Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 116

RZ POWER LIMITED

(50 MW HSD RPP)


Thakurgaon Road, Thakurgaon

Engine Status
G/N 30/11
1G-1 23:16 8:12 22:38 2G-1
1G-2 23:16 8:12 22:38 2G-2
1G-3 23:16 8:12 22:38 2G-3
1G-4 23:16 8:12 22:38 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 23:16 8:12 22:38 2G-6
1G-7 23:16 8:12 20:30 2G-7
1G-8 23:16 8:12 22:38 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 23:16 8:12 22:38 2G-10
1G-11 23:16 8:12 8:15 Water leakage from oil cooler 2G-11
1G-12 23:16 8:12 22:38 2G-12
1G-13 23:16 8:12 22:38 2G-13
1G-14 23:16 8:12 22:38 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 23:16 8:30 22:38 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 2G-19
1G-20 Tx-07(4.5MVA) are in maintenance condition 2G-20
1G-21

Engines View
Engine Running Gensets Load Sta
Buiding
nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=
Engine out of order
ER LIMITED Date: 01.12.10
W HSD RPP)
Road, Thakurgaon

ine Status
30/11
Excitor Rotor cable has been damaged
23:16 8:12 22:38
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
23:16 8:12 17:53 18:10 22:38
18:20 8:12 17:53 18:10 22:38
23:16 8:12 22:38
22:43 Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
23:16 8:12 22:38
23:16 8:12 22:38
23:16 8:12 22:38
Security NUT-BOLTs removed from exhaust manifold
23:16 8:12 21:22 Lube oil was mixed with Coolant water
Rapid load fluctuation
23:16 8:12 22:38
23:16 8:12 22:38
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
11 1000 89.93 11 A-Shift Md. Anisur Rahman
9 1380 89.15 12.42
20 23.42 B-Shift Asaduzzaman

C-Shift Md.Hasanuzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 22:38 16:50 23:20 2G-1
1G-2 22:38 16:50 23:20 2G-2
1G-3 22:38 16:50 23:20 2G-3
1G-4 22:38 16:50 23:20 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 22:38 16:50 23:20 2G-6
1G-7 20:30 16:50 23:20 2G-7
1G-8 22:38 16:50 23:20 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 22:38 16:50 23:20 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 22:38 16:50 23:20 2G-12
1G-13 22:38 16:50 23:20 2G-13
1G-14 22:38 16:50 23:20 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 22:38 16:50 23:20 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 2G-19
1G-20 Tx-07(4.5MVA) are in maintenance condition 2G-20
1G-21

Engines View
Engine Running Gensets Load Sta
Buiding
nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=
Engine out of order
ER LIMITED Date: 02.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


22:38 16:50 23:20
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
22:38 16:50 23:20
22:38 16:50 19:47 20:55 23:20
22:38 16:50 16:52 17:05 23:20
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
22:38 16:50 23:20
22:38 16:50 23:20
22:38 16:50 23:20
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
22:38 16:50 23:20
22:38 16:50 23:20
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Asaduzzaman
9 1400 90.44 12.6
21 24.6 B-Shift Md.Hasanuzzaman

C-Shift Md.Moniruzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 15:15 2G-1
1G-2 15:15 2G-2
1G-3 15:15 2G-3
1G-4 15:15 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 15:15 2G-6
1G-7 15:15 2G-7
1G-8 17:16 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 15:15 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 15:15 2G-12
1G-13 15:15 2G-13
1G-14 15:15 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 15:15 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 15:15 2G-19
1G-20 15:15 2G-20
1G-21 15:15 17:16 18:55

Engines View
Engine Running Gensets Load Sta
Buidin
g nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=

Engine out of order


ER LIMITED Date: 04.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


15:15
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
15:15 18:50
15:15
15:15
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
15:15
15:15
15:15
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
15:15
15:15
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
15 1000 89.93 15 A-Shift Shahriar kabir
8 1400 90.44 11.2
23 26.2 B-Shift Md.Hasanuzzaman

C-Shift Md.Moniruzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 8:52 13:01 16:48 22:59 2G-1
1G-2 8:52 13:01 16:48 22:59 2G-2
1G-3 8:52 13:01 16:48 22:59 2G-3
1G-4 8:52 13:01 16:48 22:59 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 8:52 13:01 16:48 22:59 2G-6
1G-7 8:52 13:01 16:48 19:00 Fire introduced in ALT 2G-7
1G-8 8:52 13:01 16:48 22:59 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 8:52 13:01 16:48 22:59 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 8:52 13:01 16:48 22:59 2G-12
1G-13 8:52 13:01 16:48 22:59 2G-13
1G-14 8:52 13:01 16:48 22:59 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 8:52 13:01 16:48 22:59 2G-19
1G-20 8:52 13:01 16:48 22:59 2G-20
1G-21 8:52 13:01 16:48 22:59

Engines View
Engine Running Gensets Load
Buiding
nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=

Engine out of order


ER LIMITED Date: 05.12.10
W HSD RPP)
Road, Thakurgaon

ne Status

Excitor Rotor cable has been damaged


8:52 13:01 16:48 22:59
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
8:52 13:01 16:48 22:59
8:52 13:01 16:48 22:59
8:52 13:01 16:48 22:59
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
8:52 13:01 16:48 22:59
8:52 13:01 16:48 22:59
8:52 13:01 16:48 22:59
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
8:52 13:01 16:48 22:59
8:52 13:01 16:48 22:59
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
14 1000 89.93 14 A-Shift Md.Hasanuzzaman
9 1400 90.44 12.6
23 26.6 B-Shift Md.Moniruzzaman

C-Shift Md. Rubayet Imteaz


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 10:55 13:13 16:45 2G-1
1G-2 10:55 13:13 16:45 20:18 2G-2
1G-3 10:55 13:13 16:45 2G-3
1G-4 10:55 13:13 16:45 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 10:55 13:13 16:45 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 10:55 13:13 16:45 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 10:55 13:13 16:45 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 10:55 13:13 16:45 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 10:55 13:13 16:45 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 10:55 13:13 16:55 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 8:52 13:13 16:45 2G-19
1G-20 10:55 13:13 16:45 2G-20
1G-21 10:55 13:13 16:45

Engines View
Engine Running Gensets Load St
Buiding
nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=

