Powerlift Form A-01 Ref No.

04/01/2020-01

Package:
ESP COMPLETION DESIGN
D
Customer: PHE OSES Delivery Date: 09/Mar/20 Wellhead: Junction Box: Transformer: Switchboard/VSD:
Well Name: CINH-01 Powerlift Crew:
Field / Location: SBU Barge/Rig: 0

Item Type/Description P/N Qty/Length


Surface Cable: BIW Surface Cable
Power plug BIW EM52062-129-040 1EA
Penetrator: BIW EM51015-1 1EA POWERLIFT

Downhole Connector: BIW EM53013-R18 1EA


Packer 0 0
Cable Protectors: Gulf coast for 3 1/2" TBG 125 EA

Protectorlizer Junction Box Transformer Switchboard

X-Over KVA = 300


Tubing Size: 3 1/2" Tubing
Casing Size/Weight: 9 5/8" Casing
Pump Set. Depth : 3,400 Feet
Expected Flow Range: 4000 BPD
Item Series Description Serial Number Item OD (Weight) Length (in Ft)
Power Cable: AWG Round Cable Cable: AWG # 1 3,500
Discharge Head: 3 1/2" 0.80 Discharge: 3 1/2"

Pump UT: 130 QN55 ARC 56 STGS Pump UT: 5.11 13.48

Pump LT: 130 QN55 ARC 56 STGS Pump LT: 5.11 13.48
0 0 0.00 0.00 0 0.00 0 0.00 0.00

Intake 130 NI-AR-CCR-AS-N Anti-corrosion Intake 5.11 2.76

Protector DT: 130 NPBPBSLST-AR-CCR-PL3-RF-FD-E-INC Anti-corrosion Protector DT: 5.11 12.20

MLE: AWG MLE flat / New Length of MLE to BOH : 41.92 82.00

Motor UT: 143 225 HP 2220 V 58 A Motor UT: 5.62 23.67

Motor LT: 0 0 HP 0 V 0 A 0 Motor LT: 0.00 0.00

Crossover
Downhole Monitor: 114 Phoenix Downhole Tool: 2.43

Motor shroud n/a For 9 5/8" Casing N/A

Motor Guide/Centralizer
Casing or liner size: Using 9 5/8 centralizer 8.00 2.10

Total length =>>> 70.12

Name Signature Name Signature Date


Superintendent: Wang Hui 06/Mar/20
A. E. Sarip Hidayat
Customer Reps:

CNOOC SES Ltd.ESP Runlife Service Pakage D Contract No.:xxxxxx


Powerlift Form A-05 Ref No.04/01/2020

Package:
SURFACE VOLTAGE CALCULATION
D
Customer: PHE OSES Delivery Date: 9/Mar/20
Well No.: CINH-01 Powerlift Crew:
Field Name: SBU Barge Name: $0.00

Pump Setting Depth : 3,400 FT


VOLTAGE DROP
Pump Type : QN55 60

Number of Stages 112 Stages 55

#4

VOLT DROP PER 1000 FEET


Motor HP : 225 50

Nameplate Amps : 58 45

40
Nameplate Volts : 2220
35

30 #1
HP / Stages : 1.7 HP 25

Protector : 3 HP 20
Intake : 2 HP
15

Cable Type : Round Cable 10

MLE Length (A) : 82 FT 5

Cable Length (B) : 3,400 FT 0

100

110

130

140
120

150
10

20

40

50

70

80
30

60

90
Sub-Sea Length ( C ) : FT AN TIC IPATED MOTOR CU RRE NT

TEMP.
FIELD
(A) 82.00 X 25.17 / 1000 X 1.17 = 2.42 (a) CORRECTION
Length of MLE Volt Drop/1000ft #4 Temp Correction Volt drop on MLE AIDA 1.23
ARIYANI 1.23
(B) 3400.00 X 13.46 / 1000 X 1.17 = 53.53 (b) CHESY 1.23
Length of Cable Volt Drop/1000ft #1 Temp Correction Volt drop on Cable CINTA 1.24
FARIDA 1.39
(C) 0.00 X 13.46 / 1000 X - = 0.00 (c) GITA 1.25
Length of SSCable Volt Drop/1000ft #1 No Temp Correction Volt drop on SSCable INDRI 1.23
INTAN 1.24
2.42 (a)+ 53.53 (b)+ 0.00 ( c ) + 2220 0 = 2275.94 KAMILA 1.3
Motor Volts Volts @ Transformer KARTINI 1.39
KRISNA 1.29
LITA 1.15
ESTIMATED TRANSFORMER LOSSES = 2.5% X LOADED = 56.90 NORA 1.15
RAMA 1.23
TOTAL VOLTAGE REQUIRED FROM TRANSFORMER =102.5% X LOADED 2332.84 SELATAN 1.17
SUNDARI 1.33
Max Surface KVA @ 60 HZ 257.78 Calculated using NP amps. TITI 1.37
VITA 1.24
WANDA 1.39
Required CT ratio : 100:5 92.8 Required surface voltage 2332.84 Volts WIDURI 1.24
WINDRI 1.24
Required Fuse size : 4R 4.35 YVONNE 1.29
ZELDA 1.39
Complete by : Sarip Hidayat 6-Mar-20 Dated

