hot aisle
ATS
containment. PDU
1100mm
Reliable
250mm
14
Specifications
System features Centralized management for multiple DCs
Power system 380/400/415Vac, 50Hz, 3Ph+N+PE
Aisle containment Cold and hot aisle containment
System protection level IP20
T1*:-20℃~+45℃;
Ambient temperature T3*:-10℃~+55℃;
LT*:-40℃~+45℃;
Maximum cabinet quantity
12 LTE
for a module
Quantity of IT cabinets 0~10
25kW (T1* & LT*)
Maximum IT load
21kW (T3*) TCP/IP
7kW (T1* & LT*)
Max power density /Rack
6kW (T3*)
Mobile operation
IT cabinet weight Static load 1500kg, Dynamic load 1000kg
Total Dimensions
2000×(600-7400)×1350 Module1
(H×W×D mm) Management for
Cooling system single module ……
Power system 220/230/240Vac, 50Hz, 1Ph+N+PE
Cooling capacity 12.5kWa APP (local) Module 2 Module N
Operating temperature of T1*:-20℃~+45℃;
T3*:-10℃~+55℃;
the outdoor unit LT*:-40℃~+45℃;
Configuration N, N+1 WiFi
ECC800 data acquisition
Cooling mode Direct expansion air-cooled
Installation Rack- mounted
Air volume 2600m³/h
Air supply mode Front supply, rear return Battery UPS Cooling Temperature Water Door status Video
Power Supply and Distribution System and humidity sensor sensor
SPD CLASSII/C, In 20kA, Imax 40kA, 8/20us
Input power Single or dual inputs 7 Basic Configurations for T1/T3/LT
UPS capacity 10kVA 20kVA ≤8.5KW(T1/LT) 8.5KW~17kW(T1/LT)
UPS configuration N, N+1 IT load
≤7KW(T3) 7KW~14kW(T3)
UPS output power factor 0.9
Basic configuration BC1* BC2 BC3* BC4*
UPS rated input voltage 380/400/415Vac, 50/60HZ, 3Ph+N+PE
UPS input voltage range 138~485Vac, 40~70Hz, 3Ph+N+PE Aisle type Single row, cold & hot aisle containment
220/230/240Vac 380/400/415Vac UPS(KVA) 10+0 10+10 20+0 20+20
UPS rated output voltage
50/60Hz, 1Ph+N+PE 50/60Hz, 3Ph+N+PE
Smart cooling 1+0 1+1 2+0 2+0
UPS efficiency 94.5% 95%
Power input Single input is default (ATS optional)
Battery backup mode Battery pack, battery cabinet, battery rack
Backup time 15min/30min IT output 4 12 12 12
No-Intelligent rPDU: IEC or GB,on site Intelligent Power
NO NO NO NO
rPDU (Optional) installation distribution
Intelligent rPDU:IEC,on site installation
ATS (Optional) On site installation 17~25KW(T1/LT) ≤8.5KW(T1/LT) 8.5~17kW(T1/LT)
Maintenance bypass Standard IT load
14kW~21kW(T3) ≤7KW(T3) 7~14kW(T3)
Intelligent battery
Optional
monitoring system Basic configuration BC5* BC6* BC7*
Monitoring system
Aisle type Single row, cold&hot sealed
Mobile phone APP, SMS alarm, Web access,
Monitoring system
centralized management for multi-DCs UPS(KVA) 20*2+0 10+10 20+20
10 inched Pad Standard Smart cooling 3+0 1+1 2+0
Water sensor Optional
Power input Single input is default (ATS optional)
Camera Optional
Smoke sensor Standard IT output 20 12 12
Intelligent door lock Standard Intelligent Power
NO Yes Yes
Facial recognition Standard distribution
Temperature and humidity
Standard
sensor Note:
Local app on the mobile phone,SMS alarm 1, Basic configuration 1, 3,4,5,7 are only applicable to TierI DC.
2, The cooling capacity 12.5kW is obtained when the indoor dry bulb temperature is
Mobile O&M NetEco remote app on the mobile 37.8℃, and outdoor dry bulb temperature is 35℃,relative humidity 20%.
phone(optional) 3, ATS is optional and can be installed on site
4, T1:-20℃~ +45℃,LT:-40℃~ +45℃;T3:-10℃~ +55℃
5, BC1 cooling without heating and humidification, the others are all have one
cooling with heating and humidification
6, BC6 & BC7 are intelligient power distribution.
7, The Converged cabinet part number don't include cooling out door unit.three
type of outdoor unites are freely configured with the converged cabinet.
15
Smart Mini Data Center Solution
FusionModule500
Introduction
一体化架构 Integrated architecture
FusionModule500 smart mini data center solution integrate UPS, PDU,
monitoring, battery pack in a cabinet. All parts are prefabricated, pre- Monitoring
监控模块
installed, pre-tested. On-site installation is simple to achieve rapid
deployment. The remote monitoring function with web interface can
PDU
realize remote operation. At the same PDU
time, FusionModule500 can be
equipped with Huawei NetEco management system, achieving centralized
UPS UPS
monitoring and unified management.
Efficient
•• Rack DC, saving at least 50% space
Integrated cabinet
Reliable
•• Civil smart cooling product intelligent start, no risk of overheat
•• Battery overheating intelligent shutdown to prevent the fire
Application scenarios
•• Bank sites, education, enterprise branches, retail merchandising and
carrier business halls, etc.
Integrated cabinet+network cabinet
•• No need special data center room
or Integrated cabinet+battery cabinet
Netco management
Display screen
system
Integrated cabinet+network
Site 1 Site 2 Site n cabinet+battery cabinet
16
Specifications
17
Prefabricated Data Center
FusionModule1000A Prefabricated All-in-One Data Center
Introduction
Huawei FusionModule1000A is an advanced outdoor and prefabricated
all-in-one data center facility solution. The solution provides reliable, stable
and green environment for IT equipment. The solution can be applied to
multiple industries and scenarios and meet data center’s requirements on
energy saving and fast deployment.
Efficient
• High-efficiency modular UPS, smart in-row cooling, aisle containment,
enclosure of low heat transfer coefficient, industry-leading PUE
• Huawei NetEco system centralize the management of multiple sites. 3D
visualized managment, power&cooling monitoring enable smart O&M
• Efficient O&M anywhere& anytime with PAD and mobile APP
18
Layout
Layout
Integrated UPS Integrated UPS
Battery Battery
Cooling indoor units Cabinet Cooling indoor units Cabinet
Cooling Cooling
outdoor units Fire gas cylinder outdoor units Fire gas cylinder
FusionModule1000A-40ft-IT-2N FusionModule1000A-40ft-IT-N+X
Plan View
FusionModule1000A-40ft-IT-2N
FusionModule1000A-40ft-IT-N+X
19
Managment System
Local Display
20
Specifications
FusionModule1000A FusionModule1000A FusionModule1000A FusionModule1000A
System Sub-item System Sub-item
40ft-IT-N+X-380V ⑦ 40ft-IT-2N-380V ⑦ 40ft-IT-N+X-380V ⑦ 40ft-IT-2N-380V ⑦
21
Prefabricated Data Center
FusionModule1000A Prefabricated All-in-One Data Center
Introduction
Huawei FusionModule1000A is an advanced outdoor and prefabricated
all-in-one data center facility solution. The solution provides reliable, stable
and green environment for IT equipment. The solution can be applied to
multiple industries and scenarios and meet data center’s requirements on
energy saving and fast deployment.
