Professional Documents
Culture Documents
KLH - Brochure - Building - Physics - Pag 21
KLH - Brochure - Building - Physics - Pag 21
b u ilt fo r l i v in g
BUILDING PHYSICS
IMPRINT
01 A ir T igh t nes s 03
02 He at Insul ation 06
03 Dur a bilit y 12
04 Pr ot ect ion ag a inst Moist ure 14
05 Sound Insul ation 18
0 6 Fire Pr ot ection 23
07 Biblio gr aph y 25
01
I N T RO D U C T I O N
BUILDING
physics
Measures to counteract or slow down global warming The energy performance certificate indicates to what
are constantly being searched for. In this respect it is extent a building fulfils or does not fulfil the climate
essential to create Energy Performance Certificates to protection requirements. By means of thermal imaging
assess buildings energetically and to contribute to climate cameras it is furthermore possible to make thermogra-
protection on a legal basis. phic building surveys, as well as to visualise energy losses
and make them measurable.
In Austria, the issue, use, principles and basics of energy
performance certificates are defined by various provin- Through the application of KLH solid wood panels it is
cial laws and the Energy Performance Certificate Pre- possible to make use of essential advantages, such as the
sentation Act (EAVG). These legal norms are intended to air tightness of the structure, avoidance of thermal bridges
transpose the Energy Performance of Buildings Directive by means of homogeneous layers, high energy storage
(EPBD), Directive 2002/91/EC, on the total energy mass for warmth protection in summer and higher appli-
efficiency in buildings into national law. Standard cation tolerance through existing moisture storage mass.
ÖNORM H 5055 regulates the energy performance The increased use of KLH solid wood panels in passive
certificate for buildings. house technology shows that solid timber construction
generally constitutes a sensible approach towards sustai-
In principle this means keeping the required heating nability and reduced CO2 emissions.
warmth in the building in winter and preventing heat from
penetrating the building envelope in summer, particularly
as the use of air-conditioning systems mostly involves
high energy expenditure.
02
AIR TIGHTNESS
01 AIR TIGHTNESS
1.1 GENERAL INFORMATION
In practice, very often no difference is made between tightness. Nevertheless, a good n50 value alone is still no
these two terms, although there are clear distinctions to guarantee for fault-free constructional design. Only an
be made. Wind tightness of a construction component exact investigation of the building by an expert (e.g. by
prevents air flows from entering insulation layers and means of a Blower Door Test) will show whether work
thus the loss of heat into the open. The wind-proofness of was carried out down to the last details, and whether any
buildings can be compared to the outside material of later constructional damage can be excluded or not.
winter jackets: if the windproof layer is missing, heat will
escape and cause a person to feel cold. As wind insulations “A building is not supposed to be completely airtight. It
are always located at the outside of the insulation layers, must still be able to breathe.” This is a statement often
the vapour diffusion resistance of the wind insulation heard in discussions on the topic of building tightness.
should be as low as possible, and it should be taken into
account in physical construction considerations. We should add the following explanatory quote: “The
ventilation of inhabited rooms through building joints can
The air tightness of a construction component or an never be sufficient. Even very permeable buildings with
entire building is a measurable unit (air change rate). a considerable draft during moderate winds have insuffi-
cient air exchange during windless, mild weather periods.
It indicates the amount of air per hour [m³/h] flowing Therefore, the air flow through joints has a number of
between the inside and outside of a construction compo- disadvantages: for example, a high percentage of all
nent and/or building at a certain defined pressure diffe- construction damage is caused by overly permeable
rence. The resulting n50 value, calculated from positive building envelopes. Other disadvantages of joints are the
and negative pressure volume flows at 50 Pascal, classi- lack of noise protection and excessive heat loss.” [7.3]
fies a construction component with respect to its overall
03
AIR TIGHTNESS
Measurements with KLH solid wood panels have shown a vapour retarder adjusted to the further wall structure,
that 3-layer KLH solid wood panels with one-sided also serving as a convection barrier, compare fig. 1; the
industrial visual quality or domestic visual quality are entire building is wrapped and sealed with a membrane,
sufficiently airtight and can therefore be used as an usually a textile fabric) or the KLH construction as such
airtight layer. Panels with 5 or more layers also fulfil this is used as the building’s tightness layer. In this case the
criterion in non-visual quality. construction component’s edges as well as all joints
between the construction components or to adjacent
In principle, there are two options for the airtight design construction components are sealed with e.g. pre-com-
of a KLH construction: either the tightness of the con- pressed sealing tapes (compare fig. 2).
struction is provided by installing a flow-tight layer (e.g.
