Firmware UBST
© Fronius International GmbH
Version 01/2014
Welding Technology
Fronius reserves all rights, in particular rights of reproduction, distribution and translation.
No part of this work may be reproduced in any way without the written consent of Fronius. It must not be saved, edited, reproduced or
distributed using any electrical or electronic system.
You are hereby reminded that the information published in this document, despite exercising the greatest of care in its preparation, is
subject to change and that neither the author nor Fronius can accept any legal liability.
Gender-specific wording refers equally to female and male form.
.
.............................................................................................................................................................................
Versionshistory 2/12
TABLE OF CONTENTS
Versionshistory 3/12
11 Changes from UBST1 V1.05.14 to V1.05.28 .............................................................................. 10
11.1 New functions ................................................................................................................................ 10
11.2 Fixed bugs ..................................................................................................................................... 11
.............................................................................................................................................................................
Versionshistory 4/12
1 CHANGES FROM UBST1 V1.07.56 TO V1.07.58
• Software configuration Automation – activation of arch sensors and mode CC/CV inserted
• Port 15002 has been expanded by wGasRealValueTagSystem
• Modbus UDP - Device Suberror inserted in the process image (0xF007
• Software configuration Daimler Integra inserted in AB Profibus DP
• Software configuration Daimler Integra inserted in AB Profibus DP
• Modbus UDP - Device Suberror has been inserted in the process image (0xF007
• Port 15002 has been expanded by wGasRealValueTagSystem
• In software configuration Daimler Integra the output signal ‘Welding simulation active’ was
deactivated
• Anybus-S General
o Anybus-Timeout has been reduced from 2000ms to 20ms
o Anybus-Timeout is now displayed by the flash code on L4, previously L1
• AB Profibus DP
o Actual value of arc length was not displayed in TIG
• AB Profinet IRT / FO
o Wrong index for writing of data in AB_SetSystemContactMibII
o Function AB_SetEthernetConfiguration is no longer invoked in ProfiNet (certification error)
.............................................................................................................................................................................
Versionshistory 5/12
o Function AB_SetEthernetConfiguration is invoked after a factory reset
o Endless loop fixed in (bLifeCycleTimeoutCounter > bLifeCycleTimeout)
o Upon disconnection of (boAnybusEthernetLink) the ports and tasks are no longer stopped
• Anybus-S
o since the Anybus timeout of 5 ms was too short, the error EIF 6.5 occurred at times of higher
network loads
• Anybus-S Ethernet
o Response of data is no longer evaluated upon AB_SendTo
• Etheretn/IP
o if no defined software configuration was found, FS CC/CV was always activated
• General
o Software enabling for arc sensors has been added - Device type 0x41 is selected.
With the software configurations ABB, Fanuc, RMS, Serimax und WeldCom, they are
automatically requested by the UST.
o Query ReadTag (UBST1_TAG_STATUS_FLAGS) is now possible via WIN_PC_PRG,
WINDOWS_PC und WINDOWS_PC2.
• Modbus UDP gateway
o New tag (ALS, Alt) have been added.
• EtherCAT
o EtherCAT has been implemented.
o Product info has been adapted to Fronius (separate Vendor ID and Product Code)
• ProfiNet
.............................................................................................................................................................................
Versionshistory 6/12
o During active communication with robot, the buttons "Change" and "UBST Factory" in the "IP
Setting" screen of the RCU 5000i are switched inactive.
• General
o Exceed of timeout during JobChange – operating system could crash (L5 does not flash
anymore and Error LED lights up.)
• Weldcom
o The registers were changed, but the message to LocalNet was not sent. It was only sent in
the course of the cyclical transfer.
• Modbus UDP gateway
o Upon entering the value 255, the subsequent bytes were also set to 255.
• General
o Ethernet factory settings can be loaded using RCU5000i
o Output of LN data to UDP port 15002
• Anybus DeviceNet Enterprise
o All limit signals added to byte 13
• Anybus Ethernet
o Station type, device identity and I&M information for ProfiNet IRT and IRT FO added
o Reading of MAC address for Anybus-S Ethernet
o If ProfiNet RT/IRT/IRT-FO is reset by the Master, the module is automatically re-initialised
o Improved performance during data updates following an LN_READTAG
o ProfiNet RT, IRT, IRT-FO MIB and MIB-II information added (MIB=Management Information
Base) IP address 0.0.0.0 and deletion of station name when manufacturer settings are being
loaded (not only in the case of Daimler Integra)
• VW/Audi group interface software configuration
o "In standby" signal added
o "In automatic" signal added
o "No maintenance warning" signal added (when replacing the contact tube and changing the
torch body)
o "Phase monitoring OK" signal added – must remain on for 10 cycles
o "Spray On" signal added
o "No maintenance warning" upgrade for power source, wire-feed unit and hosepack
o Phase error is only output if the bus is online
o Error 38 is output in the "No external stop" signal
o "No program available" signal added for TIG
o Cold-wire version added
o The job number is only returned when a job or program has been changed. If no change is
detected, the job number is returned after a 2 second timeout
• AB Ethernet/IP ABB software configuration
o New AB Ethernet/IP ABB software configuration added
• Daimler Integra group interface software configuration
o New AB ProfiNet Daimler Integra software configuration added
o "Main current" signal added
• PSA Autonomous job software configuration
o E06 "Power source ready" signal added to On Robot Autonomous job
o PSA Autonomous Fixed Torch job added
o E06 "Cleaning station in position down" signal added to Autonomous Fixed Torch job
o Service B is not cancelled if Service B authorisation is removed by the robot
.............................................................................................................................................................................
