measuring

Electromagnetic •

Flowmeter compact monitoring



for conductivity liquids analysing

MIK

OORange from liquids, acids and


caustic solutions:
0.01-0.5 … 35-700 l/min
MIK with OO Accuracy: ±2.0 % of full scale
frequency-, switching-, analogue output
OO pmax: 10 bar; tmax: 80 °C
OOConnection: G½ ... G 2¾ male,
diverse accessories
OOMaterial:
normal liquids: PPS, stainless steel
aggressive liquids:
PVDF, Hastelloy® or Tantalum
OOAdvantage:

S5
· no moving parts in the measuring tube
· low pressure loss
· any mounting position
· short reaction time – replacement
for calorimetric flow switch
MIK with · high quality for lowest price
digital plug on display

MIK with MIK with


dosing electronic compact electronic

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, D-65719 Hofheim/Ts.
GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, Head Office:
NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SPAIN, SWITZERLAND, +49(0)6192 299-0
+49(0)6192 23398
THAILAND, TUNISIA, turkey, USA, VIETNAM info.de@kobold.com
1/10 - 2018

www.kobold.com

1
Electromagnetic Flowmeter Compact Model MIK

Description Technical Details


The new KOBOLD flow meter Type MIK is used for measuring Range: see table
and monitoring smaller and medium-sized flow of conductivity Accuracy: ±2.0 % of full scale
liquids in pipes. Repeat accuracy: ±1.0 % of full scale
The device operates according to the electromagnetic Measurement process: electromagnetic
measurement principle. According to Faraday’s Law of Electrical conductivity: min. 30 μS /cm (at MIK- ...08 and
magnetic induction a voltage is induced in a conductor moving 10: min. 200 μS /cm)
through a magnetic field. The electrically conductive measuring
Mounting position: in all directions,
agent acts as the moved conductor. The voltage induced in
flow in direction of the arrow
the measuring agent is proportional to the flow velocity and
is therefore a value for the volumetric flow. The flowing media In-/Outlet: 3 x DN / 2 x DN
must have a minimum conductivity. The induced voltage is Media temperature: -20 ... +80 °C (max. +60 °C
picked up by two sensing electrodes which are in contact with PVC-connection set)
with the measuring agent and sent to the measuring amplifier. Ambient temperature: -10 ... +60 °C
The flow rate will be calculated based on the cross sectional Max. pressure: 10 bar
area of the pipe.
Max. pressure loss: max. 250 mbar at full scale
The measurement is not depending on the process liquid
Max. medium viscosity: 20 cSt ≤ G1;
and its material properties such as density, viscosity and
70 cSt ≥ G1½
temperature. The device may be equipped with a switch,
frequency or analogue output. Moreover, there is a compact Wetted Parts
electronic system to be selected from, which contains a Sensor housing: PPS or PVDF, fibreglass-reinforced
switch and an analogue output. Connection set: PVC-glue connection or hose
The device series is completed by an optionally obtainable connection, weld-on ends
dosing and counter electronic system. The counter stainless steel 1.4404
electronics system shows the current flow rate on the first Electrodes: stainless steel 1.4404,
line of the display and shows the partial or overall volume on Hastelloy® C4 or Tantalum
the second line. A dosing electronic system controls simple Seal: NBR, FPM or FFKM
filling duties and also measures the flow rate, overall volume
Response time t90: approximately 1 s (at flow
and filling volume. The analogue output and two relay outputs
changes >10% FS)
can be utilised for the further processing of signals.
Protection: IP 65

