Address List Page 1 of 11

Help > HMI System Address >

HPW Address
Address Meaning Description
For download, when the recipe transfer unit is triggered
by the user, software obtains the recipe group number
from HPW0 and then downloads the recipe to the
terminal. For upload, when the recipe transfer unit is
Group number of
HPW0 triggered by the user, software will obtain the recipe
recipe
group number from HPW0 and then save the recipe
from PLC upload to the place where the group is
located, and the original recipe data of the group will be
overwritten.
HSW Address
Address Meaning Description
Save
HSW0 Save the parameter of project when HSW0=1
parameter settings
Cancel parameter Cancel the parameter of project when HSW0 and
HSW1
Settings HSW1 is mutually exclusive
COM1 of HMI
HSW2 Reserved
station No.
COM1 of PLC
HSW3 Reserved
station No.
0: RS232
Type of COM1
HSW4 1: RS485
serial port
2: RS422
COM serial port with 0: COM1
HSW5
PLC 1: COM2
0: 2400
1: 4800
2: 9600
COM1 baud rate
HSW6 3: 19200
(BPS)
4: 38400
5: 57600
6: 115200
0: 7
HSW7 COM1 data bits
1: 8
0: None
1: Odd
HSW8 COM1 check bits
2: Even
3:SPACE
0: 1 Bit
HSW9 COM1 stop bit
1: 2 Bit
0: None
HSW10 COM1 flow control 1: Software
2: Hardware
COM1 number of
HSW11
retied
COM1 waiting
HSW12 Unit: millisecond
timeout
COM1 receiving
HSW13 Unit: millisecond
timeout
HSW14 Default screen No. The first screen after starting the HMI
0: language 1
HSW15 Display language 1: Language 2
2: Language 3
HSW16 Font Reserved
HSW17 Font size Reserved
HSW18 Font quality Reserved
0: True

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 2 of 11

HSW19 Touch buzzer 1: False


LCD Anti-color 0:False
HSW21
display 1:True
0: False
HSW24 Restart HMI
1: True
HSW26 Printer type Reserved
HSW27 Print port Reserved
HSW28 Local time - year Range: 0~9999
HSW29 Local time - month Range: 01~12
HSW30 Local time - Day Range: 01~31
HSW31 Local time - Hour Range: 0~23
HSW32 Local time - Minute Range: 0~59
HSW33 Local time - Second Range: 0~59
HSW34 Upload project 1: Upload (Reserved )
HSW35 Download project 1: Download (Reserved)
Type of COM2 0: RS232
HSW36
serial port 1: RS485
0: 2400
1: 4800
2: 9600
3: 19200
HSW37 COM2 baud rates
4: 38400
5: 57600
6: 115200
7: 115200
0: 7
HSW38 COM2 data bits
1: 8
0: None
1: Odd
HSW39 COM2 check bit
2: Even
3: SPACE
0:1 Bit
HSW40 COM2 stop bit
1:2 Bit
0: None
HSW41 COM2 flow control 1: Software
2: Hardware
COM2 number of
HSW42
retied
COM2 waiting
HSW43 Unit: millisecond
timeout
COM2 receiving
HSW44 Unit: millisecond
timeout
String input by
HSW45 keypad display in Input by keypad display in buffer area
buffer area
HSW112 Security protection 1: Enable security protection
1: level 1
2: level 2
HSW113 Security level
3: level 3
......
1: level 1
2: level 2
Current security
HSW114 ……
level
11: level 11
12: level 12
Screen contract
HSW125
setting

0:Sunday
1:Monday
HSW126 Local time - week 2:Tuesday
3:Wednesday
4:Thursday
5:Friday

