REPORT SUMMARY Date: 11/17/2017

Page 1 of 8

In addition to this summary, this report includes the following forms:


Report Summary
Rating Criteria and Classifications
AIAG Form A
Causes
Actions
Controls

Xfmea Report Sample – Process FMEA


This report was generated with ReliaSoft Xfmea by HBM Prenscia software in Microsoft Word. Similar
reports can also be generated in Microsoft Excel. You can easily replace the Xfmea logo graphic with
your own company logo. Within Word and Excel, reports can be edited/annotated, if necessary, and
generated in PDF and/or HTML format for easy distribution.

This report includes:

• A summary of the rating criteria (Severity Scale, Occurrence Scale, Detection Scale) and
classifications that were used in the analysis.
• The Process FMEA (PFMEA) spreadsheet report in the AIAG Form A reporting format.
• A summary list of the potential causes of failure that were identified through the analysis, ranked
by Initial Occurrence rating.
• A summary list of the recommended actions identified during the analysis.
• A summary list of the current controls identified during the analysis.

The report is based on the sample analysis provided in the AIAG FMEA-3 guidelines, on page 36.

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
RATING CRITERIA AND CLASSIFICATIONS Date: 11/17/2017

Page 2 of 8

Severity Rating Scale Occurrence Rating Scale


# Description Criteria 1 Criteria 2 # Description Criteria Criteria 2
Failure is eliminated through
1 No effect No discernible effect. No discernible effect. 1 Very Low
preventative control.
Appearance or Audible Noise, vehicle
operable, item does not conform and Slight inconvenience to process, <=0.001 per thousand items/vehicles,
2 Annoyance 2 Low
noticed by discriminating customers operation or operator. 1 in 1,000,000
(<25%).

Appearance or Audible Noise, vehicle A portion of the production run may


0.01 per thousand items/vehicles, 1 in
3 Annoyance operable, item does not conform and have to be reworked in-station before it 3 Low
100,000
noticed by many customers (50%). is processed.

Appearance or Audible Noise, vehicle 100% of the production run may have
0.1 per thousand items/vehicles, 1 in
4 Annoyance operable, item does not conform and to be reworked in-station before it is 4 Moderate
10,000
noticed by most customers (>75%). processed.

Degradation of secondary function


A portion of the production run may
Degradation of Secondary (vehicle operable, but 0.5 per thousand items/vehicles, 1 in
5 have to be reworked off line and 5 Moderate
Function comfort/convenience functions at 2,000
accepted.
reduced level of performance).
Loss of secondary function (vehicle
100% of production run may have to 2 per thousand items/vehicles, 1 in
6 Loss of Secondary Function operable, but comfort/convenience 6 Moderate
be reworked off line and accepted. 500
functions inoperable).

A portion of the production run may


Degradation of primary function
have to be scrapped. Deviation from 10 per thousand items/vehicles. 1 in
7 Degradation of Primary Function (vehicle operable, but at reduced level 7 High
primary process including decreased 100
of performance).
line speed or added manpower.

Loss of primary function (vehicle 100% of the production run may have
8 Loss of Primary Function inoperable, does not affect safe vehicle to be scrapped. Line shutdown or stop 8 High 20 per thousand items/vehicles, 1 in 50
operation). ship.
Potential failure mode affects safe
Failure to Meet Safety and/or vehicle operation and/or involves May endanger operator (machine or
9 9 High 50 per thousand items/vehicles, 1 in 20
Regulatory noncompliance with government assembly) with warning.
regulation with warning.
Potential failure mode affects safe
Failure to Meet Safety and/or vehicle operation and/or involves May endanger operator (machine or => 100 per thousand items/vehicles,
10 10 Very High
Regulatory noncompliance with government assembly) without warning. => 1 in 10
regulation without warning.
Detection Rating Scale Classification Options
# Description Criteria 1 Criteria 2 Abbreviation Description

Error (Cause) prevention as a result of


fixture design, machine design or part
Detection not applicable; error
1 Almost Certain design. Discrepant parts cannot be C Critical
prevention.
made because item has been error-
proofed by process/product design.