Efficient
• High-efficiency modular UPS, smart in-row cooling, aisle containment,
enclosure of low heat transfer coefficient, industry-leading PUE
• Huawei NetEco system centralize the management of multiple sites.
• Efficient O&M anywhere& anytime with PAD and mobile APP
Reliable
• Durable enclosure with 25-year servive life
• IP55 protection (IP65 optional) and GR-63-CORE Zone3 anti-seismic
120min fire-resistance when covered with customized fire-proof panel,EN
1627~EN 1630 Class 3 anti-theft(optional)
FusionModule1000A Site
22
Layout
FusionModule1000A-40ft-IT-2N
Layout
Plan View
23
Managment System
Local Display
24
Specifications
FusionModule1000A FusionModule1000A
System Sub-item System Sub-item
40ft-IT-2N-208V⑦ 40ft-IT-2N-208V⑦
Compressor DC variable-frequency
Cooling
Group control Support
25
Prefabricated Data Center
FusionModule1000B Prefabricated Modular Data Center
Overview
FusionModule1000B is a modular designed, prefabricated data
center. It comprises enclosure structure, power supply, cooling,
firefighting, lighting,and management systems. As an outdoor solution,
FusionModule1000B has outstanding environment adaptability and anti-
disaster ability. It is ideal solution to replace brick and mortar data center.
Application Scenarios
Prefabricated Modular Data Center
ICT Room Colo&Hosting
Regular Building-like
Appearance Appearance
Efficient
•• 2-year earlier ROI than that of traditional DC
•• PUE drop from 1.65 to 1.51 with iCooling(Middle East)
•• O&M efficiency increased from150 to 210 racks/person with
iManager
Reliable
•• Maximum 40-year long service life
FusionModule1000B Chilled-water solution
•• Mercalli scale-9 earthquake-proof and 120min fire-resistance
•• High protection level: IP55, IP65 (optional)
26
Specifications
System Specification
Huawei Huawei
Huawei NetCol5000A
NetCol5000C NetCol8000C
Cooling mode In-row air-cooled PAC
In-row chilled- In-room chilled-
Cooling
water PAC water PAC
Temperature -40ºC-+52ºC*
Working
Relative humidity 10%-100%
Environment
Altitude ≦ 3000m
Protection
Water&dust proof IP55( optional IP65)
IT scenario 2N or N+X
*Under condition of +45ºC ~ +52ºC, the high temperature air conditioner is required. Under condition of -40ºC ~ -15ºC,the low temperature air
conditioner is required. Application in above mentioned high-temperature and low temperature environment will cause change to specifications 27
some parameters will change.
2 Modular Design, Beyond Reliability
Huawei UPS Solutions
28
29
Contents
UPS2000-A Series (1-3kVA)������������������������������������������������� 32
UPS2000-A Series (6-10kVA)���������������������������������������������� 34
UPS2000-G Series (1-3kVA)������������������������������������������������ 36
UPS2000-G Series (6-20kVA)���������������������������������������������� 38
UPS5000-E Series (25-75kVA Battery Integrated) ...............40
UPS5000-E Series (25-125kVA)������������������������������������������� 42
UPS5000-E Series (50-800kVA)������������������������������������������� 44
UPS5000-E Series (60-600kVA,60kVA Power Module) �������� 46
UPS5000-S Series (50-800kVA)������������������������������������������� 48
UPS5000-A Series (30-120kVA)������������������������������������������ 50
UPS5000-A Series (200-800kVA)���������������������������������������� 52
UPS Li-ion Battery Solution������������������������������������������������ 54
FusionPower Series (UPS5000-S-1200kVA-FP) �������������������� 58
Modular Precision Power Distribution Cabinet PDU8000����� 60
iBattery Intelligent Management Solution�������������������������� 62
UPS2000-G Series
(1-20kVA)
UPS2000-A Series
(1-10kVA)
30
UPS5000-S Series
(50-800kVA)
UPS5000-E Series
(25-800kVA)
31
UPS2000-A Series
(1-3kVA)
Introduction
UPS2000-A series with a capacity ranging from 1kVA to 3kVA is an online
double conversion power system that delivers continuous, high-quality
AC Power. It’s really a perfect power protection solution for small power
scenarios.
Scenarios
•• Small and medium enterprises, large enterprise branch offices, bank
branches and other small data centers
•• Networks, communications systems, automatic control systems and UPS2000-A-1K/2K/3K
other precision equipment
•• Family, office
Features
Reliable
•• Wide input voltage range to minimize battery use
•• Online double conversion power system provides continuous, high-
quality AC Power
Efficient
•• Efficiency up to 90%, reduce energy consumption, green and energy-
saving
•• Ultra small volume, compared to the traditional UPS system to save
space
Simple
•• LCD screen supports real-time monitoring and convenient operation
•• Built-in battery, easy to use
•• Enables quick and easy configuration of the UPS
•• NetEco network manager, supporting centralized management to all
the UPSs
32
Specifications
Output Connections 4 X IEC C13 6 X IEC C13 6 X IEC C13 + 1 X IEC C19
Output Frequency Tracking the bypass input (Normal mode); 50/60Hz ± 0.05%
Output
Output Power Factor 0.8
Overload Capacity ≤110% overload for 10 minutes; ≤130% overload for 1 minute;≤150% overload for 3 seconds
Standard 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318
D x W x H (mm)
Long Backup 282 x 145 x 220 397 x 145 x 220 397 x 145 x 220
Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc.
33
UPS2000-A Series
(6-10kVA)
Introduction
UPS2000-A series (6-10kVA) is a tower-mounted, online double
conversion power system that delivers continuous, high-quality AC
Power. up to 96% efficiency at online mode for 6/10kVA models helps
save 50% energy cost. It’s really a perfect power protection solution for
small power scenarios.
