1 No. Ver Bracing Required As Drawn MKD' - 2Vb-27: Bolt List For Assembly MKD' 2Vb-27 X 1 Dia. Qty. Bolt Grade
1 No. Ver Bracing Required As Drawn MKD' - 2Vb-27: Bolt List For Assembly MKD' 2Vb-27 X 1 Dia. Qty. Bolt Grade
REMARKS
DESCRIPTION WIDTH LENGTH MATERIAL QTY.
MARK NO. IN Kgs IN Kgs IN Kgs
2VB-27 4-5/A 15.516
A-207 L75X75X6 5541 ASTM-A36 2 6.87 38.28 76.56
P-423 10 THK. PLT. 75 95 ASTM-A36 6 7.85 0.56 3.36
79.91 KGS
2VB-27 x 1 GRAND TOTAL WT. 79.91 KGS
6500
A-207
12
A-207
1383
2283
3183
4083
4983
5541
483
TYP
2*D18 P-423 P-423 P-423 P-423 P-423 P-423
10
40
TYP
95
40
A-207 75 A-207
2*D18
TYP
A
REFERENCE DRAWING:
35 5351 60 KSS021-D-1391
0
5446
60 35
35
95
5506
NOTES :-
1) ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS ARE IN METERS.
5541
2) ALL BOLT HOLES SHALL BE Ø 22 FOR M20 BOLTS (U.N.O.)
3) ALL WELDS SHALL BE 6mm CONTINUOUS FILLET WELD (U.N.O.)
4) DENOTES SHOP MARK SHALL BE PROVIDED BY THE FABRICATOR ON
FLANGE OF MEMEBER/FACE OF PLATES ON EACH ASSEMBLY AS SHOWN,
ON SHOP DETAIL DRAWINGS SAME IS TO BE REFFERD FOR ORIENTATION,
A-207 DURING ERECTION OF THE ASSEMBLY.
10
TYP
95 P-423
1 12-02-2014 GENERALLY REVISED & ISSUED FOR FABRICATION ABG SAJ SAJ