Shortform DTS0262
Shortform DTS0262
SHORT FORM
www.AutoSystem.ir
IÄø
Company ProĮle 3
Product Advantages 10
Approval and CerƟĮcaƟons 12
Worldwide 13
Guided Product SelecƟon 14
D5000, D5200 Series 19
• SelecƟon Table 25
• Accessories 29
Safety Relay Series 31
• SelecƟon Table 35
D1000 Series 41
• SelecƟon Table 46
• Accessories 51
Elcon Adapter 52
D6000 Series 55
• SelecƟon Table 58
• Accessories 60
D2000M Series 61
• SelecƟon Table 66
• Accessories 66
Power Supply Series 67
• SelecƟon Table 75
T3000 Series 76
Understanding Hazardous LocaƟons 78
Understanding Safety Integrity Levels 82
2 www.AutoSystem.ir DTS0262-4
www.gmintsrl.com
CÊÃÖÄù PÙÊ¥®½
In 1970 Mr. Landrini founded Elcon Instruments, which G.M. InternaƟonal’s products are installed on all wiring
has been acknowledged as an internaƟonal leader in the between safe and hazardous areas and represent a
design and manufacturing of Intrinsic Safety interface fundamental, yet oŌen under-esƟmated, layer of the
products and systems. instrumentaƟon package.
Mr. Landrini started G.M. InternaƟonal to provide state
of the art SIL rated products and services to support Intrinsically Safe interfaces provide energy limitaƟon
Intrinsically Safe applicaƟons in Oil & Gas, Petrochemical to protect from risks of explosion; at the same Ɵme
and PharmaceuƟcal Industries. they must provide the highest grade of availability to
guarantee both conƟnuous operaƟon and availability of
G.M. InternaƟonal was founded in 1993, but the core the safety layer.
Management experience remarkably exceeds over 40
years of qualiĮed acƟvity in Intrinsic Safety and industrial G.M. InternaƟonal has obtained SIL 3 FSM approval
electronics. by TÜV according to IEC 61508:2010 standard, and its
products are cerƟĮed up to SIL3, oīering the greatest
G.M. InternaƟonal’s products have been successfully levels of funcƟonal safety for high integrity and criƟcal
installed in plants all over the world, including Europe, applicaƟons.
Russia, North America, Middle and Far East and China.
A complete reference list can be requested.
MÄç¥ãçٮĦ Eø½½Ä
Laser Marking
All markings are made using a state-of-the-art laser etching machine; permanent
in every environmental condiƟon.
Marking includes complete wiring diagrams, terminal block number
assignments and cerƟĮcaƟon data.
Product Traceability
All products follow a strict traceability standard. From the batch of components to
customer assignment through every manufacturing and tesƟng steps, all data of
individual modules are stored.
StarƟng from the serial number, the complete history of any module can be traced
through all producƟon phases.
ProtecƟve G3 CoaƟng
All units are treated with a “G3” compliant silicon based coaƟng.
Such tropicalizaƟon is applied to improve electrical characterisƟcs,as well as to
protect from harsh environmental condiƟons.
High Reliability
ProducƟon is “burned-in” in an environmental chamber for 100 hours with
temperatures cycling between the lowest and highest speciĮed for the module,
thus eliminaƟng the “infanƟle mortality” problem.
4 www.AutoSystem.ir www.gmintsrl.com
CÊÃÖÄù PÙÊ¥®½
100 % TesƟng
The enƟre producƟon goes through rigorous and automated test and calibraƟon
procedures. Test bench calibraƟon is veriĮed several Ɵmes during the day to
guarantee correct and repeatable results.
Our actual Įeld return rate, veriĮed according to ISO 9000:2008 records, is lower
than 0,1%.
Made in Italy
Our products are proudly assembled, calibrated and tested in our own faciliƟes in
Villasanta, near Milan, ITALY.
Qç½®ãù Eø½½Ä
Manufacturing FaciliƟes
G.M. InternaƟonal’s products are manufactured enƟrely in our faciliƟes in
Villasanta (Milan) - Italy uƟlizing the latest technologies and machinery.
Having complete control on the manufacturing process ensures the highest level
of quality and guarantees the greatest Ňexibility for all customers’ requirements
with improved delivery Ɵme for big or small orders alike.
Manufacturing equipments are constantly renewed and updated; AutomaƟc
Test Equipment, speciĮcally developed by our engineering team, are constantly
checked and calibrated against traceable standards to ensure accuracy and
repeatability. The enƟre manufacturing process is SIL 3 cerƟĮed by TÜV.
Quality
Quality is very important to achieve customer saƟsfacƟon and market success.
G.M. InternaƟonal’s products saƟsfy customers’ expectaƟons and meet the
speciĮcaƟons of internaƟonal standards.
Safety, performance, reliability and product documentaƟon are the basic principles
of product quality. G. M. InternaƟonal has obtained ISO 9001:2008 in 2006.
HSE
GM InternaƟonal also strives to conform to latest HSE standards and conform to
all our local Health and Safety regulaƟons and requirements with conƟnuous and
extensive personnel formaƟon and hands-on training. Management is commiƩed
to the higest achievable HSE level throughout all stages of our acƟviƟes and, it is
our policy to protect our employees, clients, subcontractors and the community.
Our objecƟve is to reduce risks to the lowest level in order to achieve a HSE goal
of zero incidents, conĮrmed by OHSAS 18001:2007.
6 www.AutoSystem.ir www.gmintsrl.com
CÊÃÖÄù PÙÊ¥®½
Assembly Technology
We make use of the latest assembly technology such as SMD mounƟng of most
components including Terminal blocks and Transformers.
Soldering is performed using reŇow technology, industry highest standard.
AutomaƟc opƟcal veriĮcaƟon of all assembled plates is performed at the end of
the assembly process to weed out all Ňaws at the earliest stage.
Code of Ethics
All personell is highly qualiĮed, experienced and undergoes conƟnuous training.
G.M. employees adhere to a strict code of ethics approved by the Board of
Directors.
ප PrevenƟng accidents.
8 www.AutoSystem.ir www.gmintsrl.com
CÊÃÖÄù PÙÊ¥®½
ConƟnuous EducaƟon
ConƟnuous training and improvement of our staī ’s skills and capaciƟes are key
points to enhancing company performances and customer’s saƟsfacƟon.
G.M. InternaƟonal oīers extra courses to raise our employees awareness of the
company products and their use, in addiƟon to mandatory training on HSE, Quality
and manufacturing/tesƟng pracƟces.
Customer Training
Special courses for engineering companies, end users and system integrators are
also given both in-house and at customers sites on EX and SIL relevant standards.
SpeciĮcally, our SIL courses based on our SIL manual, have proven to be very highly
informaƟve and have gained strong popularity.
FSE Courses, cerƟĮed by TÜV Rheinland and presented by a world wide renowned
FuncƟonal Safety Expert, are provided; see our website for available dates.
