Condition Monitoring OPAL

Format No. F/MECS/015_Rev00

Condition Monitoring Report

Dapartment: - CPP
Report Date: - 29/02/2019
Equipment Name: UB-1-AC SCANNER FAN

Last Measurement Deviation Report


*********************************

Database: OPaL- Dahej.rbm


Area: UB (UTILITY BOILER)
Report Date: 29-Feb-20 09:54

Reference Value is the PREVIOUS DATA

POINT POINT CURRENT REF ABS. % ALR


ID DESCRIPTION VALUE VALUE UNITS DELTA DEV. SYM
----- ----------------------------- ------- ----- ------- ------- ---- ---

46LM-MO-3A - UB-1-Scanner fan AC (28-Feb-20) PARM = OVERALL


M1H=Motor Outboard Horizontal 2.998 3.926 mm/Sec -.928 -24 #
M1P=Motor Outboard Horz Peakvue 1.101 .789 G-s .312 40
M1V=Motor Outboard Vertical 3.461 3.430 mm/Sec .031 1 +#
M1A=Motor Outboard Axial 5.356 6.751 mm/Sec -1.395 -21 #
M2H=Motor Inboard Horizontal 3.323 4.474 mm/Sec -1.151 -26 #
M2P=Motor Inboard Horz Peakvue .543 1.050 G-s -.508 -48
M2V=Motor Inboard Vertical 4.427 5.218 mm/Sec -.792 -15 #
M2A=Motor Inboard Axial 4.732 4.525 mm/Sec .207 5 +#
F1H=Fan Inboard Horizontal 5.316 5.708 mm/Sec -.392 -7 #
F1P=Fan Inboard Horz Peakvue 2.294 3.055 G-s -.762 -25
F1V=Fan Inboard Vertical 7.146 7.878 mm/Sec -.732 -9 #
F1A=Fan Inboard Axial 7.293 7.909 mm/Sec -.616 -8 #
F2H=Fan Outboard Horizontal 6.255 7.773 mm/Sec -1.518 -20 #
F2P=Fan Outboard Horz Peakvue 8.227 6.310 G-s 1.917 30
F2V=Fan Outboard Vertical 9.766 9.667 mm/Sec .099 1 +#
F2A=Fan Outboard Axial 9.226 10.43 mm/Sec -1.205 -12 #

HEALTH STATUS: ALARM

Observations & Analysis


➢ The overall health condition of the equipment is in ALARM zone as per ISO 10816
standards.
➢ Spectrum analysis revels non-synchronous bearings fault frequencies were
observed at fan bearings.

Suggested Action Plans:

➢ Replace the fan bearings.


➢ Inspect the coupling condition for inaccuracies, Achieve the precision alignment
between Motor and Fan.