Engine out of order


ER LIMITED Date: 06.12.10
W HSD RPP)
Road, Thakurgaon

ne Status

Excitor Rotor cable has been damaged


10:55 13:13 16:45
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
10:55 13:13 16:45
10:55 13:13 16:45
10:55 13:13 16:45
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
10:55 13:13 16:45
10:55 13:13 16:45
10:55 13:13 16:45
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
10:55 13:13 16:45
10:55 13:13 16:45
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Md.Moniruzzaman
9 1400 90.44 12.6
21 24.6 B-Shift Md. Rubayet Imteaz

C-Shift Shahriar kabir


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 9:20 13:02 16:45 23:06 2G-1 Excitor Rotor cable has been da
1G-2 9:20 13:02 16:45 23:06 2G-2 9:20 13:02 16:45 23:06
1G-3 9:20 13:02 16:45 23:06 2G-3 Lube oil was mixed with Coolan
1G-4 9:20 13:02 16:45 23:06 2G-4 Fire introduce in turbo lube oi
1G-5 Fire introduced in ALT 2G-5 9:20 13:02 16:45 23:06
1G-6 9:20 13:02 16:45 23:06 2G-6 9:20 13:02 16:45 23:06
1G-7 Fire introduced in ALT 2G-7 9:20 13:02 16:45 23:06
1G-8 9:20 13:02 16:45 23:06 2G-8 Water leakage from oil coo
1G-9 Fire introduced in ALT 2G-9 Lube Oil leakage from Turbo oil re
1G-10 9:20 13:02 16:45 23:06 2G-10 Lube oil was mixed with Coolan
1G-11 Water leakage from oil cooler 2G-11 Lube oil was mixed with Coolan
1G-12 9:20 13:02 16:45 23:06 2G-12 9:20 13:02 16:45 23:06
1G-13 Fire introduced in ALT 2G-13 9:20 13:02 16:45 23:06
1G-14 9:20 13:02 16:45 23:06 2G-14 9:20 13:02 16:45 23:06
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15 Security NUT-BOLTs removed from ex
1G-16 Fire introduced in ALT 2G-16 Lube oil was mixed with Coolan
1G-17 9:20 13:02 16:45 23:06 2G-17 Rapid load fluctuation
1G-18 Grease leakage from NON drive end of ALT 2G-18 9:20 13:02 16:45 23:06
1G-19 9:20 13:02 16:45 23:06 2G-19 9:20 13:02 16:45 23:06
1G-20 9:20 13:02 16:45 23:06 2G-20 Excessisive vibration
1G-21 9:20 13:02 16:45 23:06

Engines View
Engine Running Gensets Load Status
Total
Running Load
Buiding Set Load % load of
Gensets (MW)
nos. (KW) engines
no.
Engine S/D B-01 13 1000 89.93 13
B-02 9 1400 90.44 12.6
Engine under maintenance Total 25.6
22
=

Engine out of order


Date: 07.12.10

Excitor Rotor cable has been damaged

Lube oil was mixed with Coolant water


Fire introduce in turbo lube oil line

Water leakage from oil cooler


Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water

rity NUT-BOLTs removed from exhaust manifold


Lube oil was mixed with Coolant water
Rapid load fluctuation

Excessisive vibration

Shift In-Charge

A-Shift Md.Moniruzzaman

B-Shift Md. Rubayet Imteaz

C-Shift Shahriar kabir


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 11:05 13:36 16:40 22:46 2G-1
1G-2 9:45 13:36 16:40 22:46 2G-2
1G-3 9:45 13:36 16:40 22:46 2G-3
1G-4 9:45 13:36 16:40 19:06 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 9:45 13:36 16:40 22:46 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 9:45 13:36 16:40 22:46 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 9:45 13:36 16:40 22:46 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 9:45 13:36 16:40 22:46 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 9:45 11:07 13:19 13:36 16:40 22:46 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 9:45 13:36 16:40 22:46 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 9:45 13:36 16:40 22:46 2G-19
1G-20 9:45 13:36 16:40 22:46 2G-20
1G-21 9:45 13:36 16:40 22:46

Engines View
Engine Running Gensets Load
Buiding
nos.

Engine S/D B-01


B-02
Engine under maintenance Total
=

Engine out of order


ER LIMITED Date: 08.12.10
W HSD RPP)
Road, Thakurgaon

ne Status

Excitor Rotor cable has been damaged


9:45 13:36 16:40 22:46
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
9:45 13:36 16:40 22:46
9:45 13:36 16:40 22:46
9:45 13:36 16:40 22:46
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
9:45 13:36 16:40 22:46
9:45 13:36 16:40 22:46
9:45 13:36 16:40 22:46
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
9:45 13:36 16:40 22:46
9:45 13:36 16:40 22:46
Excessisive vibration

Gensets Load Status Shift In-Charge


Total
Running Load
Set Load % load of
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Asaduzzaman
9 1400 90.44 12.6
21 24.6 B-Shift Shahriar kabir

C-Shift Md.Hasanuzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 14:45 22:57 2G-1
1G-2 14:45 22:57 2G-2
1G-3 14:45 22:57 2G-3
1G-4 14:45 22:57 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 14:45 14:55 Water leakage from radiator 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 14:45 22:57 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 14:45 22:57 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 14:45 22:57 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 14:45 22:57 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 14:45 14:55 16:40 22:57 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 14:45 22:57 2G-19
1G-20 14:45 22:57 2G-20
1G-21 14:45 22:57

Engines View

Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 09.12.10
W HSD RPP)
Road, Thakurgaon

ne Status

Shift In-Charge
Excitor Rotor cable has been damaged
14:45 14:55 16:40 22:57 A-Shift
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line B-Shift
14:45 14:55 16:40 22:57
14:45 14:55 16:40 22:57 C-Shift
14:45 14:55 16:40 22:57
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
14:45 14:55 16:40 22:57
14:45 14:55 16:40 22:57
14:45 14:55 16:40 22:57
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
14:45 14:55 16:40 22:57
14:45 14:55 16:40 22:57
Excessisive vibration

Gensets Load Status


Running % load
Buiding Set Load
Gensets of
nos. (KW)
no. engines
B-01 12 1000 89.93
B-02 9 1400 90.44
Total = 21
Shift In-Charge

Asaduzzaman

Shahriar kabir

Md.Hasanuzzaman

Total
Load (MW)