The main objecƟve is to provide engineers involved in safety instrumented systems
with elementary and necessary knowledge of funcƟonal safety, based on
IEC 61508 and IEC 61511 standards.
Customer Support
G.M. InternaƟonal considers service as an integral part of customer’s requirements
and saƟsfacƟon.
Among the services we oīer:
• Cabinets’ assembly according to customer’s speciĮcaƟon and world wide
EX standards;
• System Engineering;
• Custom soluƟons tailored to customer’s special requests;
• ISO 9000:2008 cerƟĮed post sales assistance service.
• Factory Acceptance Tests (FAT) on products and assembled cabinets can be
staged in our faciliƟes in Villasanta (MB) – Italy or at any of our subsidiaries or
in the faciliƟes of our world wide system integrator partners.
PÙÊçã AòÄã¦Ý
SIL 3 according to IEC 61508/61511 BUS opƟon installaƟon on standard DIN-Rail
SIL 3 level in 1oo1 conĮguraƟon and total compliance Use of same “low proĮle” rail for Bus and non-Bus
with speciĮcaƟons for ESD, F&G, BMS. applicaƟons simpliĮes installaƟon design.
Input from Zone 0, Division 1 for all products Line Monitoring capabiliƟes
InstallaƟons are possible with all Ex ‘i’ devices (Ex ‘ia’, Available in AI, AO, DI and DO modules, both for
Ex ‘ib’, Ex ‘ic’). open and short circuit condiƟons, signalled via: dry
contact, impedance change and/or RS-485.
Marine Type Approval for oīshore and ship
applicaƟons Alarm FuncƟons
BeƩer reliability under all working condiƟons, Local and remote alarm signalling for all potenƟal
including harsh applicaƟons. failure condiƟons.
10 www.AutoSystem.ir www.gmintsrl.com
PÙÊçã AòÄã¦Ý
CerƟĮcates have been released by Det Norske Veritas in accordance to the following
world standards: ABB, BV, DNV, GL, LR, NK, RINA; and by Korean Register of Shipping.
This means our producƟon faciliƟes are periodically re-assessed throughout the whole
manufacturing process, to ensure that the highest quality standards are met.
12 www.AutoSystem.ir www.gmintsrl.com
WÊÙ½ó®
WÊÙ½ó® PÙÝÄ
GM InternaƟonal’s products are available trough a comprehensive network of Subsidiaries and Agents.
Visit our web site to Įnd an expert near you.
MILAN
TOKYO
HOUSTON SHANGAI
DUBAI
SINGAPORE
Stocking Distributors
Agents
D5030
D5032
RELAY
OUTPUT D1030
D1032
24 Vdc D5031
TRANSISTOR D5231
NO LINE OUTPUT D1031
MONITORING D1033
CURRENT D5034
OUTPUT D1034
115-230 RELAY
D1130
Vac OUTPUT
D5030
RELAY D5032
OUTPUT D1030
D1032
LOCAL AND
BUS ALARM D5031
DIGITAL D5231
TRANSISTOR
INPUT
OUTPUT D1031
24 Vdc D1033
D5030D
RELAY D1030
OUTPUT
REMOTE D1032D
ALARM OR
DUPLICATOR D5031D
TRANSISTOR D5231
OUTPUT D1031
LINE
MONITORING D1033
CURRENT D5034
TRANSPARENT
OUTPUT
D1034
REMOTE ALARM RELAY OUTPUT D1130
115-230 OR DUPLICATOR
Vac LOCAL AND D1130
RELAY OUTPUT
BUS ALARM
LOOP POWERED
NON IS SOLIDͳSTATEͳRELAY D5093
24-220 Vac/Vdc
14 www.AutoSystem.ir www.gmintsrl.com
Gç® PÙÊçã S½ã®ÊÄ
D5040
D5240T
D1040
I.S.
NE/ND D1041
NO LINE DC OUTPUT D1042
LOAD
MONITORING D1043
24 Vdc D1045
D1046
RELAY OUTPUT D1044
NE LOAD D5280
DC OUTPUT D5281
ND LOAD
D5091
D5090-086
D5291
NON LOOP ND LOAD
D5290-078
DIGITAL I.S. POWERED
OUTPUT D1092
RELAY
OUTPUT D5290-078/SA
D5090
D5290
D5290-SA
D5290-078
NE LOAD
D5290-079
D5290-080
D5290-084
D1092
D1092-069
LOOP D5048
DC OUTPUT NE/ND LOAD
POWERED D1048
I.S.
D5049
24 Vdc DC OUTPUT NE/ND LOAD
LINE D1049
MONITORING
D5293
NE LOAD
NON RELAY D1093
24 Vdc OUTPUT
I.S. D5294
ND LOAD
D1093
INVERTER D5095S
D5011
D5014
D5212
D1014
D1010
2 WIRE D1012
TX
D5254
+ ALARM
D1054
D5014D
D1010D
DUPLICATOR
ANALOG D5212Q
INPUT D1012Q
D5014
D1010
D5254
3/4 WIRE + ALARM D1054
TX
D1053
D5014D
DUPLICATOR
D1010D
D5020
24 Vdc
NO LINE D1020
MONITORING
ANALOG LOOP POWERED D1022
OUTPUT D1020
LINE OPEN CIRCUIT
24 Vdc
MONITORING D5020
OPEN CIRCUIT
D5072
D1072
D5273
TC, RTD, Pot + ALARM
D1073
TEMPERATURE D5072D
DUPLICATOR
D1072D
16 www.AutoSystem.ir www.gmintsrl.com
Gç® PÙÊçã S½ã®ÊÄ
D1063
TRANSPARENT
D5064
WEIGHING
D1064
+ 4-20 mA OUT + ALARM
D5263
D1035
D5035
FREQUENCY
D1060
+ 4-20 mA OUT + ALARM
D5060
D1062
VIBRATION
D5062
ENCODER D5265
D5000
ÝÙ®Ý
ENHANCED INTRINSICALLY SAFE ISOLATORS
SUITABLE FOR SIL 2 AND SIL 3 APPLICATIONS
D5000
CHARACTERISTICS
TerminaƟon Board connector
DIN-Rail lock
Laser engraving
on enƟre enclosure and terminal 12 mm
blocks to provide accurate, safe and
permanent marking of Intrinsic Safety
parameters, schemaƟc diagrams,
connecƟons and instrucƟons.
20 www.AutoSystem.ir www.gmintsrl.com
D5000 SÙ®Ý
FãçÙÝ
Enclosure CharacterisƟcs
Blue Terminal Blocks Grey Terminal Blocks
for Hazardous Area for Safe Area • High channel density result from innovaƟve circuit
connecƟons connecƟons design using advanced surface mount components.
• Plug-in screw terminal blocks to secure terminaƟon
up to 2.5 mm2.
• ConĮguraƟon components are easily accessed by
removing side cover.
22 www.AutoSystem.ir www.gmintsrl.com
D5000 SÙ®Ý
TÙîÄã®ÊÄ BÊÙÝ
CharacterisƟcs
• Suitable to accept up to 8/16 D5000 or D5200 SIL 3 modules 12mm/22mm
wide, single or double channel, for up to 64 total channels.