Scenarios
•• Small and medium enterprises, large enterprise branch offices, bank
branches and other small data centers
•• Networks, communications systems, automatic control systems and UPS2000-A-6K/10K
other precision equipment
•• Family, office
Features
Reliable
•• Wide input voltage range to minimize battery use
•• Key component failure pre-alarm including fans, batteries to remind
customers to maintain before failure occurs
•• Coating design & key device pin special protection enhance reliability
Efficient
•• High efficiency of up to 96% at online mode for 6/10kVA reduces
power loss of UPS and smart cooling product and saves customers
more than 50% over less efficient models
•• The output power factor is 0.9, high load capacity
Simple
•• LCD screen supports real-time monitoring and convenient operation
•• Built-in battery design provides you integrated solution and makes it
especially applicable for space-scarce use
•• 6kVA/10kVA Professional Edition supports 4 machines in parallel
operation, built in maintenance bypass, easy to use
•• The NetEco 1000U management system monitors UPSs in real time
and allows users easy management, and operation
•• Multiple remote monitoring: supports SMS, E-mail, etc
•• NetEco network manager, supporting centralized management to all
the UPSs
34
Specifications
6kVA/5.4kW 10kVA/9kW
Rated capacity (kVA/kW)
(Standard Version) (Standard Version)
35
UPS2000-G Series
(1-3kVA)
Introduction
UPS2000-G series with a capacity ranging from 1kVA to 3kVA is an online
double conversion power system that delivers continuous, high-quality
AC Power. It’s really a perfect power protection solution for small power
scenarios. It’s support tower and rack installation.
Scenarios
UPS2000-G-1K/2K/3K
•• Small and medium-sized enterprises, large enterprise branch offices,
bank branches and other small data centers
•• Networks, communications systems, automatic control systems and
other precision equipment
Features
Reliable
•• Wide input voltage range to minimize battery use
•• Online double conversion power system provides continuous, high-
quality AC Power
Efficient
•• Efficiency up to 90%, reduce energy consumption, green and energy-
saving
•• Ultra small volume, compared to the traditional UPS system to save
space
Simple
•• LCD screen supports real-time monitoring and convenient operation
•• Built-in battery, easy to use
•• Enables quick and easy configuration of the UPS
•• NetEco network manager, supporting centralized management to all
the UPSs
36
Specifications
Output Connections 4 X IEC C13 6 X IEC C13 6 X IEC C13 + 1 X IEC C19
Output Output Frequency Tracking the bypass input (Normal mode); 50/60Hz ± 0.05%
Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc.
37
UPS2000-G Series
(6-20kVA)
Introduction
UPS2000-G series with a capacity ranging from 6kVA to 20kVA is an online
double conversion power system that delivers continuous, high-quality
AC power. It is rack/tower convertible and 95% high efficiency helps it get
ECA energy saving certification from United Kingdom government and the
world’s first batch of "Energy Star" certification. It’s really a perfect power
protection solution for small power scenarios.
UPS2000-G-6K/10K
Scenarios
•• Small and medium-sized enterprises, large enterprise branch offices,
bank branches and other small data centers
•• Networks, communications systems, automatic control systems and
other precision equipment
Features
Reliable
•• 5kA lightning protection design, reducing lightning-related failure rate
•• Key component failure pre-alarm including fans, batteries, bus UPS2000-G-15K/20K
capacitors to remind customers to maintain before failure occurs
•• Ultra-wide voltage input range to extend battery service life by
effectively reducing times of switchover to battery mode
Efficient
•• High efficiency at online mode to reduce power loss of UPS and air
conditioner: up to 95% for 15/20kVA, 94.5% for 10kVA, 94% for 6kVA
Simple
•• Rack/tower convertible, suitable for different installation scenarios
•• High expandability design: up to four units can be connected in parallel
to achieve higher capacity or reliability
•• NetEco network manager, supporting centralized management to all
the UPSs
38
Specifications
Standard 240V DC -
Rated
Battery 384-480V DC, 32-40 section adjustable,
Voltage Long Backup 192-240V DC
default 40
Output Rated Frequency Tracking the bypass input (Normal mode); 50/60 Hz±0.05% (Battery mode)
39
UPS5000-E Series
(25-75kVA Battery Integrated)
Introduction
UPS5000-E Battery Integrated Solution features the double-conversion
online and modular design with pre-integrated battery module, fast on-site
deployment & installation, intelligent management, unattended operation
and simple O&M, thus providing customers with reliable, efficient and
Power Module: 25kVA/2U
simple modular UPSs.
Scenarios
•• Small-to-medium sized data centers
•• Telecom and Internet switch computer rooms of small-to-medium sized
enterprises
•• Area network and communication equipment rooms
•• Computer rooms of branch offices of industries like finance, etc
Features
Reliable
•• Wide input voltage range from 138Vac to 485Vac to suit for worst grid
and minimize battery use Integrated Cabinet
•• Dual-controller design to eliminate the single point of failure 25kVA-75kVA
•• Redundant auxiliary power supply and fans
•• Intelligent Battery Management: monitoring battery's temperature,
early warning for failure, battery powered high reliability.
Efficient
•• High efficiency of system up to 96%
•• Intelligent hibernation technology to keep UPS operating at high
efficiency
•• All in one design, saving the area of 50%
Simple
•• Modularized power, bypass, control and battery modules, fast
installation and maintenance
•• 7-inch colored LCD showing real-time operation status in various
languages
•• Various communication interfaces including dry contacts, RS485, Modular Battery Cabinet
Modbus etc.
•• NetEco network manager, supporting centralized management to all
the UPSs
40
Specifications
Model UPS5000-E-(25-75kVA)-BF
Total Harmonic
Input <3% (100% linear load)
Distortion
Output Frequency Tracking the bypass input (Normal mode); 50/60Hz±0.05% (Battery mode)
Overload Capacity ≤110% overload for 60min; ≤125% overload for 10min; ≤150% overload for 1min
Operation Temperature 0 to 40 ºC
Maximum Operation Altitude 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3
Noise <65dB
System Expandability 4
Integrated Cabinet Power Backup Standard configuration 2 to 4 groups of battery (8 to 16 battery modules)
Battery Cabinet (optional) Power Optional battery cabinet, 1 to 8 groups of battery (4 to 32 battery modules) per
Backup cabinet, max. 4 cabinets in parallels
Support battery or empty battery for battery module, battery typical configuration:
Others Battery Module
10×12V 9Ah
Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc.
Notice:
1. The UPS series are for commercial/industrial use and not used for life support equipment;
2. The critical systems concerning economic and public security must adopt power supply architecture that comply with Uptime TIERIII or TIER IV
requirements stated in TIA942.
41
UPS5000-E Series
(25-125kVA)
Introduction
Based on the online double conversion technology, UPS5000-E series
(25-125kVA) can provide reliable, pure and uninterrupted power for
critical ICT equipment. The modularized architecture helps improve the
availability and reduce the engineering cost significantly.
