NTPC NATIONAL THERMAL POWER CORPORATION LTD.

(ENGINEERING DIVISION)
ENGINEERING OFFICE COMPLEX
A-8A, SEC-24, NOIDA, U.P.201301
PH.:0120-2410333, FAX:0120-2410136
TRANSMITTAL FOR DOCUMENTS/DRAWINGS

FROM : CTF(Sipat TF) TO: Sh. R.R.Sharma (Sr.Mgr.(ENC))


BHEL(HWR),HEEP,RANIPUR,HARIDWA
REF. : CC:PES:9545:110:01:5537 R-249403
CC:Mr K S Mathur;AGM(PMG)
DATE : 08/09/05 M/s BHEL.HT House;KG Marg;New Delhi-
110001

SUB :SIPAT - II-STG


Please find enclosed following drawings/documents for necessary action at your end as indicated
in purpose code.
SL NTPC Drg No Title Re Categor Appl
No Vendor Drg No v y Date
1 9545-110-03-HW-PVI- DATA SHEET FOR 01 III 08/09/05
Y-004 CAPACITANCE TYPE LEVEL
DS/M444-I TRANSMITTER
2 9545-110-03-HW-PVI- DATA SHEET FOR 01 III 08/09/05
Y-005 CAPACITANCE TYPE LEVEL
DS/M433-I SWITCH
3 9545-110-03-HW-PVI- DATA SHEET FOR LEVEL 01 II 08/09/05
Y-006 SWITCH
DS/L425-I

NOTE: All previous revisions shall be destroyed/marked”Superseded”


: Please acknowledge the receipt of drawings D.Kandaswamy
CTF(Sipat TF)
NTPC DRAWING NO:9545-110-03-HW-PVI-Y-006
Vendor Drawing No: DS/L425-I
Revision: 01
Drawing Title: DATA SHEET FOR LEVEL SWITCH
Category:II
Comments:
9-pin plug & socket shall be provided as G-4 pair cable is envisaged to be used from switch to local JB.
BHEL comments/clarification:
7 pin is sufficient to accommodate in the instrument as 8th wire need not to connect in the pin. 8th wire may please be
cut.

NTPC DRAWING NO:9545-110-03-HW-PVI-Y-005


Vendor Drawing No: DS/M433-I
Revision: 01
Drawing Title: DATA SHEET FOR CAPACITANCE TYPE LEVEL SWITCH
Category:III
Comments:
1.Considering the advese feedback received from NTPC sites regarding the performance of SBEM make level
switches, proven, reliable make of level switches, other than SBEM, shall be supplied. The same shall be subject to
NTPC QA approval.
BHEL comments/clarification:
The letter from NTPC is attached. Please note that the modified switches are being supplied for SIPAT.

NTPC DRAWING NO:9545-110-03-HW-PVI-Y-004


Vendor Drawing No: DS/M444-I
Revision: 01
Drawing Title: DATA SHEET FOR CAPACITANCE TYPE LEVEL TRANSMITTER
Category:III
Comments:
The make of capacitance type level transmitter shall be as per NTPC QA approval. Considering the fact that SBEM
make level switches have not performed satisfactorily in the MOT level application and the criticality of the
application, proven reliable make/ model other than SBEM shall be proposed.

BHEL comments/clarification:
The letter from NTPC is attached. Please note that the modified switches are being supplied for SIPAT.
~~/~C1~ ~
'CfTCR f' 00 , <IRftlI {

('lTffl Wf1m l1IT\mfI) ~


CORPORATE CENTRE
Nationa/Therma/Power Corporation Ltd. NOIDA
(A Government of India Enterprise)

m ~ I Ref. No.:
01/CQA/3140-001/1230-001

Mr. S.K. Ar~DGM(QAX),


Bharat Heavy Electricals Ltd.,
HEEP, Ranipur,
Hardwar-249403.

Sub: Capacitance Type level switch of Mis. SBEM, Pune make


for NTPC projects

Dear Sir,

This has reference to BHEL letter no. QAX:1140:1267 dated 27.8.2003


regarding subject proposal.

As per NTPC Simhadri site feedback MIs. SBEM have modified the
switches by providing additional contact retention circuit in their capacitance
type level swiches in unit # 2 and the performance of the switches has been
found to be satisfactory after above modification. The similar modification
shall be carried out for swiches used in unit # 1 also

In view of above we agree to your proposal of using MIs. SBEM,


Pune make capacitance type level switch for NTPC on going projects.
However MIs. BHEL shall ensure that capacitance type level switches with
above modification (provision of additional contfact retention circuit) are
supplied.