• AI - AO - DI - Temperature: double channels.
• DO - Signal converter, Encoders, Safety Relay: single channel.
• 24 Vdc Power supply terminal blocks can be disconnected from the board
without disrupƟng the power to other boards connected in series.
• Boards are available with custom connectors to directly interface any system
PLC / DCS / ESD.
• Boards are available also for 8+2 and 16+2 modules:
16 ch output connector
Fault and Supply Relays
CÊÄ¥®¦çÙã®ÊÄ
SWC5090 SoŌware
The SWC5090 soŌware is designed to provide a PC user interface to conĮgure
suitable D5000, D5200 modules.
24 www.AutoSystem.ir www.gmintsrl.com
D5000 S½ã®ÊÄ T½
SIL
D5011S 1
4-20 mA 3
4-20 mA 20-30
2-Wires Tx only;
(source only) Vdc
Smart compaƟble SIL
D5011D 2
3
SIL
D5014S 1
3
4-20 mA 4-20 mA
2-Wires (source or sink)
20-30 SIL
D5014D AcƟve or Passive Tx; 2
Smart compaƟble
Vdc 3
Two SIL
D5014D 1
ANALOG IN
duplicated outputs 3
4-20 mA SIL
D5212Q 4
+ Modbus 2
One SIL
D5212Q Quadriplicated output 1
+ Modbus 2
D5020S SIL
ANALOG OUT
4-20 mA 4-20 mA 1
Analog Signal to I/P Bus powered 3
20-30
Converters, Electrovalves, signal from DCS, PLC or
Vdc
D5020D Actuators and Displays; other control devices. SIL
Smart compaƟble Two duplicated outputs. 2
3
SIL
D5034S Voltage free Contact, 1
Transparent repeater of 3
Proximity Switch 20-30
input status
Line fault detecƟon Vdc
0 to 8 mA range SIL
D5034D Isolated inputs 2
3
26 www.AutoSystem.ir www.gmintsrl.com
D5000 S½ã®ÊÄ T½
SIL
D5040S 1
Loop Powered control Loop + 3
NE solenoid valve,
signal from safety 18-30
other control devices.
PLC, DCS Vdc SIL
DIGITAL OUTPUT DRIVER
D5040D 2
3
Loop + SIL
4-20 mA
D5048S NE solenoid valve, 1 20-30
(source or sink)
Vdc 3
other control devices.
Line open/short fault Loop Powered control
detecƟon reŇected on PLC. 20-30 SIL
D5049S signal from safetyPLC, 1
DCS
Vdc 3
0-50 KHz
SIGNAL
CONV.
20-30 SIL
D5265S Intrinsically Safe Encoder Transparent repeater 1
Vdc 2
mA (source/sink) or V
ISOLATOR CONV.
for more informaƟon and details about Power Supplies, see secƟon at page 75
SAFETY
RELAYS
for more informaƟon and details about Safety Relays, see secƟon at page 35
28 www.AutoSystem.ir www.gmintsrl.com
D5000 AÝÝÊÙ®Ý
MOR015 Plug-in terminal block male, verƟcal out, for Power Bus.
MOR017 Plug-in terminal block male, horizontal out, for Power Bus.
MOR022 Plug-in terminal block female, horizontal out, for Power Bus.
SAFETY RELAYS
CHARACTERISTICS
IntroducƟon ApplicaƟons
When a load cannot be driven directly by a safety Some of the most common applicaƟons for a SIL 2 or
controller, an interposing relay becomes a requirement. SIL 3 relay are:
In example: when the power required to switch the load • Control of Solenoid Valves (SOV) in ESD and F&G
is greater than what can be handled by the controller; or systems;
the voltage is diīerent than the typical 24Vdc provided • Control of Beacons, Horns, and similar signaling devices;
by controller; or when mulƟple contacts are required to • Controls in Burner Management Systems (BMS);
be driven by the same control signal. • Control of AC or DC Motors.
SIL cerƟĮed safety relays are a requirement to meet SIL cerƟĮed relays are also used for feed-back signals
the necessary Risk ReducƟon Factor (RRF) when and as interposing relays between diīerent systems.
switching a load ON or OFF, in a IEC 61508/61511
Safety Instrumented FuncƟon (SIF). SIL cerƟĮed relays
guarantee that the safety funcƟon is met with a suitable
and known probability of failure (PFD).
With the increased implementaƟon of “SIL” standards
the market for SIL cerƟĮed relays is growing very fast in
all Įeld and applicaƟons and is no longer an exclusivity of
the Oil & Gas sector. An example is controls and braking
systems for trains.
Safety FuncƟon
In order to properly select a SIL relay, special aƩenƟon
must be given to the Safety FuncƟon (SF) of the SIF
where the SIL relay will be used, since diīerent relay
matrices are used to achieve the required SF.
The two most typical SFs are De-Energized to Safety or
to Trip (DTS) and Energized to Safety or to Trip (ETS);
however, combinaƟons of the two are also possible.
• DTS: Used mostly in ESD system to disconnect power
to safety valves which are Normally Energized; it is
achieved by removing power to the load through
opening of the DO signal (0 volts or “0”) and the
consequenƟal opening of the relay contacts.
• ETS: Used mostly in F&G system to energize deluge
valves which are Normally De-Energized or dormant;
it is achieved by providing power to the load through
the closing of the DO signal (24 volts or “1”) and the
consequenƟal closing of the relay contacts.
• CombinaƟons: SomeƟmes the relay funcƟon must be
inverted to achieve the required SF. Meaning that the
control signal is 1 but the load must be 0; or vice versa
0 the control signal and 1 the load.
32 www.AutoSystem.ir www.gmintsrl.com
S¥ãù R½ùÝ
Line & Load Monitoring trip) or the relay anchors can parƟally move degrading
and shortening the life of the relay itself. If pulse test is
SIL cerƟĮed relays are used in SIFs which are always to be used a SIL cerƟĮed relay with a Įltering circuit on
criƟcal loops and careful consideraƟon should be given the front end should be used such as GMI D5000 series
to the requirement of Line and Load Monitoring. which are fully compaƟble to Line Monitoring pulses
If it is true that in a DTS SF a wire or a coil failure will from all system manufacturers.
lead to safety, the same cannot be told of an ETS SF • Extension of Line Monitoring through the SIL Relay:
where a failure would lead to a dangerous condiƟon Control system diagnosƟc capabiliƟes discussed above
which, if undetected, would lead to an unsafe status and are designed to perform line monitoring when no relay
consequenƟal loss of SIL level. Some useful applicaƟons is present between the control system and the load.
for Line Monitoring in DTS SFs are also possible; in As soon as a relay is placed in the loop, the diagnosƟc
example, to monitor the status of the coil to prevent funcƟon stops at the relay input circuit (coil).
spurious trips or to verify the condiƟon of the individual • To perform full line monitoring from the Control System
coil in a redundant coil SOV. A last consideraƟon for to the Load a SIL relay with built-in diagnosƟc circuit
Normally De-Energized systems such as F&G where it is is required. These relays are able to diagnose a failure
not basically possible to perform line monitoring through in the Įeld wiring and load providing an alarm to the
convenƟonal methods. control system or other dedicated alarm channels.