Versionshistory 7/12
• Modbus UDP gateway
o UST, UBST1 and SR versions output in the General Area
o The "Configuration" button is now always activated
o New day (HOST_TAG_TIG_STS2_MULTIPLICATOR) added
• Weldcom software configuration
o Part number added for Modbus UDP WeldCom gateway
o ROB I/O upgrade to output torch collision and current flowing
o Change to Beckhoff2Libo device type
• WebServer
• WebServer has been added
• General
o No LocalNet communication when booted with external supply voltage if the power source
was switched off and then switched on again
• Anybus Ethernet
o Also initialise IP settings in the case of ProfiNet RT/IRT/IRT FO
o IP settings can only be read from the Anybus-S Ethernet module while data is being
exchanged, i.e. when there is an online connection between the robot and the IO controller.
If they were always read, even when there is no online connection, the settings would
always be 0.0.0.0 and the Anybus-S Ethernet module would not be accessible
o If the Ethernet connection is interrupted, the power source is stopped
o ProfiNet RT, IRT, IRT-FO
o If Anybus-S ProfiNet was reset by the Master, EIF 6.2 (AB_ReadEthernetConfiguration) was
started, even though the module was no longer initialised
• PSA Autonomous job software configuration
o "Welding without parts" screen is now reset
o When a Force Request occurred, the Centralized Request was automatically started after
OK or Cancel, as the Service B authorisation from the robot was still present. There is now a
5 second delay before the Centralized Request is activated
o PSA Autonomous Fixed Torch job - If Service B was cancelled, torch cleaning stopped in the
current position. It now returns to its start position
• Modbus UDP gateway
o In the case of Modbus UDP, data is checked for changes in function 0x17 (Read/Write
Multiple Register) to reduce the load on the LocalNet
o In the case of Modbus, data is now checked for changes in functions 0x06 (Write Single
Register) and 0x10 (Write Multiple Register) to reduce the load on the LocalNet
• Bugfix Gateway Modbus UDP - Response in the case of TAG values sent with incorrect data
.............................................................................................................................................................................
Versionshistory 8/12
• Add on of Special Data (HOST_TAG_JOBCORR_JOBNUMBER,
HOST_TAG_JOBCORR_TIG_CURRENT, HOST_TAG_JOBCORR_TIG_CURRENT_MIN,
HOST_TAG_JOBCORR_TIG_CURRENT_MAX)
Versionshistory 9/12
• Extension to TAG system
• Modbus UDP gateway MotoFro enables: Gateway Level 1, Gateway Level 2
• AB Ethernet/IP Fanuc enabling: CC/CV, Gateway Level 1
• AB Ethernet/IP Serimax enables: Gateway Level 1, Gateway Level 2
• Modbus UDP gateway - Function 0x10 (Write Multiple Register) - Response is the wrong length
• Modbus UDP gateway - Function 0x10 (Write Multiple Register) - Incorrect address when there
are more than 4 tags
• Modbus UDP gateway - Function 0x03 (Read Holding Register) - Addition of
ConvertOutDataRoboEthernetFronius in Process Image Read
• Modbus UDP gateway - Streaming Data - incorrect data values were output with tag system
• The firewall IP address 3 was not checked for 0.0.0.0
• Even with a firewall IP address of xxx.xxx.xxx.255, access was always allowed
• Bugfix in AB Profibus Daimler Mettingen - QS signal vD and voltage mixed up
Versionshistory 10/12
• Dynamic log on/log off from the SR41-service for controling a non-Fronius wirefeeder: Activating
via process image Ethernet I/IP and ProfiNet IO Fronius
• Anybus Ethernet/IP with DeviceType arc-control
• Adjustment of process image at AB Ethernet/IP: Customer version RMS
• Expansion of the UbstConfigTool with Modbus-Port, Modbus-Firewall-IP, DeviceName,
NetName and Path Xplorer
• CC/CV mode on the power source is activated automatically with AB Ethernet/IP
• New Modbus-function 0x10 Write Multiple Register was insert
• Change to Gateway Level query. Gateway Modbus UDP only activated when Gateway Level 1 is
enabled.
• Only when Gateway Level 2 is enabled does the display show that Gateway Level 1 is missing
• Bugfix on Interbus 2MB, signals from Interbus to Rob I/O were overwritten during activation of
component number
.............................................................................................................................................................................
Versionshistory 11/12
13 CHANGES FROM UBST1 V1.04.26 TO V1.05.8
• Bugfix AB Profibus DP; now signal power source ready is also reset if no connection to the
Busmaster exists (error nummer 150)
• Bugfix AB Interbus 2MB Fronius Signal; now signal power source ready is also reset if no
connection to the Busmaster exists (error nummer 150)
.............................................................................................................................................................................