Internal test-3DEM

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Reg.

No
SSM INSTITUTE OF ENGINEERING AND TECHNOLOGY
Dindigul – 624 002.

Department of Electrical and Electronics Engineering


Internal test -III
EE 6604-Desgin of Electrical machines
Year/Sem/Sec: III/ VI Time: 3.00P.M to 4.30P.M
Date: 16.03.20 Max Marks: 50
PART-A (10x2=20 Marks)

Q.No Questions
PART-B 1 List out the factors that are affected due to SCR.
(2x15=30
Marks) 2 Categorize the rules for selecting rotor slots of squirrel cage machines..
3 Illustrate the factors to be considered for the choice of specific electric loading..
Q.No Questions
4 Write the factors to be considered for the choice of specific magnetic field.
21.a)(i) Explain in detail about the design of endrings.(10)
5
21.a)(ii) Illustrate the
Calculate howvalue
the induction motorcurrent
of magnetizing can beperdesigned
phase forfor best powerfactor.
a 15KW, 400V, 3 phase , 50Hz,
6 6Distinguish
pole inductionbetween
motorSalient pole rotor
has a diameter and cylindrical
of 0.3m and the length pole rotor.0.12m. The number
of core
7 of stator
List out slots is 72 with
he factors 20 conductors
that govern the designper slot. The in
of field stator is delta connected. length of air
the armature.
8 gap is 0.55m. The gap contraction
Illustrate short circuit ratio.. factor is 1.2. Assume the mmf required for the iron
parts to be 35 percent of the air gap mmf. Coil span = 11 slots.(5)
9 Define runaway speed..
21.b) Evaluate and design a cage rotor for a 40HP, 3-phase, 400V, 50Hz, 6 pole delta
10 Describe the
connected IMpurpose
having of providing
a full damper winding
load efficiency of 87% in andsynchronous
a full load pfmachines
of 0.85. Take
11 What is the critical speed of alternator ?
D=33cm and L=17cm. stator slots=54, conductors/slot=14. Assume suitably the
12 missing
What is data
Shortofcircuit
any.(15)
ratio?
22.a)13 List out
Solve thethe functions
main of damper
dimensions winding
of a 75000 KVA, 13.8KV, 50Hz, 62.5rpm, 3 phase star
14 connected alternator. The peripheral
What is circle diagram? Mention its speed isinabout
importance 40m/s.
induction motorAssume average gap
15 density=0.65wb/m2,
Define crawling and how ampere conductors/metre=
it can be minimised? 40,000 and current density=4A/mm2.
16 Also find the no. of stator slots, conductors per slot,
What are the factors that influence the choice of specific magnetic conductor area. in
loading (15)
synchronous
22.b)17 machines?
Evaluate
Prepare the suitable
the factors damper for
to be considered winding forof the
selection machine
armature slots with 1250KVA,3 phase ,
for alternators
18 6600V,salient pole alternator ,airgap diameter =1.6m,Length of the core
Tabulate the difference between salient pole rotor and cylindrical rotor type alternator
19 =0.45m,number of poles =20,armature ampere conductors per meter =28000,ratio
State any three rules for concerning the choice of rotor slots for squirrel cage machines.
of
pole arc to pole pitch=0.68,stator slot pitch=28mm,current density in damper bar
20 Mention any
=3A/mm 2. three important features of turbo-alternator rotors?
(15)

Faculty Signature HOD/EEE

You might also like