When Line & Load Monitoring is required, three separate • Line Monitoring FuncƟons: A SIL relay with
consideraƟons must be given: built-in diagnosƟcs can perform two basic kind
• Pulse Test CompaƟbility: The majority of today’s control of line monitorings: detecƟon of open circuit
systems such as ESD or F&G can generate a pulse (acƟve and/or short circuit; both will lead to an unsafe
or passive) to verify line integrity. The pulse length condiƟon for a Normally De-Energized SIF and can
and frequency varies from system to system but, in all lead to a spurious trip in a Normally Energized SIF.
cases, it can negaƟvely aīect the relay funcƟonality! A Monitoring of the supply line should also be taken
relay is not designed to be pulsed and, depending on into consideraƟon since loss of power leads to unsafe
the pulse length, the relay can change status (spurious condiƟon in an ETS SF.
34 www.AutoSystem.ir www.gmintsrl.com
S¥ãù R½ùÝ S½ã®ÊÄ T½
Field SIL
Model ConnecƟons RaƟng
device level
D5090S 4A
250 Vac
1000 VA
4A SIL
250 Vdc 3
120 W
D5090S- 4A
086 250 Vac
1000 VA
4A SIL
250 Vdc 3
120 W
Coil
Can be used to disconnect one or both supply lines (see Įgures).
D5091S 4A
250 Vac
1000 VA
SIL
4A
250 Vdc
3
120 W
Relay with ND or NE Coil and ND Load (0-0 or 1-0).
SIL 3 funcƟon: connect Load by connecƟng input (1-1) or 24 Vdc
connect Load by disconnecƟng input (0-1) (see Įgures). Coil
To disconnect both supply lines, use two D5091S units in parallel.
D5291S 10 A
250 Vac
2500 VA
SIL
10 A
250 Vdc
3
300 W
Relay with ND or NE Coil and ND Load (0-0 or 1-0).
SIL 3 funcƟon: connect Load by connecƟng input (1-1) or 24 Vdc
connect Load by disconnecƟng input (0-1) (see Įgures). Coil
To disconnect both supply lines, use two D5091S units in parallel.
Field SIL
Model ConnecƟons RaƟng
device level
D5290S 10 A
250 Vac
2500 VA
10 A SIL
250 Vdc 3
300 W
D5090S 10 A
/SA 250 Vac
2500 VA
SIL
10 A
250 Vdc
3
300 W
Relay with NE Coil and Load (1-1).
SIL 3 funcƟon: disconnect Load by disconnecƟng input (0-0). 24 Vdc
SAFETY RELAYS
Can be used to disconnect one or both supply lines (see Įgures). Coil
InstallaƟon in safe area only and not compaƟble with pulse diagnosƟc.
D5290S 5A
-078 250 Vac
1250 VA
5A SIL
250 Vdc 3
175 W
Relay for NE/ND Load with NE/ND Coil for interrupƟng up to 4 loads. 24 Vdc
SIL 3 funcƟon: conĮgurable via external wiring. Coil
Can be used to disconnect one or both supply lines (see data sheet).
D5290S 5A
-078/SA 250 Vac
1250 VA
5A SIL
250 Vdc 3
175 W
Relay with NE Coil and NE/ND Load for interrupƟng up to 4 loads. 24 Vdc
SIL 3 funcƟon: conĮgurable via external wiring. AC Coil. Coil
Can be used to disconnect one or both supply lines (see data sheet).
36 www.AutoSystem.ir www.gmintsrl.com
S¥ãù R½ùÝ S½ã®ÊÄ T½
Field SIL
Model ConnecƟons RaƟng
device level
5A
D5290S 250 Vac
-079 1250 VA
5A SIL
250 Vdc 3
175 W
Relay with NE Coil and NE/ND Load for interrupƟng up to 4 loads. 115 Vac
SIL 3 funcƟon: conĮgurable via external wiring. AC Coil. Coil
Can be used to disconnect one or both supply lines (see data sheet).
D5290S 5A
-080 250 Vac
1250 VA
5A SIL
250 Vdc
3
175 W
Coil
Can be used to disconnect one or both supply lines (see Įgures).
D5290S 5A
-084 250 Vac
1250 VA
5A SIL
250 Vdc 3
175 W
Relay with NE Coil and NE/ND Load for interrupƟng up to 4 loads. 110 Vac
SIL 3 funcƟon: conĮgurable via external wiring. AC Coil. Coil
Can be used to disconnect one or both supply lines (see data sheet).
D5293S 10 A
250 Vac
2500 VA
10 A SIL
250 Vdc 3
300 W
Relay with NE Coil and Load (1-1).
SIL 3 funcƟon: disconnect Load by disconnecƟng input (0-0). 24 Vdc
Can be used to disconnect both supply lines (see Įgures). Coil
With smart line and load diagnosƟc funcƟon. Modbus RS-485 output
Field SIL
Model ConnecƟons RaƟng
device level
D5294S 10 A
250 Vac
2500 VA
10 A SIL
250 Vdc 3
300 W
Relay with NE Coil and Load (1-1).
SIL 3 funcƟon: disconnect Load by disconnecƟng input (0-0). 24 Vdc
Can be used to disconnect both supply lines (see Įgures). Coil
With smart line and load diagnosƟc funcƟon. Modbus RS-485 output.
D5295S 10 A
250 Vac
2500 VA
10 A SIL
250 Vdc 3
300 W
Relay with NE Coil and ND Load (1-0).
SIL 3 funcƟon: connect Load by disconnecƟng input (1-0). 24 Vdc
SAFETY RELAYS
D1092S 3A
250 Vac
750 VA
3A SIL
125 Vdc 3
120 W
D1092D 3A
250 Vac
750 VA
3A SIL
125 Vdc 3
120 W
Dual channel Relay with NE and ND Coil and Load (1-1 , 0-0).
SIL 3 funcƟon NE: disconnect Load by disconnecƟng input (0-0). 24 Vdc
SIL 3 funcƟon ND: connect Load by connecƟng input (1-1). Coil
Can be used to disconnect two loads or both supply lines.
38 www.AutoSystem.ir www.gmintsrl.com
S¥ãù R½ùÝ S½ã®ÊÄ T½
Field SIL
Model ConnecƟons RaƟng
device level
D1092S 3A
-069 250 Vac
750 VA
3A SIL
125 Vdc 3
120 W
Relay with NE Coil and Load (1-1) and ND Coil and NE Load (0-1). 24 Vdc
SIL 3 funcƟon NE: disconnect Load by disconnecƟng input (0-0). Coil
SIL 3 funcƟon ND: disconnect Load by connecƟng input (1-0).