Thanking you,

f .~
9-/tx Jr4p ~/)C1~
Yours faithfully,

. ~v-'-W
-(-(B M Das)
(0 -:DGI1[ C 1<0:) : l., . CTF- Ramagundam
-sc M R.f!2~ (j I-r"L.{ -k-u /V..6"'"k...v

~
C'\ -..-t-.6.I'1
J/ (PPX, _ . P-V
.5/rv/.(. '. 0
f'\. ( . _ Sh.M""v"
JUZt~"f (c
v~ ~v'
1. f.:.L1"Cg\.o""-~
',p G A
t)l£.L' <L

J"-' ('ol-L:J~~ N"-rP t.


~11[ PPX-t) :
, P"r 1.. ~.A'NJ
_t7.K. ~Q)(.
.....
~ ~1Jftm. ~ -;io ~.a~. ~-24. ~ 1R<ffi-;io 13, ~ ("\JoJJo)fiR-201301

@ . UKAS
,
O'lA'm
".K:r
150-9002 Certified
~ ~ -
~
1f-f t\ 1ft ~ 'IfiA, ~
-;io : 2410333 (10 ~), 2410116 (5~)
<l>1"'~<N1,7, 1i-C~G.'i~I"'(,\~,
$m : 2410136,2410137
cffiQ\m, ~ ~-110003
ENGINEERINGOFFICECOMPLEX,Plot No. A-a A, Sector-24, Post Box No. 13, Noida (U.P.)Pin-201 301
Telephone No. : 2410333 (10 Lines) 2410116 (5 Lines) Fax: 2410136,2410137
Regd. Office: NTPC Bhawan, SCOPE Complex, 7, Institutional Area, Lodhi Road, New Dclhi-110003
NTPC NATIONAL THERMAL POWER CORPORATION LTD.
(ENGINEERING DIVISION)
ENGINEERING OFFICE COMPLEX
A-8A, SEC-24, NOIDA, U.P.201301
PH.:0120-2410333, FAX:0120-2410136
TRANSMITTAL FOR DOCUMENTS/DRAWINGS

FROM : CTF(Sipat TF) TO: Sh. R.R.Sharma (Sr.Mgr.(ENC))


BHEL(HWR),HEEP,RANIPUR,HARIDWA
REF. : CC:PES:9545:110:01:4854 R-249403
CC:Mr K S Mathur;AGM(PMG)
DATE : 03/08/05 M/s BHEL.HT House;KG Marg;New Delhi-
110001

SUB :SIPAT - II-STG


Please find enclosed following drawings/documents for necessary action at your end as indicated
in purpose code.
SL NTPC Drg No Title Re Categor Appl
No Vendor Drg No v y Date
1 9545-110-03-HW-PVI- INSTRUMENT LIST for turbine 01 IV 02/08/05
R-005 C&I
4-180-00-06001_ST
2 9545-110-03-HW-PVI- DATA SHEET FOR LEVEL 00 II 02/08/05
Y-006 SWITCH
DS/L425-I
3 9545-110-03-HW-PVI- DATA SHEET FOR 00 II 02/08/05
Y-005 CAPACITANCE TYPE LEVEL
DS/M433-I SWITCH
4 9545-110-03-HW-PVI- DATA SHEET FOR 00 II 02/08/05
Y-004 CAPACITANCE TYPE LEVEL
DS/M444-I TRANSMITTER
5 9545-110-03-HW-PVI- DATA SHEET FOR PRESSURE 00 II 02/08/05
Y-003 TRANSMITTER
DS/T114-1

NOTE: All previous revisions shall be destroyed/marked”Superseded”