Scenarios
25kVA Power Module @ 2U
•• Small & medium data center, large enterprise regional datacenter
•• Central offices, dispatch center, control center, etc.
Features
Reliable
•• 138-485Vac ultra-wide input voltage range, suitable for the worst
power grid
•• Redundant design for modules, elimination of the single point of failure
•• iPower pre-warnings for key components in case of power supply
interruption
Efficient
•• High efficiency up to 96% at most frequently-used load rate, reducing
power consumption of UPS and cooling efficiency
•• Intelligent hibernation technology ensures efficient UPS operation
Simple
•• Hot swappable power module, bypass module and control module,
simple maintenance and expansion in 5 minutes
•• iPower real time monitoring system for UPS, PDU and batteries, UPS5000-E-125K-FM
elimination of manual routing inspection
42
Specifications
Model UPS5000-E-125K-FM
Rated Capacity (kVA/kW) 25kVA/kW 50kVA/kW 75kVA/kW 100kVA/kW 125kVA/kW
Number of Power Modules 1 2 3 4 5
Input Wiring 3Ph+N+PE
Total Harmonic
THDi<3% for linear load
Distortion
Battery Rated Voltage 360-528Vdc (The number of batteries can be selected from 30 to 44; 32 batteries in default)
Voltage 380/400/415Vac±1%
Frequency Tracking the bypass input (Normal mode); 50/60Hz±0.05% (Battery mode)
Overload Capacity Inverter: 110% overload for 60 minutes; 125% overload for 10 minutes; 150% overload for 1 minute
Efficiency Up to 96%
Expandability 4
Operating Altitude 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3
Height×Width×Depth
2000 × 600 × 850
(mm)
Communication
Dry contacts, RS485, FE; Support SNMP, Modbus.
Interface/Protocol
Notice:
1. The UPS series are for commercial/industrial use and not used for life support equipment;
2. The critical systems concerning economic and public security must adopt power supply architecture that comply with Uptime TIERIII or TIER IV
requirements stated in TIA942.
43
UPS5000-E Series
(50-800kVA)
Introduction
UPS5000-E Series (50-800kVA) is an advanced modular UPS based on
Huawei's extensive experience in digital technology and power electronics.
Benefiting from high performance DSP and high speed communication
technology, the UPS5000-E system achieves leading expandability and
availability. Its high efficiency, high availability match the requirements of
cloud data center perfectly.
Scenarios
UPS5000-E-200/300K
•• Data centers in headquarter or disaster recovery data centers
•• Internet data centers
•• Large cloud computing data centers
Features
Reliable
•• 138-485Vac ultra-wide input voltage range, suitable for the worst
power grid
•• Redundant design for modules, elimination of the single point of failure
•• iPower pre-warnings for key components in case of power supply
interruption
Efficient
•• High efficiency up to 95%-96% at most frequently-used load rate UPS5000-E-400/500K
•• Intelligent hibernation technology ensures efficient UPS operation
•• Single UPS capacity up to 800kVA, 50% footprint saving, more IT rack
space
Simple
•• Hot swappable power module, bypass module and control module,
simple maintenance and expansion in 5 minutes
•• iPower real time monitoring system for UPS, PDU and batteries,
elimination of manual routing inspection
44
Specifications
Introduction
UPS5000-E series (60-600kVA, 60kVA Power Module)-SMS/FMS is a high
performance modular UPS comprising of 3U 60kVA power modules. It
has leading performance in the industry and delivers reliability, efficiency,
simplicity and intelligence to the customer. These features meet the power
supply needs of large data centers in the cloud computing era.
Scenarios
•• Data centers in headquarter or disaster recovery data centers 400kVA/500kVA-SMS/FMS
•• Internet data centers
•• Large cloud computing datacenters
•• Large IT device and manufacture device
•• Public safety system and E-government system
Features
Reliable
•• 138-485Vac ultra-wide input voltage range, suitable for the worst
power grid
•• Redundant design for modules, elimination of the single point of failure
•• iPower pre-warnings for key components in case of power supply
interruption
Efficient 600kVA-SMS/FMS
•• High efficiency up to 96% at most frequently-used load rate
•• Intelligent hibernation technology ensures efficient UPS operation
•• Single power module capacity up to 60kVA/54kW. Single UPS capacity
up to 600kVA/540kW, 50% footprint saving, more IT rack space
Simple
•• Hot swappable power module, bypass module and control module,
simple maintenance and expansion in 5 minutes
•• iPower real time monitoring system for UPS, PDU and batteries,
elimination of manual routing inspection
46
Specifications
47
UPS5000-S Series
(50-800kVA)
Introduction
UPS5000-S Series (50-800kVA) is an advanced modular UPS based
on Huawei's extensive experience in digital technology and power
electronics. Benefiting from high performance DSP and high speed
communication technology, the UPS5000-S system achieves leading
expandability and availability. Its high efficiency, high availability
match the requirements of cloud data center perfectly.
UPS5000-S-200/300kVA UPS5000-S-400/500kVA
Scenarios
•• Data centers in headquarter or disaster recovery data centers
•• Internet data centers
•• Large cloud computing data centers
Features
UPS5000-S-600kVA UPS5000-S-800kVA
Reliable
•• 138-485Vac ultra-wide input voltage range, suitable for the worst
power grid
•• Redundant design for modules, elimination of the single point of
failure
•• iPower pre-warnings for key components in case of power supply
interruption
Efficient
•• High module efficiency up to 97.5% and system efficiency up to
96%-97% at most frequently-used load rate
•• Intelligent hibernation technology ensures efficient UPS operation
•• Single cabinet power capacity up to 600kVA, 50% footprint
saving, more IT rack space
Simple
•• Hot swappable power module, bypass module and control
module, simple maintenance and expansion in 5 minutes
•• iPower real time monitoring system for UPS, PDU and batteries,
elimination of manual routing inspection
48
Specifications
49
UPS5000-A Series
(30-120kVA)
Introduction
The UPS5000-A (30-120kVA) is an online, double-conversion, and tower/
rack convertible UPS that Huawei has launched. It uses the digital signal
processing (DSP) technology to output pure and stable sine wave with
a voltage of 380/400/415 Vac. With comprehensive reliability assurance
measures and other leading technologies, the UPS5000-A (30-120kVA)
can provide reliable, economical, intelligent, and convenient solutions to
medium power scenarios.
