Option Suffix Code PARAMETER Table

NOVA 300 SERIES AT GROUP


Option Suffix Code Description Available Model Remark
DIGITAL CONTROLLER /RET Retransmission ALL *note1 Symbol Parameter Setting Range Unit Initial Remark
ST390/380/370/360/340/320 /RS RS 485 ALL *note1 AT Auto Tuning OFF, ON ABS OFF AUTO Operation
AT.BS Auto Tuning Bias EUS(-10.0 ~ 10.0%) EUS EUS(0.0%) Always
Instruction Manual /HBA Heater Break Alarm Except ST320 *note1, *note3
◎ AT GROUP is skipped in ON/OFF MODE operation.
/ALM2 RELAY Output 1 Point Only ST320 *note2, *note4
Thank you for purchasing Samwontech production. Please use after read instruction manual /ALM3 RELAY Output 1 Point ST390 / ST370 SUB GROUP
for safety. Free to contact to our sales Div. for Production Inquiry and After Service.
/ALM4 RELAY Output 1 Point ST390 / ST370 *note1
Tel : +82-32-326-9120 FAX : +82-32-326-9119 Symbol Parameter Setting Range Unit Initial Remark
http://www.samwontech.com E-mail : webmaster@samwontech.com *note1 : RET, RS, HBA, ALM4 to be purchased separately A/M AUTO, MAN AUTO, MAN ABS AUTO Always
*note2 : RET, ALM2 to be purchased separately US1 User Screen OFF, D-Register Number(1~1299) ABS OFF Always
Safety Guide
US2 User Screen OFF, D-Register Number(1~1299) ABS OFF Always
*note3 : It can’t install with AOUT
The following safety symblos are used in this manual. OFF(0),
*note4 : It’s standard function except ST320 U.SLP Up Slop EUS(0.0%+1digit ~ 100.0%)/min EUS OFF(0) Always
! If this symbol is marked on the product, the operator must investigate the
OFF(0),
CAUTION explanation given in this manual to protect injury or death to personnel or Ex) Order Suffix Code : ST340 S0 / RS D.SLP Down Slop EUS(0.0%+1digit ~ 100.0%)/min EUS OFF(0) Always
damage to instrument.
When select
1. Be sure to operate the controller installed on a panel to prevent electric shock. SKDV Soak Deviation EUS(0.0 ~ 10.0%) EUS EUS(0.0%)
! Base + Option ALM=SOAK
2. Keep the input circuit wiring as far as possible away from power and ground Set Point
CAUTION circuit. SPRH EU(0.0 ~ 100.0%) EU EU(100.0%) Always
Range High
3. Do not mount front panel facing downward. Specification Set Point
4. To prevent electric shock, be sure to turn off and the source circuit breaker SPRL EU(0.0 ~ 100.0%) EU EU(0.0%) Always
Range Low
before wiring. ● PV/SP Data Dispaly : each 4 digits ● Sampling Time : 250ms
5. The power consumptions are 100-240VAC, 50/60Hz, 10VAmax and operate P.I.D GROUP
● Indication Acuracy : ±0.2% of FS ● Running Mode : AUTO / MAN
without power switching in advance. ● Control Loops and Mode : Single-Loop Control Setting Range
Symbol Parameter Unit Initial Remark
6. No work in wet hands( it caused electric shock ) ● Number of Setpoint(SP) : 1SP(1 Zone PID) Anti-Reset