: Please acknowledge the receipt of drawings D.Kandaswamy
CTF(Sipat TF)
NTPC DRAWING NO:9545-110-03-HW-PVI-Y-003
Vendor Drawing No: DS/T114-1
Revision: 00
Drawing Title: DATA SHEET FOR PRESSURE TRANSMITTER
Category:II
Comments:
1.The make shall be clearly indicated.
2.Under sensor type, 'Capacitance/ inductive' has been indicated. BHEL to clearly indicate the sensor type
envisaged.
3.Technical literature shall be furnished.
4.It is not desirable that for the same package, two separate data sheets are being submitted from BHEL, Haridwar.
The make shall be uniform for the package, and a single data sheet should cover all the transmitters envisaged under
the package.
5.All applicable accessories like pulsation dampeners (for pump disharge etc. applications), valve manifolds etc.
shall also be covered in the data sheets.
BHEL reply/clarification:
1. Make has been indicated in the revised data sheets
2. Sensor type has been mentioned in the revised data sheet.
3. Technical literature is attached.
4. For Generator package , type of instrument is different than the steam apllication. ie most of the transmitter
is explosion type for generator. So, we have submitted the generator instrument separately . However, we
confirm that make of the instruments are from same supplier( M/s Yokogawa.
5. Pulsation dampeners are not applicable. Valve manifold is applicable for KKS LBS41/42CP002
6. revised data sheet is attached.

NTPC DRAWING NO:9545-110-03-HW-PVI-Y-004


Vendor Drawing No: DS/M444-I
Revision: 00
Drawing Title: DATA SHEET FOR CAPACITANCE TYPE LEVEL TRANSMITTER
Category:II
Comments:
1.BHEL to furnish justifications for selecting capacitance type level transmitters for this application, against
specified DP type transmitters for level applications, along with experience list.
2.Technical literature/ catalogues shall be furnished.
BHEL reply/clarification:
1. DP type transmitter is not applicable for level measurement of oil /CF system as all the transmitters are top
mounted. These capacitance type transmitters have been replaced by the level switch as per the our
collaborators practice. These have been supplied for Talcher, Simadri , Rihand & Ramagundam projects.
2. technical literature/catalogues are attached.
NTPC DRAWING NO:9545-110-03-HW-PVI-Y-005
Vendor Drawing No: DS/M433-I
Revision: 00
Drawing Title: DATA SHEET FOR CAPACITANCE TYPE LEVEL SWITCH
Category:II
Comments:
1.Make of the instrument to be indicated and the same shall be subject to NTPC QA approval.
2.Technical literature/ catalogues shall be furnished.
3.Installation drawing shall be furnished.

BHEL reply/clarification:
1. Make is added in the data sheet
2. Technical literature/catalogue is attached
3. These are top mounted with threaded connection.

NTPC DRAWING NO:9545-110-03-HW-PVI-Y-006


Vendor Drawing No: DS/L425-I
Revision: 00
Drawing Title: DATA SHEET FOR LEVEL SWITCH
Category:II
Comments:
1.Make to be indicated and the same shall be subject to NTPC QA approval.
2.Tecnical literature/ catalogues shall be furnishd.
3.The plug & socket connector shall be 9-pin so as to enable connection with G-4 PAIR cable as indicated in tender
drg. 0000-999-POI-A-065.
BHEL reply/clarification:
4. make is added in the data sheet
5. Technical literature/catalogue is attached
3. We will provide 7 pin plug & socket as per BHEL standard & as supplied for Talcher, Simadri , Rihand
& Ramagundam projects.

NTPC DRAWING NO:9545-110-03-HW-PVI-R-005


Vendor Drawing No: 4-180-00-06001_ST
Revision: 01
Drawing Title: INSTRUMENT LIST for turbine C&I
Category:IV
Comments:
BHEL to ensure that list is in line with the finalised P&IDs.

BHEL reply/clarification:
Confirmed.
PROJECT:- STEAM TURBINE C&I DOC. NO. DS/M433-I
SIPAT 2X500MW Stg II REV. NO. 01
PAGE 1 OF 1

DATA SHEET FOR CAPACITANCE TYPE LEVEL SWITCH


KEY NO. M433-I
APPLICATION OIL/ CF SYSTEM
sudhir gupta
cn=sudhir gupta, c=US,
S.NO. FEATURES. o=NTPC, ou=PROJ-ENGG
SIPAT TASK FORCE
APPROVED IN CAT-I after
1 Type Capacitance Type bhel reply/clarifications
2 Sensing Element Bar probe 2005.10.31 09:21:00 +05'30'

