TI Schöck Dorn/GB/2018.1/January 43
Schöck Dorn type LD
LD ⌀ S-A4
The dowel and the sleeve are made of stainless steel. This dowel system is particular-
ly suited for structural component joints with frequent movement such as, for
example, in the exterior of buildings.
LD ⌀ P-A4 or LD ⌀ P-Zn
The sleeve of this set is made of plastic and can be combined with a dowel made from
stainless steel (A4) or hot galvanised carbon steel (Zn). This dowel system is especially
suitable for structural joints with less movements such as, for example, in the interior
of buildings.
x
LD-Q ⌀ S-A4
The dowel and the laterally movable sleeve are made of stainless steel. This dowel
LD system allows displacement of structural components axially and transversely to the
y dowel axis and can be employed in interior and exterior areas.
LD ⌀ F-A4 or LD ⌀ F-Zn
The dowel is available in stainless steel (A4) or hot galvanised carbon steel (Zn). The
one-sided sleeve, made of plastic, is already assembled. This dowel system is
primarily employed with concealed joints in road construction or with foundation
slabs, if both sides of the expansion joint are concreted in one step.
x
44 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
LD ⌀ Part A4 or LD ⌀ Part Zn
The dowel is available in stainless steel (A4) or hot galvanised carbon steel (Zn). The
hot galvanised dowel should be employed in dry interior areas of buildings only.
LD ⌀ Part S
The sleeve is made of stainless steel with a mounting nail plate for fixing to the
formwork. This sleeve can be combined with the stainless steel Dowel LD Part A4 only
and is particularly suitable for structural component joints with frequent movement
such as, for example, in the exterior area.
LD ⌀ Part P
The sleeve and the mounting plate are made of plastic. The sleeve can be fixed simply
to the formwork using the mounting plate. The sleeve can be combined with a LD
stainless steel (A4) dowel or hot galvanised carbon steel (Zn) dowel and is particularly
suitable for the joints of structural components with less movements in the interior
area of buildings.
LD-Q ⌀ Part S
The rectangular sleeve is made of stainless steel and can be combined with the
stainless steel (A4) dowel. It can be used in structural component joints in interior and
exterior areas, if movements axially and transverse to the dowel axis are to be
expected.
TI Schöck Dorn/GB/2018.1/January 45
Schöck Dorn type LD
Dowel Sleeve
Category Typical examples
Part A4 Part Zn Part S Part P
Within buildings
Heated buildings with neutral atmos-
LD C1 ✓ ✓ ✓ ✓
pheres (offices, schools, hotels)
Unheated buildings, in which condensa-
C2 ✓ - ✓ ✓
tion can occur (storage, sports halls)
Production rooms with high air humidity
C3 and some air pollution (food production, ✓ - ✓ ✓
laundries, breweries)
C4 Chemical plants, swimming pools - - - -
Exterior areas
C2 Rural climate ✓ - ✓ ✓
City and industrial atmospheres with
C3 moderate air pollution, coast with low ✓ - ✓ ✓
salt content
Industrial areas, coastal areas with
C4 - - - -
moderate salt content
Dowel Sleeve
Schöck Dorn type LD / LD-Q
Part A4 Part Zn Part S Part P
Yield strength fyk ≥ 690 N/mm² fyk ≥ 690 N/mm² fyk ≥ 235 N/mm² -
Application areas
The Schöck Dorn type LD is technically approved at European level for the transmission of mainly latent loadings in expansion
joints. The European Technical Assessment ETA 16/0545 regulates the dimensioning according to the harmonised product stand-
ard ETAG 030 for the concrete strength classes C20/25 to C50/60. The joint width can vary between 10 and 60 mm. In accordance
with harmonised European product standard ETAG 030 only the Schöck Dorn type LD ⌀ S-A4 can be used as stability component
between two building parts as only this dowel can transmit horizontal forces. The employment of the Schöck Dorn type LD under
earthquake or fatigue loads, is not regulated in the assessment.
All following design and reinforcement tables have been determined with a concrete cover of 20 mm.
46 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
Fig. 36: Schöck Dorn type LD: Minimum structural component dimensions and dowel spacings for a slab
0.5 hmin
ev,min
bw
0.5 hmin
bu
Fig. 37: Schöck Dorn type LD: Minimum structural component dimesnions Fig. 38: Schöck Dorn type LD: Minimum structural component thickness of a
and dowel spacings on the front face of a beam or a wall wall or column
TI Schöck Dorn/GB/2018.1/January 47
Schöck Dorn type LD
eR eh eR eR eh eR
Fig. 39: Schöck Dorn type LD: Perimeter dependent on the critical dowel spacing and edge distance
48 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
LD
TI Schöck Dorn/GB/2018.1/January 49
Schöck Dorn type LD
The following design values were determined according to BS EN 1992-1-1 (EC2) using a concrete cover of 20 mm. With high con-
crete cover the load-bearing capacity for an appropriately reduced slab height must be used. The maximum load-bearing capaci-
ties listed here apply only in connections with a reinforcement arrangement in accordance with pages 52 and under observance
of the critical dowel spacings/edge distances in accordance with page 48.