12
12.6
24.6
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 16:48 23:25 2G-1
1G-2 16:48 23:25 2G-2
1G-3 16:48 23:25 2G-3
1G-4 16:48 23:25 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 Water leakage from radiator 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 16:48 23:25 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 16:48 23:25 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 16:48 23:25 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 16:48 23:25 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 16:48 23:25 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 16:48 23:25 2G-19
1G-20 16:48 23:25 2G-20
1G-21 16:48 23:25

Engines View

Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 10.12.10
W HSD RPP)
Road, Thakurgaon

ne Status

Shift In-Charge
Excitor Rotor cable has been damaged
16:48 23:25 A-Shift
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line B-Shift
16:48 23:25
16:48 23:25 C-Shift
16:48 23:25
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
16:48 23:25
16:48 23:25
16:48 23:25
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
16:48 23:25
16:48 23:25
Excessisive vibration

Gensets Load Status


Running % load
Buiding Set Load
Gensets of
nos. (KW)
no. engines
B-01 12 1000 89.93
B-02 9 1400 90.44
Total = 21
Shift In-Charge

Shahriar kabir

Md.Hasanuzzaman

Md.Moniruzzaman

Total
Load (MW)

12
12.6
24.6
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 11:20 2G-1
1G-2 11:20 2G-2
1G-3 12:40 2G-3
1G-4 11:20 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 Water leakage from radiator 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 11:20 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 11:20 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 11:20 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 11:20 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 11:20 13:55 Fire introduced in ALT 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 11:20 2G-19
1G-20 11:20 2G-20
1G-21 11:20

Engines View Gensets Load


Buiding
Engine Running nos.

B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 11.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


11:20
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
11:20
11:20
11:20
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
11:20
11:20
11:20
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
11:20
11:20
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
11 1000 89.93 11 A-Shift Shahriar kabir
9 1400 90.44 12.6
20 23.6 B-Shift Md.Hasanuzzaman

C-Shift Md.Moniruzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 9:40 13:06 16:28 23:18 2G-1
1G-2 9:52 13:06 16:28 23:18 2G-2
1G-3 9:40 13:06 16:28 23:18 2G-3
1G-4 9:52 13:06 16:28 23:18 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 16:28 23:18 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 9:40 13:06 16:28 23:18 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 9:40 13:06 16:28 23:18 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 9:40 13:06 16:28 23:18 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 9:40 13:06 16:28 23:18 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 10:20 13:06 16:28 23:18 2G-19
1G-20 10:20 13:06 16:28 23:18 2G-20
1G-21 10:20 13:06 16:28 23:18

Engines View Gensets Load


Buiding
Engine Running nos.

B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 12.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


9:40 13:06 16:28 23:18
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
9:40 13:06 16:28 23:18
Lube oil was mixed with Coolant water
9:40 13:06 16:28 23:18
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
9:40 13:06 16:28 23:18
9:40 13:06 16:28 23:18
9:40 13:06 16:28 23:18
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
9:40 13:06 16:28 23:18
9:40 13:06 16:28 23:18
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Md.Hasanuzzaman
8 1400 90.44 11.2
20 23.2 B-Shift Md.Moniruzzaman

C-Shift Md. Anisur Rahman


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 14:40 22:34 2G-1
1G-2 14:40 22:34 2G-2
1G-3 14:40 22:34 2G-3
1G-4 14:40 22:34 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 14:40 22:34 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 14:40 22:34 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 14:40 22:34 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 14:40 22:34 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 14:40 15:20 16:10 22:34 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 15:20 22:34 2G-19
1G-20 15:20 22:34 2G-20
1G-21 16:10 22:34

Engines View Gensets Load


Buiding
Engine Running nos.

B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 13.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


14:40 22:34
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
14:40 22:34
Lube oil was mixed with Coolant water
14:40 22:34
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
14:40 22:34
14:40 22:34
14:40 22:34
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
14:40 22:34
14:40 22:34
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Md.Hasanuzzaman
8 1400 90.44 11.2
20 23.2 B-Shift Md.Moniruzzaman

C-Shift Shahriar kabir


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 12:50 2G-1
1G-2 12:50 2G-2
1G-3 12:50 2G-3
1G-4 13:55 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 13:55 21:00 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 12:50 14:20 15:20 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 12:50 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 12:50 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 12:50 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
1G-18 Grease leakage from NON drive end of ALT 2G-18
1G-19 12:50 2G-19
1G-20 12:50 2G-20
1G-21 12:50

Engines View Gensets Load


Buiding
Engine Running nos.

B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 14.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


12:50
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
12:50
Lube oil was mixed with Coolant water
12:50
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
12:50
12:50
12:50
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
12:50
12:50
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
12 1000 89.93 12 A-Shift Md.Moniruzzaman
8 1400 90.44 11.2
20 23.2 B-Shift Md. Anisur Rahman

C-Shift Shahriar kabir


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 16:27 2G-1
1G-2 16:27 2G-2
1G-3 16:27 2G-3
1G-4 16:27 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 16:27 20:30 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 16:27 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 16:27 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 16:27 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 16:27 2G-14
1G-15 Actuator haunting problem+ Grease leaking from NON drive end of ALT 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
r5 Grease leakage from NON drive end of ALT 2G-18
1G-19 16:27 22:10 2G-19
1G-20 16:27 2G-20
1G-21 16:27

Engines View Gensets Load


Buiding
Engine Running nos.

B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 15.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


16:27
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
Water leakage from radiator

16:27
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
16:27
Lube oil was mixed with Coolant water
16:27
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
16:27 16:30 Water leakage from radiator
16:27
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
14 1000 89.93 14 A-Shift Md.Moniruzzaman
7 1400 90.44 9.8
21 23.8 B-Shift Md. Anisur Rahman

C-Shift Shahriar kabir


RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon

Engine Status
G/N G/N
1G-1 16:55 21:40 2G-1
1G-2 16:55 21:40 2G-2
1G-3 16:55 21:40 2G-3
1G-4 16:55 21:40 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 16:55 21:40 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 16:55 21:40 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 16:55 21:40 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 16:55 21:40 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 16:55 2G-14
1G-15 16:55 17:50 18:30 21:40 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
1G-18 17:15 21:40 2G-18
1G-19 16:55 21:40 2G-19
1G-20 16:55 21:40 2G-20
1G-21 16:55 21:40

