Professional Documents
Culture Documents
Series B3: 56M175 Roots Meter: Units Imperial Units Metric
Series B3: 56M175 Roots Meter: Units Imperial Units Metric
Series B3: 56M175 Roots Meter: Units Imperial Units Metric
NOTES:
1
Bolt Length varies by application.
2
Weights and dimensions available for CPS upon request.
Accuracy Curve
RATE - % of Meter Rating
0 10 20 30 40 50 60 70 80 90 100
102
101
ACCURACY - %
100
99 Model 56M175 Above data has been determined from tests performed
Body Type Series B with air at atmospheric pressure and ambient tempera-
98 ture, using positive displacement bell or piston provers
Start Rate 40 cfh
dimensionally traceable to the United States National
97
Stop Rate 29 cfh Institute of Standards and Technology (NIST) and
Rangeability ±1% 53:1 traceable to NMi - Netherlands Measurements Institute
Rangeability ±2% 109:1 for volumetric flow rate.
Differential Curve
2.0
DIFFERENTIAL - IN. W.C.
1.5
1.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100
Centerline to
56M175 Overall Length Overall Height Width (Flange/Flange) Accessory End (CL-AU) Request Detailed
Series B3 inches mm inches mm inches mm inches mm Drawing Number
CTR 38-1/32 966 18 457 21 533 16-15/32 418 D054750-001
CD 42-1/2 1080 18 457 21 533 25-17/32 649 D054433-001
CPS 40 1016 18 457 21 533 16-15/32 418 D054751-001
To order
Specify: Meter Series, Size and Type
(i.e., ROOTS Meter Series B3 56M175 CD).
For CD, specify Inlet (Top or Side) and ID Rotation
Accessory Unit (CW-B or CCW-A).
Height
For Pulser, specify Single or Dual Connectors and
Connector Type (MS Circular, Conduit or Cable Gland).
For more specific ordering information on the
electronic products, request: TS:SSP or TS: MC.
CL-AU Contact the factory for other available information,
Length options, or special requests.