Q = 265kW
Q=UAF∆TAM
(484.962+136.754 ) (35.122+219.951)
∆ T AM = -
2 2
= 183.3215℃
Q
A =
UF ∆ T lm
265
=
(30)(0.9)(183.3215)
= 53.5544m2
D = 8.25758m
H = 16.515 m
π D2
V= H
4
π (8.25758)2
= (16.515)
4
= 884.434m3
E101
Q = 394kW
Q=UAF∆TAM
π D2
29.71032 =
4
D = 6.1505m
H = 12.301m
π D2
V= H
4
π (6.1505)2
= (12.301)
4
=365.47m3