7. Refer the way of grounding connection, however, keep away for grounding to ARW Auto(0.0) ~ 200.0% % 100.0% Always
● Retransmission Output : 4 ~ 20mADC ( PV, SP, MV ) or Loop power supply Wind-Up Select
Gas pipe, water pipe, lightening rod etc. C.MOD Control Mode D.DV, D.PV ABS D.PV Always
8. No magnetic disturbances are caused. ● Communication Protocols : PC-Link, MODBUS(ASCII, RTU), SYNC Master, Slave
● Power Supply and Consumption : 100 ~ 240VAC, 50 ~ 60Hz / Max 6W below FUZY Fuzzy OFF, ON ABS ON Always
Control Keys and Display AT-G AT Gain 0.1 ~ 10.0 ABS 1.0 AUTO Operation
Sensor ● PV Input : Universal Input(1 Point)
● Type of Input P Proportional Band 0.0 ~ 999.9% % 10.0% Always
Lights on when T/C : K, J, E, T, R, B, S, L, N, U, W, Platinel Ⅱ I Integral Time OFF, 1 ~ 6000 sec sec 120 sec Always
Manual Mode RTD : Pt100, JPt100 D Derivative Time OFF, 1 ~ 6000 sec sec 30 sec Always
operates. or, LED DCV : -10 ~ 20mV, 0 ~ 100mV, 0.4 ~ 2.0VDC, 1 ~ 5VDC, 0 ~ 10VDC MR Manual Reset -5.0 ~ 105.0% % 50.0% I=0
blinking during
(4 ~ 20mA, 0 ~ 20mA, with external 250Ω, 500Ω) ◎ P.I.D GROUP is skipped in ON/OFF MODE operation.
AUTO-TUNING
process. Output ● Control Output : 1 Point
Lights on CTL GROUP
● Time-proportional PID : Relay, SSR(V-Pulse)
during
Lights on when Continuous PID : SCR(4 ~ 20mADC) Symbol Parameter Setting Range Unit Initial Remark
EVENT
Control Output occur ● Alarm Capacity : STD 2 Points, Max 4 Points *note5 LOCK Key Lock OFF, ON(No Editing) ABS OFF Always
occurs Alarm
- Used in switching (fixed ALM) ● Alarm Type : 21 types(High/Low Temp Limit, Deviation Limit etc) *note6 Display High EU(-5.0 ~ 105.0%) :
DSP.H However, DSP.L<DSP.H EU EU(105.0%) Always
between parameters or HBA ● CT Spec : use CTL-6-S or 800:1 CT Limit
registering parameter Display Low EU(-5.0 ~ 105.0%) :
DSP.L However, DSP.L<DSP.H EU EU(-5.0%) Always
settings. Limit
*note5 : ST320 - STD 1 Point / ST320, 340, 360, 380 - Max 2 Points
- Pressing SET/ENT Key U.PWD User Password 0 ~ 9999 ABS 0 Always
*note6 : In case of HBA Option - 22 Types
at least 3 sec. switches ONOF ON/OFF MODE OFF, ON ABS OFF Always
between an operating Used when - Used to change the value of Safety & EMC Parameter
INIT OFF, ON ABS OFF Always
display and an operating shifting position parameters. Initialization
parameter setting display to modify value - Used to move between GROUP ● Safety : EN61010-1, UL61010C-1, CAN/CSA·C22.2 No.10101-92, Category Ⅱ IN GROUP
● EMC : EMI(Emission) - EN61326, ClassA
Symbol Parameter Setting Range Unit Initial Remark
Type of Input Sensor EMS(Immunity) - EN61326
IN-T Input Type refer to “Type of Input Sensor ” ABS TC.K1 Always
display range : -5% 105%
IN-U Display Range ℃, ℉ ABS ℃ T/C, RTD
Max. Value of
No. TYPE Temp.Range(℃) Temp.Range(°F) Group DISP IN.RH Measurement Range refer to “Type of Input Sensor” EU EU(100%) Always
Type of Alarm IN.RL Min. Value of However, INRH > INRL EU EU(0.0%) Always
-200∼1370 -300∼2500 TC.K1 Measurement Range
1 K1
Output Output Decimal Point
Standby Display Standby Display IN.DP 0~3 ABS 1 mV, V
K2 -199.9∼999.9 0∼2300 TC.K2 No. Type Direct No. Type Direct Position
2 Max Value
Data Data Within -1999∼9999
For Rev Off On For Rev Off On IN.SH 100.0 mV, V
of Input Scale however, INSH > INSL
3 J -199.9∼999.9 -300∼2300 TC.J Absolute-Value Absolute-Value
Min Value ABS
1 ○ ○ AH.F 11 ○ ○ AH.FS The Decimal Point Position is relay on
Upper-Limit Alarm Upper-Limit Alarm IN.SL the value of IN.DP
0.0 mV, V
2 Absolute-Value
○ ○ AL.F 12 Absolute-Value
○ ○ AL.FS of Input Scale
4 E -199.9∼999.9 -300∼1800 TC.E Lower-Limit Alarm Lower-Limit Alarm
IN.FL PV Filter OFF, 1 ~ 120 sec OFF Always
Upper-Limit Alarm Upper-Limit Alarm
3 of Deviation
○ ○ DH.F 13 of Deviation ○ ○ DH.FS UP
5 T -199.9∼400.0 -300∼750 TC.T Lower-Limit Alarm Lower-Limit Alarm BSL BOUT SEL OFF, UP, DOWN ABS (DCV=OFF) Always
4 of Deviation
○ ○ DL.F 14 of Deviation
○ ○ DL.FS
Upper-Limit Alarm Upper-Limit Alarm BS Bias Value EUS(-100.0 ~ 100.0%) ABS 0 Always
6 R 0∼1700 32∼3100 TC.R 5 of Deviation
○ ○ DH.R 15 of Deviation
○ ○ DH.RS
Lower-Limit Alarm Lower-Limit Alarm RSL RJC SEL TC, TC.RJ, RJC ABS TC.RJ T/C
6 of Deviation
○ ○ DL.R 16 of Deviation
○ ○ DL.RS
7 B 0∼1800 32∼3300 T/C TC.B OUT GROUP
Upper-and-Lower- Upper-and-Lower-
7 Limit alarm of ○ ○ DO.F 17 Limit alarm of ○ ○ DO.FS
8 S 0∼1700 32∼3100 TC.S Deviation Deviation
Symbol Parameter Setting Range Unit Initial Remark
Upper-and-Lower- Upper-and-Lower- Reverse and
TC.L 8 Limit Range of ○ ○ DI.F 18 Limit Range of ○ ○ DI.FS O.ACT REV, FWD ABS REV Always
9 L -199.9∼900.0 -300∼1600 Deviation Deviation Forward
Absolute-Value Absolute-Value
1 ~ 300 sec 2 sec Output=
9 ○ ○ AH.R 19 ○ ○ AH.RS CT Cycle Time sec SSR,RLY
10 N -200∼1300 -300∼2400 TC.N Upper-Limit Alarm Upper-Limit Alarm
Absolute-Value Absolute-Value
10 ○ ○ AL.R 20 ○ ○ AL.RS High-Limit value OL + 1Digit ~ 105.0% Always(ON/OFF
Lower-Limit Alarm Lower-Limit Alarm OH of Output (However, OH>OL) % 100.0% Mode: SKIP)
11 U -199.9∼400.0 -300∼750 TC.U 21 Soak ○ Soak 22 Lower-Limit Alarm
○ HBA
of HBA * Low-Limit value -5.0% ~ OH - 1Digit Always(ON/OFF
OL of Output (However, OH>OL) % 0.0% Mode: SKIP)
12 W 0∼2300 32∼4200 TC.W * In case of HBA Option
HYSTERISYS
HYS.H EUS(0.0 ~ 10.0%) EUS EUS(0.5%) ON/OFF Mode
Platinel Ⅱ 0∼1390 32∼2500 TC.PL HIGH
13 HYSTERISYS
Alarm Operation HYS.L EUS(0.0 ~ 10.0%) EUS EUS(0.5%) ON/OFF Mode
LOW
14 PtA -199.9∼850.0 -300∼1560 PTA
ON▶ ON▶ PO Preset Output -5.0 ~ 105.0% % 0.0% Always
Absolute- Upper-
15 PtB -199.9∼500.0 -199.9∼999.9 PTB Value DB Limit Alarm DB ALARM GROUP
Upper- of DEV