Scenarios UPS5000-A-30/40K
Features
Reliable
•• Wide input voltage range to minimize battery use: 485-305 Vac for
100% load; 305-138 Vac for 100%-40% load (derating linearly)
•• High output power factor of up to 1, 30% more load driven than
traditional UPS
Efficient
•• High efficiency at online mode of up to 95.7%, reducing power
consumption of UPS and cooling equipment effectively
Simple
UPS5000-A-60/80/120K
•• Rack/tower convertible, suitable for different installation scenarios
•• Flexible battery configuration: 30-44 batteries per string allow customers
to get the faulty battery out instead of replacing it
50
Specifications
Total Harmonic
THDi<3% for 100% linear load
Distortion
Battery Rated Voltage 360-528Vdc (The number of batteries can be selected from 30 to 44; 32 batteries in default)
Output Frequency Tracking the bypass input (Normal mode); 50/60Hz±0.05% (Battery mode)
Overload Capacity 110% overload for 60 minutes; 125% overload for 10 minutes; 150% overload for 1 minute
51
UPS5000-A Series
(200-800kVA)
Introduction
Huawei UPS5000-A (200-800kVA) is an online double conversion UPS
which can output pure sine wave with rated voltage of 380/400/415 Vac.
UPS5000-A has a high efficiency of up to 96% and high power density of
up to 300kVA per cabinet; all-digital control allows precise output at any
input and load condition. It’s suitable to ensure continuous power supply
to critical loads in large datacenters.
Scenarios
•• Large data centers, server rooms, security systems of finance, telecom
and other large enterprises UPS5000-A-200/300K
•• Data center of government or public institutions
•• Precision instruments
Features
Reliable
•• Wide input voltage range to minimize battery use: 485-305 V for 100%
load; 305-138 Vac for 100%-40% load (derating linearly)
•• Better load adaptability: high output power factor up to 1 and no
derating for capacitive or inductive devices with a PF>0.5
Efficient
•• High efficiency of up to 96%, reducing power consumption effectively
•• High power density of up to 300kVA per rack, 50% footprint saving
compared with traditional UPS
UPS5000-A-400/500K
Simple
•• Flexible battery configuration: 30-44 batteries per string allow customers
to get the faulty battery out instead of replacing it
52
Specifications
Total Harmonic
THDi<3% for 100% linear load
Distortion
Battery Rated Voltage 360-528Vdc (The number of batteries can be selected from 30 to 44; 40 batteries in default)
Output Frequency Tracking the bypass input (Normal mode); 50/60 Hz±0.05% (Battery mode)
Overload Capacity 110% overload for 60 minutes; 125% overload for 10 minutes; 150% overload for 1 minute
Communication
Dry contacts, RS485, FE; Support SNMP, Modbus.
Interface/Protocol
Notice:
1. The UPS series are for commercial/industrial use and not used for life support equipment;
2. The critical systems concerning economic and public security must adopt power supply architecture that comply with Uptime TIERIII or TIER IV
requirements stated in TIA942.
53
UPS Li-ion Battery Solution
SmartLi
Introduction
SmartLi is a battery energy storage system developed by Huawei for
UPS, which has the features of safety and reliability, long lifespan, space
saving and easy maintenance. LFP is the safest cell of Li-ion battery. The
unique active current balance control technology supports the mix use
of new and old batteries, which reduces Capex. Three-level BMS system
realizes intelligent battery management with Huawei UPS and Network
management system, which reduces Opex.
Scenarios
•• Long lifespan, cycle lifetime is 3000 times
•• LFP cell ensures safety and reliability SmartLi
•• Three-level BMS ensures reliability
•• Active current balance control, full use of battery
Specifications
Item 200kVA/200kW
Product Model SmartLi-512V-80AH
Protection Over temperature, over current, short circuit, over charge/discharge, etc.
54
Specifications
Item 800kVA/800kW
Storage Temperature 0ºC ~ 45ºC
Specifications
600kW - - - 13 17
55
FusionPower Series
(UPS5000-S-1200kVA-FP)
Introduction
UPS5000-S-1200kVA-FP which belongs to FusionPower series solution is
an advanced power supply solution integrate modular UPS, input PDU and
output PDU. The system adopts UPS5000-S which achieves high efficiency,
the module efficiency is up to 97.5% and system efficiency is up to 97%.
This integrated solution can save more space for customers and its high
efficiency, high availability match the requirements of data center perfectly.
Scenarios
•• Data centers in headquarter or disaster recovery data centers
•• Internet data centers Power Module: 55kVA/3U & 97.5%
•• Large cloud computing data centers
Features
Reliable
•• 138-485Vac ultra-wide input voltage range, suitable for the worst
power grid
•• Redundant design for modules, elimination of the single point of failure
•• iPower pre-warnings for key components in case of power supply
interruption
Efficient
•• High module efficiency is up to 97.5% and system efficiency is up to
96.5%-97% at most frequently-used load rate
UPS5000-S-1200kVA-FP
•• Integrated power solution saves 40% footprint
•• Installation labor hours reduced by 60%
Simple
•• Hot swappable power module, bypass module and control
module,simple maintenance and expansion in 5 minutes
•• iPower real time monitoring system for UPS, PDU and batteries,
elimination of manual routing inspection
56
Specifications
Model UPS5000-S-1200kVA-FP
Input Wiring 3Ph+N+PE
Total Harmonic
THDi<3% for 100% linear load
Distortion
Battery Rated Voltage 360-528Vdc (The number of batteries can be selected from 30 to 44; 40 batteries in default)
Output Frequency Tracking the bypass input (Normal mode); 50/60 Hz±0.05% (Battery mode)
Overload Capacity 110% overload for 60 minutes; 125% overload for 10 minutes; 150% overload for 1 minute
Operating Altitude 0-1000m. Above 1000m, derating rate based on EN/IEC 62040-3
Height×Width×Depth
2200*2800*1000
(mm)
Others Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc.
Communication
Dry contacts, RS485, FE; Support SNMP, Modbus.
Interface/Protocol
57
Modular Precision Power Distribution
Cabinet PDU8000
Introduction
The Precision Power Distribution Cabinet provides power distribution,
electrical parameters measurement and risk pre-alarm functions to match
the reliable operation of data center.
Scenarios
•• Large data centers
•• Disaster recovery data center
•• Enterprise date centers
Features
Reliable
•• A full range of type tests, environmental tests and 9 intensity seismic
tests to ensure high reliability
•• Intelligent risk management, 24 hours key node temperature real-time
detection
•• Modular design, standardized production, fully automated testing to
ensure product reliability
Simple
•• The monitoring module and the output switch can be hot-swappable,
which is easy to expand and maintain
•• 7 inch LCD color touch screen, visual intelligent detection, simple
management
58
Specifications
Total Harmonic
THDi<3% for 100% linear load
Distortion
Rated current of
10/16/20/32/40/63 (optional)
outputs(A)
Monitoring Function
Monitoring the voltage, current, power, power factor, harmonic etc. of the main circuit Monitoring the current,
Monitoring Function
load ratio, active power, switch status etc. of the branch circuit
Environment
Others
Dimensions (WxDxH)
600×1100×2000,600×1200×2000,600×1200×2200
(mm)
Installation Floor-mounted
59
iBattery Intelligent Management Solution
Product Introduction
iBattery is an intelligent battery management system based on wireless transmission. It can perform real-time detection of core
parameters including voltage, current, temperature and internal resistance. Besides, through the linkage with Huawei UPS system,
it can, by effectively identifying the SOH, provide automatic shutdown of battery group in an emergency so as to keep stable and
reliable operation of the backup power system.