Media
OO Electric conductivity liquids Connection/Ranges
OO Acids and caustic solutions
Connection Inside Flow velocity Range
OO Drinking, cooling and waste water diameter at full scale
OO Ground water, raw water
OO Aggressive or salty solution approx. 0.45 m/s 10 ... 500 ml/min
OO Unsuitable for oil (missing conductivity) G ½ male 5 mm approx. 0.9 m/s 0.05 ... 1.0 l/min
approx. 2.7 m/s 0.16... 3.2 l/min
Areas of Application approx. 2.2 m/s 0.5 ... 10.0 l/min
G ¾ male 10 mm
Flow monitoring, flow measuring, dosing and approx. 3.5 m/s 0.8 ... 16.0 l/min
counting for
approx. 3.0 m/s 1.6 ... 32.0 l/min
OO Machine building G 1 male 15 mm
approx. 4.7 m/s 2.5 ... 50 l/min
OO Chemical Industry
approx. 3.3 m/s 3.2 ... 63 l/min
OO Paper Industry G 1½ male 20 mm
approx. 5.3 m/s 5.0 ... 100 l/min
OO Automobile Industry
approx. 3.3 m/s 8 ... 160 l/min
OO Cement Industry G 2 male 32 mm
approx. 6.6 m/s 16 ... 320 l/min
OO Laboratory
approx. 3.6 m/s 25 ... 500 l/min
G 2¾ male 54 mm
approx. 5.1 m/s 35 ... 700 l/min
 1/10 - 2018

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic Flowmeter Compact Model MIK

MIK-...F300, MIK-...F390 MIK-...Exxx (Counter electronics)


Impulse output: PNP, Open Collector, max. 200 mA Display: LCD, 2 x 8 digit, illuminated
500 Hz at full scale (...F300) total, part and flow quantities,
50...1000 Hz at full scale (...F390) units selectable
factory set as per customer re- Quantity meter: 8-digit
quest
Analogue output: (0)4...20 mA adjustable
Power supply: 24 VDC ±20 %
Load: max. 500 Ω
Power consumption: 60 mA
Switching output: 2 relays, max. 30 VAC/DC / 2 A / 60  VA
Electrical connection: plug M 12 x 1
Settings: via 4 buttons
Functions: reset, MIN / MAX memory,
MIK-...S300, MIK-...S30D flow monitor, monitoring for part
Display: duo-LED for switch status and total quantity, language
Switching output: relay SPDT, max. 1A/30VDC Power supply: 24 VDC ±20 %, 3-wire
or aktive 24 VDC, N/C / N/O Power consumption: approx. 150 mA
Switch point: 10 ...100% of full scale in Electrical connections: cable connection or M 12 plug
10%-steps that can be configured
by the customer using a rotary
More technical details see data sheet ZED
switch
Power supply: 24 VDC ±20 %
MIK-...Gxxx (Dosing electronics)
Power consumption: 80 mA
Display: LCD, 2 x 8 digit, illuminated
Electrical connection: plug M 12 x 1.5-pin
dosing-, total-, and flow quantity,
units selectable
MIK-...L303; MIK-...L343 Quantity meter: 8-digit
Output: 0(4)-20 mA, 3-wire Dosage: 5-digit
Max. load: 500 Ω Analogue output: (0)4...20 mA adjustable
Power supply: 24 VDC ±20% Load: max. 500 Ω
Power consumption: 80 mA Switching output: 2 relays, max. 30 VAC/DC / 2 A / 60  VA
Electrical connection: plug M 12 x 1 Settings: via 4 buttons
Functions: dosing (relay S2), start, stop,
MIK-...L443 (usage with AUF-3000) reset, fine dosing,
Output: 4-20 mA, 3-wire correction amount, flow switch,
Max. load: 500 Ω total quantity, language
Power supply: 24 VDC ±20% Power supply: 24 VDC ±20 %, 3-wire
Power consumption: 80 mA Power consumption: approx. 150 mA
Electrical connection: plug DIN 43650 Electrical connection: cable connection or M 12 plug

MIK-...C3xx (Compact electronics) More technical details see data sheet ZED
Display: 3-digit LED
Analogue output: (0)4...20 mA adjustable
(only MIK-...C34x)
Max. load: 500 Ω
Switching output: 1(2) semiconductor PNP or NPN,
set at factory
Contact function: N/C / N/O-frequency
programmable
Settings: via 2 buttons
Power supply: 24 VDC ±20 %, 3-wire
Power consumption: 120 mA
Electrical connection: plug M 12 x 1
 1/10 - 2018

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Electromagnetic Flowmeter Compact Model MIK