D1092D 3A
-069 250 Vac
750 VA
SAFETY RELAYS
SIL
3A
125 Vdc
3
120 W
Relay with NE Coil and Load (1-1) and ND Coil and NE Load (0-1).
SIL 3 funcƟon NE: disconnect Load by disconnecƟng input (0-0). 24 Vdc
SIL 3 funcƟon ND: disconnect Load by connecƟng input (1-0). Coil
Can be used to disconnect two loads or both supply lines.
D1093S 3A
250 Vac
750 VA
SIL
3A
125 Vdc
3
120 W
Dual channel Relay with NE and ND Coil and Load (1-1 , 0-0).
SIL 3 funcƟon NE: disconnect Load by disconnecƟng input (0-0). 24 Vdc
SIL 3 funcƟon ND: connect Load by connecƟng input (1-1). Coil
With line and load diagnosƟc funcƟon.
Field
Model ConnecƟons RaƟng SIL level
device
D5093S
SIL
Solid state NE Relay, 120 VAC input drive, 24 VDC rated voltage free
3
output contact. Input/Output isolaƟon.
SIL 3 funcƟon NE: remove AC drive to open PLC input circuit.
SAFETY RELAYS
D5093D
Dual Solid state NE Relays, 120 VAC input drive, 24 VDC rated SIL
voltage free output contact 3
Input/Output/Channel isolaƟon
SIL 3 funcƟon NE: remove AC drive to open PLC input circuit.
40 www.AutoSystem.ir www.gmintsrl.com
D1000 SÙ®Ý
D1000
ÝÙ®Ý
INTRINSICALLY SAFE ISOLATORS
SUITABLE FOR SIL 2 AND SIL 3 APPLICATIONS
D1000
CHARACTERISTICS
Safe Area Terminal blocks
with engraved idenƟĮcaƟon
114.5 mm
22.5 mm
42 www.AutoSystem.ir www.gmintsrl.com
D1000 SÙ®Ý
FãçÙÝ
General Features High Performance
• More than 30 modules suitable for SIL 3 - SIL 2 • High signal transfer accuracy and repeatability.
applicaƟons according to IEC 61508, IEC 61511. • Advanced circuitry provides low heat dissipaƟon,
• Single channel versions available if required, ensuring modules run cool despite their high
to provide single loop integrity on Emergency Shut funcƟonality.
Down and Fire & Gas applicaƟons. • Low power consumpƟon.
• ConĮguraƟon using DIP switch for easy Įeld setup. • SMD manufacturing for a long and reliable life.
• LED indicaƟon for power, signal status and line fault
condiƟons.
• Modules accept DC power supply over a wide range
for 12 or 24 Vdc applicaƟons.
• 2 modules (D1130 - D1180) can be powered from
85 to 264 Vac, 50-400 Hz, or from 100 to 350 Vdc. Wide FuncƟonality
• Wide operaƟng temperature range (-20 / +60°C).
• Wide range of Digital and Analog I/Os.
• Relay contacts rated for 2 A to directly switch high
loads.
• Three port galvanic isolaƟon to eliminate noise,
ground loop problems and to provide Intrinsic Safety
Enclosure CharacterisƟcs without a high integrity safety earth connecƟon.
• High channel density resulƟng from innovaƟve • Line fault alarm detects open or short circuit of Įeld
circuit design using advanced surface mount cables.
components. • OpƟonal Power Bus enclosure.
• Single, dual or quad channel models.
• Plug-in screw terminal blocks to secure terminaƟons
up to 2.5 mm2.
• Plug-in PCB can be removed for service or
maintenance operaƟons.
P»®Ä¦
High Packing Density
• 35 mm (Top Hat) DIN-Rail.
• Ultra slim 4 channels 22.5 mm wide DIN-Rail mounƟng
modules.
• 6 mm per channel.
• Up to 176 I/O channels per meter of DIN-Rail.
• Power Bus enclosure allows a signiĮcant reducƟon in cables,
costs and space.
PÊóÙ BçÝ
Enhanced Power Bus MounƟng
24 Vdc power supply voltage can be applied to the
module, by connecƟng the voltage directly to the
plug-in Terminal Block (3+, 4-) of each module, or via
Power Bus System.
The system consists of a standard Din-Rail Bar and
modules with Bus Connectors (female on one side
and male on the opposite side) of 8 A Capacity.
It is always possible to remove modules, without
POWER BUS CONNECTOR POWER BUS CONNECTOR disconnecƟng the connectors, because modules are
MALE SIDE FEMALE SIDE p lug-in types. Contacts (3+, 4-) on the Terminal Block
are omiƩed to avoid accidental short circuits on the
Power Bus.
TÙîÄã®ÊÄ BÊÙ
PBCO Series
G.M. InternaƟonal oīers many soluƟons for Customized
Boards for an easy integraƟon with instrumentaƟon of
manufacturers like Invensys Foxboro, ABB, Triconex,
Yokogawa, Honeywell, HIMA and many more.
New Board models are engineered on customer request for
any system or applicaƟon: contact us for details.
44 www.AutoSystem.ir www.gmintsrl.com
D1000 SÙ®Ý
CÊÄ¥®¦çÙã®ÊÄ
PPC 1090 Pocket Portable ConĮgurator
The PPC1090 is a small and handy Pocket Portable ConĮgurator suitable
to program conĮguraƟon parameters of D1000 series modules like:
type of input Sensors, input and output Ranges, Burnout condiƟons,
High/Low Alarm mode, Relay NE/ND, Alarm Trip Point, Hysteresis value
and ON/OFF Alarm delays.
The ConĮgurator is powered by the unit and can be plugged in without
disconnecƟng the module.
SWC1090 SoŌware
The SWC1090 soŌware is designed to provide
a PC user interface to conĮgure programmable
D1000 modules.
It easily allows the user to:
• Read and write conĮguraƟon parameters to the
units;
• Store and restore data to and from local hard
drive for backup or archive;
• Load factory default conĮguraƟons;
• Monitor Input values via USB/COM port;
• Print a report sheet containing conĮguraƟon
parameters and addiƟonal informaƟon.