Joint
glue-bonding
Screw connections
according to statics
F i g . 1 – F l o w - t i g h t c o n n e c t i o n t h r o u g h w r a p p i n g a n d s e a l i n g b y F i g . 2 – F l o w - t i g h t c o n n e c t i o n o f K L H s o l i d w o o d p a n e l s b y w a y o f
way of a convection barrier sealing tapes
04
AIR TIGHTNESS
The tightness of the KLH construction much less depends construction (possibly with the use of 3-layer KLH solid
on the panel, but more on the connection joints to other wood panels in non-visual quality). If leaks are found
construction components and panel joints. during such measurements, it is normally possible to
eliminate them without any extensive efforts. Basically,
Construction component connections, joint connections, the Blower Door Test is only required for certified passive
penetrations, etc. must be sealed according to the houses. All low-energy houses with KLH elements can be
acknowledged rules of technology. We recommend built confidently without any testing, if the joint connec-
testing the tightness of the construction by Blower Door tions are made correctly.
measurement – if possible even before completion of the
Negative pressure
50 Pa
Building pressure difference
Airtight membrane
Air flow
Measured values:
Building pressure Airtight
membrane
difference
Negative pressure Air flow
50 Pa
Ventilator Metering
orifice
Ventilator
Metering orifice
F i g . 3 – S c h e m a t i c d e p i c t i o n o f a B l o w e r D o o r M e a s u r e m e n t [ 7. 3 ]
With conclusive planning and the correct installation of regard is the arrangement of the sealing tape in the centre
the air tightness layer with joint tapes, even three-dimen- of the panel. This will achieve maximum tightness in both
sional connection points can be tackled (compare fig. 2, directions.
shiplap edge in ceiling area). What is important in this
05
H EA T I N S U L A T I O N
• Heat conductivity
• Convection tightness
The use of KLH solid wood panels for wall and ceiling It has to be pointed out that the thermal behaviour of the
structures is of an advantage, because it can be installed KLH solid wood panel can only be realistically assessed
in mostly homogenous layers, as opposed to other light- with unsteady humidity and heat flow calculations. For
weight construction types. This leads to even tempera- example, unsteady mathematical models form the basis
ture fields across the entire surface and is also advanta- of the programmes “Delfin” or “Wufi”.
geous for the hygro-thermal behaviour of the construction
(safety potential due to the available moisture storage The high gross density of wood causes a long phase shift
mass of the existing solid wood wall, higher application (= time between the occurrence of the highest tempera-
tolerance) – the construction becomes more resilient. ture on the outside surface of a construction component
until the time the highest temperature is reached on its
Heat conductivity essentially depends on the gross inside surface). This is particularly important for heat
density and moisture content of the KLH solid wood insulation in summer, since long phase shifts mean that
panel. For “timber” with a gross density of 500 kg/m³, buildings remain cool inside, even with high outside
ÖNORM 12524 [7.5] only provides a rated heat conducti- temperatures. During low outside temperatures, this
vity of 0.13 W/ (m*K). For spruce wood, ÖNORM B 3012 principle has the exact inverse effect.
[7.6] provides a λ-value of 0.11 W/(m*K) at relative wood
moisture of 12%. The U-value used to calculate the heating energy demand
only gives information about how much heat is perma-
Laboratory tests by the French institute CSTB (Centre nently lost. It does not tell how long it takes until this loss
Scientifique et Technique du Bâtiment) with 3 and 5-layer actually takes place. The heating energy demand of build-
KLH samples resulted in a λ-value of 0.10 W/(m*K). ings made of KLH solid wood panels is low. On the one
hand, this is due to the high gross density of the elements
In case of a solid KLH exterior wall humidity of less than and the high specific heat capacity. On the other hand, it
12% can be expected during the relevant winter months. is due to the low temperature penetration coefficient and
Due to this reason, a λ-value of 0.11 W/ (m*K) is applied the low heat conductivity.
for KLH construction components in the examples below.
06
H EA T I N S U L A T I O N
The aim inside buildings during winter is to create tempe- The determining factor is heat conductivity, better known
ratures that ensure a high level of comfort. as the U-value.
Fig. 4 – Heat transfer coefficient depending on panel thickness (with λ K L H = 0.11 W/(m*K))
07
H EA T I N S U L A T I O N
In combination with a 140 mm thick insulation of thermal conductivity group 035 (TCG 035), the U-value of a 94 mm thick
KLH wall element is calculated as follows:
1
Heat transfer coefficient U= di
Rsi + ∑ + Rse
λi
1 = 0.199 W/(m2 • K)
Heat transfer coefficient U= 0.094 0.14
0.13 + + + 0.04
0.11 0.035
The figure below shows a diagram where the U-values of insulated KLH wall elements with a thickness of 94 mm are
listed in reference to the thickness of the insulation material (TCG 035).