Electrical Connections

MIK-...S300 MIK-...S30D

Output 2 1 +Vs Output 2 1 +Vs


N/O N/C
Output
Common
5
GND Output GND Output
3 4 N/C 3 4 N/O

MIK-...L3x3, MIK-...F3x0 MIK-...L443

2 1 GND
n.c. +Vs

2
Signal
3 out
GND Signal out 1
3 4
+VS

MIK-...C30* MIK-...C34*
Switch out 2 2 1 +Vs 0(4)-20 mA 2 1 +Vs

GND GND
5
5
GND Switch out 1 GND Switch out 1
3 4 3 4

MIK-...E14R, MIK-...G14 Cable Connection Plug Connection

MIK-...E14R MIK-...G14R
Wire number +24 VDC 0 (4) - 20 mA Out
Counter electronics Dosing electronics
U max. 500 Ω
1 +24 VDC +24 VDC
1 2
2 GND GND Reset/Ctr 2*
5
3 4-20 mA 4-20 mA 4 3
d.c./Ctr 1* GND
4 GND GND
5 n.c. Control 1*
6 Reset part quantity Control 2*
30 VAC/DC / 2 A
7 Relay S1 Relay S1
U
8 Relay S1 Relay S1 1 2
S1
9 Relay S2 Relay S2 7 8 3
S2
10 Relay S2 Relay S2
4
Control 1 <-> GND: Start-Dosing 6
5
Control 2 <-> GND: Stop-Dosing
Control 1 <-> Control 2: Reset-Dosing
 1/10 - 2018

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic Flowmeter Compact Model MIK

Order Details (Example: MIK-5NA 10 A F300)

Model Range Connection set Electronics


Frequency output
..A.. = without1)
..08.. = 10…500 ml/min, G ½ ..F300 = M12-plug, 500 Hz
..P.. = PVC-hose connection ..F390 = M12-plug,
..10.. = 0.05…1.0 l/min, G ½
..E.. = stainless steel- 50...1000 Hz 2)
..15.. = 0.16…3.2 l/min, G ½
weld-on ends Switching output
..S300 = relay, M12-plug
..S30D = aktive 24 VDC,
MIK-5NA.. = PPS-housing, M12-plug
..20.. = 0.5…10.0 l/min, G ¾
NBR-seal, Analogue output
..25.. = 0.8…16.0 l/min, G ¾ ..A.. = without1)
stainless steel- ..L303 = M12-plug, 0 - 20 mA
..K.. = PVC-glue connection ..L343 = M12-plug, 4 - 20 mA
electrode
..P.. = PVC-hose connection ..L443 = DIN-plug, 4 - 20 mA
..E.. = stainless steel- Compact electronics4)
MIK-5VA.. = PPS-housing,
..30.. = 1.6…32.0 l/min, G 1 weld-on ends ..C30R = 2 x Open Coll. PNP
FPM-seal,
..35.. = 2.5…50.0 l/min, G 1 ..C30M = 2 x Open Coll. NPN
stainless steel-
..C34P = 0(4) - 20 mA,
electrode 1 x Open Coll. PNP
..C34N = 0(4) - 20 mA,
MIK-6FC.. = PVDF-housing, 1 x Open Coll. NPN
FFKM-seal, ..50.. = 3.2...63 l/min, G 1½ Counter electronics
Hastelloy®- ..55.. = 5.0...100 l/min, G 1½ ..E14R = LCD, 0(4)-20 mA,
electrode 2 x relay, 1.5 m cable
..E34R = LCD, 0(4)-20 mA,
2 x relay, M12 plug
MIK-6FT.. = PVDF-housing,
..A.. = without1) ..E94R = LCD, 0(4)-20 mA,
FFKM-seal,
..60.. = 8...160 l/min, G 2 ..K.. = PVC-glue connection 2 x relay,
Tantalum- cable >1.5 m3)
..65.. = 16...320 l/min, G 2 ..E.. = stainless steel-
electrode
weld-on ends Dosing electronics
..G14R = LCD, 0(4)-20 mA,
2 x relay, 1.5 m cable
..G34R = LCD, 0(4)-20 mA,
..80.. = 25...500 l/min, G 2 ¾ 2 x relay, M12 plug
..85.. = 35...700 l/min, G 2 ¾ ..G94R = LCD, 0(4)-20 mA,
2 x relay,
cable >1.5 m3)

