Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A B C A B C A B C

6.98 6.98 6.98

3.00 3.98 1.50 3.00 3.98 1.50 3.00 3.98 1.50


0.75
1.50

1.50

1.50
1.49

1.49
1.05

4 4 4
0.60
3.00

3.00

3.00

3.00

3.00
3.15

3.15
3.70
8.49

8.49

8.49
3 3 3
5.09

1.64

1.69
3.99

3.99

3.99

3.99

3.99
1.05

3.29

1.00
1.00
1.15
1.00

2 2 2
M
3.00

3.00
3.00

3.00

3.00
1 1 1
3.15 3.83 1.78 3.15 3.83 1.78

6.98 6.98 6.98


GROUND FLOOR SECOND FLOOR ROOF DECK
SANITARY LINE LAYOUT SANITARY LINE LAYOUT DRAINAGE LINE LAYOUT
N SCALE 1 : 50 METERS N SCALE 1 : 50 METERS N SCALE 1 : 50 METERS

A B C A B C A B C
6.98 6.98 6.98

3.00 3.98 1.50 3.00 3.98 1.50 3.00 3.98 1.50


0.75
1.50

1.50

1.50
1.49

1.49
1.05

4 4 4
0.60
3.00

3.00

3.00

3.00

3.00
3.15
3.70

GENERAL NOTES : MATERIAL SPECIFICATIONS :


8.49

8.49

8.49

1. ALL PLUMBING WORKS INCLUDE HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISIONS OF THE PHIL.
3 3 3 PLUMBING CODE. THE NATIONAL BUILDING CODE & THE RULES AND REGULATIONS OF THE MUNCIPALITY/CITY. COLD WATER LINES USE POLYPROPYLENE (PPR) PIPES & FITTINGS
PN 20 "DURA BEND" BRAND OR APPROVED EQUAL.
5.09

2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS , THE ENGINEER SHALL BE
NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN. SEWER LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTINGS, SERIES 1000 /
CLASS 35. USE "EMERALD" BRAND OR APPROVED EQUAL.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATIONS REQUIRED FOR PROPER EXECUTION
OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. WASTE LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTINGS, SERIES 1000 /
3.99

3.99

3.99

3.99

3.99

CLASS 35. USE "EMERALD" BRAND OR APPROVED EQUAL.


1.05

3.29

4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF
ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR. VENT LINES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTINGS, SERIES 1000 /
CLASS 35. USE "EMERALD " BRAND OR APPROVED EQUAL.
1.15

5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2% UNLESS OTHERWISE SPECIFIED.
1.00

GATE VALVE "KITZ", "CRANE" OR APPROVED EQUAL.


2 2 2 6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. CHECK VALVE "KITZ", "CRANE" OR APPROVED EQUAL.

7. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATE THE WORKS WITH THE SEWER DOWNSPOUT SHALL BE POLYVINYL CHLORIDE (PVC) PIPES & FITTINGS, SERIES 1000 /
LINE EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE CONNECTING POINT UNLESS OTHERWISE SPECIFIED. CLASS 35. USE "EMERALD" BRAND OR APPROVED EQUAL.
3.00

3.00
3.00

3.00

3.00

8. ALL PIPES SIZES ARE IN MILLIMETERS AND ALL DIMENSIONS (INSIDE DIAMETER) ARE IN METER UNLESS. ROOF DRAIN/DECK DRAIN USE "METMA" M-319-20 BRAND OR APPROVED EQUAL.
OTHERWISE SPECIFIED.
FLOOR DRAIN USE "METMA" M-216 BRAND OR APPROVED EQUAL.
9. ALL HORIZONTAL PIPING SHALL BE SUPPORTED AND ANCHORED AT INTERVALS NOT TO EXCEED 3 METERS
TRENCH DRAIN USE "METMA" M-319-52 BRAND OR APPROVED EQUAL.
1 1 1
3.00 3.98 1.78 3.15 3.83 1.78 3.15 3.83 1.78

6.98 6.98 6.98


GROUND FLOOR SECOND FLOOR GROUND FLOOR PLAN
WATER SUPPLY LINE LAYOUT WATER SUPPLY LINE LAYOUT SANITARY LINE LAYOUT
N SCALE 1 : 50 METERS N SCALE 1 : 50 METERS N SCALE 1 : 50 METERS