Requested production rate 4000 BFPD

TO BE COMPLETED BY CNOOC REP :

GIVEN CT RATIO : 100:5 GIVEN VOLTAGE :

CNOOC ENG NAME : SIGNED : :

CNOOC SES Ltd.ESP Runlife Service Package D Contract No.:xxxxxxx


Powerlift Form-A02 Ref No.04/01/2020

Package:
ESP DELIVERY ORDER
D
Customer: PHE OSES Delivery Date: 09/Mar/20
Well Name: CINH-01 1st Installation Powerlift Crew:

Business: SBU Barge Name:


Qty Len.
Item Description Specification Serial No. Case No. Remarks
(ft)
1 POWER PLUG BIW EM52062-129-040 1EA

2 BIW Penetrator: BIW EM51015-1 1EA


3 BIW Downhole Connector: BIW EM53013-R18 1EA

4 Packer

GRAY TBG HGR 3000,13-5/8" x 3-


5 Cable Protectors: Gulf coast for 3 1/2" TBG Tubing 3-1/2 EUE 125 EA 1/2" EUE

6 Splicing Protectors: LONG GULF COAST 1EA


7 Protectorlizer 9 5/8" Casing Liner @ FT 4EA

8 Power Cable: Round Cable 3,500 ESP bottom landed @


9 Flat Cable: MLE flat / New 82 3400feet

10 Discharge Head: 3 1/2 TBG to 130 PUMP 1 EA

11 Pump UT: 130 QN55 ARC 56 STGS 13.48 Anti-corrosion

Pump LT: 130 QN55 ARC 56 STGS 13.48 Anti-corrosion


12

13 Intake 130 NI-AR-CCR-AS-N 2.76 Anti-corrosion

14 Protector DT: 130 NPBPBSLST-AR-CCR-PL3-RF-FD-E-INC 12.2 Anti-corrosion

15 N/A N/A

16 Motor UT: 143 225 HP 2220 V 58 A 23.67 Anti-corrosion


Motor LT: HP V A Anti-corrosion

17 X-Over between motor & Sensor: For 143 MOTOR 1 EA

18 Downhole Monitor: Phoenix 2.43 1 EA


19 Motor shroud n/a For 9 5/8 Casing 0 Liner n/a FT

20 X-over between sensor & Centralizer: 1 EA

21 Entry Guide 9 5/8 for 9 5/8 Casing 0 Liner 1 EA

22 Cable splicing material 1 SET

23 Cable splicing adaptor 1 SET

24 Motor oil 3 barrels


25 Shroud adaptor Pump to Tubing N/A

26 Hex-Head cap socket screw 1 SET

27 Bolt 1 SET
as per the inventory , pls
28 Lead washer 1 SET dispatch proper set to
barge
29 Washer 1 SET

30 White cloth tape 1st installation in new contract 1 SET


please send all new ESP
31 Taflon 1 SET
please send surface equipment sensor
32 O ring 1 SET

33 Sand paper 1 SET

34 Cleaning cloth 1 PACKAGE

Prepared by: Sarip Hidayat Date: 06/Mar/20 Checked By: (Signature)

Approved By: Wang Hui Date: 06/Mar/20 Date:

CNOOC SES.Ltd.ESP Runlife Service Package D Contract No.:xxxxxxx


Powerlift Form-A04 Ref No.04/01/2020

Package:
ESP OPERATION ORDER
D
Customer: PHE OSES Delivery Date: 09/Mar/20

Well Name: CINH-01 Powerlift Crew:

Business: SBU Barge Name: 30/Dec/99

Item Notice During The ESP Operation

Please pay more attention on HSE issues and all employees must wear the PPE. The pre-barge meeting should be held before well workover. Do the pre-check when
1
the equipment arrived at barge as soon as possible.

