Professional Documents
Culture Documents
Product Catalogue
Product Catalogue
“Our Goal”
One of the most enduring of all the ancient laws of humanity is
that we see the world not as it is, but as we are. By improving,
refining and defining who we are, we see the world from the highest
clearest perspective.
GLASS TUBE ROTAMETER
TECHNICAL SPECIFICATION
REPEATABILITY : +/- 0.25 % OF FSR
RANGEABILITY : 10 : 1
TEMPERATURE RATING : 150 deg C
20000
PRESSURE RATING : 10 Kg/cm2
18000
16000
BODY : M S POWDER COATED
14000
END CONNECTION : FLANGED / SCREWED
12000
10000
AS PER CUSTOMER
8000
SPECIFICATION.
6000
4000
MATERIAL OF : C S/ SS 304/ SS 316/
2000 WETTED PART : PP/ PVC/ TEFLON
METERING TUBE : BOROSILICATE GLASS
FLOAT : SS 304/ SS316
AS PER TYPE OF FLUID
FLOW DIRECTION : FROM BOTTOM TO TOP
MOUNTING POSITION VERTICAL
ELASTOMERS : NEOPRENE / SILICON /
VITON / PTFE.
FLANGED SCREWED
Purge Rotameter
MODEL CODE
SC -
L LIQUID SERVICE
G GAS SERVICE
1 114 mm
2 224 mm
O WITHOUT VALVE
V WITH VALVE
A ACTUAL SCALE
P PERCENTAGE SCALE
0002
2
½’’ 0003
3
0004
4
0005
5
0006
6
0007
7
s (WETTED PARTS)
304
316
PP
PVC
304PTFE
316PTFE
I AL
I SP
FOR FLOAT
2
3
J
VAC IN
VAC INC
R-300/D/ 001/ 304/ AL/ 01/ JIN
ORI FLOW METER
THE ORI-FLOW METER MEASURES FLOW BY INSERTING AN ORIFICE AT PART OF THE
PIPING, GENERATING DIFFERENTIAL PRESSURE BEFORE AND BEHIND THE ORIFICE
BY MEANS OF THE FLOW, AND EXTRACTING THIS DIFFERENTIAL PRESSURE BY A
SUITABLE METHOD.
DIFFERENTIAL PRESSURE (P1-P2) OF MAIN ORIFICE AND THE FLOW Q HAVE SHOWN
IN EQUATION GIVEN BELOW. THE FLOW IS PROPORTIONAL TO THE SQUARE ROOT
OF THE DIFFERENTIAL PRESSURE.
—
Q= CF
Q :
√ 2g (P -P )
-
1
Volumetric flow
2
C : Flow co-efficient
F : Cross sectional area of orifice hole
g : Acceleration of gravity
P1-P2 : Differential pressure
? : Specific weight of fluid
THE ORIFICE PLATES ARE DESIGNED AS PER Bs 1042-1981 / ISO 5167 & L K. SPINK
STANDARDS. WHEN A DEVICE SUCH AS AN ORIFICE PLATE IN A PIPE LINE THROUGH
WHICH A FLUID IS FLOWING, AS STATIC PRESSURE DIFFERENCE EXISTS BETWEEN
THE UPSTREAM SIDE & THE DOWNSTREAM SIDE OF THE DEVICE IS GEOMETRICALLY
SIMILAR TO ONE ON WHICH DIRECT CALIBRATION HAS BEEN MADE, THE CONDITIONS
OF USE BEING THE SAME, THE RATE OF FLOW MAY BE DETERMINED FROM A KNOWLE-
DGE OF THE CIRCUMSTANCE UNDER WHICH THE DEVICE IS BEING USED.
TECHNICAL SPECIFICATION
ORIFICE PLATE : SS 316/ SS 304/ MONEL
NUTS : ASTM-A-193 GR 2H
PROPERTIES OF CAPACITOR.
TECHNICAL SPECIFICATION
SUPPLY VOLTAGE : 12 TO 24 V DC
RESULUTION : 0.1
ACCURACY :
-+ 0.25 % FSR
TECHNICAL SPECIFICATION
:
MEASURING RANGE FROM 65MM AND ABOVE
:
TRANSMITTER TYPE LOOP POWERED
:
SUPPLY VOLTAGE 12 TO 24 V DC
:
OUT PUT 4-20mA @ CONSTANT CURRENT
LOAD OF 500 Ω
RS-485O(OPTIONAL)
:
TEMPERATURE -20 TO 100 C
:
ENCLOSURE ABS, DULY APPROVED FOR IP 65 / 67
: WITH MOUNTING PLATE
RESULUTION 0.1
ULTRASONIC LEVEL TRANSMITTER
TECHNICAL SPECIFICATION
SOME APPLICATIONS
CHEMICAL PROCESS : ACIDS, BASES,BULKY POWDER,ORES.
PETROCHEMICALS : MOST HYDROCARBONS
FOOD & BEVERAGE : JUICE,BEER, SLURRIES,GRAINS
WATER & WASTEWATER : TANKS,OPEN CHANNEL FLOW
PHARMACEUTICALS : POWDER, LIQUIDS, PASTE.
PAPER & PULP : LIQUERS, BLEACHING AGENTS.
PLASTICS : GRANULES,POWDER SOLVENTS.
