Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

ENGR. C.

LEOBRERA

LECTURE 10 & 11 EXAMPLES

CE 156 STEEL STRUCTURES 1


EXAMPLE 1 ENGR. C. LEOBRERA

Find the Capacity of the Bearing Type Connection.

• A36 Plate
• 7/8” A325-X

Determine if connection meets


Layout requirements

CE 156 STEEL STRUCTURES 2


EXAMPLE 2 ENGR. C. LEOBRERA

CE 156 STEEL STRUCTURES 3


EXAMPLE 3 ENGR. C. LEOBRERA

PL 9” x 7/8”

CE 156 STEEL STRUCTURES 4


EXAMPLE 4 ENGR. C. LEOBRERA

(4 bolts)

CE 156 STEEL STRUCTURES 5


EXAMPLE 5 ENGR. C. LEOBRERA

Assume Capacity of Tension Member to be adequate

CE 156 STEEL STRUCTURES 6


EXAMPLE 6 ENGR. C. LEOBRERA

Assume Capacity of Tension Member to be adequate

CE 156 STEEL STRUCTURES 7


EXAMPLE 7 ENGR. C. LEOBRERA

Assume Capacity of Tension Member to be adequate

CE 156 STEEL STRUCTURES 8


EXAMPLE 8 ENGR. C. LEOBRERA

E70XX Electrodes Used

CE 156 STEEL STRUCTURES 9


EXAMPLE 9 ENGR. C. LEOBRERA

For the A36 steel bracket plate of the accompanying


figure, calculate the maximum service load P (15% dead
load and 85% live load) when 7/8 inch diameter A325
bolts are used in a bearing-type connection (A325-N)
with threads included in the shear planes.

(a) Use the elastic (vector) method.


(b) Use the AISC Manual Tables.

CE 156 STEEL STRUCTURES 10