Error (Cause) detection in-station by


automated controls that will detect Error detection and/or problem
2 Very High KI Key Intermediate
error and prevent discrepant part from prevention.
being made.

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
RATING CRITERIA AND CLASSIFICATIONS Date: 11/17/2017

Page 3 of 8

Failure Mode detection in-station by


automated controls that will detect
3 High discrepant part and automatically lock Problem detection at source. KLd Key Leading
part in station to prevent further
processing.

Failure Mode detection post-processing


by automated controls that will detect
4 Moderately High Problem detection post processing. KLg Key Lagging
discrepant part and lock part to prevent
further processing.

Failure Mode or Error (Cause) detection


in-station by operator through use of
variable gauging or by automated
5 Moderate controls in-station that will detect Problem detection at source. S Significant
discrepant part and notify operator.
Gauging performed on setup and first-
piece check (setup-causes only).

Failure Mode detection post-processing


by operator through use of variable
gauging or in-station by operator
6 Low Problem detection post processing.
through use of attribute gauging
(go/no-go, manual torque check/clicker
wrench, etc.).

Failure Mode detection in-station by


operator through visual/tactile/audible
7 Very Low means or post-processing through use Problem detection at source.
of attribute gauging (go/no-go, manual
torque check/clicker wrench, etc.).

Failure Mode detection post-processing


8 Remote by operator through Problem detection post processing.
visual/tactile/audible means.
Failure Mode and/or Error (Cause) is
9 Very Remote not easily detected (e.g., random Not likely to detect at any stage.
audits).
No current process control; Cannot
10 Almost Impossible No detection opportunity.
detect or is not analyzed.

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
POTENTIAL
FAILURE MODE AND EFFECTS ANALYSIS FMEA Number 1450
FMEA Type Component Front Door L.H. Page 4 of 8
Item 1.1.1 - Front Door L.H. Process Responsibility Body Engineering Prepared By J. Ford - X6521 - Assy Ops
Model Year(s)/Vehicle(s) 201X/Lion 4dr/Wagon Key Date 9/7/2017 FMEA Date (Orig.) 9/13/2017 (Rev) 9/22/2017
Core Team A. Tate - Body Engrg, J. Smith - OC, R. James - Production, J. Jones - Maintenance

Action Results

Classification
Name / Function
Potential Potential Current Process Current Process Responsibility &
Potential Failure Recommended

RPNi
OCCi

DETi
SEVi
Effect(s) of Cause(s) of Controls Controls Planned Actions Taken &

RPNr
OCCr

DETr
Mode Action(s)

SEVr
Failure Failure (Prevention) (Detection) Completion Date Actual Completion
Requirements Date

Front Door L.H.


Op. 70 Manual Insufficient wax Allows integrity 7 Manually inserted 8 Visual check each 5 280 Add positive depth ReliaSoft Corporation Stop added, sprayer 7 2 5 70
application of wax coverage over breach of inner spray head not hour - 1/shift for stop to sprayer. - 3/10/2017 checked on line.
inside door/ cover specified surface door panel. (7,7) inserted far enough film thickness
inner door, lower Corroded interior (depth meter) and
surfaces with wax lower door panels. coverage.
to specification (7,7)
Automate spraying. ReliaSoft Corporation Rejected due to
thickness. Deteriorated life of
- 3/10/2017 complexity of
door leading to:
different doors on
- Unsatisfactory
same line.
appearance due to
rust through paint Spray head 5 Test spray pattern Visual check each 5 175 Use Design of ReliaSoft Corporation Temp and press 1 5 35
over time clogged- Viscosity at start-up and hour - 1/shift for Experiments (DOE) - 3/10/2017 limits were
- Impaired function too high- after idle periods, film thickness on viscosity vs. determined and limit
of interior door Temperature too and preventive (depth meter) and temperature vs. controls have been
hardware (7,7) low- Pressure too maintenance coverage. pressure. installed - control
low. program to clean charts show process
heads. is in control Cpk =
1.85.
Spray head 2 Preventive Visual check each 5 70 2 5 70
deformed due to maintenance hour - 1/shift for
impact program to film thickness
maintain heads. (depth meter) and
coverage.
Spray time 8 Operator 7 392 Install spray timer. ReliaSoft Corporation Automatic spray 1 7 49
insufficient instructions and lot - 3/10/2017 timer installed -
sampling (10 operator starts
doors/shift) to spray, timer controls
check for coverage shut-off - control
of critical areas. charts show process
is in control Cpk =
2.05.