Application Scenario
Operation with Huawei UPS or NetEco, applicable to:
•• 12V valve regulated lead acid battery
•• 2V valve regulated lead acid battery
60
iBox Technical Specifications
Type iBox
•• Support automatic identification of weak cells Northbound Communication Protocol SNMP, modbus TCP, modbus RTU
•• Linkage with UPS, automatic shutdown in case of
Dimensions (H*W*D) 180mm×116mm×43.6mm
emergent fault (fire)
Weight <0.45kg
Weight <0.1kg
61
3 Huawei Energy Powering the Future
Huawei Smart Cooling Solutions
62
63
Contents
NetCol5000-A In-row Air Cooled Smart Cooling Product��������������������66
NetCol5000-C030 In-row Chilled Water Smart Cooling Product����������68
NetCol5000-C065 & C080 In-row Chilled Water Smart Cooling Product��70
NetCol8000-A In-room Air Cooled Smart Cooling Product������������������72
NetCol8000-A050D & A100D In-row Air Cooled Smart Cooling Product
�����������������������������������������������������������������������������������������������������������74
NetCol8000-C In-room Chilled Water Smart Cooling Product�������������76
NetCol5000-A NetCol5000-C
(21-42kW) (30-80kW)
In-room Smart Cooling Product
NetCol8000-C
(62-253kW)
NetCol8000-A
(50/100kW)
NetCol8000-
A013U
A: Air cooled
C: Chilled water
In-row Air Cooled Cooling Product
NetCol5000-A
Introduction
NetCol5000-A is the in-row air cooled smart cooling product developed
by Huawei. It is configured with DC inverter compressor, EC fans, PTC
electric heater and electrode humidifier. Cooling capacity is 21kW, 25kW,
42kW. It is usually installed between the IT racks, closely coupled with heat
source so as to provide in-row cooling solution for medium-high density
data centers. NetCol5000-A supports piping and cabling from both top
and bottom side of the unit, and can be accessed from both front and
back side. It is an efficient, reliable and simple solution, helps to build next
generation green data center.
Application Scenarios
NetCol5000-A025 NetCol5000-A042
•• Modularized data center
•• Small and Medium sized Enterprise data center
•• Carrier base, city/district level data center
•• Financial branches
Reliable
•• Dehumidification at low load: reliable dehumidification at minimum
10% load, eliminate condensation risk
•• Expansion valve shut automatically: Expansion valve will shut
automatically after unexpected power cut, eliminate liquid return
which may hit compressor
•• Refrigerant detection: AI algorithm detects the refrigerant content,
generating charging prompt when the refrigerant is insufficient
66
Technical Specification
NetCol5000-A Technical Specification
Unit model Unit NetCol5000-A021H NetCol5000-A025H NetCol5000-A050H
Air discharge direction – Horizontal Horizontal Horizontal
①
Total cooling capacity kW 21.0 25.0 46
380-415/3/50,
Power supply V/Ph/Hz 208/3/60 380-415/3/50(60)
380-415/3/60
Heating capacity kW 4 4 6
Notes:
1. Nominal cooling condition: Return air dry bulb temperature 37.8ºC/RH20%, outdoor temperature 35ºC
2. The data in brackets are applicable to the indoor unit with electric heater & humidifier
3. Data are subject to change without prior notice
Fan quantity – 1 1 1 2 2
Full load current A 3.3, 2.5 2.5 Power supply from indoor unit
Notes: Data are subject to change without prior notice; the pipe diameter only for reference and it may be changed for the actual configuration
Net weight kg 60
67
In-row Chilled Water Cooling Product
NetCol5000-C030
Introduction
NetCol5000-C is a fan coil unit installed inside the data center, combined
together with chiller, chilled water pump and piping etc. to form a
complete cooling system. It is coupled with EC fan, and has the functions
of cooling & dehumidification. Normally, it is installed between the IT racks,
closely coupled with heat source so as to provide in-row cooling solution
for medium to high density DC. NetCol5000-C is an efficient, reliable and
simple cooling product, helps to build next generation green data center.
Application Scenarios
•• Carrier base, province/city level data center
•• ISP, EDC, IDC
•• Finance headquarter, disaster recovery data center
•• Smart city, safe city
NetCol5000-C
•• E-government
Simple
•• On-line fan maintenance: No need to switch off power.
•• Water piping: high quality imported rubber hose; threaded connection
makes installation easier and free of brazing work
•• It supports piping and cabling from both top and bottom of the unit, and
can be accessed from both front and rare
•• Leading-edge 7-inch colored touch screen features innovative one-touch 7 inch LCD true color EC fan
interface switch and provides temperature & humidity curves display of the
touch screen
last 30 days, bringing an excellent usage experience
68
Technical Specification
Notes:
1. Cooling capacity condition: Return air dry bulb temperature 37.8ºC/RH20%, Inlet/Outlet water temperature 10ºC/15ºC
2. Nominal cooling condition: The current data in brackets are applicable to the unit with electric heater & humidifier
3. The unit with electric heater & humidifier does not support up piping for without water pump
4. Data are subject to change without prior notice
69
In-row Chilled Water Cooling Product
NetCol5000-C065 & C080
Introduction
Application Scenarios
•• Carrier base, province/city level data center
•• ISP, EDC, IDC
•• Finance headquarter, disaster recovery data center NetCol5000-C065H
•• Smart city, safe city
•• E-government
Simple
7" Touch Screen ECFan
•• Digital management: 7“ colortouch screen, key parameters displayed
and uploaded to the management system such as cooling capacity, air
volume
•• Malfunction self-diagnosis: eliminate irrelevant failure reason
intelligently and save pending and maintenance time
•• Guide debugging: intelligent guide debugging, automatical logic
running, avoiding manual maloperation
70
Technical Specification
Fan Quantity / 10 12
Notice:
Cooling capacity condition: return air DB temperature 37ºC/RH24%, inlet/outletwatertemperature10ºC/15ºC
71
In-room Air Cooled Cooling Product
NetCol8000-A
Introduction
Application Scenarios
•• Data center power distribution room NetCol8000-A013U
•• Small computer room
•• Communication room
Reliable
•• 6kV surge protection level, greatly reduces the risk of lighting strike
Condenser Appearance
•• Works stably at extremely ambient temperature, with less cooling
capacity derating
Simple
•• The unit is delivered with refrigerant for 30m long pipes, fast install
on-site
•• The connectors of indoor and outdoor unit adopt welding-free design,
easy to install and maintain
72
Technical Specification
Sensible Cooling
kW 11.7 45 60 90 120
Capacity
Heating Capacity
kW 4.0 6 6 12 12
(Optional)
HumidifierCapacity
kg/h 3.0 6 6 10 10
(Optional)
1. Nominal cooling condition: Return air dry bulb temperature 24ºC/RH50%, outdoor temperature 35ºC.
2. The data in bracket is suitable for the unit with heater and humidifier.
3/8 in (outer
Power Supply V/Ph/Hz 220-240/1/50(60) Power supply from indoor unit
diameter)
FanQuantity - 2 1 2 2 2
Notice: The pipe diameter is only for reference and it may be changed based on the actual configuration. If the pipe length is longer than 60m, please contact Huawei
system engineer.
