The document provides technical specifications for various motor control center models from PARS TABLEAU including the N660, N680, N662, N663, N663C, N668-0, N668-0C, N668-1, N668-1C, N668-2, N668-2C, N683-B, N683-BS, N683-4B and N687 models. It lists details such as dimensions, installation type, ingress protection level, voltage ratings, short circuit ratings and other electrical characteristics. The motor control centers can be used for applications such as distribution and motor control and are designed to IEC standards for construction and safety.
The document provides technical specifications for various motor control center models from PARS TABLEAU including the N660, N680, N662, N663, N663C, N668-0, N668-0C, N668-1, N668-1C, N668-2, N668-2C, N683-B, N683-BS, N683-4B and N687 models. It lists details such as dimensions, installation type, ingress protection level, voltage ratings, short circuit ratings and other electrical characteristics. The motor control centers can be used for applications such as distribution and motor control and are designed to IEC standards for construction and safety.
The document provides technical specifications for various motor control center models from PARS TABLEAU including the N660, N680, N662, N663, N663C, N668-0, N668-0C, N668-1, N668-1C, N668-2, N668-2C, N683-B, N683-BS, N683-4B and N687 models. It lists details such as dimensions, installation type, ingress protection level, voltage ratings, short circuit ratings and other electrical characteristics. The motor control centers can be used for applications such as distribution and motor control and are designed to IEC standards for construction and safety.
PARS TABLEAU Technical Data [ Motor Control Center ] MCC
General characteristics N660 N680
Description N662 N663 N663C N668-0 N668-0C N668-1 N668-1C N668-2 N668-2C N683-B N683-BS N683-4B N687 N687-1P N687-2P Applications distribution distribution motor control motor control Refrence standards IEC 60439-1 IEC 60439-1 IEC 60529 IEC 60529 IEC 61641 IEC 61641 Installation indoor indoor Mechanical characteristics Cable entry top/bottom top/bottom Access rear front Protection Index (IP) UP TO 42 UP TO 42 Segregation Form 2b/3b/4a/4b Form 2b/3b/4a/4b height 2350-2550 2350-2550 2350-2550 2350-2550 2350-2550 2350-2550 2350-2550 2350-2550 2350-2550 2350 2350 2350 2350 2350 2350 width 380 480 670 580 770 810 1000 1160 1350 750 750 900 1100 1100 1350 depth 1000 1000 1000 1000-1350 1000-1350 1000-1350 1000-1350 1000-1350 1000-1350 600 600 600 600 1000 1000 Casing coating Epoxy-polyester powder Epoxy-polyester powder Frame Iron-phosphated steel plate Iron-phosphated steel plate Casing color RAL7032 RAL7032 Electrical characteristics Rated insulation voltage (Ui) 1000V AC 1000V AC Rated service voltage (Ue) 690V AC 690V AC Rated frequency (F) 50/60Hz 50/60Hz Rated impulse withstand voltage (Uimp) 12KV 12KV Rated auxiliary circuit voltage 230 V AC max. 230 V AC max. overvoltage category IV IV Pollution index 3 3 Rated current (In) UP TO 6000A UP TO 4000A Horizontal busbar rating UP TO 6000A UP TO 4000A Vertical busbar rating 1600A UP TO 6000A 1600A UP TO 6000A Poles 3 or 4 pols 3 or 4 pols Horizontal busbars Rated short time withstand current (Icw) 1s 100KA 100KA Rated peak withstand current 220KA 220A Vertical busbars Rated short time withstand current (Icw) 1s 70KA 70KA Rated peak current Rated peak withstand current 160KA 160KA Internal arcing personal protection IEC 61641 65KA 0.5s 65KA 0.5s Earthing arrangment TT-IT-TNS-TNC TT-IT-TNS-TNC Motor control feeder limits up to 250 KW up to 250 KW