16 PtC -150.0∼150.0 -199.9∼300.0 RTD PTC Limit Alarm
PV ▲ Deviation - △ ▲ + Symbol Parameter Setting Range Unit Initial Remark
◀OFF ALM SP ◀OFF ALM.H ALT1 Alarm Type 1 refer to “Type of Alarm” ABS AH.F Always
17 JPtA -199.9∼500.0 -199.9∼999.9 JPTA Set value of Not Deviation
◀ON ◀ON AL-1 EU(-100.0 ~ 100.0%) EU EU(100.0%)
Absolute- Lower- ALT1 Alarm
18 JPtB -150.0∼150.0 -199.9∼300.0 JPTB Value DB Limit Alarm DB Upper-Limit Set Deviation
Lower- of DEV AL1.H EUS(-100.0 ~ 100.0%) EUS EUS(0.0%)
PV value of ALT1 Operation
0.4∼2.0V 0.400∼2.000V 2V Limit Alarm ▲ Deviation - △ ▲ + Low-Limit Set Deviation
19 ALM OFF▶ SP ALM.L OFF▶ AL1.L EUS(-100.0 ~ 100.0%) EUS EUS(0.0%)
value of ALT1 Operation
20 1∼5V 1∼5V DCV 5V Upper-and- ◀ON ON▶ A1DB Alarm 1 Hys EUS(0.0 ~ 100.0%) EUS EUS(0.5%) Always
Lower- DB DB Alarm 1 Operation 0.00~99.59(MM.SS)
A1DY ALT1-HH:MM in case of Soak TIME 0.00 Always
21 0∼10V 0∼10V 10V Limit alarm DEV=0 Delay Time
of
DEV
- ▲ ▲ + ALT2 Alarm Type 2 refer to “Type of Alarm” ABS AH.F Always
-10∼20mV -10∼20mV 20M Deviation OFF▶ △ ◀OFF
22 ALM.L ALM.H Set value of Not Deviation
AL-2 EU(-100.0 ~ 100.0%) EU EU(100.0%)
mV ALT2 Alarm
23 0∼100mV 0∼100mV 100M Upper-and- ON▶ ◀ON Upper-Limit Set Deviation
Lower- AL2.H EUS(-100.0 ~ 100.0%) EUS EUS(0.0%)
DB DB value of ALT2 Operation
Limit DEV DEV=0 Low-Limit Set Deviation
Range of AL2.L EUS(-100.0 ~ 100.0%) EUS EUS(0.0%)
- ▲ △ ▲ + value of ALT2 Operation
Base Suffix Code Deviation ◀OFF ALM.L ALM.H OFF▶
A2DB Alarm 2 Hys EUS(0.0 ~ 100.0%) EUS EUS(0.5%) Always
◀ON Alarm 2 Operation 0.00~99.59(MM.SS)
Model Base Suffix Code Description Lower- A2DY Delay Time ALT2-HH:MM in case of Soak TIME 0.00 Always
Limit DB
ST320 / 340 / 360 / 370 / 380 / 390 - Digital Controller ALT3 Alarm Type 3 refer to “Type of Alarm” ABS AH.F Option
Alarm of HBCD
Set value of
S SSR HBA ▲ AL-3 EU(-100.0 ~ 100.0%) EU EU(100.0%) Option
OFF▶ ALT3
Control Output A AOUT(SCR) ALM(HBCS) Upper-Limit Set
AL3.H EUS(-100.0 ~ 100.0%) EUS EUS(0.0%) Option
R RELAY U.SLP Operation D.SLP Operation value of ALT3
◀ON Low-Limit Set
0 100 ~ 240V AC ON▶ AL3.L EUS(-100.0 ~ 100.0%) EUS EUS(0.0%) Option
Power PV PV value of ALT3
1 24V DC(preparing) SKDV SKDV EUS(0.0 ~ 100.0%)
SOAK A3DB Alarm 3 Hys EUS EUS(0.5%) Option
Alarm 3 Operation 0.00~99.59(MM.SS)
A3DY ALT3-HH:MM in case of Soak TIME 0.00 Option
◀OFF NSP TSP TSP NSP OFF▶ Delay Time
Parameter Map ALT4 Alarm Type 4 refer to “Type of Alarm” ABS AH.F Option
ON state : ALM OFF in case of change SP.
Set value of
AL-4 EU(-100.0 ~ 100.0%) EU EU(100.0%) Option
ALT4
Power ON Upper-Limit Set
AL4.H EUS(-100.0 ~ 100.0%) EUS EUS(0.0%) Option
value of ALT4
Operation MENU Display Low-Limit Set
AL4.L EUS(-100.0 ~ 100.0%) EUS EUS(0.0%) Option
Display value of ALT4
