ENGINEERING YOUR SAFETY

WWW.HIGHWAYCARE.COM

Anti-Gawk Screen Foundation Pavement & Anchor Details


Australia & New Zealand Approval Pavement Category
Type 3 Type 4 Type 5
Type 6
Type 1 Type 2 Asphaltic concrete Flush seal over Unsealed
Natural
Concrete Deep lift asphaltic concrete over granular granular compacted
surface
pavement pavement formation

Anchor spacing at
Anchor spacing at 36m; 24m;
• 1” Kelkin Leftie 20.13” (511mm) with • M24 460mm
Standard with • M24 250mm threaded bar with resin
Keligrout. AUS ONLY. threaded bar with Not
Highway Care • M24 460mm threaded bar with resin Not
Anchor spacing at 24m; resin. AUS ONLY. Not permitted - permitted
Screen • 1” Kelkin Leftie 18.25” (464mm) with Keligrout permitted -
• M24 460mm threaded bar with resin. AUS Anchor spacing at 36m see note. - see
Up to 36m • 1” Kelkin Leftie 14.25” (362mm) with Keligrout see note.
ONLY. & bow tie anchor; note.
• M24 Mechanical Anchor. AUS ONLY.
System Type

anchoring • 1” Kelkin Leftie 18.25” (464mm) with • M24 460mm


Keligrout threaded bar with
resin. AUS ONLY.

• M24 250mm threaded bar with resin


Not
LDS with Highway • M24 460mm threaded bar with resin • M24 460mm threaded bar with resin • M24 460mm Not
Not permitted - permitted
Care Screen • 1” Kelkin Leftie 18.25” (464mm) with Keligrout • 1” Kelkin Leftie 18.25” (464mm) with threaded bar with permitted -
see note. - see
12 metre anchoring • 1” Kelkin Leftie 14.25” (362mm) with Keligrout Keligrout resin see note.
note.
• M24 Mechanical Anchor

• M24 250mm threaded bar with resin


Not
MDS with Highway • M24 460mm threaded bar with resin • M24 460mm threaded bar with resin • M24 460mm Not
Not permitted - permitted
Care Screen • 1” Kelkin Leftie 18.25” (464mm) with Keligrout • 1” Kelkin Leftie 18.25” (464mm) with threaded bar with permitted -
see note. - see
6 metre anchoring • 1” Kelkin Leftie 14.25” (362mm) with Keligrout Keligrout resin see note.
note.
• M24 Mechanical Anchor
Notes: Alternative anchor options may be used that replicate the strength/characteristics of tested anchors. Alternative anchor options will require a local site specific risk assessment. There may be the need for a geotechnical report as to ground
suitability for the type of pinning required. If conflict arises with details listed within this manual, then the conditions in state approval documents take precedence. Refer to drawing BG-70-38 for wind loading requirements.

Rev. D – 03/19 ©2019 Highway Care Limited. All Rights Reserved. Page 48 of 56