3 Material of Sensing Movement. SS 316.


4 End connection 1 1/2" BSP (M)
5 Over Range Test 150% of Max design pressure
6 Repeatablity +/- 0.5% of full range.
7 No of contacts. 2NO + 2NC
8 Rating of contacts 0.25A, 220V DC
9 Electrical connection Plug in socket
10 Set point/dead bandadjustment Provided , over full range
11 Housing Weather and dust proof as per IP-65
12 Identification Tag Plate.
13 Mounting Direct.
14 Range As per application
15 Power supply 24 V DC +/- 10 %
16 Working pressure 1 Kg/Cm2
17 Test pressurre 2 Kg/Cm2
18 Working Temp. 65 deg. C
19 AMPLIFIER Matching to appliction
20 Make/MODEL SBEM / 1-00-TXX40-9356360
Tests.
Calibration Accuracy/ Repeatability.
Dimenstion T.C.
Material T.C.

APPICABLE TAG NOS. OF INSTRUMENT LIST---41800006001

TAG NO.

MAV85CL005 0-750 mm
MAV85CL015 0-1400 mm
MAX89CL015 0-750 mm
MAX89CL041 0-150 mm
MAX89CL046 0-150 mm
MAX89CL051 0-150 mm
MAX91CL011 0-150 mm

C&I ENGG. PREPARED BY___________


BHEL, HARDWAR. CHECKED BY____________ DATE_13.08.05.___
CAPACITANCE TYPE SINGLE POINT LEVEL
SWITCH SERIES 114

Series 114 is a versatile Capacitance Type Single Point


Level Switch which can be used in a variety of
applications for detecting/controlling level of solids /
liquids when used with suitable probe unit.
Level switch consists of electronic control circuit housed
in cast aluminium weatherproof/sheet steel enclosure
whereas probe unit consists of electrode, transducer and
weatherproof / flameproof probe head to house
transducer.
For selection of suitable probe unit for your application
refer to leaflet LF-114-0803 (For liquids) & LF-114-0804
(For solids).

FEATURES

ˆ Weather proof enclosure


ˆ Surface/Pipe mounting versions
ˆ Time delay, dead band & probe failure alarm
available optionally.
ˆ Intrinsically safe option available.
SPECIFICATIONS ˆ Sensitivity :
ˆ Input : ± 0.5% of probe output
ˆ Ambient conditions :
Voltage signal from transducer in probe head
ˆ Relay contacts : Temperature - 0 to 550C
Relative humidity - 95% max (non condensing)
For weatherproof version
1 C/O, 6A @ 230 VAC/28 VDC (Resistive)
ˆ Calibration :
By physically changing level in tank
OR
2 C/O, 2A @ 230 VAC/28 VDC (Resistive)
ˆ Termination :
Suitable for 2.5mm2 conductor size
For sheetsteel version
1 C/O, 5A @ 230 VAC/24 VDC (Resistive)
ˆ Cable entry (weatherproof version only) :
ˆ Failsafe Features :
3 Nos., 3/4" UNF/ET (F) OR
3 Nos., 1/2" NPT (F)
Fail Safe High (FSH) or Fail Safe Low (FSL) - user
selectable
ˆ Cabling between Switch & Probe Head :
ˆ Time delay (optional) :
3x1.5mm2 Cu. cable - Upto 500 mtrs.
3x2.5mm2 Cu. cable - Upto 1000 mtrs.
12 sec -20 min. (user adjustable through (cable resistance < 10 Ohms per line)
ˆ
potentiometer at the front)
Controls :
ˆ Enclosures :
Weatherproof, cast aluminium polyurethane painted,
Potentiometer to set Level Alarm (std.) conforming to IP-65 as per IS-2147 suitable for
Potentiometer to set Time Delay (optional) surface/pipe mounting.
Potentiometer to set Dead Band (optional - for OR
sheetsteel version only)
ˆ Indications :
Sheetsteel polyurethane painted suitable for surface
mounting.
Red LED for Mains ON & Level Alarm (std.)
Red LED for Level Above Setpoint
ˆ Weight :
3.2 kg (Weatherproof version)
Red LED for Probe Failure Alarm (optional - for 2.2 kg (Sheetsteel version)
sheetsteel version only)
ORDERING CODE