▲▼ ▲▼ ▲▼ ▲▼ ▲▼ ▲▼ ▲▼ ▲▼ A4DB Alarm 4 Hys EUS(0.0 ~ 100.0%) EUS EUS(0.5%) Option
Operation G.AT G.SUB G.PID PWD G.CTL G.IN G.OUT G.ALM G.HBA G.RET G.COM Alarm 4 Operation 0.00~99.59(MM.SS)
PV Value A4DY ALT4-HH:MM in case of Soak TIME 0.00 Option
Display-1 : Initial Delay Time
SP Value display after ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT
◎ ALM3,4=ST320, 340, 360, 380 : can’t use.
ENT power on AT A/M ARW LOCK IN-T O.ACT ALT1 HBCS RET COM.P
HBA GROUP
Operation AT.BS US1 C.MOD DSP.H IN-U CT AL-1 HBCD RETH BAUD
PV Value Display-2 : US2 FUZY DSP.L IN.RH OH AL1.H HBDB RETL PRTY Symbol Parameter Setting Range Unit Initial Remark
OUT Value Output Control Heater Break
U.SLP AT-G U.PWD IN.RL OL AL1.L SBIT HBCS OFF, 1 ~ 50A ABS OFF Option
Display Current Set
ENT D.SLP P ONOF IN.DP HYS.H ** A1DB DLEN Heater Break
HBCD DISPLAY ONLY ABS INRH Option
SKDV I INIT IN.SH HYS.L ** A1DY ADDR Current Display
When User Heater Break
US.1 Screen is SPRH D IN.SL PO ALT2 RP.TM HBDB 0 ~ 10A ABS 1 Option
Current DB
registered SPRL MR IN.FL AL-2 RBS
* TRANS GROUP
ENT BSL AL2.H SPSL
When User BS AL2.L Symbol Parameter Setting Range Unit Initial Remark
US.2 Screen is RSL A2DB RET Select RET LPS, PV, SP, MV ABS PV Option
registered A2DY High-Limited Value of
INRH
RETH Retransmission T/C, RTD : INRH ~ INRL EU When select
ENT 3 sec or NO KEY 60 sec
ALT3 mV, V : INSH ~ INSL
RETL
Low-Limited Value of
However, RETH > RETL EU INRL RET=PV, SP
Retransmission
AL-3
AL3.H COMM GROUP
AL3.L
: OPTION Symbol Parameter Setting Range Unit Initial Remark
A3DB Communication PCC0, PCC1, MBSA
* : I=0 A3DY COM.P MBSR, Sync.M, Sync.S ABS PCC0 Option
Protocol
** : ON/OFF operation ALT4 BAUD Baud Rate 600, 1200, 2400. 4800, 9600, 19.2K ABS 9600 Option
AL-4 PRTY Parity None, Even, Odd ABS None Option
※ Operation in Power ON SBIT Stop Bit 1, 2 ABS 1 Option
AL4.H
- Start in Operation MODE DLEN Data Length 7,8(SKIP in MODBUS) ABS 8 Option
before Power OFF AL4.L
A4DB ADDR Address 1 ∼ 99(Max 31 can connect) ABS 1 Option
※ AUTO Operation MODE RP.TM Response Time 0 ~ 10(x10ms) ABS 0 Option
A4DY
- Start Control from PO ※ ST320 : ALM2 OPTION RBS Remote Bias EUS(-100.0~100.0%) EUS EUS(0.0%) Sync.S
SPSL SP SELECT LSP, RSP ABS LSP Option
Power Cable Connection RELAY Connection Communication Wiring (RS485)
NOVA300 NOVA300
■ Use Vinyl insulation wire 0.9~2.0㎟ (Allowed Rating Voltage Master Station Controller Controller
N 300V max) or higher leveled cable for power cable connection. RLY_NO
To protect electric shock, be sure to turn
L ! Be sure to keep L(Hot) and N(neutral) status connection.
! off the NOVA300 controller and the
COM CAUTION source circuit breaker before wiring. RTX+ RTX+ RTX+
CAUTION Otherwise, it may result for operation default and defect.
Terminating Terminating
NOVA300 RTX- RTX- RTX-

Φ5.8㎜ or less
Φ3.0㎜ or over Resistor Resistor
Terminal Specification
Use an Auxiliary RELAY
Use M3.5 screw-compatible crimp-on terminals with insulating SHIELD
sleeve as shown below.
■ When using an auxiliary relay or inductance load (L) such as solenoid, be sure to insert
Never touch the terminal in the rear panel to prevent electric shock when a CR filter(for AC) or diode (for DC) in parallel as a surge-suppressor circuit to reject
Class 3 Ground Class 3 Ground
power is supplied to the controller, and Be sure to turn off the electric sparks, preventing malfunction or damage.
! power before wiring. ■ Up to 31 slave controllers(NOVA300 series instruments equipped with communication
CAUTION Bind the wires connected to the controller terminals neatly together in ■ Recommended CR FILTER option) can be multidrop-connected.
order to prevent electromagnetic wave radiation. ▶ Seong Hoo Electronics : BSE104R120 25V (0.1μ+120Ω) ■ Be sure to connect terminating resistors(220Ω, 1/4W) to slave and master controllers
▶ HANA PARTS CO. : HN2EAC at communication-channel ends as shown above.
ANALOG INPUT Connection ▶ Songmi Electric Co.,Ltd. : CR UNIT 953, 955 etc ! To prevent electric shock, be sure to turn off the NOVA300 controller
▶ Jiwol Electric Co.,Ltd. : SKV, SKVB etc CAUTION and source circuit breaker before wiring.
1. RTD INPUT 2. DC VOLTAGE INPUT 3. DC CURRENT INPUT ▶ Shinyoug Communications Co.,Ltd. : CR-CFS, CR-U etc
SHIELD INPUT D-Registers
A SHIELD 1. In case of DC RELAY 2. In case of AC RELAY
INPUT SHIELD INPUT
External AC External AC Parameter D-egister Parameter D-egister Parameter D-egister
b + +
mV,V Power Power NPV 0001 AL-2 0407 IN.RL 0604
RTD DCmA R Master Master
B - - NSP 0002 AL-3 0408 IN.DP 0605
MVOUT 0006 AL-4 0409 BIAS 0606
NOVA300 NOVA300 NOVA300 ALSTS 0014 AL1.H 0411 IN.SH 0607
Class 3 Ground Class 3 Ground Class 3 Ground R R A/M 0105 AL2.H 0412 IN.SL 0608
DIODE CR FILTER AT 0121 AL3.H 0413 IN.FL 0609
AT-G 0122 AL4.H 0414 BSL 0610
ANALOG OUTPUT Connection US1 0135 AL1.L 0416 O.ACT 0611
US2 0136 AL2.L 0417 CT 0612
▪ DIODE, CR FILTER SP 0201 AL3.L 0418 OH 0613
1. SSR / SCR 2. RET Need to connect direct to RELAY COIL Terminal (SOCKET) LOCK 0203 AL4.L 0419 OL 0614
4∼20mADC,
! ▪ R : RELAY DSP.H 0204 A1DB 0421 HYS.H 0615
SHIELD 600Ω max CAUTION Rating Specification of RELAY COIL should be used lower than the Contact DSP.L 0205 A2DB 0422 HYS.L 0616
Rating of Controller U.PWD 0206 A3DB 0423 PO 0617
+ OUT1+ SHIELD ONOF 0207 A4DB 0424 RSL 0618
Actuator Receiver + INIT 0208 A1DY 0426 RET 0651
- OUT1- RET+
(Recorder Display Error and Correction SPRH 0211 A2DY 0427 RETH 0652
etc) - RET- SPRL 0212 A3DY 0428 RETL 0653
NOVA300
Class 3 Ground Display U.SLP 0216 A4DY 0429 COM.P 0661
NOVA300 ERROR Contents Correction D.SLP 0217 ARW 0501 BAUD 0662
SCR : 4∼20mADC, 600Ω max ERROR
Class 3 Ground SKDV 0218 FUZZY 0502 PRTY 0663
SSR : 12VDC min, 600Ω min E.SYS EEPROM, DATA Loss Ask repair HBCS 0301 P 0503 SBIT 0664
HBCD 0302 I 0504 DLEN 0665
E.RJC RJC SENSOR Failure Ask repair HBDB 0303 D 0505 ADDR 0666
To prevent electric shock, be sure to turn off the NOVA300 controller and the source circuit
! breaker before connection/disconnection of the actuator, receiver as well as wiring. Flash Decimal
Communication Failure
Comm Cable ALT1
ALT2
0401
0402
MR
C.MOD
0506
0507
RP.TM
RBS
0667
0668
point of SP CHECK
CAUTION ALT3 0403 IN-T 0601 SPSL 0669
S.OPN SENSOR Open SENSOR CHECK ALT4 0404 IN-U 0602
AL-1 0406 IN.RH 0603
PROCESS
Terminal Arrangement and External wiring E.AT AT Time Out (27h over) * Thick Line : READ ONLY
CHECK