See the pump design and pump string sheet for more detail. The TP should be not more than 600 psi for QM series & QN120 pump while commissioning.
2
The report should be sent to all related personel including supervisors on barge and field.

3 The last installation is last run reda pump

4 This Well has Packer

Please check cable reading and also visual check the power cable between junction box and powerplug before splicing the powerplug to surface
5
power cable. If it is necessary please change this surface power cable.

Visually inspection of the mechanical to make sure physical is in good condition first. Then electrical property of BIW Power Plug should be taken during rigging down
6 the wellhead. The rig should be in the center of the well before workover and suggest the supervisor adjusting the rig in order that ESP will not scratched during run
into the hole. The cable band can be used during installation as per requirement.

Please visual monitor the cable during POOH and make clear picture for problem part, especially for short runlife & EDHP problem well. Before send the cable to KJ-4,
7
make specification and mark it. If there are some cable left inside of the reel from the last installation, which should be included in the cable specification.

8 The accessory of ESP which is not in good condition should be sent back to Marunda for repair and inform the Marunda to receive it.

9 The pulling and installation report will be sent back to CNOOC office and Jakarta Kelapa Gading office by email and keep the original copy.

In order to extend the run-life of downhole ESP system, all powerlift offshore field operation supervisors(CNOOC NBU) should follow SOP OF SOFT-STARTER if
Transformer with soft starter function is available.The soft starter tap ( Fact-Pac Transformer), is located in the same box( terminal) with main switch, and the
box(terminal) is on side of the Fact-Pac Transformer. The soft starter tap should be pre-set/adjusted as per the below principle. If motor Hp is more than 644hp
10
(including 644hp) and PSD is less than 4000FT, the tap should be pre-set/positioned at tap E (Voltage Drop 1000V),if PSD more than this value, tap should be pre-
set/positioned at tap D (Voltage Drop 750V). For the other motors which drive the 675 series pumps, the tap should all be put at tap D (Voltage Drop 750V), without
consideration of the PSD

Prepared by Sarip Hidayat Approved by Wang Hui

Date: 6-Mar-20 Date 06/Mar/20

CNOOC SES.Ltd.ESP Runlife Service Package B Contract No.:332001579


ESP RUNNING REPORT

WORK
W/H REQUEST NO. AFE NO. NUMBER RIG YEAR
ORDER NO.

ESP SUPPLIER : 18-IA-00155 COSL-222 2017

WELL NAME / JOB : CINH-01 Pump Repair - EDHP DATE OF INSTALL : 11-Jul-2018
INSTALLATION NO. : 3rd Installation DATE OF START-UP : 11-Jul-2018
SETTING DEPTH / TVD : 3,400 FEET TVD : 3680 FEET TEST RATE : BFPD

PERFORATION INTERVAL : 3471-3550 FEET STATIC B.H PRESSURE : PSI

INSTALLED BY - 1. : Luthfierza Rubian INDICATE PHASE SEQUENCE : A B C


2. : Budi Rinaldi START-UP BY - 1. :
3. : Nofrijon 2. :
4. : Sugeng Mulyono

CONDITION EQUIPMENT HP / EQUIPMENT COUPLING


UNIT EQUIPMENT TYPE AMP VOLT BOX NUMBER
N/RC/RR SERIAL NO. STAGES PART NO. P/N.
MOTOR - UT : NEW AHT18D-32343 MOTOR: 562, 7, F073, MAXIMUS, RA-S, C 263 88.1 100373173X 1808
CT1 :
CT2 :
PROTECTOR - UT : 0 0 0 0 0
LT : NEW DFT18F-32538 PROTECTOR: MAXIMUS, BPBSL, 540/540, NT 100391764X 1067636
INTAKE / VGSA : NEW KBT18F-32534 INTAKE: BOI 400/400 RLOY .87 INC 718, 100483770X 100758931
AGH : 0 0 0 0 0
PUMP - UT : NEW 2FS8B8217071 PUMP: RC D4000NX CR-CT 50 STG 400/400 50 101261284 101049669
CT1 : 0 0 0 0 0
CT2 : 0 0 0 0 0
LT : NEW 2FS8B8217121 PUMP: RC D4000NX CR-CT 69 STG 400/400 69 101658478 101049669
DW/HOLE MON. TOOL : NEW S103X18CN05800 BASE GAUGE: XT150 TYPE 0,VITON/AFLAS 100655610X
TOP - JOB NO. : SERIAL NO. TYPE : LENGTH :
PART NO. SERIAL NO. TYPE : LENGTH :
7004302X IOT6D-28495 CABLE: REDACDC, 5K 3800 FT FT FLAT
ROUND CABLE
BOTT - JOB NO. : SERIAL NO. TYPE : LENGTH : CABLE
100714604H5U8A-184155
MLE:562 MAXL 120 FT FT
FT