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 3 of 11

6:Saterday
0: normal beeping
HSW127 Beep
1: keep beeping (unlatched )
HSW128 Script running cycle
Script running
HSW129 cycle is whether
variable or not
HMI IP address 1
HSW136
(left to right)
HMI IP address
HSW137
2 (left to right)
HMI IP address
HSW138
3 (left to right)
HMI IP
HSW139 address 4 (left to
right)
HMI subnet mask 1
HSW140
(left to right)
HMI subnet mask
HSW141
2 (left to right)
HMI subnet mask
HSW142
3 (left to right)
HMI subnet mask
HSW143
4 (left to right)
HMI default gateway
HSW144
1 (left to right)
HMI default gateway
HSW145
2 (left to right)
HMI default gateway
HSW146
3 (left to right)
HMI default gateway
HSW147
4 (left to right)
HSW148 HMI port address
Security level
0: False
HSW157 password
1: True
independent
Reserved HSW160~HSW163,total 4 bytes,max input is
HSW160 Password
8 characters password
The register number
which the current
1: level 1
HSW168 security level
2: level 2
password
switched lower
COM 1 timeout
HSW169 Range: 0~65535
retried
COM 2 timeout
HSW170 Range: 0~65535
retried
COM1 IO delay
HSW173 Range: 0~65535
read or write
COM2 IO delay
HSW174 Range: 0~65535
read or write
COM3 IO delay
HSW175 0~65535
read or write
Painting or
0: not heavy painting or empty
HSW00176 empty history XY
1: heavy painting or empty
plot
Display an error 0: False
HSW189
message 1: True
Empty record data 0: False
HSW191
files 1: True
Empty system 0: False
HSW192
configuration files 1: True
Min range of

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 4 of 11

keyboard
HSW193~194 0~0xFFFFFFFF
input,double word
Max range of
HSW195~196 keyboard 0~0xFFFFFFFF
input,double word
The number of
HSW200
current bit alarm
The number of
HSW201
current word alarm
0: False
Empty bits alarm
HSW202 1: True
data
2: Delete
0: False
Empty words alarm
HSW203 1: True
data
2: Delete
1: clear all file under” \ \ Flash \ \ Data “
2: clear all file under”\ \ Flash \ \Data \ \ DL “
3: clear all file under”\ \ Flash \ \ Data \ \ AL “
Clear file under “\
4: clear all file under”\ \ CFDC \ \ Data “
Flash \ Data”,check
HSW205 5: clear all file under”\ \ CFDC \ \Data \ \ DL “
data after re-power
6: clear all file under”\ \ CFDC \ \Data \ \ AL “
on.
7: clear all file under”\ \ Udisk \ \ Data”
8: clear all file under”\ \ Udisk \ \Data \ \ DL "
9: clear all file under” \ \ Udisk \ \ Data \ \ AL “
Close pop-up
window (only for It is valid when hsw214=1(word switch is suggested,
HSW214
alarm window and script doesn't work)
builtin 1013 screen)
Keyboard case 0:capital
HSW216
switching 1:lowercase
Clear multi- 0:False
HSW217
language setting 1:True
Settings screen 0:False
HSW218
saver switch 1:True
Start time of screen
HSW219 Unit: second
saver countdown
Screen saver
HSW220 Unit: second
countdown
HSW221 Screen sleep Unit: second
0:True
HSW223 Beep when alarm
1:False
PLC station No. Of
HSW224 Range: 0~255
COM2
HMI station No. Of
HSW225 Range: 1~255
COM2
PLC station No. Of
HSW227 Range: 0~255
COM2
HMI station No. Of
HSW229 Range: 1~255
COM2
Save CF/SD card
HSW230 System occupied
data to U disk
Read data from 0: False (from ache)
HSW233
Script 1: True (from PLC)
HSW238 Bit alarm flag 1: True
HSW239 Word alarm flag 1: True
Group number of
HSW243 Range: 1~3
Discrete recipe
Recipe upload or 1: upload
HSW244
download 2: download
HSW245 Clear alarm record Clear alarm record
Type of
HSW247 0: RS485
COM3 serial port

0: 2400

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 5 of 11

1: 4800
2: 9600
3: 9600
HSW248 COM3 baud rates 4: 19200
5: 38400
6: 57600
7: 115200
0: 7
HSW249 COM3 data bits
1: 8
0: None
1: Odd
HSW250 COM3 parity
2: Even
3: SPACE
0: 1 Bit
HSW251 COM3 stop bit
1: 2 Bit
0: None
HSW252 COM3 flow control 1: Software
2: Hardware
COM3 number of
HSW253
reties
COM3 waiting
HSW254 Unit: millisecond
timeout
COM3 receiving
HSW255 Unit: millisecond
data timeout
Save parameters of
0:True
HSW256 group No.0 data
1:False
record
Sampling period of
HSW257 group No.0 data Unit: second (0 ~ 65535)
record
Autosave period of
HSW258 group No.0 data Unit: minutes (0 ~ 65535)
record
The type of saving 0:According to setting to save data
HSW259 data of group No.0 1:save data to CF/SD card, data in HMI will be
data record cleared automatically
Save parameters of
0:True
HSW260 group No.1 data
1:False
record
Sampling period of
HSW261 group No.1 data Unit: second (0 ~ 65535 )
record
Autosave period of
HSW262 group No.1 data Unit: minutes( 0 ~ 65535)
record
The type of saving
0:According to setting to save data
HSW263 data of group No.1
1:save data to CF/SD card, data in HMI will be cleared
data record
… … …
Save parameters of
0:True
HSW296 group No.10 data
1:False
record
Sampling period of
HSW297 group No.10 data Unit: second (0 ~ 65535 )
record
Autosave period of
HSW298 group No.10 data Unit: minutes(0 ~ 65535)
record
The type of saving
0:According to setting to save data
HSW299 data of group
1:save data to CF/SD card, data in HMI will be cleared
No.10 data record
... ... ...
HSW456 Save parameters of
group No.50 data 0:True