50 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
The following design values were determined according to BS EN 1992-1-1 (EC2) using a concrete cover of 20 mm. With high con-
crete cover the load-bearing capacity for an appropriately reduced slab height must be used. The maximum load-bearing capaci-
ties listed here apply only in connections with a reinforcement arrangement in accordance with pages 52 and under observance
of the critical dowel spacings/edge distances in accordance with page 49.
TI Schöck Dorn/GB/2018.1/January 51
Schöck Dorn type LD
On-site reinforcement
On-site reinforcement
All load-bearing levels of the Schöck Dorn type LD respectively require only one slip-in stirrup right and left of the dowel as well
as a longitudinal reinforcement bar (Asy) at the top and bottom edge of the slab.
Section View
Asy Asx
≥ hmin
≥ hmin
Asy
lc1
lb,rqd 1.5 dm ≤ 30 lb,rqd lc1 + 3 dm lb,rqd
52 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
On-site reinforcement
Section 4
ev
cnom
⌀ ASX < 45
°
< ev - cnom - 2 ⌀ASX
Fig. 41: Schöck Dorn type LD: Position of the longitudunal reinforcement in relation to the front face of the slab
LD
Hazard note - separation longitudinal reinforcement to front face too large
▶ If the longitudinal reinforcement is too far removed from the front face the concrete edge can break off and the structural
component cratered.
▶ The distance between main bars and front face of the slab must be checked after installation.
TI Schöck Dorn/GB/2018.1/January 53
Schöck Dorn type LD
Product description
L/2 20
d
d
L L
Fig. 42: Schöck Dorn type LD Part A4, LD Part Zn: Dimensions of the dowel Fig. 43: Schöck Dorn type LD F-A4, LD F-Zn: Dimensions of the dowel with
plastic sleeve
LD
D
D
C
A
B B A
Fig. 44: Schöck Dorn type LD Part S, LD Part P: Dimensions of the sleeve, Fig. 45: Schöck Dorn type LD-Q Part S: Dimensions of the laterally movable
stainless steel and plastic sleeve
54 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
VEd ≤ VRd
VRd = min ( VRd,ct; VRd,c; VRd,s )
with:
VEd - design value of the shear force
VRd - design resistance of the dowel connection
VRd,ct - design resistance against punching shear failure
VRd,c - design resistance against concrete edge failure
VRd,s - design resistance against steel failure of the dowel
These verifications are necessary if the constraints for the design tables are not observed. The punching shear design must be car-
ried out if the critical spacings in accordance with page 48 are undercut or the on-site reinforcement in accordance with page
52 has been modified. The load-bearing capacity of the concrete edge must be additionally checked if the on-site reinforcement
deviates from the recommendations on page 52.
TI Schöck Dorn/GB/2018.1/January 55
Schöck Dorn type LD
30 + 1,5 · dm
1.5 · dm lc1 1.5 · dm 1.5 · dm 1.5 · dm 1.5 · hmin ≤ eh ≤ 3 · dm + lc1 1.5 · dm
e > 3 · dm + lc1 lc1/2 eR ≥ eR,min lc1/2 lc1/2
Fig. 46: Schöck Dorn type LD: Lengths of the perimeter for the punching shear design depending on the dowel spacings
View Section
lc1
LD Asx
Asy
dm
hmin
Asy
Asx
by = lc1 + 2 · 1,5 dm bx = 30 + 1.5 · dm
Fig. 47: Schöck Dorn type LD: Dimensions of the punching area
56 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
View
lc1/2 lc1/2
l1'
l1
c1
33° 33°
ξ · ds
cnom
Asx
Fig. 48: Schöck Dorn type SLD: Dimensions of the breakout cone of the con- LD
crete edge
with: X1 = 0.61
X2 = 0.92
ψi - coefficient to take into account the the spacing of the suspended reinforcement from
the dowel
ψi = 1 - 0.2 ( lci / 2 ) / c1
lci/2 - distance Asx,i from the dowel of the suspended reinforcement considered
lc1 - distance of the first stirrup row from the dowel, see page 52
c1 - edge distance starting from the dowel centre up to the free edge
Asx,i - cross-section of a leg of the suspended reinforcement in the break out cone
fyk - characteristic yield strength of the suspended reinforcement
fck = 30 N/mm² (for all concrete classes in accordance with ETA 16/0545)
γc - γc = 1.5
TI Schöck Dorn/GB/2018.1/January 57
Schöck Dorn type LD
Design example
Connection of a floor slab to a wall
Concrete: C25/30
Slab thickness: h = 200 mm
Wall thickness: bw = 300 mm
Concrete cover: cnom,u = cnom,o = 20 mm
Design value of the shear force: vEd = 35 kN/m
Joint length lf = 5.0 m
Joint width on installation: fE = 20 mm
Maximum joint opening: f = 32 mm
Environmental conditions: Joint inside a heated building category C1
The maximum joint opening to be expected is relevant for the design of the Schöck Dorn type LD. This dimension can be deter-
mined through superimposition of the deformations from the shrinkage, loading and temperature changes which occur. Further
information on the calculation of maximum joint width is given on page 12.