4-20 mA SIL
D1010S 0-20 mA 1
3
(source or sink)
4-20 mA or
0-20 mA 1-5 V 20-30 SIL
D1010D 2
2/3-Wires Tx 0-5 V Vdc 3
Smart compaƟble
SIL
D1010D Two duplicated outputs 2
3
4-20 mA 4-20 mA
ANALOG IN
D1014S 4-20 mA 1
4-20 mA
(source or sink) 10-30
2-Wires Tx
or Vdc
Hart compaƟble
D1014D 1-5 V 2
4-20 mA
SIL
0-20 mA 4-20 mA
ANALOG OUT
D1020S 1
Analog Signal to 0-20 mA 2
20-30
I/P Converters, Bus powered
Vdc
Electrovalves, signal from DCS, PLC or SIL
D1020D Actuators and Displays other control devices. 2
Smart compaƟble
2
D1022S 1 -
FIRE & GAS
1 to 40 mA
DETECTOR
1 to 40 mA Loop
Fire/Smoke Detector
to DCS, PLC or powered
or
other control devices
D1022D Loop powered 2 -
46 www.AutoSystem.ir www.gmintsrl.com
D1000 S½ã®ÊÄ T½
SIL
D1034S Voltage free Contact, Transparent repeater 1
3
Proximity Switch of input status 10-30
Line fault detecƟon 0 to 8 mA range Vdc
Isolated inputs SIL
D1034D 2
3
Electrovalve, Audible
D1040Q 4
Alarm or other devices SIL 2
Bus
powered
D1041Q LED Voltage free Contact, 4
Logic Level,
21.5-30
Loop powered 24 Vdc or
Vdc
Electrovalve, Audible from DCS, PLC or
D1042Q other control devices 4
Alarm or other devices
SIL 3
Loop
Electrovalve, Audible powered
D1043Q 4
Alarm or other devices
DIGITAL OUT
48 www.AutoSystem.ir www.gmintsrl.com
D1000 S½ã®ÊÄ T½
RS-485, RS-422
D1061S RS-422, 1 20-30 Vdc -
up to 1.5 Mbit/s
RS-232
VIBRATION
INTERFACE
Transparent
D1063S 1 -
LOAD CELLS
20-30
D1080D 2 -
Vdc
3-WIRES SENSOR
85-264
Electro-opƟc, Vac
D1180D 2 -
photo-cells 100-350
and other devices Vdc
2 Voltage free
14-30
D1081D SPST optocoupled 2 -
Vdc
OC transistors
SIL
D1072S 4-20 mA, 0-20 mA 1
(source) 2
Universal TC, or
3/4-Wires RTD, 1-5 V, 0-5 V, 10-30 SIL
D1072D 2-10 V, 0-10 V 2
PotenƟometer, Vdc 2
TEMPERATURE CONVERTRS
mV
SIL
D1072D Two duplicated outputs 2
2
D2010M, D2011M
0 to 20 mV or
Separately powered
D1094Q 0 to 40 mV to 4 - -
0-5 V, 0-10 V
D2010M, D2011M
SUPPLIES
POWER
for more informaƟon and details about Power Supplies, see secƟon at page 65
SAFETY
RELAYS
for more informaƟon and details about Safety Relays, see secƟon at page 38
50 www.AutoSystem.ir www.gmintsrl.com
D1000 AÝÝÊÙ®Ý
MCHP065 DIN-Rail Anchor for terminal block side of the Power Bus
MOR015 Plug-in terminal block male, verƟcal out, for Power Bus
MOR017 Plug-in terminal block male, horizontal out, for Power Bus
MOR022 Plug-in terminal block female, horizontal out, for Power Bus
EI1000ADP SERIES
G.M. InternaƟonal oīers conƟnuity in the service of Elcon Instruments
D1000 series (no longer available from the manufacturer).
Features
• ATEX, FM, FM-C CerƟĮcaƟons.
• Interchangeability with Elcon 1000 Series modules.
• Possibility to replace Elcon modules without modifying
any wiring or connecƟons.
• Use of the same Elcon boards.
• IdenƟĮcaƟon using the same Elcon part-number.
52 www.AutoSystem.ir www.gmintsrl.com
E½ÊÄ AÖãÙÝ
D6000
CHARACTERISTICS
TerminaƟon Board connector
DIN-Rail lock
Laser engraving
on enƟre enclosure and terminal 12 mm
blocks to provide accurate, safe and
permanent marking of Intrinsic Safety
parameters, schemaƟc diagrams,
connecƟons and instrucƟons.
56 www.AutoSystem.ir www.gmintsrl.com
D6000 SÙ®Ý
Terminal Blocks
Terminal Blocks for for connecƟng
Field connecƟons to control room
Features
For enclosure characterisƟcs, Power Bus,
TerminaƟon Board mounƟng and conĮguraƟon
tools refer to D5000 Series (see pages 22-24)
SIL
D6011S 1
4-20 mA 2
4-20 mA 20-30
2-Wires Tx only;
(source only) Vdc
Smart compaƟble SIL
D6011D 2
2
SIL
D6014S 1
2
4-20 mA 4-20 mA
2-Wires (source or sink)
20-30 SIL
D6014D AcƟve or Passive Tx; 2
Smart compaƟble
Vdc 2
Two SIL
D6014D 1
ANALOG IN
duplicated outputs 2
4-20 mA SIL
D6212Q 4
+ Modbus 2
One SIL
D6212Q Quadriplicated output 1
+ Modbus 2
SIL
4-20 mA 4-20 mA
ANALOG OUT
D6020S 1
Analog Signal to I/P Bus powered 2
20-30
Converters, Electrovalves, signal from DCS, PLC or
Vdc
Actuators and Displays; other control devices. SIL
D6020D Smart compaƟble Two duplicated outputs. 2
2
58 www.AutoSystem.ir www.gmintsrl.com
D6000 S½ã®ÊÄ T½
MOR017 Plug-in terminal block male, horizontal out, for Power Bus
MOR022 Plug-in terminal block female, horizontal out, for Power Bus
60 www.AutoSystem.ir www.gmintsrl.com
D2000M SÙ®Ý
D2000M
ÝÙ®Ý
INTRINSICALLY SAFE MULTIPLEXER
FOR ANALOG AND DIGITAL INPUTS FROM ZONE 0
D2000M
CHARACTERISTICS
Features
• High density, up to 256 Analog Inputs (TC, RTD, mV) and
up to 128 digital inputs (contact / proximity) in the same
system (expandable up to 7936 inputs)
• Robust IsolaƟon (± 200 V channel to channel), provides high
immunity against interference and ground loops
• Intrinsically safe for installaƟon in Zone 1 or 2
• Field units can be placed up to 5 km from Gateway
• High accuracy 18 bit A/D converter
• Redundant communicaƟon lines
• Programmable via PC (RS232) and Modbus (RS485)
• Repeats input contacts via Relay or Transistor outputs
• Reduces Įeld wiring and installaƟon costs
• Eliminates the need of PLC - DCS I/O cards.
• Field unit operaƟng temperature: - 40 to + 60 °C.
• AISI 316 stainless steel enclosures are available for Įeld units
(Series GM2300).
• Gateway D2050M can be installed in Zone 1 / Div. 1 by using
an explosion proof enclosure.
62 www.AutoSystem.ir www.gmintsrl.com
D2000M SÙ®Ý
D2050M
• GATEWAY/POWER SUPPLY MULTIPLEXER UNIT
• II (1) G [Ex ia Ga] IIC
• Supply 24 V - 350 mA
• Redundant MODBUS RTU - RS485 lines up to 115200 bauds
• 1 RS-232 line for conĮguraƟon via PC
• Suitable to drive contact/proximity output repeaters
• Safe Area InstallaƟon or Zone 1 / Div 1 when mounted in an
explosion proof housing
• OperaƟng Temperature - 20 to + 60 °C.