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 6 of 11

record 1:False
Sampling period of
HSW457 group No.50 data Unit: second (0 ~ 65535 )
record
Autosave period of
HSW458 group No.50 data Unit: minutes(0 ~ 65535)
record
The type of saving
0:According to setting to save data
HSW459 data of group
1:save data to CF/SD card, data in HMI will be cleared
No.50 data record
Default level of parts
HSW501
security
HSW502 Current level of
parts security
Import group No. of
HSW503
recipe
export group No. of
HSW504
recipe
HSW505=0,No operation
HSW505=1,Copy your choose files to _T(“\\flash\\recp”)
HSW505=2,Copy all files to _T(“\\flash\\recp”)
HSW505=3,Copy the same files between _T
(“\\flash\\recp”) and your choose files to “file list path”
HSW505=4,Copy _T("\\flash\\recp") to “file list path”
HSW505=5,Delete your choose files in “file list path”
HSW505=6,Delete all files in “file list path”
HSW505 Delete the file list
HSW505=7,Delete the same files in _T(“\\flash\\recp”)
and your choose files in the file list
HSW505=8,Delete all files in _T(“\\flash\\recp”)
HSW505=9,Delete the files in _T(“\\flash\\recp”) and
your choose files in the file list
HSW505=10,Delete all files in _T(“\\flash\\recp”) and in
the file list
HSW505=11,Update the list in _T(“\\flash\\recp”)
Clear the current
HSW506
event list
Clear history event
HSW507
list
Delete EVReg.dat
HSW508
files
Parts security
HSW509
password separated
Whether opening
HSW500
parts password
X position of
HSW543
touching
Y position of
HSW544
touching
U disk state for print
HSW546 HSW546=1
part
State of saving HSW547=1:Saving
HSW547
picture HSW547=2:Saved
Screen No. of
HSW545
screen saver
HSW542 =1 Memory is full
HSW661~HSW666,Means year, month, day,
HSW661 File list
hour,minute,second for File list
HSW667=10000:importing
HSW667=10000+group:Import success
HSW667 File list import HSW667=20000:Import failure
export state HSW667=30000:Exporting
HSW667=30000+group:Export success
HSW667=40000+group:Export failure
HSW668=0: default value.HSW668=0 when using the

