Difference of Setup Procedure Between MFP F/W Gxx-C8 and Older Version
Difference of Setup Procedure Between MFP F/W Gxx-C8 and Older Version
Difference of Setup Procedure Between MFP F/W Gxx-C8 and Older Version
Difference of Setup Procedure between MFP F/W Gxx-C8 and Older Version
<Difference of Setup Procedure> TABT1400458EN00
■Procedure of older ver. of Gxx-C8 (excl. Gxx-C8) ■Procedure of newer ver. of Gxx-C8
1. Adjusting touch panel 1. Time Zone Setting (Service Mode -> Stop-1-1-4-4-Clear)
2. Date/Time Setting (Administrator Settings) 2. Serial Number Input
3. Setting gradation adjustment 3. Unit Change
4. Date/Time Setting (Service Mode) 4. List Output
5. Serial number input 5. Power OFF / ON
6. Unit Change
7. List output
8. Power OFF / ON
[Key Changes]
1. Adjustment touch panel: Discontinued. The setting button is removed.
2.4.Date/Time Setting : By setting “Time Zone Setting” in the Service Mode(Stop-1-1-4-4-
Clear), Date/Time in Administrator Settings and Service Mode
will be set automatically.
3. Gradation Adjustment : Discontinued. It is set at the factory then shipped.
0
KMBT Confidential
Difference of Setup Procedure between MFP F/W Gxx-C8 and Older Version
<The Purpose of the Changes> TABT1400458EN00
<Caution>
When updating the FW of the older ver. FW of Gxx-C8 (excl. Gxx-C8) installed machine
to Gxx-C8 after open-box and then set up, due to the following reasons, the setup
cannot be finished normally , thus line(s) may occur on output image.
“Touch Panel Adjustment” described on the Installation Manual included in the box will
not be displayed.
The procedures are different from previous.
<Countermeasure>
When updating the FW of the older ver. FW of Gxx-C8 (excl. Gxx-C8) installed machine
to Gxx-C8 after open-box and then set up, please refer to the instruction which is
mentioned on the previous page as “Procedure of newer version of Gxx-C8” and
additionally, please perform the gradation adjustment.
<Subjected Models>
bizhub C554e/C454e/C364e/C284e/C224e
bizhub 554e/454e/364e/284e/224e
1
KMBT Confidential
Difference of Setup Procedure between MFP F/W Gxx-C8 and Older Version
The cut in information of the firmware of Gxx-C8 to the mass-production are mentioned as below.
The information which are not mentioned on the following list will be updated.
Cut in C454e C364e C284e C224e
C554e
Applied/Date ineo+454e ineo+364e ineo+284e ineo+224e
MF552 plus
MF452 plus MF362 plus MF282 plus MF222 plus
BUS C/I A5AY011006365 A5C0011010173 A5C1011012957 A5C2011101027 A5C4011102705
A/D 2014/2/17 2014/2/17 2014/1/23 2014/2/7 2014/2/7
BEU C/I A5AY021005261 A5C0021015222 A5C1021019277 A5C2021025087 A5C4021114955
A/D 2014/2/18 2014/2/24 2014/2/6 2014/2/11 2014/2/10
Develop C/I A5C0121001237 A5C1121001519 A5C2121003611 A5C4121103191
A/D TBD 2014/2/6 2014/2/6 2014/2/19
Olivetti C/I A5AY321000136 A5C0321000556 A5C1321000461 A5C2321001621 A5C4321100551
A/D 2014/3/7 2014/3/6 2014/2/11 2014/2/13 2014/1/23