Tubular Level Gauge
Simple low cost and reliable for direct reading of clean
liquid levels at low pressure & temperature conditions.
Features :
360° visibility with tie-rod guards.
Glass removal / replacement possible w/o dismantling of gauge.
Offset isolating valves permit cleaning of glass gauge w/o removal.
Auto Ball Check :
Autoball check facility is provided to prevent "liquid
loss" from vessel during breakage of gauge glass. Inner race Neck
It consists of a capsule located within the gauge
'neck' and contains a ' ball ' which moves freely
along its inner race between the stopper & orifice.
During breakage, the pressure on 'ball' from gauge
side will be atmospheric, whereas higher pressure
from vessel side ("op.pr + liquid column") will Stopper
cause the ball to move and block the orifice, to Ball
minimize liquid loss
Vent Plug
Gauge
CC. dist.
(mm)
Installation :
Guard
Side mounted through tank nozzles, having
matching counter flanges / threads, ensuring
that CC distance between nozzles corresponds
with CC distance (R) of the gauge.
TANK Isolating
Valve
Schematic diagram
Vent Plug
Process
Applications : Chemical / Petro-Chemical, Fertilizer, Power End Block Connection
generation, Pharmaceutical, Automobile, Water/Waste Water/
Effluent treatment plants, Cooling/Lubricating/Filtration systems, Gland
Liquid sewerage tanks, Chemical dosing system, Chemical Tightening Bolt
reactors etc. Guard
Cal. Scale
V CC. dist.
(mm)
Gauge
Gland
Guard Holder
Packing
Adapter 100
Drain Valve Approx.
95 85
(max.) (max.)
25
SC/MLI/501:FOLLOWER TYPE INDICATOR
20 SC/MLI/502:BI-COLORED ROTATING TYPE INDICATOR
15
OPERATING PRESSURE/TEMPERATURE:30 kg/cm2 /2000C.
10
5
MOUNTING : SIDE /TOP.
0 ADDITIONAL ACCESSORIES:
*ADJUSTING ALARM SWITCH.
*RELAY CONTROL UNIT.
ELECTROMAGNETIC
FLOW METER
R-401
Main Features:
Range of diameter 15 to 300 mm
Compact and remote version with protection IP65
Mounting of electronic unit in two directions
Power supply voltage 95 to 250VAC or 24VAC/DC,
50/60Hz
Dosing feature with several type of digital/analogue
outputs
Pipe dimensions
Inner size DN [mm] Length L [mm]
15 - 80 200
100 - 150 250
200 300
250 350
300 400
Application:
Water and Wastewater Measurement
Chemical industry (acids, alkaline solutions)
Spink Magnetic Flowmeter-R-401is an instrument designed for measuring and indicating flow and total
Magnetic Flowmeter-R-401
volume of conductive liquids. As there are no moving parts in the flow profile the device can be used to
measure extremely dirty liquids containing solids. The flowmeter is for use with conductive liquids only.
Range of applications. The inductive flowmeter R-401 has been designed for use in all process industries
including chemical, water and wastewater.
Features. The inductive flowmeter R-401 is a highly accurate and stable device. The construction of the
R-401 indicator uses components with a long-term time and temperature stability.
Technical data
Nominal size Dn15 to DN300
Nominal pressure Pn15 to PN25 (depending on diameter)
Flow range 0.1 to 10 m/s (0.02 to 5000 l/s)
Accuracy 0.5% (0.5 to 10 m/s) of reading value
Electromagnetic
1% (0.1 to 0.5 m/s) of reading value
Maximum medium temperature 70°C for rubber liner
130°C for PTFE liner
Ambient temperature -20 to 70 °C
Power supply • 115/230V AC (+10%, -15%)
• 24V DC/50/60Hz as option
Power consumption 10 VA
Liner • hard rubber
• PTFE
Flow
Electrodes • Hastelloy C276/553/6/Pt/ta/Ti
®
SPINK C O N T R O L S
T
N
O
LIST OF PRODUCT
C
FLOW:
K
SR NO ITEM
IN
1 Glass tube Rotameter
2 Metal tube rotameter
SP
Page 1 of 1
Add: R. No.1 A, Vilas Apartment, Sant Tukaram Path, Kopri, Thane (E) – 400603.
Ph. No.: +91 22 2532 8223 / 24. Email: info@spinkcontrolsindia.com. Website: www.spinkcontrolsindia.com
T
N
O
C
K
PRESSURE:
IN
SR NO ITEM
1 Pressure Gauges
SP
2 Pressure Transmitter
3 Pressure Switches
Page 2 of 1
Add: R. No.1 A, Vilas Apartment, Sant Tukaram Path, Kopri, Thane (E) – 400603.
Ph. No.: +91 22 2532 8223 / 24. Email: info@spinkcontrolsindia.com. Website: www.spinkcontrolsindia.com
T
N
O
C
LEVEL:
K
Sr. No. Item
IN
1 Tubular level gauge
2 Reflex level gauge
SP
Page 3 of 1
Add: R. No.1 A, Vilas Apartment, Sant Tukaram Path, Kopri, Thane (E) – 400603.
Ph. No.: +91 22 2532 8223 / 24. Email: info@spinkcontrolsindia.com. Website: www.spinkcontrolsindia.com