Professional Documents
Culture Documents
Design A Beams by Eurocode
Design A Beams by Eurocode
REF OUTPUT
Φ
Dimension:
Span , L 8000
width, B 3000
Slab Thickness 110
Beam size 225 500 mm
Characteristic loads
Finishes etc 1.5 KN/m2
Variable, qk 3 KN/m2
Materials:
Unit weight of concrete 25 KN/MM3
Characteristic strength of concrete, fck 25 KN/mm2
Characteristic strength ofsteel, fyk 500 KN/mm2
Characteristic strength of link, fyk 500 KN/mm2
Nominal concrete cover 30 mm
Assumed :
Φbar1 = 20 mm
Φbar2 = 12 mm
Φlink = 6 mm
5.3.2.1
b = b1 + b 2 + b w = 3025 mm
LO = 0.7 X L 5600
beff , = ∑ b eff , I + bw < b 1905 1905
beff , 1 0.2b
= i + 0.1l0 < 0.2lo 840 840
beff , 1 0.2b
= i + 0.1l0 < 0.2lo 840 840
Span 4-5
b = b1 + b 2 + b w = 3025 mm
LO = 0.85 X L 6800
beff , = ∑ b eff , I + bw < b 2145 2145
beff , 1 0.2b
= i + 0.1l0 < 0.2lo 960 960
3
beff , 1 0.2b
= i + 0.1l0 < 0.2lo 960 960
ACTIONS
Actions on slab:
Self-weight = 2.75 KN/m2
Finishes 1.5 KN/m2
Characteristic permanent load, g k 4.25 KN/m2
characteristic variable load, qk 3 KN/m2
Actions of beamC/A-D
MAIN REINFORCEMENT
Span 1-2
Effective depth , d = h-cnom - Φlink - 0.5Φbar = 454 mm
Bening moment,
M = 193.68 KNm
Mf = 0.567fck bhf(d-0.5hf)
1334.4919088 KNm
M > Mf
Neutral axis within flange
k = M/fck bd2
= 0.0175228912
As,min = (0.26(fctm/fyk)bd
= 135.98208 135.98208 mm2
support 2
5
M = 237 KNm
k = M/fck bd2
= 0.2137272408
Redistribution =
k < Kbal
compression reinforcement is required
x = (d-z)/0.4
= 199.0139346
= 4500 mm
span 2-4
Effective depth , d = h-cnom - Φlink - 0.5Φbar = 454
M= 151 kNm
Bening moment,
M = 150.64 KNm
Mf = 0.567fck bhf(d-0.5hf)
= 1185.1781288
M < Mf
Neutral axis within flange
k = M/fck bd2
= 0.0153459441
M = 237 KNm
k = M/fck bd2
= 0.2137272408
Redistribution =
k < Kbal
compression reinforcement is required
x = (d-z)/0.4
= 199.0139346
span4-5
Effective depth , d = h-cnom - Φlink - 0.5Φbar = 454
M= 151 kNm
Bening moment,
M = 193.68 KNm
Mf = 0.567fck bhf(d-0.5hf)
= 1334.4919088
M < Mf
Neutral axis within flange
k = M/fck bd2
= 0.0175228912
SHEAR REINFORCEMENT
6.2.3 Concrete strut capacity
Support 1
Ved = 0.45 F
= 0.45*269
= 121.05 KN
< vRd, max cotθ =2.5
< vRd, max cotθ =1.0
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 150.102 KN
Med , max / z =
449.06097844 KN > ΔFtd
Support 2
Ved = 0.60 F
= 0.60*269
= 161.4 KN
< vRd, max cotθ =2.5
10
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 200.136 KN
Med , max / z =
449.06097844 KN > ΔFtd
Ved = 0.55 F
= 0.55*269
= 147.95 KN
< vRd, max cotθ =2.5
< vRd, max cotθ =1.0
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 183.458 KN
Med , max / z =
449.06097844 KN > ΔFtd
Support 4
Ved = 0.55 F
= 0.55*269
= 147.95 KN
< vRd, max cotθ =2.5
< vRd, max cotθ =1.0
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 183.458 KN
12
Med , max / z =
449.06097844 KN > ΔFtd
Ved = 0.6 F
= 0.6*269
= 161.4 KN
< vRd, max cotθ =2.5
< vRd, max cotθ =1.0
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 200.136 KN
Med , max / z =
449.06097844 KN > ΔFtd
Ved = 0.45F
= 0.45*269
= 121.05 KN
< vRd, max cotθ =2.5
13
try link : H 6
6.2.3(7)
Additioinal longitudinal reinforcement
additional tensile force,
ΔFtd = 0.5V ed cot Φ
= 150.102 KN
Med , max / z =
449.06097844 KN > ΔFtd
9.2.2(5)
minimum links
Link arrangement
x1 = 118.66160072 m
x2 = 159.01160072 m
x4 = 145.56160072 m
x5 = 118.66160072 m
-1
θ = 0.5*sin [ved /0.2fck(1-fck/250)]
= 7.4169034469 °
use : θ = 26.5 tan θ = 0.4985816
cot θ = 2.006
transverse shear reinforcement
Asf /sf = ved hf /0.87 fyk cotθ
15
= 0.1452286919
Spacing , sf = 540.80096237 mm
7.4 DEFLECTIOIN
Percentage of required tension of reinforcement
ρ = As,required / bd
= 0.010105963
ρ' = As',required / bd = 0
ρ > ρo #NAME?
157mm2/m)