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 7 of 11

function breaker of saving CF/SD card data to U-disk


and saving FLASH data to U-disk and writing the
HSW668 is address in HSW205 manually
prepared for alarm HSW668=1: excuting the operation of saving CF/SD
records and data card data to U-disk
HSW668 records.Different HSW668=2: excuting the operation of cutting CF/SD
values of HSW668 card data to U-disk
means different HSW668=3: excuting the operation of saving FLASH
functions data to U-disk
HSW668=4: excuting the operation of cutting FLASH
data to U-disk
HSW669=0,without U-disk
HSW669=1,exist U-disk & without reading or without
writing
HSW669
HSW669=2,exist U-disk & reading or writing
HSW669=3,exist U-disk but U-disk has been unstalled
(maybe it has a problem)
HSW670 set 125,250,500,1000 for baud rate,which
HSW670 CAN baud rate
means 125K,250K,500K,1000K
USing custom name
HSW=0,false
HSW677 of saving data to U-
HSW=1,true
disk
When HSW677=1, it’s working.in other words,when
Holding the custom
HSW678 saving FLASH data to U-diak,which will create a list
part number
“HMIDataXXX”(XXX means the value in HSW678)
Don’t display HSW682=1,it’s working.when HMI can’t communicate
HSW682
timeout with out address,the screen won’t display timeout
Display the script HSW683=0,false
HSW683
abnormal HSW683=1,true
Time of keyboard
HSW685 Unit: millisecond
input
Min range of
HSW687 8 words,display by text
keyboard input
Max range of
HSW695 8 words,display by text
keyboard input
= 2: yyyy-mm-dd
= 3: hh:mm:ss
Alarm printing time
HSW703 = 4: yyyy-mm-dd hh:mm
mode
= 5: mm-dd hh:mm:ss
=others: yyyy-mm-dd hh:mm:ss
= 1: print time after printing content
HSW704 Alarm printing order
=Other: print content after printing time
Alarm printing = 1: reverse
HSW705
direction = Other: positive
Address about the
HSW706 value of keyboard When using allowed keyboard’ mirror&OS,it’s working
input
Components is
locked each
HSW711=0,true
HSW711 other,clicking will
HSW711=1,false
prompt “touch is
forbidden ”
The address of the
value which is
HSW713~HSW743 keyed in Component should be text,longth is 62 characters
number/text
component
When holding the
screen down, click
on the device =0: enabled (default)
HSW766 address to see if it =1: not enabled
responds quickly
(Enable: does not
respond to the click

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 8 of 11

action of the
component;
Unenable: response
part click action, set
address to be
written value)
Read or write data by this area frequently may damage
HSW744~HSW1255 Latched address
FLASH
= 1: Refresh the file list and automatically zero when
HSW10385 Refresh file list
done
Data record auto
HSW10400 =1: Auto refresh shows 500 data records
refresh
Valid when HSW677 = 2. When the data is transferred
from HMI flash to the USB flash drive, a directory of
Folder name XXX is created in the root directory of the USB flash
HSW10463~HSW10470
register drive, and "XXX" is the text defined by HSW10463-
10470. (Text cannot only be numeric, alphabetic (the
letters are case sensitive))
Whether display the operation result in HSW244.
Recipe operation
HSW10475 = 1: Yes
tips
= others: No
HSX10000.0 User login Switch ON
HSX10000.1 Change password Switch ON
HSX10000.2 User launch Switch ON
HSX10000.3 Add user Switch ON
HSX10000.4 Delete user Switch ON
Add user from one
HSX10000.5 Switch ON
group
Delete user from
HSX10000.6 Switch ON
one group
HSX10000.8 Delete profile Switch ON
HSX10000.9 Export profile Switch ON
HSX10000.10 Import profile Switch ON
Export operation
HSX10000.11 Switch ON
records
Delete operation
HSX10000.12 Switch ON
records
=1,Insufficient authority to operate
=2,User doesn’t exist
=3,User has exised
=4,Wrong password
=5 ,login successfully
=6,Input password is inconsistent twice
=7,Change password successfully
=8,Add user successfully
=9,Delete user successfully
=10,Over the max number of user
Result display when
HSW10001 =11,User has existed in the group
user is operating
=12,User has been added in the group successfully
=13,User doesn’t exist in the group
=14,Remove user successfully
=15,Import file successfully
=16,Import file unsuccessfully
=17,Export file successfully
=18,Export file unsuccessfully
=19,User launch
=20,Delete profile successfully
=21,Delete operation records successfully
HSW10002 Old password When user is changing password,it still works
HSW10006 New user password
HSW10010 New user password Confirm new user password
HSW10014 New user name
Current system time
HSW10022~HSW10039 Display the time which included login and launch
display