1 1 4 C
SAFETY CABLE ENTRY
Non Intrinsically Safe (NON IS) - H 0 - No cable entry
Intriinsically safe - S F - 3/4" UNF / ET
T - 1/2" NPT
VERSION
Single point switch (1 C/O) - 1
POWER SUPPLY
Single point switch (2 C/O) - 2
1 - 115 VAC, 1 φ, 50 Hz
2 - 230 VAC, 1 φ, 50 Hz
MOUNTING/ENCLOSURE
Surface/Sheetsteel - 1 3 - 24 VDC
Surface/Cast aluminium weatherproof - 3
Pipe/Cast aluminium weatherproof - 5 FUNCTION
1 - Level alarm only
2 - Level and probe failure alarm
NOTE : 1) No probe failure alarm for weatherproof version. 3 - Level alarm with adjustable time delay
2) Version 2 is available only in weatherproof enclosure. 4 - Level alarm with adjustable time delay
and probe failure alarm
3) All above power supply options are inbuilt in sheetsteel version & are user selectable.
4) Dead band is available in sheetsteel version only.
5) No cable entry option is for surface mounted sheetsteel enclosure only.
DIMENSIONS
110 PIPE SIZE
140 1/2" TO 2 1/2"

270
40 113 225
150 72
235
140 235 185
185 160
160 140 130

180
φ7
φ7
180
Surface Mounting Weatherproof Pipe Mounted Weatherproof Surface Mounting Sheetsteel
DIMENSIONS
SINGLE POINT SWITCH (WEATHERPROOF SINGLE POINT SWITCH (SHEETSTEEL
ENCLOSURE) WITH TIME DELAY ENCLOSURE) WITH PROBE FAILURE ALARM
FIELD CONTROL ROOM

MAINS
MAINS

LEVEL
ALARM
PROBE FAILURE
SET LEVEL ALARM

RELAY ENERGISED TIME DELAY


LEVEL
RELAY DE-ENERGISED

***Continuous developments may necessiate changes without notice LF-114-0802 R3 03/02

SBEM Pvt. Ltd.


39, Electronic Co-Operative Estate, Pune–Satara Road, Pune – 411 009 (INDIA)
Tel. – 91-20-4220505, 4223375 Fax – 91-20-4215670
Email – sales@sbem.co.in, sbemsales@vsnl.com

Works: Bibwewadi Industrial Estate, 691/A/2, Pune-Satara Road, Pune-411 037(India) Email: mfg@sbem.co.in
Office MUMBAI CHENNAI NEW DELHI VADODARA
Tele. 91-22-5222824, 5242520 91-44-4451235, 4412947 91-11-6560647, 6969679 91-265-335196, 358184
Fax 91-22-5230236 91-44-4412947 91-11-6969679 91-265-330906
Email mumbai@sbem.co.in chennai@sbem.co.in newdelhi@sbem.co.in vadodara@sbem.co.in
LEVEL MEASUREMENT & CONTROL SOLUTIONS
CAPACITANCE TYPE LEVEL PROBES
FOR LIQUIDS

SBEM Pvt. Ltd. offers a wide range of level probes for


use with capacitance type level switches of series 112 &
114. The most popular range of probes for use with
liquids which cover a majority of applications are
described here. These applications includes following
conductive & non-conductive liquids.
Conductive liquids: Water, Effluent, Milk, Beer, Acids &
Alkalies etc.
Non-conductive liquids: Edible oils, Turbine oil,
Synthetic oils, Kerosene, Diesel & other petroleum
products etc.
For selection of suitable level switch refer LF-114-0802
(Single point switch) & LF-112-0801 (Two point / Dual
level switch).
The probe unit consists of an electrode and a
transducer housed in a weatherproof / flameproof probe
head. The 12 VDC supply for the transducer comes
from the switch unit. Interconnection of switch & probe
unit is done with 3 core cable.

FEATURES
ˆ Weatherproof / Flameproof probe head
ˆ Transducer moulded in epoxy for shock and
corrosion resistance
ˆ Wide range of electrodes to suit various
applications
ˆ Intrinsically safe transducer for flameproof
TRANSDUCER
applications
PROBE HEAD ˆ Packaging :
Epoxy moulded
ˆ Enclosure : ˆ Operating voltage :
Weatherproof cast aluminium polyurethane 12 VDC from switch series 112/114
painted conforming to IP-65 as per IS 2147-1962. ˆ Termination :
OR Suitable for 2.5mm2 max. Conductor size
Flameproof cast aluminium polyurethane painted ˆ Operating conditions :
conforming to Gr. IIA & IIB as per IS:2148-1981 Temperature - 0 to 550C max.
vide certificate no. V/1/1/1319, dtd.2nd March 1990 Relative Humidity - 95% max. (Non condensing)
issued by `CMRS, Dhanbad`. ˆ Transducer type :
ˆ Cable entry (1 No.): As per table below
3/4" UNF/ET (F) - Standard
1/2" NPT (F) - Optional Type Range (pf) Op.freq. Function
ˆ Process connection : (KHz)
As per the process connection in the "Electrode
Selection Guide" T910 0-200,1000,3000 100 Standard
T910C 0-20000 20 High capacitance
T910H 0-100 100 High output
T910S 0-100,500 100 Intrinsically safe
DIMENSION OF PROBE HEAD
φ 131
123 φ 131

152 115
CABLE ENTRY
EARTHING CABLE ENTRY
LUG 20 20
20 20
SLIP ON FLANGE
EARTHING LUG 1" BSP (M) THD.
Flameproof Version Weatherproof Version
ELECTRODE SELECTION GUIDE FOR CONDUCTIVE MEDIA
PROCESS MATERIAL OF TRANSD MTG. ELECTRODE HYS OPERATING
SERVICE
CONNECTION CONSTRUCTION UCER V LENGTH IN CONDITION
CODE THD INTEGRAL SENSING COUNTER H MIN MAX mm TEMP PRES
ELECTRODE DESCRIPTION TYP IN ºC Kg/cm²
NO. FLANGE ELECTRODE WEIGHT
SIZE COATING MAX MAX
MIN /LINING
11 RIGID POLYPROPELENE 01 - - 6 0 T910 V 350 3000 20 60 ATM WATER, NON-
SHEATHED CORROSIVE LIQUIDS IN
METALLIC TANKS
16 RIGID PTFE SHEATHED, Ø 16mm 01 1” 0,8 6 0 T910 V 350 3000 20 60 ATM WATER, CORROSIVE/
H 200 500 - NON CORROSIVE
LIQUIDS IN METALLIC
TANKS
17 RIGID PTFE SHEATHED, Ø 16mm 01 1” 0,8 6 0 T910 V 350 3000 20 180 10 WATER, CORROSIVE/
H 200 500 - NON-CORROSIVE
LIQUIDS IN METALLIC
TANKS
26 DOUBLE LOOP FLEXIBLE PVC 01 - - 7 2 T910/ V 3000 7000 50 60 ATM WATER IN SUMP/
SHEATHED T910HC RESERVOIRS
29 DOUBLE LOOP FLEXIBLE PTFE 01 1 ½” 0,4 6 1,6,8 T910 V 1000 5000 20 60 ATM WATER, CORROSIVE
SHEATHED (INNER LIQUIDS IN NON-
CONDUCTOR SS316) METALLIC /LINED TANKS
41 RIGID PVDF COATED Ø14mm 01 1” 0,8 6 0 T910 V 350 3000 20 140 10 MILK, BEER & OTHER
H 200 500 - FOOD PRODUCTS IN
METALLIC TANKS
77 RIGID Ø16 PTFE SHEATHED - 4” 0 6 0 T910 V 350 3000 20 60 ATM WATER BOUND
WITH Ø6 BARE EARTHING H 200 500 - SOLUTION / NON
ELECTRODE CORROSIVE LIQUIDS IN
NON METALLIC TANKS
80 RIGID Ø16 PTFE SHEATHED - 4” 0 6 0 T910 V 350 3000 20 180 10 WATER BOUND
WITH Ø6 BARE EARTHING H 200 500 - SOLUTION / NON
ELECTRODE CORROSIVE LIQUIDS IN
NON METALLIC TANKS
78 RIGID Ø16 PTFE SHEATHED - 4” 0,8 6 0 T910 V 1000 3000 20 60 ATM WATER BOUND
WITH Ø10 PTFE SHEATHED H 350 500 SOLUTION / CORROSIVE
EARTHING ELECTRODE LIQUIDS IN NON
METALLIC /LINED TANKS
81 RIGID Ø16 PTFE SHEATHED - 4” 0,8 6 0 T910 V 1000 3000 20 180 10 WATER BOUND
WITH Ø10 PTFE SHEATHED H 350 500 - SOLUTION / CORROSIVE
EARTHING ELECTRODE LIQUIDS IN NON
METALLIC/LINED TANKS
79 RIGID Ø16 PTFE SHEATHED - 2 1/2” 0 6 0 T910 V 350 3000 20 60 ATM WATER BOUND
WITH Ø6 BARE EARTHING SOLUTION / NON
ELECTRODE CORROSIVE LIQUIDS IN
NON METALLIC TANKS
82 RIGID Ø16 PTFE SHEATHED - 2 1/2” 0 6 0 T910 V 350 3000 20 180 10 WATER BOUND
WITH Ø6 BARE EARTHING SOLUTION / NON
ELECTRODE CORROSIVE LIQUIDS IN
NON METALLIC TANKS