CONDITION SHIM TOP BOTTOM


EQUIPMENT TYPE / P.N / BRAND / QTY SERIAL NO. OVERALL START UP DATA
N/RC/RR SETTING END END
WELLHEAD RR GRAY TBG HANGER 13 5/8" x 3.5 PUMP-UT TIME WIB
BIW - POWER PLUG NEW EM52062129040_BIN 346 932 PUMP-LT S/ AMP A
BIW - PENETRATOR NEW EM51015-1_BIN 341 404 P/UP TIME Seconds
BIW - CONNECTOR NEW EM53013-R18_BIN 341 559 FINAL RUN AMP A
BOLT ON-HEAD NEW HEAD: BOLT ON DISCHARGE PMP, FLOW T/P PSI
CONDITION TUBING SIZE (QTY) SWITCH GEAR RATE BFPD
EQUIPMENT TYPE / P.N / BRAND / QTY
N/RC/RR 2-7/8" 3-1/2" 4-1/2" TYPE FREQ. (HZ) SBHP PSI
TUBING HANGER RERUN GRAY TBG HANGER 13 5/8" x 3.5 105 EA VOLT FUSE SBHT deg F
TRSV N/A TRSV N/A CT RATIO O.L SET S-Tm deg F
PACKER N/A PACKER N/A COUNTER U.L SET FBHP PSI
SSD RERUN SSD OTIS MOTOR CONTROLLER FBHT deg F
TUBING RERUN production tubing 3.5" (if using) KVA FREQ. (Hz) F-Tm deg F
CHECK VALVE RERUN RCV VSD DATA F-Pd PSI
MOTOR / DMT GUIDE RERUN CENTRALIZER : 2-3/8 EUE Pin W/ ELECTRICAL CHECK RESULTS
ELECTRICAL CHECK SECTIONS
SHROUD 0 0 PHASE to PHASE (OHM) PHASE to GROUND (M-OHM)
SCREEN N/A MOTOR - UT 0.6 0.6 0.6 2000 2000 2000
CBL. PROTECTOR RERUN GULF COAST 3.5" MOTOR - CT1
SPLICE CBL. PROT. RERUN GULF COAST 3.5" - long MOTOR - CT2
MOTOR / DMT ADAPTER N/A D.M TOOL 2000 2000 2000 2000 2000 2000
PROTECTOLIZER - 400s RERUN PTROTECTOLISER 400S PUMP
ROTECTOLIZER - 540/562s RERUN PROTECTOLISER MLE 540S POTH ROUND CABLE 2000 2000 2000 2000 2000 2000
PROTECTOLIZER - 675s - MTR + CBL @ PACK OFF
G-PACK PACKER - CONNECTOR 1.8 1.8 1.8 500 500 500
SLOAN RING -
BULL PLUG - BEFORE SET PACKER 1.8 1.8 1.8 500 500 500
AFTER SET PACKER
VGSA - AGH INCH
PUMP AGH - PUMP LT INCH
SHAFT
SHIMMING PUMP LT-CT INCH PRIOR TO START UP
PUMP CT - UT