Engines View Gensets Load


Buiding
Engine Running nos.
B-01
Engine S/D B-02
Total

Engine under maintenance

Engine out of order


ER LIMITED Date: 16.12.10
W HSD RPP)
Road, Thakurgaon

ine Status

Excitor Rotor cable has been damaged


16:55 21:40
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line
16:55 21:40
Lube oil was mixed with Coolant water
16:55 21:40
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
16:55 21:40
Lube oil was mixed with Coolant water
16:55 21:40
Security NUT-BOLTs removed from exhaust manifold
Lube oil was mixed with Coolant water
Rapid load fluctuation
16:55 21:40
16:55 21:40
Excessisive vibration

Gensets Load Status Total Shift In-Charge


Running
Set Load % load of
Load
Gensets (MW)
(KW) engines
no.
14 1000 89.93 14 A-Shift Md. Anisur Rahman
7 1400 90.44 9.8
21 23.8 B-Shift Shahriar kabir

C-Shift Md.Hasanuzzaman
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 17:10 21:35 2G-1
1G-2 17:10 21:35 2G-2
1G-3 17:10 21:35 2G-3
1G-4 17:10 21:35 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 17:10 21:35 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 17:10 21:35 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 17:10 21:35 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 17:10 21:35 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 17:10 21:35 2G-14
1G-15 17:10 21:35 2G-15

1G-16 Fire introduced in ALT 2G-16


1G-17 Fire introduced in ALT 2G-17
1G-18 17:10 21:35 2G-18
1G-19 17:10 21:35 2G-19
1G-20 17:10 21:35 2G-20
1G-21 17:10 21:35
WER LIMITED Date: 17.12.10
MW HSD RPP)
on Road, Thakurgaon
Engine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
Excitor Rotor cable has been damaged
17:10 21:35 B-Shift
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift
17:10 21:35
Lube oil was mixed with Coolant water Engines View
17:10 17:15 Water leakage from radiator
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
17:10 21:35
Lube oil was mixed with Coolant water
17:10 21:35
Security NUT-BOLTs removed from exhaust manifold Gensets Load Statu
Buiding
Lube oil was mixed with Coolant water nos.
Rapid load fluctuation B-01
17:10 21:35 B-02
17:10 21:35 Total
Excessisive vibration
Shift In-Charge
Md. Anisur Rahman

Shahriar kabir

Md.Hassanuzzaman

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Running Set Load % load of
generatio
Gensets (KW) engines n (MW)
14 1000 89.93 14
6 1400 90.44 8.4
20 22.4
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 16:47 22:06 2G-1
1G-2 16:47 2G-2
1G-3 16:47 2G-3
1G-4 16:47 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 16:47 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 16:47 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 16:47 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 16:47 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 16:47 2G-14
1G-15 16:47 2G-15

1G-16 Fire introduced in ALT 2G-16


1G-17 Fire introduced in ALT 2G-17
1G-18 16:47 2G-18
1G-19 16:47 2G-19
1G-20 16:47 2G-20
1G-21 16:47
WER LIMITED Date: 19.12.10
MW HSD RPP)
n Road, Thakurgaon
ngine Status Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
Excitor Rotor cable has been damaged
16:47 16:51 18:10 B-Shift
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift
16:47
Lube oil was mixed with Coolant water Engines View
Water leakage from radiator
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
16:47
Lube oil was mixed with Coolant water
16:47
Security NUT-BOLTs removed from exhaust manifold Gensets Load Statu
Buiding
Lube oil was mixed with Coolant water nos.
Rapid load fluctuation B-01
16:47 B-02
16:47 Total
Excessisive vibration
Shift In-Charge

Shahriar kabir

Md.Hassanuzzaman

Md.Moniruzzaman

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Running Set Load % load of
generation
Gensets (KW) engines (MW)
14 1000 89.93 14
5 1400 90.44 7
19 21
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N A Shift ( 7:00 - 14:00
1G-1 17:11 2G-1 E
1G-2 17:11 2G-2
1G-3 17:11 2G-3 L
1G-4 17:11 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 17:11 2G-6 L
1G-7 Fire introduced in ALT 2G-7
1G-8 17:11 2G-8
1G-9 Fire introduced in ALT 2G-9 Lu
1G-10 17:11 2G-10 L
1G-11 Water leakage from oil cooler 2G-11 L
1G-12 17:11 2G-12
1G-13 Fire introduced in ALT 2G-13 L
1G-14 17:11 2G-14
1G-15 17:11 2G-15 Security

1G-16 Fire introduced in ALT 2G-16 L


1G-17 Fire introduced in ALT 2G-17 Rapid load fluctu
1G-18 17:11 2G-18
1G-19 17:11 2G-19
1G-20 17:11 2G-20
1G-21 17:11
IMITED Date: 19.12.10
RPP)
hakurgaon
tus Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Shahriar kabir
Excitor Rotor cable has been damaged
17:11 B-Shift Md.Hassanuzzaman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift Md.Moniruzzaman
17:11
Lube oil was mixed with Coolant water Engines View
17:11 Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water Engine under maintenance
17:11
Lube oil was mixed with Coolant water Engine out of order
17:11
Security NUT-BOLTs removed from exhaust manifold Gensets Load Status
Buiding Running Set Load
Lube oil was mixed with Coolant water nos. Gensets (KW)
Rapid load fluctuation 19:25 B-01 14 1000
17:11 B-02 8 1400
17:11 Total 22
Excessisive vibration
In-Charge

ar kabir

ssanuzzaman

niruzzaman

View

e under maintenance

e out of order

Load Status Total


% load of generatio
engines n (MW)
89.93 14
90.44 11.2
25.2
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 16:20 22:18 2G-1
1G-2 16:20 22:18 2G-2
1G-3 16:20 22:18 2G-3
1G-4 16:20 22:18 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 16:20 22:18 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 16:20 22:18 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 16:20 22:18 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 16:20 22:18 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 16:20 22:18 2G-14
1G-15 16:20 22:18 2G-15

1G-16 Fire introduced in ALT 2G-16


1G-17 Fire introduced in ALT 2G-17
1G-18 16:20 22:18 2G-18
1G-19 16:20 22:18 2G-19
1G-20 16:20 22:18 2G-20
1G-21 16:20 22:18
WER LIMITED Date: 20.12.10
W HSD RPP)
n Road, Thakurgaon
ngine Status Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
Excitor Rotor cable has been damaged
16:20 22:18 B-Shift
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift
16:20 22:18
Lube oil was mixed with Coolant water Engines View
16:20 22:18
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water
16:20 22:18
Lube oil was mixed with Coolant water
16:20 22:18
Security NUT-BOLTs removed from exhaust manifold Gensets Load Status
Buiding
Lube oil was mixed with Coolant water nos.
16:20 22:18 B-01
16:20 22:18 B-02
16:20 22:18 Total
Excessisive vibration
Shift In-Charge

