Professional Documents
Culture Documents
IECEx UL09 0025 - NFMV
IECEx UL09 0025 - NFMV
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Marking: Ex nR II T5
Ex nR II T3
Ex tD A21 IP66 T100°C
Ex tD A21 IP66 T200°C
Signature:
(for printed version)
Date:
Page 2 of 5
Manufacturing location(s):
Cooper Crouse- Cooper Crouse- Cooper Crouse- Cooper Electrical Cooper Electronic
Hinds Hinds Korea Co, Hinds SA Australia Pty. Ltd. Technologies
AV Javier Rojo Ltd. Avda Santa Eulalia 205-209 Woodpark (Shanghai) Co Ltd
Gomez No 1170 106-4 Dwoong-Ri 290 Road 955 Shen Li Road
CP 09300 Dochuk-Myun E-08223 Terrassa Smithfield NSW 2164 Heqing Pudong
Mexico City Kwangji-Si (Barcelona) Australia Shanghai 201201
Mexico Kyunggi-Do Spain China
Korea, Republic of
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and
found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products
covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This
certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents
as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified
documents, was found to comply with the following standards:
IEC 60079-0 : 2004 Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
Edition: 4.0
IEC 60079-15 : 2005- Electrical apparatus for explosive gas atmospheres Part 15: Construction, test and Marking
03 of Type of Protection "n" electrical apparatus
Edition: 3
IEC 61241-0 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General
Edition: 1 requirements
IEC 61241-1 : 2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by
Edition: 1 enclosures "tD"
This Certificate does not indicate compliance with electrical safety and performance requirements other than those
expressly included in the Standards listed above.
Test Report:
US/UL/ExTR09.0027/00 US/UL/ExTR09.0027/01 US/UL/ExTR09.0027/02
US/UL/ExTR09.0027/03
Page 3 of 5
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
NFMV Series floodlights consists of aluminium restricted breathing enclosure with a glass cover. The glass cover is
attached to the body of the floodlight by two hinges and sercured by six cover screws. A yoke mounting bracket is
secured into two blind holes on teh enclosure allowing the floodlight to be mounted 30° past vertical, 60° before vertical
or at 90°. The yoke mount is attached to a pole mount with a SFA6 Slipfitter. The enclosure is provided with two conduit
openings.
Nomenclature for Type NFMV Series:
NFMV M Y 400 /220 60 76 M20
I II III IV V VI VII
I - Series
NFMV
II - Lamp/Function
M - Metal Halide (M - H)
S - High Pressure Sodium (HPS)
III - Mounting
Y - Yoke
CONDITIONS OF CERTIFICATION: NO
IECEx Certificate
of Conformity
Certificate No.: IECEx UL 09.0025
Page 4 of 5
EQUIPMENT(continued):
IV - Wattage
150 - 150 W (HPS only)
250 - 250 W
400 - 400 W
V - Voltage
/220 60 - 220 V, 50 Hz
/230 50 - 230 V, 50 Hz
/230 60 - 230 V, 60 Hz
/240 50 - 240 V, 50 Hz
/240 60 - 240 V, 60 Hz
VI - Optical Distrubution
76 - NEMA 7X6 Beam Spread
VII - Suffixes
M20 - 20mm metric threads for conduit opening (supplied with one plug and one cable gland)
M25 - 25mm metric threads for conduit opening (supplied with one plug and one cable gland)
S714 - Furnished with lamps (lamp not installed in lampholder)
S886 - Two conduit/cable glands of like thread installed
S831 - Retention cable
FA - Factory assembled, lamp installed in lampholder (this suffix is always last in string)
Note: Standard conduit machining is two 3/4 NPT threaded entries with one cable gland and one plug installed.
IECEx Certificate
of Conformity
Certificate No.: IECEx UL 09.0025
Page 5 of 5