REMARKS ( PLEASE WRITE DOWN ANY INFORMATION YOU HAVE RELATED WITH WELL CONDITION, ESP INSTALLATION - RIH & START UP

# ESP setting depth at 3400 FT


# RC D4000NX / 50+69 stgs / BOI 400S / 540S BPBSL MAX / 263 HP MAX - 1808V - 88.1 A / XT150-0 / Centralizer, PSD 3400 FT

# install gulf coast 3.5"


# using VETCO GRAY tubing hanger type, and BIW connector at tubing hanger and wellhead
# no discharge sub, XT150-0

# start up :
# Target Run Life: 1493 days

Anton Maulana / Hibatur


CNOOC Representative
WELL COMPLETION GUIDE
FIELD NAME WELL NAME VERTICAL NEW COMPLETION
KB ### WORKOVER
CINTA H # 01 DIRECTIONAL/ANGLE __⁰ AT ____' MD PUMP REPAIR
18 - 1A - 00155 SIZE WEIGHT GRADE THREAD DEPTH ( FEET )
DV COLLAR SHOE FT
CASING 9-5/8 " 43.5 LBs N.80 BUTT
3632'MD
LINER/ TOP FT SHOE FT
SCREEN
LAST TUBING INSTALATION PBTD FT
TUBING 3-1/2" 9.30 LBs N.80 EUE
3465'MD ( CR )
ZONE / PERFORATION INTERVAL 3422' - 3457' MD
ITEM DESCRIPTION CONDITION O.D.(INCH) I.D.(INCH) LENGTH. FT DEPTH. FT
KB ELEVATION 25.00
1 GRAY TBG HGR 3000,13-5/8" x 3-1/2" EUE RERUN 13.375 3.958 1.00
2 X/O 4-1/2" EUE PIN x 3-1/2" EUE BOX NEW 4.500 2.992 0.35
3 3 JOINTS 3-1/2" TUBING EUE 3% CR RERUN 3.500 2.992 93.17
4 X - NIPPLE NEW 4.500 2.813 1.43 119.52
5 98 JOINTS 3-1/2" TUBING EUE 3% CR RERUN 3.500 2.992 3066.74
6 FLOW COUPLING REDRESS 4.500 2.992 5.80
7 OTIS XO-SSD ( JAR DOWN ) NEW 4.500 2.750 3.62 3193.49
8 2 JOINTS 3-1/2" TUBING EUE 3% CR RECOND 3.500 2.992 62.11
9 FLOW COUPLING NEW 3.500 2.992 5.80
10 RCV SHORT NIPPLE ( EMPTY ) NEW 4.500 2.250 0.82 3265.02
11 2 JOINTS 3-1/2" TUBING EUE 3% CR NEW 3.500 2.992 61.98
12 PUP JOINT 3-1/2" EUE NEW 3.500 2.992 4.00
13 HEAD PUMP NEW 4.625 - 0.58
14 REDA PUMP RC D4000 NX 50 STG NEW 4.000x4.125 - 16.50
15 REDA PUMP RC D4000 NX 69 STG NEW 4.000x4.125 - 21.12
16 INTAKE BO1 400/400 RLOY NEW 4.000 - 1.20
17 REDA ADAPTOR NEW 5.375x3.750 - 0.33
18 REDA PROTECTOR MAXIMUS BPBSL 540/540 NEW 5.125 - 8.95
19 REDA MOTOR MAXIMUS 225 HP/ 1746 V/ 78 A NEW 5.625 - 16.70
20 DOWN HOLE SENSOR XT 150 TYPE 0,VITON/AFLAS,13C NEW 4.500 - 1.85
21 REDA STOPPER NEW 7.500x2.562 - 0.80
BOTTOM REDA PUMP ASSY LANDED AT ------------------------------------------------------- 3399.85

A CONTROL LINE NIPPLE PLUGED


B BIW PENETRATOR NEW
C ROUND CABLE RECOND
D FLAT CABLE NEW
E GULF COAST RERUN
TOTAL ESTIMATE 3400 FT

COMPLETION PROCEDURE :
> KILL WELL AS PER PROGRAM AND CONTINUE N/D X-TREE & N/U BOP.
> POOH REDA PUMP ASSY AND DHE COMPLETION
> R/U SLICKLINE UNIT AND RIH 2.50" IB TO TAG BOTTOM - STOP AT 3458' - POOH
> M/U AND RIH REDA PUMP ASSY AND DHE COMPLETION
> N/D BOP AND N/U TREE
> R/U SLICKLINE UNIT AND RIH JDC POOLING TOOL TO PULL OUT 2.250 RCV (SUCCESS)
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> PACKERLESS <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<

NOTE :
> P/U WEIGHT STRING = 44 KLBS S/O WEIGHT STRING = 44 KLBS
> OTIS XO-SSD 2.750" IS JAR DOWN TO OPEN > 2.250" RCV IS ALREADY RETRIEVED

DRILLING RIG/WORKOVER BARGE APPROVED DRILLING / WORKOVER SUPV. PREPARED BY DATE


COSL 222 BANGUN SITORUS
JULIUS L & YOHANES BP ANTON M & HIBATUR R IBRAHIM MATHIAS H JULY 12.2018
CINTA H-1
PRESENT&PROPOSED COMPLETION JOB/AFE NO.14-IA-00124