Md.Hassanuzzaman

Md.Moniruzzaman

Md. Anisur Rahman

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Running Set Load % load of generation
Gensets (KW) engines (MW)
14 1000 89.93 14
8 1400 90.44 11.2
25.2
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N G/N
1G-1 11:02 13:05 15:35 22:32 2G-1 Ex
1G-2 11:02 13:05 15:35 22:32 2G-2 11:02
1G-3 11:02 13:05 15:35 22:32 2G-3 Lu
1G-4 11:02 13:05 15:35 22:32 2G-4
1G-5 Fire introduced in ALT 2G-5 11:02
1G-6 11:02 13:05 15:35 22:32 2G-6 Lu
1G-7 Fire introduced in ALT 2G-7 11:02
1G-8 11:02 13:05 15:35 22:32 2G-8
1G-9 Fire introduced in ALT 2G-9 Lube
1G-10 11:02 13:05 15:35 22:32 2G-10 Lu
1G-11 Water leakage from oil cooler 2G-11 Lu
1G-12 11:02 13:05 15:35 22:32 2G-12 11:02
1G-13 Fire introduced in ALT 2G-13 Lu
1G-14 11:02 13:05 15:35 22:32 2G-14 11:02
1G-15 11:02 13:05 15:35 22:32 2G-15 Security N

1G-16 Fire introduced in ALT 2G-16 Lu


1G-17 Fire introduced in ALT 2G-17 11:02
1G-18 11:02 13:05 15:35 22:32 2G-18 11:02
1G-19 11:02 13:05 15:35 22:32 2G-19 11:02
1G-20 11:02 13:05 15:35 22:32 2G-20
1G-21 11:02 13:05 15:35 22:32
LIMITED Date: 21.12.10
D RPP)
Thakurgaon
atus Shift In-Charge

A-Shift Md.Hassanuzzaman
Excitor Rotor cable has been damaged
13:05 15:35 22:32 B-Shift Md.Moniruzzaman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift Md. Anisur Rahman
13:05 15:35 22:32
Lube oil was mixed with Coolant water Engines View
13:05 15:35 22:32 Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water Engine under maintenance
13:05 15:35 22:32
Lube oil was mixed with Coolant water Engine out of order
13:05 15:35 22:32
Security NUT-BOLTs removed from exhaust manifold Gensets Load Status
Buiding Running Set Load
Lube oil was mixed with Coolant water nos. Gensets (KW)
13:05 15:40 22:32 B-01 14 1000
13:05 15:35 22:32 B-02 8 1400
13:05 15:35 22:32 Total
Excessisive vibration
In-Charge

ssanuzzaman

niruzzaman

sur Rahman

View

e under maintenance

e out of order

Load Status Total


% load of generation
engines (MW)
89.93 14
90.44 11.2
25.2
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 14:58 22:25 2G-1
1G-2 14:58 22:25 2G-2
1G-3 14:58 22:25 2G-3
1G-4 14:58 22:25 2G-4
1G-5 Fire introduced in ALT 2G-5
1G-6 14:58 22:25 2G-6
1G-7 Fire introduced in ALT 2G-7
1G-8 14:58 22:25 2G-8
1G-9 Fire introduced in ALT 2G-9
1G-10 14:58 22:25 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 14:58 22:25 2G-12
1G-13 Fire introduced in ALT 2G-13
1G-14 14:58 22:25 2G-14
1G-15 14:58 16:45 17:15 17:30 17:50 18:18 Grease leakage from NDE bearing 2G-15
1G-16 Fire introduced in ALT 2G-16
1G-17 Fire introduced in ALT 2G-17
1G-18 14:58 22:25 2G-18
1G-19 14:58 22:25 2G-19
1G-20 14:58 22:25 2G-20
1G-21 14:58 22:25

Outage Engine No.

B-01 8
B-02 12
Total 20
ER LIMITED Date: 22.12.10
HSD RPP)
oad, Thakurgaon
ne Status Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md.Moniruzzaman
Excitor Rotor cable has been damaged
14:58 22:25 B-Shift Md. Anisur Rahman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line C-Shift Shahriar Kabir
14:58 22:25
Lube oil was mixed with Coolant water Engines View
14:58 22:25 Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water
Lube oil was mixed with Coolant water Engine under maintena
14:58 22:25
Lube oil was mixed with Coolant water Engine out of order
14:58 22:25
Security NUT-BOLTs removed from exhaust manifold Gensets Load Status
Lube oil was mixed with Coolant water Buiding Running
14:58 22:25 nos. Gensets

14:58 22:25 B-01 13


14:58 22:25 B-02 8
Excessisive vibration Total 21
Shift In-Charge

Md.Moniruzzaman

Md. Anisur Rahman

Shahriar Kabir

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 13
1400 90.44 11.2
24.2
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 8:40 10:10 15:58 22:42 2G-1
1G-2 8:40 10:10 15:58 22:42 2G-2
1G-3 8:40 10:10 15:58 22:42 2G-3
1G-4 8:40 10:10 15:58 22:42 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 8:40 10:10 15:58 22:42 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 8:40 10:10 15:58 22:42 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 8:40 10:10 15:58 22:42 2G-10
1G-11 Water leakage from oil cooler ( on 2.11.10 ) 2G-11
1G-12 8:40 10:10 15:58 22:42 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 8:40 10:10 15:58 22:42 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 8:40 10:10 15:58 22:42 2G-18
1G-19 8:40 10:10 15:58 22:42 2G-19
1G-20 8:40 10:10 15:58 22:42 2G-20
1G-21 8:40 10:10 15:58 22:42

Outage Engine No.

B-01 8
B-02 12
Total 20
ER LIMITED Date: 23.12.10
HSD RPP)
oad, Thakurgaon
ne Status Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md.Moniruzzaman
Excitor Rotor cable has been damaged
8:40 10:10 15:58 17:40 18:15 22:42 B-Shift Md. Anisur Rahman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Shahriar Kabir
8:40 10:10 15:58 22:42
Lube oil was mixed with Coolant water ( on 11.12.10 ) Engines View
8:40 10:10 15:58 22:42 Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water ( on 16.11.10 )
Lube oil was mixed with Coolant water ( on 7.11.10 ) Engine under maintenance
8:40 10:10 17:15 22:42
Lube oil was mixed with Coolant water Engine out of order
8:40 10:10 15:58 22:42
Security NUT-BOLTs removed from exhaust manifold Gensets Load Status
Lube oil was mixed with Coolant water ( on 1.12.10 ) Buiding Running
8:40 10:10 15:58 22:42 nos. Gensets

8:40 10:10 15:58 17:15 17:40 22:42 B-01 13


8:40 10:10 15:58 22:42 B-02 8
Excessisive vibration Total 21
Shift In-Charge

Md.Moniruzzaman

Md. Anisur Rahman

Shahriar Kabir

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 13
1400 90.44 11.2
24.2
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status

G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 16:45 22:12 2G-1
1G-2 16:45 22:12 2G-2
1G-3 16:45 22:12 2G-3
1G-4 16:45 22:12 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 16:45 22:12 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 16:45 22:12 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 16:45 22:12 2G-10
1G-11 Water leakage from oil cooler ( on 2.11.10 ) 2G-11
1G-12 16:45 22:12 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 16:45 22:12 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 16:45 22:12 2G-18
1G-19 16:45 22:12 2G-19
1G-20 16:45 22:12 2G-20
1G-21 16:45 22:12

Outage Engine Nos.

B-01 8
B-02 10
Total 18
ER LIMITED Date: 24.12.10
HSD RPP)
oad, Thakurgaon
ne Status Shift In-Charge

A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
17:45 21:10
16:45 22:12 B-Shift Md. Anisur Rahman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Shahriar Kabir
16:45 22:12
Lube oil was mixed with Coolant water ( on 11.12.10 ) Engines View
16:45 22:12 Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water ( on 16.11.10 )
Lube oil was mixed with Coolant water ( on 7.11.10 ) Engine under maintenance
16:45 22:12
Lube oil was mixed with Coolant water Engine out of order
16:45 22:12
16:45 22:12 Gensets Load Status
Lube oil was mixed with Coolant water ( on 1.12.10 ) Buiding Running
16:45 22:12 nos. Gensets

16:45 22:12 B-01 12


16:45 22:12 B-02 10
Excessisive vibration Total 22
Shift In-Charge

Md. Anisur Rahman

Shahriar Kabir

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 12
1400 90.44 14
26
RZ POWER LIMITED Date: 25.12.10
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status Shift In-Charge
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md. Anisur Rahman
1G-1 11:43 22:33 2G-1 11:43 22:33
1G-2 11:43 22:33 2G-2 11:43 22:33 B-Shift Shahriar Kabir
1G-3 11:43 22:33 2G-3 Lube oil was mixed with Coolant water
1G-4 11:43 22:33 2G-4 Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Hasanuzzaman
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5 11:43 22:33
1G-6 11:43 22:33 2G-6 Lube oil was mixed with Coolant water ( on 11.12.10 ) Engines View
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7 Radiator Water leakage (On 25.12.10) Engine Running
1G-8 11:43 22:33 2G-8 Water leakage from oil cooler
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9 Lube Oil leakage from Turbo oil return line Engine S/D
1G-10 11:43 22:33 2G-10 Lube oil was mixed with Coolant water ( on 16.11.10 )
1G-11 Water leakage from oil cooler 2G-11 Lube oil was mixed with Coolant water ( on 7.11.10 ) Engine under maintenance
1G-12 12:05 22:33 2G-12 11:43 22:33
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13 Lube oil was mixed with Coolant water Engine out of order
1G-14 11:43 15:10 15:30 22:33 2G-14 11:43 22:33
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15 11:43 13:50 16:15 22:33 Gensets Load Status
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16 Lube oil was mixed with Coolant water ( on 1.12.10 ) Buiding Running Set Load % load of
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17 11:43 12:15 13:10 22:33 nos. Gensets (KW) engines
1G-18 11:43 22:33 2G-18 11:43 22:33 B-01 13 1000 89.93
1G-19 11:43 22:33 2G-19 12:00 22:33 B-02 9 1400 90.44
1G-20 11:43 22:33 2G-20 Excessisive vibration Total 22
1G-21 11:43 22:33

Engines Load Reduction Status Engine Status


G/N Reduced Load (KW) Cause of load reduction G/N Reduced Load (KW) Cause of load reduction Genset Outage Running S/D
1G-3 950 Exhaust manifold turn reddish 2G-2 1350 ACB trippes for high phase current Building Engine Engine Engine
1G-4 950 Exhaust manifold turn reddish 2G-17 1160 Wrn speed reg. lim alarm B-01 8 13 0
1G-6 950 Exhaust manifold turn reddish 2G-19 1200 Exhaust manifold turn reddish B-02 10 9 0
1G-8 950 Exhaust manifold turn reddish Total 18 22 0
1G-10 950 Exhaust manifold turn reddish
1G-12 900 Exhaust manifold turn reddish
Total
generation
(MW)

13
12.6
25.6

Under
Maint.
0
1
1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 14:50 22:10 2G-1
1G-2 14:50 22:10 2G-2
1G-3 14:50 22:10 2G-3
1G-4 14:50 22:10 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 14:50 22:10 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 14:50 22:10 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 14:50 22:10 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 14:50 22:10 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 14:50 22:10 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 14:50 22:10 2G-18
1G-19 14:50 22:10 2G-19
1G-20 14:50 22:10 2G-20
1G-21 14:50 22:10

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
1G-14 900 Tripped by BOC IDMT
ER LIMITED Date: 25.12.10
W HSD RPP)
Road, Thakurgaon
gine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
14:50 22:10
14:50 22:10 B-Shift Shahriar Kabir
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Md.Hasanuzzaman
14:50 22:10
Lube oil was mixed with Coolant water ( on 11.12.10 ) Engines View
Radiator Water leakage (On 25.12.10) Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water ( on 16.11.10 )
Lube oil was mixed with Coolant water ( on 7.11.10 ) Engine under maintenanc
14:50 22:10
Lube oil was mixed with Coolant water Engine out of order
14:50 22:10
14:50 22:10 Gensets Load Status
Lube oil was mixed with Coolant water ( on 1.12.10 ) Buiding Running
14:50 22:10 nos. Gensets
14:50 22:10 B-01 13
14:50 22:10 B-02 9
Excessisive vibration Total 22

d Reduction Status Engine Status


Reduced Load (KW) Cause of load reduction Genset Outage
Building Engine
B-01 8
B-02 10
Total 18
Shift In-Charge