ST390 ST370 ST340

RS485 HBA RET ALARM RS485 HBA RET ALARM RS485 HBA RET

RTX+ 21 21 + 21 21 ALM3 RTX+ 15 15 + 15 15 ALM3 RTX+ 11 11 + 11

RTX- 22 22 - 22 22 COM RTX- 16 16 - 16 16 COM RTX- 12 12 - 12

MAX: 19.2Kbps 4~20mA DC * Contact Rating MAX: 19.2Kbps 4~20mA DC * Contact Rating MAX: 19.2Kbps 4~20mA DC
250V AC 1A 250V AC 1A
/30V DC 1A /30V DC 1A

ALARM 11 21 1 TC INPUT mV/V INPUT RTD INPUT ALARM 8 15 1 TC INPUT mV/V INPUT RTD INPUT ALARM 6 11 1 TC INPUT mV/V INPUT RTD INPUT

11 ALM1
12 22 2 8 ALM1
9 16 2 6 ALM1
7 12 2
13 23 3 2 + 2 + 1 A 10 17 3 2 + 2 + 1 A 8 13 3 2 + 2 + 1 A
12 ALM2 14 24 4 2 b+ 9 ALM2 11 18 4 2 b+ 7 ALM2 9 14 4 2 b+
15 5 3 - 3 - 3 B-
12 5 3 - 3 - 3 B-
10 5 3 - 3 - 3 B-
13 COM 10 COM 8 COM