DEV. MAX @ PERFS


ANGLE : 0 0
TYPE TOP, ft
KB : WIRELINE 25 +
L-NIPPLE : - 120 + Packerles

CASING GRADEWEIGHT ID DRIFT ID


TUBING : 3-1/2" EUE NPC 9-5/8" N-80 43.5 ppf 8.755" 8.599"

PACKERLESS

PRESENT :
S-SLEEVE : w/ "X"-LN 3,205 +
C-VALVE : 3,271 +
PUMP : SN 8000 79 stgs
INTAKE : ARZ-WOA
PROTECTOR : BPBSL-HL
MOTOR : 3900HP/2375V/73A
SURVEYOR phoenix
BOTTOM, ft : 3,398 +

PROPOSED :
S-SLEEVE : w/ "X"-LN 3,200 +
C-VALVE : 3,260 +
PUMP : SN3600 77 STG
INTAKE : Reda Intake
PROTECTOR : BPBSL-HL TOP, ft BOT, ft SPF ZONE REMARKS
MOTOR : 225HP 1776V 77.3A
SURVEYOR phoenix 35 ft 3,422 3457 4 TAF - A2 Nov-74
BOTTOM, ft : 3,400 +
Last tagged fill@3458' MD 8 ft

Cement Retainer (set:4/78) 3,465 ' MD

3,471 3476 Squeezed off TAF - B1 Apr-78


Cement
3,482 3495 Squeezed off TAF - B2 Apr-78

Cement Retainer (set:2/77) 3,506 ' MD

Cement 38 ft 3,512 3550 Squeezed off TAF 2A2B Feb-77


DEPTH, ft NOTES
PBTD : 3,589 Float Collar
CASING : 3,632 9-5/8"
TD : 3,680 Vertical Well

1-Apr-20 Last Update August 7, 2009, By: MSN


VERTICAL WELL
SOP of Soft-Starter
In order to extend the run-life of downhole ESP system,all powerlift offshore field operation
supervisors(CNOOC NBU) sohuld follow SOP OF SOFT-STARTER as per below SOP of
Soft-Starter if Transformer with soft starter function is available.
1. The soft starter tap (Gact-Pac Transformer), is located in the same box(terminal) with
main
switch, and the box(terminal) is on side of the Fact-Pac Transformer; Please refers to the
below picture.
2. The soft starter tap should be pre-set/adjusted as per the below principle.Please refers
to the
below picture.

* If motor HP is more than 644HP (including 644HP),and PSD is less than 4000 ft.the tap
should be pre-set positioned at tap E(Voltage Drop 1000V);
* If PSD more than this value,tap should be pre-set positioned at tap D(Voltage Drop 750V).
* For the other motors which drive the 675 series pumps,the tap should all be put at tap
D(Voltage Drop 750V),without consideration of the PSD.
3. Prior to fixing the soft-start tap by bolt,the tap should be moved back and forth for good
contacting.
4. After the tap is setup, the SCR(Sensing current relay) should be adjusted in order that
the
"Bypass contactor" can work properly.
* Calculating "the Bypass current",multiply the motor nameplate amp rating by 1.6
EXAMPLE: 103Amper motor 100x1.6=164.8 A
*Calculating the CT ratio,divide the primary current by the secondary current rating.
EXAMPLE: 200 to 5 CT has a ratio of 40.(200/5)
* Calculating the SC relay setting,divide the "Bypass Current" by the CT ratio.
EXAMPLE: 1648 A /40 (CT ratio) =4.12 amps
The SC relay setting in the example is 4.12 amps.
* Set the SC repay to 4.12 A by adjusting the knurled nut to position 4.12 approximately on
the vertical shaft.

5. Before started up, some settings should be done in K095. Access to the main menu.
please move the cursor to "set up" and enter, then choose the "equipment" and erter.
Set up by adjusting the "Lamp Function" "YELLOW= Reactor" in order to active the time
relay.

Remark:

1. After the soft-starter has been set up,maybe there is an aborted start due to the
additional voltage drop on the power system.Resetting the Soft-Starter to a lower tap
setting is necessary /needed.
2. After the Soft-Starter has been set up,maybe there is an alarm indication with "under
voltage.Normally it would be deanedlater automatically.
3. Sometimes SCR is not connected or not available, in this situation SCR adjustment is
not necessary.

Caution:never attempt to change the tap after the TR is energized/running.


If you have some don't understand Please contact Jakart office .