2

= 0.75 m
A.Y = 0.1815 + 0+ 0.1125 + 0.6435 + 0
3
= 0.9375 m
Y,left = 1.250 m

4 Check for uplift capacity of the anchor block


Volume of soil = 13.75 + 13.97188 + 3.716853
3
= 31.43873 m
3
Net Vol. of soil = 31.43873 - 0.198 = 31.24073 m
Uplift capacity of the block
Wt of soil = 31.24073 x 1.44 = 44.98665 t
Wt of chimney = 0.198 x 2.4 = 0.4752 t
Total wt soil and concrete = 45.46185 t
Maximum uplift on the anchor block = 4.330 t OK

5 Bearing capacity check


5.1 Self wt of soil & concrete
3
Vol. of soil = 13.75 m
3
Vol. of concrete in chimney = 0.198 m
3
Vol. of concrete in slab = 1.875 m
3
Vol. of lean concrete = 0.729 m

3
Net vol. of soil = 13.552 m

Compression at the base of the footing


Net soil wt = 13.552 x 1.44 = 19.51488 t
Chimney = 0.198 x 2.4 = 0.4752 t
Slab = 1.875 x 2.4 = 4.5 t
Lean concrete = 0.729 x 2.4 = 1.7496 t
Total wt of soil & concrete 26.2397 t

5.2 Moment due to uplift


Moment due to upilft force M,t = -4.330 x 0.0000 = 0.000 tm

6 Side thrust
Depth of Soil Mobilization Level from GL = 0.500 m
Kp = 3
Passive pressure resistance height required = 1.964 m
Availlable height for the resistance = 2.2 m
Actual height for the passive resistance = 1.700 m
Minimum effective value of resistance = 1.700
Resisting Soil Force = 1.87 t

Moment at the base due to side thrust = 2.500 x 2.8 = 7.00 tm


Moment at the base due to soil resistance = 2 x 1 = 1.94 tm
Net moment at the base of the footing = 5.064856 tm

7 Stress at the base of the footing


Axial force at the base of the footing P = -4.330 + 26.23968 = 21.910 t
Total moment at the base of the footing M = 5.064856 tm
2
Area of the raft A = 6.25 m
3
Z = 2.604167 m

2
Corner stress σ1 = 3.505528 + 1.944905 = 5.450433 t/m OK
2
σ2 = 3.505528 - 1.944905 = 1.560624 t/m OK
2
Gross allowable bearing pressure = 50 + 3.168 = 53.168 t/m

8 Section design
fy = 500 Mpa
Es = 210000 Mpa
fck = 25 Mpa