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
CAUSES Date: 11/17/2017

Page 5 of 8

Potential Cause(s) of % Reduction in Cause Last Updated Potential Failure Potential Effect(s) of
Cause ID Cause # Classification OCCi OCCr DETi DETr RPNi RPNr Last Updated Name Function
Failure RPN By Mode Failure
1 1.1.1 Manually inserted spray 8 2 5 5 280 70 75 3/12/2010 5:06 Front Op. 70 Insufficient wax Allows integrity breach of
head not inserted far PM Door Manual coverage over inner door panel. (7,7)
enough L.H. application specified surface Corroded interior lower
of wax door panels. (7,7)
inside door/ Deteriorated life of door
cover inner leading to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint
with wax to over time
specification - Impaired function of
thickness. interior door hardware (7,7)

2 1.1.2 Spray head clogged 5 1 5 5 175 35 80 3/12/2010 5:06 Front Op. 70 Insufficient wax Allows integrity breach of
- Viscosity too high PM Door Manual coverage over inner door panel. (7,7)
- Temperature too low L.H. application specified surface Corroded interior lower
- Pressure too low. of wax door panels. (7,7)
inside door/ Deteriorated life of door
cover inner leading to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint
with wax to over time
specification - Impaired function of
thickness. interior door hardware (7,7)

3 1.1.3 Spray head deformed due 2 2 5 5 70 70 0 3/12/2010 5:06 Front Op. 70 Insufficient wax Allows integrity breach of
to impact PM Door Manual coverage over inner door panel. (7,7)
L.H. application specified surface Corroded interior lower
of wax door panels. (7,7)
inside door/ Deteriorated life of door
cover inner leading to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint
with wax to over time
specification - Impaired function of
thickness. interior door hardware (7,7)

4 1.1.4 Spray time insufficient 8 1 7 7 392 49 87.5 3/12/2010 5:06 Front Op. 70 Insufficient wax Allows integrity breach of
PM Door Manual coverage over inner door panel. (7,7)
L.H. application specified surface Corroded interior lower
of wax door panels. (7,7)
inside door/ Deteriorated life of door
cover inner leading to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint
with wax to over time
specification - Impaired function of
thickness. interior door hardware (7,7)

