MT Standard Safety Sign Checklist For 132kV SS

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

Standard Safety Sign Checklist for 132/11kV SS

Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

No Parking

No Unauthorized entry

Wear Personal 
Protective Equipment
In front of 
1 Substation main 
gate / entrance 

No Smoking

Assembly Point (At the 
location of Assy. Pt.)

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Near Breaching  No Parking (outside)
2
inlet

Keep Clear n/a

Emergency Contact 
numbers (including 
DEWA emergency 
number)
3 Security Room

No Smoking
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Danger electric shock 
risk (on EDB)

Fire extinguisher (Cabinet)

Fire alarm call point

3 Security Room
First aid instructions for 
electric shock 

Exit Sign

Fire Action

Danger battery acid 

Danger flammable liquid 
(on diesel tank)

Wear ear protectors 
4 Fire pump room

No smoking 

Water flow directional arrow for 
fire water pipeline

Do not touch hot 
surfaces
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Instruction to shut off 
and operation of fire  n/a
pumps.

No naked light

Danger electric shock 
risk (on EDB)

Push bar to open  (for 
Fire Exit Door)

Fire extinguisher (Cabinet)
4 Fire pump room

Fire alarm call point

First aid instructions for 
electric shock 

Exit Sign

Fire Action

5 Fire water tank capacity to be marked
n/a

Transformer area 
6 ( 3IDT, 3 ET and 1  Danger high voltage
reactor)
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Transformer name plate

Fire extinguisher

(Cabinet)

Fire Action

Fire alarm call point

No smoking 
Transformer area 
6 ( 3IDT, 3 ET and 1 
reactor)
Use insulated tools (in 
the middle room of IDT 
& ET)

First aid instructions for 
electric shock 

Deluge system  Operation and resetting 
7
manifold area procedure
n/a
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Warning signs for the 
extinguishing agent 

Mandatory Sign(Door 
opening sequence)

Keep the door closed

operating instruction for  inside Cap. Bank. 
the manual release Room

8 Capacitor Bank

Danger ‐ high voltage

Fire Action

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Exit Sign

Push bar to open  (for 
Fire Exit Door)

Danger over head 
hazard
Cable Basement ( 
9
132 and 11 kV)
Wear Safety helmet 
(near all entrances to 
the basement )
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Wear Safety Shoes (at 
all basement entrance)

Danger Electrical 
Hazards (on EDB)

Fire extinguisher

“Fire exit, keep clear “ 

Fire Exit 

Use Hand Rail (cable 
basement staircase)

Cable Basement ( 
9
132 and 11 kV)

Fire alarm call point

Fire Action

Danger 132000 Volts 
(near 132kV Cables)

Danger 11000 Volts  
(near 11kV Cables)

Push Bar to Open
Photoluminescent 
directional arrow to fire 
exit
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

No smoking 

Fire Action

Fire alarm call point

Exit Sign

“Fire exit keep clear “ marking 
near manhole exit(Manhole  If "Do Not Store Materials" wriiten on 
cover need to be painted in  checquered plate, no signboard is required
photo luminescent paint)

11kV SWGr Room  First aid instructions for 
10 electric shock 
(1&2)

Danger electric shock 
risk (on EDB)

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Danger high voltage (on 
SG Panels)

Wear Safety helmet

Push bar to open (for 
Fire Exit Door)
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

11kV SWGr Room 
10 Fire extinguisher
(1&2)

Fire alarm call point

“Fire exit keep clear “ 
marking near manhole 
exit(Manhole cover need 
to be painted in photo 
luminescent paint)

No smoking 

Fire Action

11 132kV GIS

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Danger Electrical 
Hazards 

Danger  ‐ High Voltage

First aid instructions for 
electric shock 
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Fire extinguisher

Danger electric shock 
risk (on EDB)

Push bar to open  (for 
Fire Exit Door)
11 132kV GIS

Wear Safety helmet 

Exit Sign

Put the chain before 
leaving (at Crane 
Platform)

Emergency Contact 
numbers (including 
DEWA emergency 
number)

No smoking 
12 Corridor

Push bar to open  (for 
Fire Exit Door)

Fire alarm call point
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Fire Action

12 Corridor

Exit Sign

Fire extinguisher

Fire extinguisher

No smoking 
13 Record Room

Exit Sign

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Danger electric shock 
risk (on EDB)

14 LVAC Room

No smoking 
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Exit Sign

Fire extinguisher

Fire alarm call point
14 LVAC Room

Fire Action

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Fire extinguisher

Exit Sign

Do not climb on racks
15 Work Shop Room

No smoking 

Safe Working Load (to 
SWL
be written on shelf)
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Fire extinguisher
16 Store

Exit Sign

No smoking 

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Fire extinguisher

No smoking 

17 Telecom Room Fire Action (if Call Point 
Available)

Fire alarm call point (if 
Call Point Available)

Exit Sign

Danger electric shock 
risk (on EDB)
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Fire extinguisher

Exit Sign

No smoking 

Fire alarm call point

18 Control Room
Danger electric shock 
risk (on EDB) if available

First Aid Box

Identification no. for 
First Aid Box

First aid instructions for 
electric shock 

Exit Sign

Fire Action
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

No naked light

No smoking 

Wear Eye Protection

Wear gloves 

Battery Room 1 &  Emergency Eye Wash
19
2

Use insulated tools 

Danger Electrical 
Hazards

Danger battery acid 

Emergency Contact 
numbers (including 
DEWA emergency 
number)
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Exit Sign

Wear Protective 
Clothing

Danger electric shock 
risk 

Battery Room 1 & 
19
2
First aid instructions for 
electric shock 

Fire Action (if Call Point 
Available)

Fire extinguisher

No smoking 

Exit Sign

20 Charger Room

Danger electric shock 
risk (on EDB) if available
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Fire extinguisher

Emergency Contact 
numbers (including 
DEWA emergency 
number)

20 Charger Room

First aid instructions for 
electric shock 

Danger electric shock 
risk 

Fire Alarm Call Point

Pumps ( Transfer 
21
& Booster)

No smoking 
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration
Operating Instructions

Wear Respirator

No smoking 

Danger electric shock 
risk (on EDB) if available

Exit Sign

Push bar to open  (for 
22 Nitrogen Room
Fire Exit Door)

Fire extinguisher

Emergency Contact 
numbers (including 
DEWA emergency 
number)

Fire Action

First aid instructions for 
electric shock 
Standard Safety Sign Checklist for 132/11kV SS
Substation Name: Date:
Safety Sign
No. Location Y N Remarks
Description Illustration

Use Hand Rail

Step Down 

23 Stair case
Push

Pull

Exit Sign

Push bar to open  (for 
Fire Exit Door)

Fire Action

Roof Crane 
24 Area/Loading  Fire alarm call point
Platform

Exit Sign

Push bar to open  (for 
Fire Exit Door)

Inspected by: