Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

S U B S TAT I O N A U T O M AT I O N

C264-R Application
Modular Remote
Terminal Unit

SOPHISTICATED REMOTE TERMINAL UNIT FOR


SUBSTATION CONTROL, MONITORING, DISTRIBUTED IEDS
DATA CONCENTRATION AND GATEWAY COMMUNICATION
WITH SCADAS.

The MiCOM C264-R combines the usual RTUs features with


the benefits of fast Ethernet communication. Its intrinsic
high-performance is further expanded through the modular
I/Os acquisition racks. This up to date design helps the
user to simplify the engineering and installation, improve
reliability and quality as well as increase efficiency through
space and cost reductions in wiring, testing, maintenance
and management.

The MiCOM C264-R offers natively an on-board 100Mb


Ethernet communication for SCADA communication, simple
maintenance access and the connection of many I/Os
acquisition racks. This is in addition of the serial ports for
every application using multiple standard protocols. Each
port is able to communicate with a protocol including
IEC60870-5-103, IEC 60870-5-101, MODBUS, DNP3.0, or
with a SOE serial printer.

The MiCOM C264-R with high-performance, large capacity,


expandable is well adapted for turnkey applications as well
as retrofit installations. MiCOM C264-R is also to be
considered as a step on the way of Digital Control Systems.
Customer Benefits
• Modular RTU for FIELD OF APPLICATION
electrical substations
requiring large capacities The MiCOM C264-R modular Remote Terminal Unit (RTU) provides a powerful solution for SCADA
• IEDs and Sub-RTUs communication, Sequence of Event Recorder (SER), and can be integrated to digital substation
concentrator control systems. It is designed for a wide range of applications:
• SCADA interfaces with Electrical utility
serial and Ethernet
> Transmission and distribution substations
protocols
> Power Plant substations
• A step for a smooth
transition to Digital Control
Industry
Systems
• LCD graphical display for > Process control, including manufacturing, transit, telecommunications, testing, etc...
user-friendly local control, > Oil and gas, including pipelines
monitoring, and maintenance > Water and wastewater
• Expandable design with single
or multiple racks architectures Tr a n s p o r t a t i o n e l e c t r i c a l s u p e r v i s i o n a n d c o n t ro l
• High availability and reliability > Railways
with redundant communication
facilities > Airport

AREVA T&D
APPLICATION PROFILE TECHNICAL DATA

> Stand-alone RTU (Single or Multiple I/Os racks) HARDWARE


> Sequence of Event Recorder (SER) – SOE printing
> IEDs and remote sub-RTU’s data concentrator > Case

> Substation Gateway and protocol converter • MiCOM C264C


> Integrated into the AREVA-T&D DCS and SCADA WxHxD 40T(206 mm) x 4U(177 mm) x 168 mm
solutions Slots 6 free assignment
• MiCOM C264
WxHxD 80T(405 mm) x 4U(177 mm) x 168 mm
Slots 15 free assignment
GENERAL FUNCTIONS

> Data acquisition and processes for digital, analogue > C o n t ro l p a n e l


values inputs and outputs
• Large graphical LCD (optional)
> Control and monitoring of switching devices
• Display 72 x 72 mm (optional)
> Configurable indications on local LCD screen, • Buttons (12): 7 for operations -
graphical Mimics and LEDs 5 for control (optional)
> Standardised and proprietary communication • LEDs 17, 12 free configurable
protocols
> Sequence of Events (SOE) print in chronological > Po w e r s u p p ly b o a rd
order
• UN 24VDC, 48//60VDC, 110/125VDC,
> Local storage of events, counters and measurement 220 VDC,
values 230 VAC 50/60 Hz
> Download of the configuration thru Ethernet
• Watchdog, Digital Input and Output relays for
or from SCADA (IEC101 serial communication) redundancy management
> Automation sequences (option)
> Maintenance facilities over Ethernet (I/O values
> P ro c e s s o r b o a rd
visualisation, hardware status, software and
database download), with convivial software tool,
• 32-bit Power PC-based processor
on standard PC.
• Internal Watchdog
• Clock 80 Mhz
• RAM 64 Mbytes
MiCOM C264-R architecture
• Flash 16 Mbytes
• Ethernet-Based 10/100Base-FX or
10/100Base-TX
• up to 4 serial interfaces RS232/485/optical fibre
SCADAs on each rack
• IRIG-B interface, BNC plug, Amplitude modulated.
Standard: NF- 5 85-500, May 1987.

Serial Links to
Ethernet link to Configuration and > D i g i t a l I n p u t B o a r d (16 DI)
SCADA (IEC101, SCADA (IEC104) Maintenance Tools
Modbus, DNP3, HNZ)
• 16 optically insulated inputs with one common
for 2 DI.
Main UN 24, 48/60, 110/125, 220 VDC
with DIU200 board
Printer
or
UN 24 - 220 VDC
with multi-voltage DIU210 board
Ethernet
Extension racks

Legacy serial buses


(IEC103, IEC101,
Modbus, DNP3)
Inputs / Outputs
IEDs, relays, Sub-RTUs

2>3
> D i g i t a l O u t p u t B o a r d (10 DO) COMMUNICATIONS
• 8 outputs NO + 2 outputs NO/NC • Standard Ethernet SCADA p ro t o c o l s
UN 24- 250 VDC / 230 VAC IEC 60870-5-104 (multi-client), DNP3/IP (option)
• Continuous current: 2,5A Ethernet 10/100Base-FX or 10/100Base-TX
short duration current: • Standard serial SCADA p ro t o c o l s
30A for 500ms, 100A for 30ms. IEC 60870-5-101, MODBUS, HNZ, DNP3 (option)
Breaking capacity: • Interfaces
DC: 50W resistive Optical / RS232 / RS422 / RS485
15 W inductive
(L/R = 20ms)
• S t a n d a rd I E D s p ro t o c o l s
IEC 60870-5-103, MODBUS,
IEC 60870-5-101, DNP3 (option)
> M i x e d b o a r d (8 DI / 4DO) • S y n c h ro n i s a t i o n
C i r c u i t b r e a k e r c o n t r o l b o a r d (CCU200) External synchronisation using IRIG-B

• 8 optically insulated inputs with one common


for 2 DI. RTU CAPACITY
UN 24, 48/60, 110/125, and 220 VDC
• 4 power outputs relay (2 NO contacts) > Multiple acquisition racks over Ethernet
UN 24- 250 VDC / 230 VAC > Up to 240 Digital Input signals per rack (15 slots)
Continuous current: 5A > Up to 4 serial links on a rack (RS232/RS485/optical)
short duration current: 250A for 30ms
> Up to 2 SCADAs simultaneous connections
Breaking capacity:
> Double lines management over IEC60870-5-101
(double pole contacts wired in serial)
SCADA connections
DC: 100W resistive
30W inductive > Up to 16 IEDs on the RS485 legacy buses
> Global data management of up to 5012 digital
> A n a l o g u e I n p u t B o a rd (4AI /8AI) datapoints, 1024 Analog values, 1024 Digital
outputs, 100 Setpoints, 100 Tap Position Indication
• 4 isolated analogue inputs for measuring on the C264-R
transducer connection (AIU201). > Redundancy of SCADA interface (option)
Current: ± 1 / 2 / 5 / 10 / 20 mA / 4-20 mA
Voltage: ± 1.25 / 2.5 / 5 / 10 V
• 8 analogue inputs for measuring SOE RECORDS
transducer connection (AIU21x).
Current: ± 1 / 2 / 5 / 10 / 20 mA / 4-20 mA > 1ms time tagging
• Chronological order
> A n a l o g u e O u t p u t B o a rd (4AO) • 1 standard serial printer
> 2000 events recorded in non volatile memory
• 4 analogue outputs with 4 read inhibit output (Flash disk)
relays (AOU200). > The 200 most recent events readable on optional
Current: ± 5 / 10 / 20 mA / 4-20 mA LCD screen
External power supply (48V ±5%)
Output maintained in case of C264 power supply
failure STANDARD COMPLIANCE

Superior construction: environment, EMC, isolations in


accordance with IEC Standards.

MiCOM C264:
a compact, powerfull and innovative RTU
for electrical applications
MiCOM is a registered trademark of AREVA. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. - 389191982 RCS PARIS - Printed in France
AUTOMATION-L3-C264RTU-BR-05.07-1287b-GB - © - AREVA - 2007. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA.

AREVA T&D Worldwide Contact Centre: Our policy is one of continuous development. Accordingly the
design of our products may change at any time. Whilst every
http://www.areva-td.com/contactcentre/ effort is made to produce up to date literature, this brochure
Tel.: +44 (0) 1785 250 070 should only be regarded as a guide and is intended for
information purposes only. Its contents do not constitute an offer
for sale or advise on the application of any product referred to in
it. We cannot be held responsible for any reliance on any
www.areva-td.com decisions taken on its contents without specific advice.
www.areva-td.com/substationautomation