PROJECT : PROPOSED GATE AND PERIMETER FENCE

LOCATION : NURSERY ROAD, BRGY. KATANGAWAN, GENERAL SANTOS CITY


OWNER : KERWIN WILLIAM TAN

GENERAL NOTES AND SPECIFICATIONS

1. GENERAL SCOPE OF WORKS

THE WORK CONSIST OF LABOR AND EQUIPMENT NECESSARY FOR


CONSTRUCTION AND TO COMPLETE THE PROPOSED BUILDING AS SHOWN
ON THE PLANS AND SPECIFICATIONS THERE-IN.

2. LOCATION

THE BUILDING SHALL BE STAKE-OUT AND THE GRADES ESTABLISHED AS


SHOWN ON THE DRAWINGS AND IN ACCORDANCE WITH THE LOCAL
BUILDING CODE. ALL FILL SHALL BE IN LAYERS NOT EXCEEDING 0.20
METERS (8”) THICKNESS EACH LAYER BEING THOROUGHLY COMPACTED
AND TAMPERED OR ROLLED.

3. CONCRETE AND MASONRY WORKS

CEMENT: PORTLAND CEMENT OF ANY ACCEPTED BRAND.

FINE AGGREGATE: WASHED SAND, STONE SCREENINGS, OR OTHER


INERT MATERIALS WITH SIMILAR CHARACTERISTICS, OR
COMBINATION THEREOF, HAVING CLEAN, HARD, STRONG, DURABLE,
UNCOATED GRAINS, AND FREE FROM INJURIOUS MATTERS.

COARSE AGGREGATE: CRUSHED STONES, GRAVEL OR OTHER APPROVED


INERT MATERIALS WITH SIMILAR CHARACTERISTICS, OR A COMBINATION
THEREOF FREE FROM INJURIOUS ORGANIC OR LETORIOUS MATTER

STEEL REINFORCEMENT: STEEL BARS FOR CONCRETE REINFORCEMENT


SHALL CONFORM TO THE REQUIREMENTS OF STANDARD SPECIFICATIONS
FOR “BILLET STEEL CONCRETE REINFORCEMENT BARS” OF OUR LOCAL
BUILDING CODE.

CONCRETE PROPORTIONS:
A. CLASS “A” CONCRETE (1:2:4) - For all footings, columns, beams, girder, slabs.
B. CLASS “B” CONCRETE (1:3:4) - For all slabs on fill.
C. CEMENT MORTAR (1:2) - For 2 cm. thick plaster
D. CEMENT MORTAR (1:4) - For CHB filler or mortar.

CONCRETE HOLLOW BLOCKS (CHB):


A. 8” x 16” x 4” - Interior walls as indicated in the plans
B. 8” x 16” x 6” - Exterior walls as indicated in the plans

4. CARPENTRY AND JOINERY WORKS

ALL TIMBER SHALL BE FREE FROM LARGE LOOSE KNOTS, ROTS AND
SHAKES OR OTHER IMPERFECTION TENDING TO ITS STRENGTH AND
DURABILITY.

5. ELECTRICAL WORKS

ALL ELECTRICAL INSTALLATION SHALL BE DONE IN ACCORDANCE WITH


THE LATEST PROVISIONS ON THE NATIONAL ELECTRICAL CODE OF THE
PHILIPPINES AND SHALL COMPLY WITH ALLTHE LAWS AND REGULATIONS
APPLICABLE TO THE NATURE OF WORK PRESENTLY AND ENFORCED BY
LOCAL AUTHORITIES. ALL WIRINGS SHALL BE CONCEALLED AND ALL
ELECTRICAL DEVICES SHALL BE OF THE KIND AND QUALITY.

6. PLUMBING WORKS

A. PLUMBING LAYOUT SHALL BE IN ACCORDANCE WITH THE PLANS AS


APPROVED BY THE LOCAL AUTHORITY AND SHALL CONFORM IN
EVERY RESPECT TO THE NATIONAL PLUMBING CODE.
B. ALL PVC PIPES SHALL BE OF APPROVED QUALITY. ALL VENTS, TRAPS,
CLEANOUTS, AND ELBOW DRAINS SHALL BE PROVIDED AND LOCATED
IN ACCORDANCE WITH THE PLUMBING CODE AND AS SHOWN.
C. ALL PIPES FOR WATER SERVICES SHALL BE POLYVINYL CHLORIDE
(PVC) OF APPROVED QUALITY. SIZES SHALL BE AS INDICATED ON
PLANS.
D. SEPTIC TANK SHALL BE AS PER PLANS AND MUST BE BUILT IN
WATERTIGHT.
E. WATER PIPINGS SHALL BE ¾” DIA. PVC PIPE FROM GSCWD LINE TO
METER AND ½” DIA.PVC PIPE THE REST OF THE SYSTEM.
F. DRAINAGE SYSTEM SHALL BE PROVIDED FOR EVERY DOWNSPOUT,
CONCRETE INLET AND 4” DIA CONCRETE LEADING TO MAIN DRAINAGE
SYSTEM.

7. VERIFICATIONS
A. IN CASE OF CONFLICT BETWEEN PLANS AND SPECIFICATIONS,
CONSULT THE DESIGNING ENGINEER.
B. IN CASE OF CONFLICT ON DRAWINGS, STRUCTURAL AND
ARCHITECTURAL DESIGN, CONSULT THE DESIGNING ENGINEER.
C. FOR ANY CONFLICTS BETWEEN THE ACTUAL AND THE WORKING
PLANS, CONSULT THE SUPERVISING ENGINEER.
8. STEEL WORKS
A. ALL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE
WITH THE LATEST AISC SPECIFICATIONS FOR STRUCTURAL WORK.
B. WELDS TO BE 6MM CONTINUOUS FILLET LAID DOWN WITH APPROVED
COVERED ELECTRODE.

9. ROOFING WORKS
MAIN ROOF
A. USE GALVANIZED IRON (G.I.) ROOFING MATERIAL 0.4mm THICKNESS.

Prepared by: Conformed by:

MICHAEL JAN M. DE CELIS KERWIN WILLIAM TAN


Civil Engineer Owner / Applicant
Lic. No: 0114556 PTR No. 8411270
Date on: 01-03-19 Issued at: GSC