D2010M - D2011M
• ANALOG / TEMPERATURE MULTIPLEXER UNIT
• II (1) 2G Ex ia [ia Ga] IIC T4 Gb
• 16 Channels per Unit, each for 2-3-4 wire RTD, Pt100, Pt50,
Ni 100, Cu100, Cu53, Cu50, Cu46, TC Type A1, A2, A3, B, E, J,
K, L, Lr, N, R, S, T, U.
• Up to 16 Units per System
• 256 Channels are scanned in 1700 ms
• Redundant CommunicaƟon with gateway D2050M
• PC Programmable via SWC2090 soŌware
• Zone 1 / Div. 1 InstallaƟon
• OperaƟng Temperature - 40 to + 60 °C.
D2030M
• SWITCH / PROXIMITY MULTIPLEXER UNIT
• II (1) 2G Ex ia [ia Ga] IIC T4 Gb
• 32 Input Channels per Unit
• Up to 4 Units per System
• Input from Contact-Proximity Sensors
• 128 Channels are scanned in 50 ms
• Redundant CommunicaƟon with D2050M Gateway
• PC Programmable via SWC2090 soŌware
• Zone 1 / Div. 1 InstallaƟon
• OperaƟng Temperature - 40 to + 60 °C
D2052M - D2053M
• CONTACT / PROXIMITY OUTPUT REPEATER
• 32 Isolated Channels with SPDT Relay contacts (D2052M)
or Open Collector Transistors (D2053M)
• 128 Channels are scanned in 50 ms
• OperaƟng Temperature - 20 to + 60 °C
• Safe Area InstallaƟon or Zone 1 / Div. 1 when mounted in an
explosion proof housing.
SYSTEM ARCHITECTURE
D2000M MulƟplexer accepts both analog and
digital inputs in the same system allowing the user to
choose whatever conĮguraƟon Įts his applicaƟon best
in terms of cost and cabling.
The following are two examples of achievable system
architectures.
64 www.AutoSystem.ir www.gmintsrl.com
Mç½ã®Ö½ø®Ä¦
MULTIPLEXING TECHNIQUE
Signal Data AcquisiƟon MulƟplexing in Hazardous Area
In industrial processes it is a common need to acquire For applicaƟons in classiĮed Hazardous Areas each
a relevant number of temperatures, pressures, Ňows, signal must be protected from the risk of causing an
levels and other process variables as well as the igniƟon of Ňammable mixtures: this requires a safety
status of switches or proximitors and to collect all barrier for each input channel.
these data in a single remote collecƟon area (i.e. in By using an Intrinsically Safe cerƟĮed mulƟplexer
a control room) where a PLC (Programmable Logic soluƟon, protecƟon must be applied only to the
Controller) or a Process Computer collects all data for communicaƟon lines, decreasing complexity,
monitoring purposes and availability to operators. maintenance and costs.
SCADA (Signal CondiƟoning And Data AcquisiƟon)
equipments are parƟcularly suited for this purpose.
Typical applicaƟons are Furnaces, Cracking Towers,
GasiĮers, Reactors, DisƟllers, Separators, Oxidizers, When mulƟplexing is the only viable
Tank Monitoring, Flare Stacks. soluƟon
Modern micro electronics permit fast, accurate
and stable Analog to Digital conversion, high speed In case of revamping or exspanƟon in the plant, the
compuƟng, sophisƟcated intelligence and powerful space for adding cables may be limited or the few
measuring capabiliƟes. exisƟng spare cables may be the only ones that can be
All this performance can be packed into compact, used. Radio Frequency links, beside costs and licensing
reliable units that can operate in harsh environments. problems, suīer data security and reliability issues.
MulƟplexers are a typical SCADA mulƟ channel MulƟplexing oŌen becomes the only pracƟcal
equipment that can be located in the Įeld close to the soluƟon.
process area where the input channels can be
connected with shorter lines.
All input channel signals are converted in a numeric
form and transmiƩed to a remote locaƟon via a single
or redundant communicaƟon line.
Field Ch.
Model Hazardous Area Safe Area Supply
device per unit
Universal TC,
D2010M 16
3/4-Wires RTD, mV
D2050M Gateway
Universal TC, via redundant Supplied by
INTRINSICALLY SAFE MULTIPLEXER
D2000M AÝÝÊÙ®Ý
Image Code DescripƟon
66 www.AutoSystem.ir www.gmintsrl.com
POWER SUPPLY
POWER
SUPPLY
INTRINSICALLY SAFE AND
NONͳINCENDIVE POWER SUPPLIES
POWER SUPPLIES
MODELS
PSD1000
Universal Input Power Supply for D1000 Series Isolators (PS)
• Supply 90 - 265 Vac
• Output 24 Vdc, 500 mA
• 2 Units can be paralleled for redundancy or addiƟonal power
• Remote indicaƟon for Power Failure
• InstallaƟon adjacent to D1000 Series Modules, without Safety distance of
50 mm, because Supply and Output Terminal Blocks are on the same side
• Zone 2 / Div. 2 installaƟon
PSD1001
SIL 2 / SIL 3 4 Channels Intrinsically Safe Power Supply (PS)
• II (1) G [Ex ia Ga] IIC; I M1 [Ex ia Ma] I
• 4 Independent Outputs 15 V, 20 mA
• Input from Zone 0 / Div. 1
• Zone 2 / Div. 2 installaƟon
• Flexible modular mulƟple output capability
• Output short circuit proof and current limited
• High Reliability, SMD components
• High Density, four channels per unit
• SimpliĮed installaƟon using standard DIN Rail and plug-in terminal blocks.
PSD1001C
SIL 2 / SIL 3 1 Channel Intrinsically Safe Power Supply (PS)
• II (1) G D [EEx ia] IIB; I M2 [EEx ia]
• 1 Output 13.5 V - 100 mA or 10 V - 150 mA
• Input from Zone 0 / Div. 1
• Zone 2 / Div. 2 installaƟon
68 www.AutoSystem.ir www.gmintsrl.com
PÊóÙ SçÖÖ½®Ý
PSU1003
1 Channel Intrinsically Safe Power Supply PCB Module (PS)
• II 1 G EEx ia IIB T4
• Output 5 Vdc, 160 mA, supplied by PSD1001C
• Zone 0 InstallaƟon
• Module for PCB MounƟng
• 500 V input/output isolaƟon
• Width 55 mm, Depth 30 mm, Height 15 mm
PSD1004
Intrinsically Safe Power Supply (PS)
• II 1 G EEx ia IIB T4
• Output 5 Vdc, 160 mA
• Supplied by PSD1001C
• Zone 0 InstallaƟon
• 500 V input/output isolaƟon
PSD5201
SIL 3 1 Channel Intrinsically Safe Power Supply (PS)
• II 3 (1) G Ex nA [ia Ga] IIB T4 Gc;
II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I
• 1 Output 14.5 V - 160 mA
• Input from Zone 0 / Div. 1
• Zone 2 / Div. 2 installaƟon
PSW1250
SIL 2 / SIL 3 Universal Input Power Supply
24 Vdc, 50 A, Zone 2 / DIV. 2 InstallaƟon Suitable for Parallel OperaƟons
• Supply 90 - 265 Vac
• Output 24 Vdc, 50 A; regulated and adjustable from 21 to 28 Vdc.