In accordance with ETA 16/0545, for the design, the maximum joint opening to be expected must be rounded up to a full 10 mm.
For this reason in the following design a maximum joint width of 40 mm is assumed.
bw
LD
Selection of the suitable materials for the dowel and the sleeve
Determination of the materials in accoordance with page 46:
Constraints: Environment Category C1 interior area, no horizontal bracing in the joint
Sleeve material: Plastic (Part P)
Dowel material: Galvanised engineering steel (Part Zn)
Seletion of the dowel diameter on the basis of the design tables page 50:
Constraints: slab height = 200 mm and joint width = 40 mm
selected: LD 25 P-Zn
Load-bearing capacity LD 25: VRd, LD 25 = 31.3 kN ≤ VEd, LD = 43.8 kN
The dowel spacing must be reduced
58 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
Design example
Determination of optimum dowel spacings:
Maximum dowel spacing: eh,max,LD 25 = VRd,LD / vEd = 31.3 / 35 ≈ 0.89 m
Required number of dowels: nDorn = lf / eh,max,LD 25 = 5.0 / 0.89 = 5.62 ≈ 6 dowels
Dowel spacing: eh,LD 25 = lf / nDorn= 5.0 / 6 = 0.84 m
Loading per dowel: VEd,LD 25 = eh,LD 25 vEd = 0.84 35 = 29.4 kN
Checking of the minimum structural component dimensions in accordance with page 47:
Minimum slab thickness: hmin = 180 mm ≤ h = 200 mm
Minimum wall thickness: bw,min = 280 mm ≤ bw = 300 mm
Checking of the critical dowel spacing and edge separation in accordance with page 48:
Critical dowel spacing: eh,crit = 580 mm ≤ eh,LD 25 = 840 mm
Critical edge separation: eR,crit = 340 mm ≤ eR = eh,LD 25 / 2 = 840 / 2 = 420 mm
Thus all constraints for the application of the design tables are observed and no further verification for the dowel connection is
required. The reinforcement along the slab edge and in the slab must be verified separately.
For information the detailed verification of the dowel connection is carried out below. LD
TI Schöck Dorn/GB/2018.1/January 59
Schöck Dorn type LD
Design example
Concrete edge failure
Load-bearing capacity: VRd,ce = ΣVRd,1,i + ΣVRd,2,i ≤ Σ Asx,i fyd
Hook load-bearing capacity: VRd,1,i = 0.61 0.92 ψi Asx,i fyk ( fck / 30 ) 1/2 / γc
with: ds = 10 mm
ξ = 3 for ds
cnom = 20 mm
LD fbd = 2.7 N/mm²
l1 = h / 2 - ξ ds - cnom
l1 = 200 / 2 - 3 10 - 20 = 50 mm
l’i = l1 - (lci / 2 ) tan 33°
Verificatons
Punching through flat slabs: VRd,ct = 46.6 kN ≥ VEd,LD 25 = 29.4 kN
Concrete edge fracture: VRd,ce = 31.94 kN ≥ VEd,LD 25 = 29.4 kN
Steel failure: VRd,s = 42.0 kN ≥ VEd,LD 25 = 29.4 kN
View
6 LD 25 P−Zn
2 ⌀ 10 1⌀10
200
1⌀10
70 70 70 70
840 840 840 840 840
60 TI Schöck Dorn/GB/2018.1/January
Schöck Dorn type LD
Installation instructions
1 2A
LD ⌀ Part P
LD ⌀ Part S
LD-Q ⌀ Part S
2B
LD
LD ⌀ BSM
LD-Q ⌀ BSM
LD ⌀ Part A4
LD ⌀ Part Zn
2C
TI Schöck Dorn/GB/2018.1/January 61
Schöck Dorn type LD
Installation instructions
5 10
A B
LD 6 11A 11B
≈ 30 mm ≈ 30 mm
l0 l0
7 12
8 13
62 TI Schöck Dorn/GB/2018.1/January