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
ACTIONS Date: 11/17/2017

Page 6 of 8

Action Action Recommended Planned Expected Actions Last Potential Failure Potential Effect(s) of Potential Cause(s)
Responsibility Last Updated Name Function RPNi RPNr
ID # Action(s) Completion Date Completion Date Taken Updated By Mode Failure of Failure
1 1.1.1.1 Add positive depth ReliaSoft 3/10/2017 3/10/2017 Stop added, 10/31/2016 Front Op. 70 Insufficient wax Allows integrity breach Manually inserted spray 280 70
stop to sprayer. Corporation sprayer 2:17 PM Door Manual coverage over of inner door panel. head not inserted far
checked on L.H. application specified surface (7,7) enough
line. of wax Corroded interior lower
inside door/ door panels. (7,7)
cover inner Deteriorated life of
door, lower door leading to:
surfaces - Unsatisfactory
with wax to appearance due to rust
specification through paint over time
thickness. - Impaired function of
interior door hardware
(7,7)
2 1.1.1.2 Automate spraying. ReliaSoft 3/10/2017 3/10/2017 Rejected 10/31/2016 Front Op. 70 Insufficient wax Allows integrity breach Manually inserted spray 280 70
Corporation due to 2:17 PM Door Manual coverage over of inner door panel. head not inserted far
complexity L.H. application specified surface (7,7) enough
of different of wax Corroded interior lower
doors on inside door/ door panels. (7,7)
same line. cover inner Deteriorated life of
door, lower door leading to:
surfaces - Unsatisfactory
with wax to appearance due to rust
specification through paint over time
thickness. - Impaired function of
interior door hardware
(7,7)
3 1.1.2.1 Use Design of ReliaSoft 3/10/2017 3/10/2017 Temp and 10/31/2016 Front Op. 70 Insufficient wax Allows integrity breach Spray head clogged 175 35
Experiments (DOE) Corporation press limits 2:16 PM Door Manual coverage over of inner door panel. - Viscosity too high
on viscosity vs. were L.H. application specified surface (7,7) - Temperature too low
temperature vs. determined of wax Corroded interior lower - Pressure too low.
pressure. and limit inside door/ door panels. (7,7)
controls cover inner Deteriorated life of
have been door, lower door leading to:
installed - surfaces - Unsatisfactory
control with wax to appearance due to rust
charts show specification through paint over time
process is in thickness. - Impaired function of
control Cpk interior door hardware
= 1.85. (7,7)
4 1.1.4.1 Install spray timer. ReliaSoft 3/10/2017 3/10/2017 Automatic 10/31/2016 Front Op. 70 Insufficient wax Allows integrity breach Spray time insufficient 392 49
Corporation spray timer 2:16 PM Door Manual coverage over of inner door panel.
installed - L.H. application specified surface (7,7)
operator of wax Corroded interior lower
starts spray, inside door/ door panels. (7,7)
timer cover inner Deteriorated life of
controls door, lower door leading to:
shut-off - surfaces - Unsatisfactory
control with wax to appearance due to rust
charts show specification through paint over time
process is in thickness. - Impaired function of
control Cpk interior door hardware
= 2.05. (7,7)

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
CONTROLS Date: 11/17/2017

Page 7 of 8

Potential Cause(s) of
Control ID Control # Current Process Controls Control Type Last Updated By Last Updated Name Function Potential Failure Mode Potential Effect(s) of Failure RPNi RPNr
Failure
1 1.1.1.1 Visual check each hour - Detection 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Manually inserted spray head 280 70
1/shift for film thickness Door L.H. Manual over specified surface door panel. (7,7) not inserted far enough
(depth meter) and application Corroded interior lower door
coverage. of wax panels. (7,7)
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

2 1.1.2.1 Test spray pattern at start- Prevention 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Spray head clogged 175 35
up and after idle periods, Door L.H. Manual over specified surface door panel. (7,7) - Viscosity too high
and preventive maintenance application Corroded interior lower door - Temperature too low
program to clean heads. of wax panels. (7,7) - Pressure too low.
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

1 1.1.2.2 Visual check each hour - Detection 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Spray head clogged 175 35
1/shift for film thickness Door L.H. Manual over specified surface door panel. (7,7) - Viscosity too high
(depth meter) and application Corroded interior lower door - Temperature too low
coverage. of wax panels. (7,7) - Pressure too low.
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

3 1.1.3.1 Preventive maintenance Prevention 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Spray head deformed due to 70 70
program to maintain heads. Door L.H. Manual over specified surface door panel. (7,7) impact
application Corroded interior lower door
of wax panels. (7,7)
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com
CONTROLS Date: 11/17/2017

Page 8 of 8

1 1.1.3.2 Visual check each hour - Detection 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Spray head deformed due to 70 70
1/shift for film thickness Door L.H. Manual over specified surface door panel. (7,7) impact
(depth meter) and application Corroded interior lower door
coverage. of wax panels. (7,7)
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

4 1.1.4.1 Operator instructions and lot Detection 3/12/2010 5:06 PM Front Op. 70 Insufficient wax coverage Allows integrity breach of inner Spray time insufficient 392 49
sampling (10 doors/shift) to Door L.H. Manual over specified surface door panel. (7,7)
check for coverage of critical application Corroded interior lower door
areas. of wax panels. (7,7)
inside door/ Deteriorated life of door leading
cover inner to:
door, lower - Unsatisfactory appearance
surfaces due to rust through paint over
with wax to time
specification - Impaired function of interior
thickness. door hardware (7,7)

Non-proprietary and non-confidential information.


Date Created: 11/17/2017 Creator: HBM Prenscia Generated by ReliaSoft Xfmea http://www.reliasoft.com