Professional Documents
Culture Documents
Perhitungan Diameter Dan Daya Pompa
Perhitungan Diameter Dan Daya Pompa
Principal Dimension :
Lpp : 87 m T : 5,4 m
B : 14 m Cb : 0,78
H : 7,4 m
Bilga pump:
Menghitung diameter pipa :
dH =3,0 √ ( B+ H ) L+35
dH = 163,2 mm
Q = 153,14 m3/h
Menghitung H pompa :
H=H+2
H = 7,4 + 2 = 9,4
Q xϒ x H
HP =
75 x 60 x 60 x η
HP = 6,42 HP
Ballast pump :
menghitung kapasitas pompa ballast :
dH = 163,2 mm
Q=vxA
Menghitung H pompa :
H = T – 0,3
Q xϒ x H
HP =
75 x 60 x 60 x η
HP = 3,48 HP
Hydrant pump :
Menghitung H pompa :
H = H + 12
= 7,4 + 12 = 19,4 m
Q = 150,35 m3/h
Q xϒ x H
HP =
75 x 60 x 60 x η
150,35 x 1025 x 19,4
HP =
75 x 60 x 60 x 0,85
HP = 13,027 HP