73
In-room Air Cooled Cooling Product
NetCol8000-A050D & A100D
Introduction
NetCol8000-A is composed of indoor and outdoor unit. Indoor unit is
configured with scroll compressor, large surface evaporator, EC fan, electric
humidifier and electric heater. Cooling capacity is 50kW and 100kW. And
the fan can be sunk under the floor to further improve air supply efficiency.
NetCol8000-A is an efficient, reliable and simple solution, which helps to
build next generation green data center.
Application Scenarios
•• Small and Medium sized Enterprise data center
•• Carrier base, city/district level data center NetCol8000-A Appearance
•• Financial branches
Reliable
•• Redundant design: If one circuit is faulty, the operationof the other
circuit is not affected
•• Multiple system protections: Compressor failure andabnormal pressure
protection, insufficient airflow,temperature / humidity out of limit alarm
•• Refrigerant leakage and anti-freeze protection: Whenrefrigerant is
leaked, unit switches off automatically,avoids freezing on evaporator
Simple
•• Modular design: No brazing work for unit disassembly,reduces the
Modular Design
requirement on dimensions of elevator anddoors
•• 100% front access, supports side by side installation,smallest maintenance
space in the industry
•• The control system has self-diagnosis and precautionfunctions, and it
can provide pre-maintenance tips
74
Technical Specification
Heating Capacity kW 6 12
Notice: Nominal cooling condition: Return air dry bulb temperature 24ºC/RH50%, condensing temperature 45ºC
Fan Quantity - 2
75
In-room Chilled Water Cooling Product
NetCol8000-C
Introduction
NetCol8000-C 2.0 is the in-room chilled water smart cooling product
developed by Huawei. Generally, it has a complete cooling system
by combining chillers, chilled water pumps and pipes, etc. Its cooling
capacity covers from 62kW to 253kW. The efficient, reliable and simple.
NetCol8000-C helps to build next generation of green data center.
Application Scenarios
NetCol8000-C
•• Carrier base, province/city level data center
•• ISP, EDC, IDC
•• Finance headquarter, disaster recovery data center
•• Smart city, safe city
•• E-government
Efficient
•• Pressure difference control: save 10%+ energy compared with
1. Smart cooling product 2. IT equipment
ordinary EC fan with supply and return air control
Typical applications
•• Fresh air free cooling: adjust fresh air ratio intelligently, save 30%+
energy comparison with traditional chilled water system
Reliable
•• Modular design: no effect on the operation of the other modules
even if there is one faulty module
•• Dual power sources: dual auto-switch power supply with
independent dual 6kV surge protection and power detection
•• On-line maintenance: hot swappable for control module and
auxiliary power module
Simple
Hot swapped module
•• Digital management: 7“ color touch screen, cooling capacity, air
flow and power consumption could be displayed
•• Malfunction self-diagnosis: eliminate irrelevant failure reason
intelligently and save pending and maintenance time 7h+
•• De-engineering: prefabricate components including air damper, = +
dynamic balance valve, save installation man-hour max. 10h/unit
76
Technical Specification
NetCol8000-C Technical Specification
Unit Model Unit NetCol8000-C070D NetCol8000-C130D NetCol8000-C190D
Air Direction - Downflow
Total cooling
kW 63.2 126.4 189.6
capacity①
Sensible cooling
kW 51.4 102.8 154.2
capacity
Air flow m3/h 13,500 27,000 40,500
Power supply V/Ph/Hz 380-415/3/50, 380-415/3/60
Water flow l/s 3.02 6.03 8.86
Water pressure drop kPa 62.4 85.4 92.7
②
Full load current A 4.7 (15.2) 8.9 (29.9) 13.1 (34.1)
Dimensions:W*D*H mm 900*1000*2000 1800*1000*2000 2700*1000*2000
Net weight kg 340 635 930
Notes:
1. Cooling capacity condition: Return air DB temperature 24℃/RH50%, inlet/outlet water temperature 7℃/12℃, ESP: 20Pa
77
FusionCol Indirect Evaporative Cooling
NetCol8000-E
Introduction
FusionCol is an indirect evaporative cooling product launched by
Huawei.Indirect evaporative cooling technology can extend the free
cooling time significantly, reduce the energy consumption of whole
data center. Built in DX supplemental cooling system can support
continuous cooling. All components include container body structure
are prefabricated in the factory. Box transportation support rapid
installation. Efficient, reliable and simple solution helps customer to
build a green data center.
External
Application Scenarios
•• ISP, IDC, EDC
Efficient
• “Fusion-iCooling” extend free cooling time, maximize the use of natural
cold sources
• Intelligent recommendation of water-saving & power-saving mode
• Match IT load changes in real time, control air supply accurately
• High efficiency heat exchanger, pPUE≤0.07*
• High efficiency EC fan, 30%-100% stepless adjustment
Reliable
• Redundant design of components and there is no single failure Internal
• Support dual power input and continuous cooling
• Modular system design , faulted module isolation
Simple
• Container body design, factory pre-installation and pre-test, support
fast delivery
• Supports automatic fault diagnosis and easy O&M
*Cooling Model:
• Location: London
• IT load:12MW
• Load ratio:50%
78
Technical Specification
Type NetCol8000-E220
Power format 380-415V/3PH/50/60Hz
Total capacity /Sensible capacity 220/220kW
Air Flow 55,000m³/h
Type Direct Expansion Cooling
Supplemental cooling (kW)
Capacity 22-110kW
Supply Temp/Relative Humidity 25℃/50%
Temperature & Humidity
Return Temp/Relative Humidity 38℃/25%
Indoor G4
Filter(EN779)
Outdoor G2
(Note: Cooling capacity: Indoor return air temp.38 °C (dry bulb), air supply temp 25°C (dry temp)
79
Data Center Infrastructure Management System
on
em
Data Center Infrastructure Management
System
iManager NetEco6000
Introduction
System Concepts
Digital Maintenance
•• Smart devices combined with intelligent software dramatically improve
O&M efficiency.