* Contact Rating * Contact Rating * Contact Rating


250V AC 1A 250V AC 1A 250V AC 1A
/30V DC 1A /30V DC 1A /30V DC 1A

OUT1 OUT1 OUT1


POWER SSR SCR RELAY POWER SSR SCR RELAY POWER SSR SCR RELAY

N HBA ALARM + 4 + 4 4 NO N HBA ALARM + 4 + 4 4 NO N HBA + 4 + 4 4 NO


14 11 9

15 L ALM3 12 L ALM3 10 L
23 23 - 5 - 5 5 COM 17 17 - 5 - 5 5 COM 13 - 5 - 5 5 COM
ALM4 ALM4

100~240V AC 24 24 COM Voltage 4~20mA DC * Contact Rating 100~240V AC 18 18 COM Voltage 4~20mA DC * Contact Rating 100~240V AC 14 Voltage 4~20mA DC * Contact Rating
(50/60Hz) Pulse 250V AC 1A (50/60Hz) Pulse 250V AC 1A (50/60Hz) Pulse 250V AC 1A
/30V DC 1A /30V DC 1A /30V DC 1A
* Contact Rating * Contact Rating
250V AC 1A 250V AC 1A
/30V DC 1A /30V DC 1A
※ HBA, RET to be purchased separately ※ HBA, RET to be purchased separately ※ HBA, RET to be purchased separately

ST360 ST380 OUT1 ST320


TC INPUT mV/V INPUT RTD INPUT SSR SCR RELAY RS485 TC INPUT mV/V INPUT RTD INPUT

2 + 2 + 1 A + 4 + 4 4 NO RTX+ 9 12 + 12 + 11 A
2 b+ 12 b+
3 - 3 -
1 2 3 4 5 - 5 - 5 5 COM RTX- 10 7 8 9 10 11 1213 13 - 13 -
3 B- 13 B-
21 22 23 24 RET ALARM 1 2 3 4 5 6
Voltage 4~20mA DC * Contact Rating MAX: 19.2Kbps
1112 13 14 15 Pulse 250V AC 1A + 7 7 ALM2
/30V DC 1A

- 8 8 COM
POWER OUT1 ALARM
RS485 HBA RET ALARM POWER HBA 4~20mA DC * Contact Rating SSR SCR RELAY
N 250V AC 1A 5 ALM1
11 ALM1 1 /30V DC 1A
RTX+ 21 21 + 21 N 23 + 3 + 3 3 NO
14 L
12 ALM2 2 6 COM
15 L
RTX- 22 22 - 22 24 - 4 - 4 4 COM
13 COM
100~240V AC * Contact Rating
MAX: 19.2Kbps 4~20mA DC * Contact Rating 100~240V AC (50/60Hz) Voltage 250V AC 1A
4~20mA DC * Contact Rating
250V AC 1A (50/60Hz) /30V DC 1A
Pulse 250V AC 1A
/30V DC 1A ※ HBA, RET to be purchased separately ※ ALM2, RET to be purchased separately /30V DC 1A

Dimension and Panel Cutout How to install Mount

ST390 ST380 ST370 ST360 ST340 ST320 ST390

ST370 ST360
A
C D
E
B

MOUNT BLOCK MOUNT BLOCK

PANEL PANEL
H +0.6
0

ST340

ST380
Panel Thickness G +0.6
0
1mm~10mm : 390,380,370,360
1mm~ 5mm : 340,320
PANEL
ST320
MODEL A B C D E F G H I J K
LATCH
ST390 96 96 11.4 99.6 120 120 92 92 96 4 92
K +0.6
0

ST380 48 96 11.4 99.6 70 120 45 92 48 3 92


ST370 72 72 11.4 99.6 90 90 68 68 71 3 68 PANEL

ST360 96 48 11.4 99.6 120 70 92 45 - - -


+2 LATCH
I*N-J 0 MOUNT BLOCK
ST340 48 48 11.0 99.6 70 70 45 45 48 3 45
N:the Number of unit PANEL
ST320 48 24 3.3 96.7 70 60 45 22.2 48 3 22.2 1) Cut the mounting panel. (Refer to Dimension and Panel Cutout)
2) Insert the controller into the panel cutout with the rear terminal board facing ahead.
3) Attach the right and left mount and fix it to the panel.(Use driver)