ELECTRODE SELECTION GUIDE FOR NON-CONDUCTIVE MEDIA


PROCESS MATERIAL OF ELECTRODE OPERATING
CONNECTION CONSTRUCTION LENGTH CONDITIONS

CODE ELECTRODE INT SENSING OUTER COUNTER TRANS- MTG. HYS TEMP. PRES IN SERVICE
NO. DESCRIPTION THD. FLGD ELECTR- PIPE WEIGHT DUCER V MIN MAX mm IN 0C kg/cm2
MIN ODE H TYP MAX. MAX.

31 RIGID CONCENTRIC, PVDF 01 - 6 4,6 0 T910H V 350 800 20 140 10 EDIBLE OILS, TURBINE
COATED, 1/4" OUTER PIPE H 100 500 - OIL, KEROSENE,
33 RIGID CONCENTRIC, PTFE 01 - 6 4,6 0 T910 V 500 2000 40 60 ATM SYNTHETIC OILS &
SHEATHED,1/2" OUTER PIPE H 100 500 - OTHER PETROLEUM
34 RIGID CONCENTRIC, PTFE 01 - 6 4,6 0 T910 V 500 2000 40 180 10 PRODUCTS
SHEATHED,1/2" OUTER PIPE H 100 500 -
32 RIGID CONCENTRIC, PTFE 01 - 6 4,6 0 T910 V 1000 3000 40 60 ATM
SHEATHED,3/4" OUTER PIPE H 100 500 -
35 RIGID CONCENTRIC, PTFE 01 - 6 4,6 0 T910 V 1000 3000 40 180 10
SHEATHED,3/4" OUTER PIPE H 100 500 -
Notes :
1. V/H indicates mounting orientation : V = Vertical; H = Horizontal.
2. These are commonly used electrodes. For special applications, please contact factory.
3. High temperature stand off is recommended for process temperature above 60 deg C.
4. For food industries PVDF coated electrodes are recommended.
5. For corrosive duties, only integral flanged process connections are recommended as threaded process
connections are prone to deterioration in corrosive atmosphere.
6. Hysterisis is measured for i) Conductive liquid - Water; ii) Non conductive liquid - Kerosene. It varies as per medium.
7. For horizontal mounted electrodes 15 deg. downward angle of repose is recommended.
ORDERING CODE FOR ELECTRODE

300 mm `L'
High Temp. Stand off

PROBE TRANSDUCER PROCESS CONNECTION SENSING ELECTRODE LENGTH


HEAD ELECTRODE IN mm

9 L=

PROBE HEAD PROCESS CONNECTION PROCESS CONNECTION COATING / SHEATHING


1 - Weatherproof (WP) 01 - 1" BSP (M) MATERIAL 0 - No coating / Sheathing
1 - Polypropylene (sheathing)
4 - WP with High Temperature XX - Flange as per flange 2 - CS (For flanges only)
2 - PVC (sheathing)
Stand Off (HTSO) in SS316 table 4 - SS304 3 - PTFE (sheathing)
5 - Flameproof (FlP) 6 - SS316 8 - PVDF (coating)

FLANGE TABLE COATING / LINING


TRANSDUCER 0 - No coating / lining MATERIAL OF OUTER PIPE
00 - T 910 4 - Rubber Natural (lining) 0 - No outer pipe
Pressure rating = 150 # (10 Kg/cm2) 8 - PVDF (coating) 4 - SS304
0C - T 910 HC
6 - SS316
0H - T 910 H
ANSI BS DIN IS
0H - T910 S
1" 11 12 13 14 ELECTRODE CODE (NOTE 2)
1 1/2" 16 17 18 19 XX - As per electrode
2" 21 22 23 24 selection Guide
2 1/2" 26 27 28 29 MATL. OF COUNTER WEIGHT
MOUNTING (NOTE 1) 3" 31 32 33 34 0 - No counter weight
T - Threaded 4" 41 42 43 44 1 - Glass leadshot filled
I - Integral flange MATERIAL OF CONSTRUCTION 2 - CS Cd plated
5" 51 52 53 54 6 - SS316
S - Slip on flange 6 - SS316
6" 61 62 63 64 7 - Copper 8 - SS316 PVC coated

NOTE : 1. Slip on flanges of appropriate size can be supplied for electrodes having threaded process connections.
2. All combinations are not possible. Please refer " Electrode Selection Guide " for compatible options.