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 9 of 11

User name in the


HSW10060~HSW10148 Diaplaying all users name in the group
group
HSW10149~HSW10260 All groups’ name Displaying all groups’ name
Numeric input
component : single Setting to 6 rows and 7 columns, which is been
HSW10300~HSW10341
byte,unsigned int displayed the date in the calendar
and can’t input
Setting to 6 rows and 7 columns,which can follow the
Switching bit’s
HSX10342.0~HSX10344.9 numeric input component(using two colors stand for
address
different state)
Numeric input
HSW10345 Year in the calendar
component
Numeric input
HSW10346 Month in the calendar
component
Numeric input
HSW10347 Day in the calendar
component
Using the
=0,false
HSW10350 import/export
=1,true
function
Start ingredient
Start ingredient number must be lower than ingredient
number of
HSW10351 number of every recipe and higher than zero,otherwise
import/export,double
it will be false
words
Continuous to
Continuous number means exporting the number of
import/export the
ingredient behind start ingredient number.what’s more,
HSW10353 number of
they must be lower than ingredient number of every
ingredient,double
recipe and higher than zero,otherwise it will be false
words
Continuous to export the number of recipe behind
Continuous to
having set the number of starting ingredient and
HSW10355 export the number
continuous ingredient,which must be higher than
of recipe
zero,otherwise it will be false.
Address of
=0,default setting
HSW10357 importing/exporting
=1,importing/exporting data of the recipe
recipe
Set data from the
Set data=0 or data=1 from the file list to import blank
HSW10358 file list to import
row
blank row
Reminding =0,default setting: 5/3/1 days in advance
HSW10370
installment due day =1,customize setting
Setting installment
HSW10371 First time setting (Unit: day)
reminder due day
Setting installment
HSW10372 Second time setting (Unit: day)
reminder due day
Setting installment
HSW10373 Third time setting (Unit: day)
reminder due day
Starting the function
HSW10375 =1, login of installment display
of installment
Reminding
HSW10376 installment will be HSW10376=1,when installment will be due day
due day
Showing / hiding
historical trend HSW10380<>0,hiding historical trend serial port print
HSW_10380
serial port print button
button
HDW25000 The recipe of file list The name of file from file list to import
HDW25001 The recipe of file list The name of file from file list to export
The number of
HDW25002~25003 Saving the number of bit alarm records
alarm
The number of
HDW25005~25006 Saving the number of word alarm records
alarm

HDW3500~7999 Reflecting the word MODBUS RTU master is the address from 40 to 499.
address of For example ,HDW3500 means 40 and HDW3510

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 10 of 11

MODBUS means 410


Reflecting the bit MODBUS RTU master is the address from 00 to
HDX3000.0~3499.15 address of 007999. For example ,HDW3000.0 means 00 and
MODBUS HDW3000.1 means 01
Total addresses length: 16 K + 2000 words,
Storage protection
HDW8000~HDW30000 Read or write data frequently by this area may damage
for power data
FLASH
HDW40000~HDW50000 Special address Storage the number of last screen
Picture level password
Safety level 1
HSW404 Total 8 bytes
password
Safety level 2
HSW408 Total 8 bytes
password
Safety level 3
HSW412 Total 8 bytes
password
Safety level 4
HSW416 Total 8 bytes
password
Safety level 5
HSW420 Total 8 bytes
password
Safety level 6
HSW424 Total 8 bytes
password
Safety level 7
HSW428 Total 8 bytes
password
Safety level 8
HSW432 Total 8 bytes
password
Safety level 9
HSW436 Total 8 bytes
password
Safety level 10
HSW440 Total 8 bytes
password
Safety level 11
HSW444 Total 8 bytes
password
Safety level 12
HSW448 Total 8 bytes
password
Parts level password
Password using the internal parts HSW address words address type
safety level 1 Total 8 bytes HSW452
safety level 2 Total 8 bytes HSW456
safety level 3 Total 8 bytes HSW460
safety level 4 Total 8 bytes HSW464
safety level 5 Total 8 bytes HSW468
safety level 6 Total 8 bytes HSW472
safety level 7 Total 8 bytes HSW476
safety level 8 Total 8 bytes HSW480
safety level 9 Total 8 bytes HSW484
safety level 10 Total 8 bytes HSW488
safety level 11 Total 8 bytes HSW492
safety level 12 Total 8 bytes HSW496

open parts level password HSW500


The default parts password level HSW501
Current part password level HSW502
Local IP address high byte 1 HSW136
Local IP address high byte 2 HSW137
Local IP address high byte 3 HSW138
Local IP address high byte 4 HSW139
Local mask IP address high byte 1 HSW140
Local mask IP address high byte 2 HSW141
Local mask IP address high byte 3 HSW142
Local mask IP address high byte 4 HSW143
Local gateway IP address high byte 1 HSW144
Local gateway IP address high byte 2 HSW145
Local gateway IP address high byte 3 HSW146

mk:@MSITStore:C:\Program%20Files%20(x86)\LeviStudioU\EN_HmiHelp.chm::/10/10.... 3/27/2020
Address List Page 11 of 11

Local gateway IP address high byte 4 HSW147


Local port address HSW148

Copyright © 2019. All rights reserved. V6.01.30