Shahriar Kabir

Md.Hasanuzzaman

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 13
1400 90.44 12.6
25.6

Engine Status
Running S/D Under
Engine Engine Maint.
13 0 0
9 0 1
22 0 1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 17:01 23:04 2G-1
1G-2 17:01 23:04 2G-2
1G-3 17:01 23:04 2G-3
1G-4 17:01 23:04 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 17:01 23:04 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 17:01 23:04 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 17:01 23:04 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 17:01 23:04 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 17:01 23:04 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 17:01 23:04 2G-18
1G-19 17:01 23:04 2G-19
1G-20 17:01 23:04 2G-20
1G-21 17:01 23:04

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
2G-1
2G-17
ER LIMITED Date: 25.12.10
W HSD RPP)
Road, Thakurgaon
gine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift
17:01 23:04
17:01 23:04 B-Shift Shahriar Kabir
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Md.Hasanuzzaman
17:01 23:04
Lube oil was mixed with Coolant water ( on 11.12.10 ) Engines View
Radiator Water leakage (On 25.12.10) Engine Running
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line Engine S/D
Lube oil was mixed with Coolant water ( on 16.11.10 )
Lube oil was mixed with Coolant water ( on 7.11.10 ) Engine under maintenanc
17:01 23:04
Lube oil was mixed with Coolant water Engine out of order
17:01 23:04
17:01 23:04 Gensets Load Status
Lube oil was mixed with Coolant water ( on 1.12.10 ) Buiding Running
17:01 23:04 nos. Gensets
17:01 23:04 B-01 13
17:01 23:04 B-02 9
Excessisive vibration Total 22

d Reduction Status Engine Status


Reduced Load (KW) Cause of load reduction Genset Outage
1250 Load fluctuation Building Engine
1200 Load fluctuation B-01 8
B-02 10
Total 18
Shift In-Charge

Shahriar Kabir

Md.Hasanuzzaman

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 13
1400 90.44 12.6
25.6

Engine Status
Running S/D Under
Engine Engine Maint.
13 0 0
9 0 1
22 0 1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 9:45 13:00 15:52 22:35 2G-1
1G-2 9:45 13:00 15:52 22:35 2G-2
1G-3 9:45 13:00 15:52 22:35 2G-3
1G-4 9:45 13:00 15:52 22:35 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 9:45 13:00 15:52 22:35 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 9:45 13:00 15:52 22:35 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 9:45 13:00 15:52 22:35 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 9:45 13:00 15:52 22:35 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 9:45 13:45 15:52 22:35 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 9:45 13:45 15:52 22:35 2G-18
1G-19 9:45 13:45 15:52 22:35 2G-19
1G-20 9:45 13:45 15:52 22:35 2G-20
1G-21 9:45 13:45 15:52 22:35

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
2G2 1200 Showing alarm "wrn speed reg. lim"
2G17 900 Showing alarm "wrn speed reg. lim"

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 28.12.10
W HSD RPP)
Road, Thakurgaon
gine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md. Rubayet Imteaz
9:45 13:00 15:52 22:35
9:45 13:00 15:52 22:35 B-Shift Md.Hasanuzzaman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift
9:45 13:00 15:52 22:35
Lube oil was mixed with Coolant water ( on 11.12.10 ) Gensets Load Status at 13:00 p
Radiator Water leakage (On 25.12.10) Buiding Running
Water leakage from oil cooler nos. Gensets
Lube Oil leakage from Turbo oil return line B-01 5
Lube oil was mixed with Coolant water ( on 16.11.10 ) B-02 4
Lube oil was mixed with Coolant water ( on 7.11.10 ) Total 9
9:45 13:00 15:52 22:35
Lube oil was mixed with Coolant water Gensets Load Status
9:45 13:45 15:52 22:35 Buiding Running
9:45 13:45 15:52 22:35 nos. Gensets
Lube oil was mixed with Coolant water ( on 1.12.10 ) B-01 13
9:45 13:00 15:52 22:35 B-02 9
9:45 13:45 15:52 22:35 Total 22
9:45 13:45 15:52 22:35
Excessisive vibration

ad Reduction Status Engine Status


Reduced Load (KW) Cause of load reduction Genset Outage
Building Engine
B-01 8
B-02 10
Total 18
Shift In-Charge
Md. Rubayet Imteaz

Md.Hasanuzzaman

ets Load Status at 13:00 pm Total


Set Load % load of generation
(KW) engines (MW)
1000 89.93 5
1400 90.44 5.6
10.6

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 13
1400 90.44 12.6
25.6

Engine Status
Running S/D Under
Engine Engine Maint.
13 0 0
9 0 1
22 0 1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 9:20 12:55 16:30 22:52 2G-1
1G-2 9:20 12:55 16:30 22:52 2G-2
1G-3 9:20 12:55 16:30 22:52 2G-3
1G-4 9:20 12:55 16:30 22:52 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 9:20 12:30 Fire introduced in ALT ( on 29.12.10 ) 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 9:20 12:55 16:30 22:52 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 9:20 12:55 16:30 22:52 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 8:35 12:55 16:30 22:52 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 8:35 12:55 16:30 22:52 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 8:35 12:55 16:30 22:52 2G-18
1G-19 8:35 12:55 16:30 22:52 2G-19
1G-20 9:20 12:55 16:30 22:52 2G-20
1G-21 8:35 12:55 16:30 22:52

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
2G2 1130 Showing alarm "wrn speed reg. lim"

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 29.12.10
W HSD RPP)
Road, Thakurgaon
gine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md. Rubayet Imteaz
9:20 12:55 16:30 22:52
9:20 12:55 16:30 22:52 B-Shift Md.Hasanuzzaman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift
9:20 12:55 16:30 22:52
Lube oil was mixed with Coolant water ( on 11.12.10 ) Gensets Load Status at 08:4
Radiator Water leakage (On 25.12.10) Buiding Running
Water leakage from oil cooler nos. Gensets
Lube Oil leakage from Turbo oil return line B-01 5
Lube oil was mixed with Coolant water ( on 16.11.10 ) B-02 4
Lube oil was mixed with Coolant water ( on 7.11.10 ) Total 9
8:35 12:55 16:30 22:52
Lube oil was mixed with Coolant water Gensets Load Status
8:35 12:55 16:30 22:52 Buiding Running
9:20 12:55 16:30 22:52 nos. Gensets
Lube oil was mixed with Coolant water ( on 1.12.10 ) B-01 12
9:20 12:55 16:30 22:52 B-02 9
8:35 12:55 16:30 22:52 Total 21
8:35 12:55 16:30 22:52
Excessisive vibration

ad Reduction Status Engine Status


Reduced Load (KW) Cause of load reduction Genset Outage
Building Engine
B-01 9
B-02 11
Total 20
Shift In-Charge
Md. Rubayet Imteaz