Intelligent Operation
•• Supporting U-position capacity management and tenant resource
analysis, NetEco6000 simplifies use of data center resources.
AI Energy Analysis
•• Optimization of data center energy use based on AI technology reduces
annual energy costs.
Security Protection
•• NetEco6000’s security protection frame helps prevent network and data
security issues.
Benefits
NetEco
6000
82
Product Features
Digital Maintenance
Feature Description Advantage Details
•The overview UI pages show data center
Provides O&M
O&M The O&M UI can be KPIs on a multi-screen grid.
overview of data
Overview customized. •Various dashboards focus on KPIs such as
center
alarms, energy efficiency, and capacity.
Several views support efficient O&M:Device
Topology of power
Provides real-teim monitoring view
Real-Time distribution and
monitoring of data •Topologies of the power distribution and
Monitor refrigeration system show
center facility refrigeration systems
the operating status.
•Layout planning of data halls
•Providing the 3D view of data center,
micro-module
Provides a 3D view of Integrated web 3D view in
3D View •NetEco6000 generates the 3D view
the data center the monitor system
automatically based on the layout of the
data center.
•Supports browsing, inquiry, masking,
redefinition, and threshold setting for each
Views povide ways alarm.
Supports alarm masking
Alarm to deal with device •Sends alarm remote notifications via SMS
with multiple rules.
alarms and email.
•Provides expert experience library that
records alarm-handling suggestions.
•Integration with Huawei IVS video system
supports browsing of real-time video.
•Provides access control for data hall,
Provides video
Security Supports access control for micro-module, and rack, using fingerprints,
surveillance and
Management each rack. passwords, and IC cards.
access control
•Generates alarms for unauthorized access,
and supports opening and closing of doors
remotely.
•Provides views of variables such as current
Monitor network security
Supports access via alarms, device real-time parameters, PUE,
Mobile Access policies to help prevent
mobile device and energy consumption.
intrusions.
•Compatible with Android 4.2.2 and above.
•Supports three layers of temperature
Identifies hot spots
Temperature The number of layers can nephogram.
through temperature
nephogram be customized •Identifies top five hot spots and cold spots
field monitoring
automatically.
•The content and inspection “routes” for
daily inspections can be customized.
Computer room Fills inspection form with
•Daily inspection tasks and data can be
Daily Inspection paperless daily report real-time monitoring data
accessed using mobile device.
via mobile device automatically
•Automatically generates daily inspection
reports.
•Creates risk tickets for the abnormal items
Tracks data center Enables closed-loop risk
Risk Management in daily inspection reports.
risks management.
•Handles closed-loop tracking of risk tickets.
•Creates, dispatches and tracks the alarm
Work orders track
Creates alarm tickets tickets.
Work Order daily operations and
directly from alarm pages •Supports remote notification via email and
maintenance work
SMS.
83
Product Features
Intelligent Operation
Feature Description Advantage Specification
•Supports capacity usage statistics, including rack
Provides capacity Manages the power
space, load-bearing, power capacity, power ports,
Capacity Analysis overview of data and network port of
cooling capacity, and network ports.
center each device.
•Provides KPI dashboard and capacity reports.
•Supports the design of rack-mounted device install
and un-install plans, including U-position, rPDU
•Supports search
socket, and network port.
for recommended
•Supports recommended installation location
installation location.
search.
•Provides U-position
Device Installation Manages IT device •Supports automatic generation of work orders
auto-discovery
Planning install and uninstall recording the installation date, location, equipment
collectors.
model, equipment installation, etc.
•Generates change
•Integrates with ITSM to exchange data
ticket for device
requirements.
installation.
•Automatically identifies changes of rack-mounted
devices using U-position auto-discovery collectors.
•Supports inventory management of IT and facility
devices, including records of activities such as device
install, transfer, uninstall, and maintenance.
•Provides IT device
Manages inventory •Records attributes of assets such as device model,
Inventory library.
information of IT and department, maintenance information, and user-
Management •Manages devices in
facility devices defined attributes.
storage area.
•Provides IT device library showing the device
models of the top manufacturers in the most recent
3 years.
•Supports allocation and pre-allocation of rack and
Tenant Resource Allocates racks to Simplifies rack
U-position resources.
Allocation specific users resource allocation
•Provides statistics of space resource allocations.
•Tracks statistics and trends of data center resource
•Analyzes tenant occupancy rates.
Operation analysis groups. •Identifies tenants whose power consumption
Tenant Resource
based on tenant •Identifies abnormal exceeds the contract limits.
Analysis
resources tenants and most •Identifies valuable tenants whose resources are
valuable tenants. almost exhausted or whose contract will soon
expire.
•Supports PUE analysis of data center, data hall and
Provides PUE of each
PUE analysis of data micro-module.
PUE Analysis data hall and micro-
center •Generates an alarm when the PUE exceeds a
module.
threshold.
•Supports energy consumption monitoring and
statistics of each data hall.
Real-time monitoring Supports energy
Power Consumption •Supports energy consumption monitoring and
of device energy monitoring of each
Monitor statistics of each rack and server.
consumption rack and server.
•Calculates electricity costs based on the energy
price.
84
Product Features
AI Energy Analysis
Feature Description Advantage Details
•cPUE analysis based on the energy
Identifies any abnormal chain identifies any abnormal points
Provides cPUE analysis
Energy Chain Analysis points of energy of energy efficiency.
based on the energy chain.
efficiency •Analyzes UPS energy efficiency to
determine UPS module sleep mode.
Adjusts the CRAC operation to reduce
Energy optimization for Optimizes cooling algorithm its energy consumption by 8%,
iCooling (air-cooled)
air-cooled systems based on AI. accounting for factors such as IT load
and temperature field.
•Adjusts the chiller system operation
Energy optimization for Optimizes cooling algorithm to reduce data center energy
iCooling (water-cooled)
water-cooled systems based on AI. consumption by 8%.
•Compatible with TOPN BMS system.
Product Features
Product Modules
Feature Description Features
3D View 3D View
Energy Efficiency Management PUE analysis, power consumption monitor
Cooling Optimization iCooling (air-cooled), iCooling (water-cooled)
Inventory Management Inventory Management
Capacity analysis, device installation planning, rack
Capacity Management
Optional Functions allocation
Tenant Management Tenant resource analysis, tenant resource allocation
Paperless Inspection Daily inspection, risk management
Work Order Work Order
Temperature Nephogram Temperature Nephogram
Mobile App Mobile Access
Northbound Interface SNMP, Web Service, and FTP
System Interfaces
Southbound Interface Third-party system integration, Third-party device monitoring
85
Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.