EXAMPLES :
1) 1-00-I1648-91663000 L = 500mm. 2) 5-OS-T0160-9336360 L = 1500mm.
Weatherproof probe head with Transducer T910. Flameproof probe head with IS Transducer T910S.
Integral flange, 1 1/2" ANSI in SS304, PVDF coated. 1" BSP threaded process connection in SS316.
Rigid PTFE sheathed φ16mm, SS316 Electrode Rigid concentric, SS316, PTFE sheathed electrode,
(Without outerpipe) 500mm long. 1/2" outer pipe in SS316, 1500mm long.

ELECTRODE DETAILS
Rigid Electrode Flexible Electrode Concentric Electrode Rigid Electrode with
Earthing Electrode

L + 200 (MIN) 200 (MIN) L + 200 L + 200

MIN 20 MIN 50 MIN 30 MIN 20


SPAN SPAN SPAN SPAN

`L' `L' `L' `L'


OPERATING OPERATING OPERATING OPERATING
RANGE RANGE RANGE RANGE
PERFORATED
OUTER PIPE

ZERO ZERO ZERO ZERO


MIN 20 MIN 300 MIN 20 MIN 20

MIN 20 COUNTER MIN 20 MIN 20 MIN 20


WEIGHT

Electrode code Electrode code Electrode code Electrode code


11, 16, 41,17 26, 29 31, 32, 33,34,35 77, 78, 79,80,81,82
APPLICATIONS
RIGID PTFE SHEATHED ELECTRODE WITH SHEATHED EARTHING
DOUBLE LOOP FLEXIBLE ELECTRODE FOR CONDUCTIVE LIQUID ELECTRODE FOR CONDUCTIVE & CORROSIVE LIQUID IN LINED
IN NON-METALLIC TANK TANK.
112HC331XX
112HC331XX

HI
MAINS
MAINS
PERFORATED HI HI
STILLING PIPE
(CUSTOMER`S HI
SCOPE)
LO
LO
LO

LO

RIGID CONCENTRIC SHEATHED ELECTRODE (WITH FLAMEPROOF


PROBE HEAD) FOR NON-CONDUCTIVE LIQUID RIGID PTFE SHEATHED ELECTRODE FOR CONDUCTIVE
LIQUIDS IN METALLIC TANKS

114HC131XX
114HC111XX

MAINS

HAZARDOUS SAFE
AREA AREA

RIGID PTFE SHEATHED ELECTRODE (WITH HTSO) FOR


DOUBLE LOOP FLEXIBLE ELECTRODE FOR CONDUCTIVE LIQUID IN
CONDUCTIVE LIQUID IN METALLIC TANK
NON-METALLIC TANK

112HC431XX 114HC131XX

MAINS
MAINS

HI
HI

60C TO 180C
LO LO

*** Continuous developments may necessitate changes without notice. LF-114-0803 R03 06/2002

SBEM Pvt. Ltd.


39, Electronic Co-Operative Estate, Pune–Satara Road, Pune – 411 009 (INDIA)
Tel. – 91-20-4220505, 4223375 Fax – 91-20-4215670
Email – sales@sbem.co.in, sbemsales@vsnl.com

Works: Bibwewadi Industrial Estate, 691/A/2, Pune-Satara Road, Pune-411 037(India) Email: mfg@sbem.co.in
Office MUMBAI CHENNAI NEW DELHI VADODARA
Tele. 91-22-5222824, 5242520 91-44-4452235, 4412947 91-11-6560647, 6969679 91-265-335196, 358184
Fax 91-22-5230236 91-44-4412947 91-11-6969679 91-265-330906
Email mumbai@sbem.co.in chennai@sbem.co.in newdelhi@sbem.co.in vadodara@sbem.co.in

You might also like