Md.Hasanuzzaman

ets Load Status at 08:45 am Total


Set Load % load of generation
(KW) engines (MW)
1000 89.93 5
1400 90.44 5.6
10.6

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 12
1400 90.44 12.6
24.6

Engine Status
Running S/D Under
Engine Engine Maint.
12 0 0
9 0 1
21 0 1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 10:05 13:26 16:35 23:15 2G-1
1G-2 10:05 13:26 16:35 23:15 2G-2
1G-3 10:05 13:26 16:35 23:15 2G-3
1G-4 10:05 13:26 16:35 23:15 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 Fire introduced in ALT ( on 29.12.10 ) 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 10:05 13:26 16:35 23:15 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 10:05 13:26 16:35 23:15 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 10:05 13:26 16:35 23:15 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 10:05 13:26 16:35 23:15 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 10:05 13:26 16:35 23:15 2G-18
1G-19 10:05 13:26 16:35 23:15 2G-19
1G-20 10:05 13:26 16:35 23:15 2G-20
1G-21 10:05 13:26 16:35 23:15

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
2G2 1130 Showing alarm "wrn speed reg. lim"
2G13 1300 Exhaust manifold turned to red

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 30.12.10
W HSD RPP)
Road, Thakurgaon
ine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md. Rubayet Imteaz
10:05 13:26 16:35 23:15
10:05 13:26 16:35 23:15 B-Shift Md. Anisur Rahman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Shahriar Kabir
10:05 13:26 16:35 23:15
Lube oil was mixed with Coolant water ( on 11.12.10 )
Radiator Water leakage (On 25.12.10)
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
Lube oil was mixed with Coolant water ( on 16.11.10 )
16:35 18:30 Lube Oil mixed with water
10:05 13:26 16:35 23:15
Lube oil was mixed with Coolant water Gensets Load Status
10:05 13:26 16:35 23:15 Buiding Running
10:05 13:26 16:35 23:15 nos. Gensets
Lube oil was mixed with Coolant water ( on 1.12.10 ) B-01 12
10:05 13:26 16:35 23:15 B-02 9
10:05 13:26 16:35 23:15 Total 21
10:05 13:26 16:35 23:15
Excessisive vibration

d Reduction Status Engine Statu


Reduced Load (KW) Cause of load reduction Genset Outage
Building Engine
B-01 9
B-02 11
Total 20
Shift In-Charge
Md. Rubayet Imteaz

Md. Anisur Rahman

Shahriar Kabir

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 12
1400 90.44 12.6
24.6

Engine Status
Running S/D Under
Engine Engine Maint.
12 0 0
9 0 1
21 0 1
RZ POWER LIMITED
(50 MW HSD RPP)
Thakurgaon Road, Thakurgaon
Engine Status
G/N A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) G/N
1G-1 17:10 2G-1
1G-2 17:10 2G-2
1G-3 17:10 2G-3
1G-4 17:10 2G-4
1G-5 Fire introduced in ALT ( on 29.9.10 ) 2G-5
1G-6 Fire introduced in ALT ( on 29.12.10 ) 2G-6
1G-7 Fire introduced in ALT ( on 5.12.10 ) 2G-7
1G-8 17:10 2G-8
1G-9 Fire introduced in ALT (on 11.10.10 ) 2G-9
1G-10 17:10 2G-10
1G-11 Water leakage from oil cooler 2G-11
1G-12 17:10 2G-12
1G-13 Fire introduced in ALT ( on 6.12.10 ) 2G-13
1G-14 17:10 2G-14
1G-15 Grease leakage from NDE bearing ( on 22.12.10 ) 2G-15
1G-16 Fire introduced in ALT ( on 4.11.10 ) 2G-16
1G-17 Fire introduced in ALT ( on 11.12.10 ) 2G-17
1G-18 17:10 2G-18
1G-19 17:10 2G-19
1G-20 17:10 2G-20
1G-21 17:10

Engines Load Reduction Status


G/N Reduced Load (KW) Cause of load reduction G/N
2G2 Showing alarm "wrn speed reg. lim"
2G13 Exhaust manifold turned to red

Engines View
Engine Running

Engine S/D

Engine under maintenance

Engine out of order


ER LIMITED Date: 31.12.10
W HSD RPP)
Road, Thakurgaon
ine Status Shift In-Charge
A Shift ( 7:00 - 14:00 ) B Shift ( 14:00 - 22:00 ) C Shift ( 22:00 - 7:00 ) A-Shift Md. Anisur Rahman
17:10
Lube oil was mixed with Coolant water B-Shift Md.Moniruzzaman
Lube oil was mixed with Coolant water
Fire introduce in turbo lube oil line ( on 11.11.10 ) C-Shift Shahriar Kabir
17:10
Lube oil was mixed with Coolant water ( on 11.12.10 )
Radiator Water leakage (On 25.12.10)
Water leakage from oil cooler
Lube Oil leakage from Turbo oil return line
17:10
Lube oil was mixed with Coolant water
17:10
Lube oil was mixed with Coolant water Gensets Load Status
17:10 Buiding Running
17:10 nos. Gensets
Lube oil was mixed with Coolant water ( on 1.12.10 ) B-01 12
17:10 B-02 8
17:10 Total 20
17:10 PF rapidly vary
Excessisive vibration

d Reduction Status Engine Status


Reduced Load (KW) Cause of load reduction Genset Outage
Building Engine
B-01 9
B-02 12
Total 21
Shift In-Charge
Md. Anisur Rahman

Md.Moniruzzaman

Shahriar Kabir

Gensets Load Status Total


Set Load % load of generation
(KW) engines (MW)

1000 89.93 12
1400 90.44 11.2
23.2

Engine Status
Running S/D Under
Engine Engine Maint.
12 0 0
8 0 1
20 0 1

You might also like