• Eĸcency beƩer than 94% at 220 Vac supply
• Two or more Units can be paralleled for Redundancy or addiƟonal
power with automaƟc load sharing
• Remote indicaƟon for Power Failure
• Zone 2 / Div. 2 installaƟon
• ATEX Category 3 for Zone 2;
II 3 G Ex nA nC IIC T3 Gc;
IECEx Ex nA nC T3 Gc
• Three over-voltage redundant protecƟons
• Reduces Power dissipaƟon by replacing a SchoƩky diode with
Mosfet AcƟve Ideal Diode
• Wall or DIN-Rail mounƟng
• Two Units in parallel oīer AC1 or AC2 redundancy
• Power Factor correcƟon
• High load fuse breaking capability without interrupƟng operaƟons
70 www.AutoSystem.ir www.gmintsrl.com
PÊóÙ SçÖÖ½®Ý
PSW1230
SIL 2 / SIL 3 Universal Input Power Supply
24 Vdc, 30 A Zone 2 / DIV. 2 InstallaƟon Suitable for Parallel OperaƟons
• Supply 90 - 265 Vac
• Output 24 Vdc, 30 A; regulated and adjustable from 21 to 28 Vdc
• Eĸcency beƩer than 94% at 220 Vac supply
• Two or more Units can be paralleled for Redundancy or addiƟonal power
with automaƟc load sharing
• Remote indicaƟon for Power Failure
• Zone 2 / Div. 2 installaƟon
• ATEX Category 3 for Zone 2;
II 3 G Ex nA nC IIC T3 Gc;
IECEx Ex nA nC T3 Gc
• Three over voltage redundant protecƟons
• Reduces Power dissipaƟon by replacing a SchoƩky diode with Mosfet
AcƟve Ideal Diode
• Wall or DIN-Rail mounƟng
• Two Units in parallel oīer AC1 or AC2 redundancy
• Power factor correcƟon
• High load fuse breaking capability without interrupƟng operaƟons
N
AC 2 L
FLT AC FLT AC
PSW1230 PSW1230
- + - +
Load Sharing
+
DC 1 24 Vdc, 30 A + 30 A
-
PSS1250
SIL 3 Power Supply System Universal Input,
24 Vdc, 50-100-150 A, Zone 2 / DIV. 2 InstallaƟon
• Supply 90 - 265 Vac
• Output 24 Vdc, 50 A; regulated and adjustable from 21 to 28 Vdc.
• Eĸcency beƩer than 94% at 220 Vac supply
• Two or more Units can be paralleled for Redundancy or addiƟonal power
with automaƟc load sharing
• Remote indicaƟon for Power Failure
• Zone 2 / Div. 2 installaƟon
• ATEX Category 3 for Zone 2;
II 3 G Ex nA nC IIC T3 Gc;
IECEx Ex nA nC T3 Gc
• Three over voltage redundant protecƟons
• Reduces Power dissipaƟon by replacing a SchoƩky diode with Mosfet AcƟve Ideal Diode
• Wall or DIN-Rail mounƟng
• Two Units in parallel oīer AC1 or AC2 redundancy
• Power factor correcƟon
• High load fuse breaking capability without interrupƟng operaƟons
• Hot swappable modules
Notes
Power Supply Systems can be ordered with:
• 19” or 9” Rack enclosure.
• Hot Swapping (HS) capability or not.
• DiagnosƟc Module (PSO1250) or not.
• 16 diīerent conĮguraƟons (see data sheet DTS0412)
9”Rack Enclosure
19”Rack Enclosure
72 www.AutoSystem.ir www.gmintsrl.com
PÊóÙ SçÖÖ½®Ý SùÝãÃÝ
74 www.AutoSystem.ir www.gmintsrl.com
PÊóÙ SçÖÖ½®Ý - S½ã®ÊÄ T½
Ch. SIL
Model Hazardous Area Output Supply
per unit level
24 V, 500 mA 95-264 Vac
PSD1000 Zone 2 / Div. 2 to power 1 115-350 -
D1000 Series Modules Vdc
21.5 - 30 SIL
PSD5201 Zone 2 / Div. 2 14.5 V, 150 mA 1
Vdc 3
SIL2
PSW1230 Zone 2 / Div. 2 24 V, 30 A 1 95-264 Vac /
SIL3
SIL2
PSW1250 Zone 2 / Div. 2 24 V, 50 A 1 95-264 Vac /
SIL3
24 V, 50-100-150 A SIL
PSS1250 Zone 2 / Div. 2 up to 6 95-264 Vac
Redundant 3
T3000
ÝÙ®Ý
4 ½ DIGIT LOOP INDICATOR
INSTALLATION IN ZONE 0
76 www.AutoSystem.ir www.gmintsrl.com
T3010 SÙ®Ý
T3010
4 ½ Digit Loop Powered Indicator
T3010S oīers process variable reading in Hazardous Area.
It is a loop powered 4-20 mA unit with less than 1 V voltage
drop and monitors 4-20 mA current, 0-100 % percentage
MounƟng opƟons
Figure A
Figure B
78 www.AutoSystem.ir www.gmintsrl.com
UÄÙÝãĮĦ HþÙÊçÝ LÊã®ÊÄ
80 www.AutoSystem.ir www.gmintsrl.com
UÄÙÝãĮĦ HþÙÊçÝ LÊã®ÊÄ
IgniƟon Triangle
From a chemical point of view, oxidaƟon, combusƟon and explosion
are all exothermic reacƟons with diīerent reacƟon speeds. For
such reacƟons to take place, it is essenƟal that the following three
components be present simultaneously in due proporƟons: Fuel,
Oxidizer, Energy
IEC 61508-61511
FACTS AND FORMULAE
IEC 61508 and IEC 61511 standards represent
a milestone in the progress of industry in
the achievement of supreme levels of safety
through the enƟre instrumented system
lifecycle.
The beneĮts of these new standards include
details and a greater eīecƟveness for what
concerns:
• the deĮniƟon of risk reducƟon and related
requirements;
• system design and implementaƟon;
• documentaƟon management;
• safety assessment and validaƟon;
• plant maintenance;
• cost management.
82 www.AutoSystem.ir www.gmintsrl.com
UÄÙÝãĮĦ S¥ãù IÄã¦Ù®ãù Lò½Ý
SIL MANUAL
SAFETY INSTRUMENTED SYSTEMS
SAFETY
The experience in safety and electronics
INSTRUMENTED acquired during the years has lead us to
SYSTEMS
the wriƟng of a comprehensive manual on
IEC61508 and IEC 61511.
Plant Engineering and Maintenance
This eīort has already proven to be a great
according to IEC 61508 and IEC 61511 Standards