1)
Incl. frontal gaskets (2 pc. o-rings)
2)
Please specify frequency at full scale in clear text while ordering
3)
Please specify cable length in clear text
4)
Please specify flow direction in clear text

Weight Sensor Weight Electronics

Model PPS PVDF Model Weight


MIK-...08/10/15 (½") approx. 180 g approx. 210 g MIK-...F3x0
MIK-...20/25 (¾") approx. 190 g approx. 225 g MIK-...S30x approx. 80 g
MIK-...30/35 (1") approx. 270 g approx. 325 g MIK-...Lxx3

MIK-...50/55 (1 ½") approx. 410 g approx. 500 g MIK-...C3xx approx. 300


MIK-...60/65 (2") approx. 560 g approx. 610 g MIK-...Exxx
approx. 250 g
MIK-...80/85 (2 ¾") approx. 1200 g approx. 1370 g MIK-...Gxxx

Total weight = weight sensor + weight electronics


 1/10 - 2018

No responsibility taken for errors; www.kobold.com 5


subject to change without prior notice.
Electromagnetic Flowmeter Compact Model MIK

Dimensions [mm]

Model G L1 L2 L3 L4 L5 L6 H1 H2
MIK-xxx08A
MIK-xxx10A G½ 118 90 14 46 58 36 43 28
MIK-xxx15A
MIK-xxx20A
G¾ 122 90 16 46 58 36 43 28
MIK-xxx25A
MIK-xxx30A
G1 126 90 18 46 58 36 49.5 29.5
MIK-xxx35A
MIK-xxx50A
G1 ½ 134 90 22 68 80 36 66 31.5
MIK-xxx55A
MIK-xxx60A
G2 138 90 24 68 80 36 72 36
MIK-xxx65A
MIK-xxx80A
G 2 ¾ 202 150 26 96 110 75 104 52
MIK-xxx85A

MIK-...F3x0, MIK-...S30x, MIK-...L3x3 MIK-...L443


L1 L1

M12 L3 L2 26 L3 L2
31

55,5
45,5
G
H1
H2

L4
H1
H2
9

L4
L5 L6
9

L5 L6

MIK-...C3xx MIK-...Ex4R, MIK-...Gx4R


48 90
L1
ø44,5 L3 L2
ca. 61
M12
61
37,5

G
H1
H2

L4
G
H1

9
H2

L5 L6
L4
L3 L2
9

L1

L5 L6
 1/10 - 2018

6 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Electromagnetic Flowmeter Compact Model MIK

L1 Dimensions connection set PVC-glue connection

3 L2 G D1 D2 D3 L1 L2
G½ not available
G¾ Ø 35 Ø 16 Ø 10.5 21 14
G1 Ø 43 Ø 20 Ø 15 23 16
G 1 ½ Ø 60 Ø 32 Ø 26 27 22
D3
D2
D1
G

G2 Ø 74 Ø 40 Ø 33 30 26
G 2 ¾ Ø 103 Ø 63 Ø 54 38 38

Dimensions connection set PVC-hose connection


L1
G D1 D2 L
G½ Ø 14 Ø 12 56
D1
D2

G¾ Ø 18 Ø 16 60
G

G1 Ø 22 Ø 20 67
G 1 ½ not available
G2 not available
G 2 ¾ not available

Dimensions connection set stainless steel weld-on ends


L
G SW L D1 D2
G½ 24 45 Ø 10.2 Ø5
SW

D1
D2
G

G¾ 32 45 Ø 13.5 Ø 10
G1 41 45 Ø 19 Ø 15
G 1 ½ 55 60 Ø 25 Ø 20
G2 70 60 Ø 38 Ø 32

38 G 2 ¾ 90 60 Ø 60.3 Ø 54
 1/10 - 2018