Fig. 5 – U -value of wall structures (KLH 3s 94 DQ) with variable insulation material thicknesses
08
H EA T I N S U L A T I O N
EW 01 EW 02 EW 03 EW 04 Key to fig. 6
1 1 1 1
2 Insulation TCG 040 (λ = 0.040 W/(m • K))
2 2 3 3
3 Insulation TCG 035 (λ = 0.035 W/(m • K))
4 -30cm
9.4cm
4 -30cm
9.4cm
4 -30cm
9.4cm
F i g . 6 – I n s u l a t e d K L H e x t e r i o r w a l l ( K L H 3 s 9 4 D Q ) i n f o u r d i f f e r e n t
Assumed heat transmission
variants coefficients: Rsi = 0.13 m2 • K/W
Rse = 0.04 m2 • K/W
HE AT TR A NSFER COEFFICIENT
EW 01 EW 02 EW 03 EW 04
Percentage of wood 0% Percentage of wood 10% Percentage of wood 0% Percentage of wood 10%
Ta b l e 2: N u m e r i c a l a n a l y s i s o f e x a m p l e s i n r e f e r e n c e t o f i g . 6
09
H EA T I N S U L A T I O N
U-value of entire component in [W/(m 2*K)]
Modern architecture often includes a large number of Heat insulation in summer requires sound planning and
glazed surfaces. While these surfaces allow solar heat an integrated approach to the following 3 aspects:
gains in winter, they create a more critical starting level
in summer. When considering heat insulation in summer, • loads
it should normally be made sure that the maximum • ventilation
medium felt temperature inside rooms should not be • type of construction
exceeded, even without the use of air-conditioning.
Buildings that need air-conditioning because of their The term “loads” in inhabited rooms means the permea-
specific usages should keep the cooling load at the lowest tion of solar energy through windows. The most effective
possible levels. Excess heating during summer is consi- and cost-saving protection against overheating is sun
dered avoided if the felt temperature in any given room protection applied outside of the building.
during the hot period does not exceed the defined tempe- The proportion of heat transmission through opaque
rature limits. [7.7] construction components, however, can be neglected in
comparison.
Any planning effort should aim at creating an interior
climate with as little a difference to the outside climate
as possible, using natural ventilation through windows.
Cooling provided by technical facilities with high energy
consumption is not in line with sustainable planning for
residential buildings.
10
H EA T I N S U L A T I O N
Figure 8 shows the effectiveness of window ventilation contribution here, because the air flow might well provide
depending on the position of the casements. A heat hygienic air change, but is not sufficient for transporting
recovery ventilation system cannot make any significant the excess amount of heat energy out of the building.
Ventilation possibilities
Open
10cm
6cm
3cm
1.23 x 0.94 m (H x W)
Fig. 8 – Relation of window casement position to the air change rate [7.8] Temperature difference in K
The increasing heat insulation thicknesses in residential In order to activate the masses in the building, the following
building as a consequence of better heat protection in conditions must be fulfilled:
winter have led to the situation that the phase shift of the
outer construction part is large enough – independent of • Heat-storing construction material needs to be in
whether “heavy” or “light” components are used. Simply direct contact with the ambient air (no facing formwork)
put: what is good in winter is also useful in summer. • Good heat insulation on the outside (is usually
fulfilled)
Solar heat energy that penetrates a building despite solar • No covering of installations, carpets, cabinets (would
protection should be absorbed by surfaces enclosing a have the same effect as facing formwork)
room to the greatest possible extent, without creating an • The construction component participating in storing
unpleasant climate inside the room. The KLH solid wood heat must be sufficiently thick
wall can be used for heat storage, similar to a brick wall.
Planners should ensure that heat saved inside during
daytime will be discharged at night – a principle that
resembles a discharging battery.
11
D U RA B I L I T Y
KLH solid wood constructions therefore provide an 10% that reaches the room is saved in the KLH solid wood
optimal balance between heat saving during daytime and panels during the daytime. Due to natural ventilation
energy discharge at night. The most effective measure at night, the energy storing KLH solid wood panel will
against overheating in summer is transparent solar automatically discharge energy during cooler night times.
protection, which retains up to 90% of the solar energy and The risk of any insidious overheating in summer can be
still allows enough light into the rooms. The remaining minimised this way.
03 DURABILIT Y
3.1 Intended purpose of the KLH solid wood panel
KLH solid wood panels are intended as load-bearing or Construction components directly exposed to weathering
non-load-bearing construction elements in timber frame must be faced with effective weather protection.
constructions. They may be exposed to static, quasi-static
and short-time dynamic loads (such as earthquake loads).
They are intended to be used in the usage classes 1 and 2
according to EN 1995-1-1. [7.9]
The requirements are based on the assumption of a merely given to facilitate the selection of the right product
planned service life of KLH solid wood panels of 50 years. in the context of the expected, economically appropriate
Information on the service life cannot be construed as service life of a building. [7.10]
any form of guarantee granted by the manufacturer. It is
12
D U RA B I L I T Y
Depending on the installation setting, wood may be may cause long-term damage to wood constructions and
exposed to wood-corroding organisms to various should therefore be avoided. Constructional measures
degrees. By using the hazard classifications in the such as the installation of resistant larch sleepers or a
standards, the type and scope of any required chemical technically correct base design lift the plywood panel out
wood protection measure can be evaluated. Installed of the critical area. [7.7]
wood with a hazard classification of 0 does not need any
chemical wood protection. Only natural, unprocessed and untreated wood is used for
the production of KLH solid wood panels. The individual
Prior to using any chemical wood protection measures layers are technically dried prior to gluing. On dispatch,
it must be verified as to what extent the wood can be KLH solid wood panels have wood moisture of 12% ±
protected by way of precautionary constructional 2%. Installations according to the approved usage classes
measures, for example, by keeping it permanently dry 1 and 2 do not usually require any chemical wood
(maximum humidity of 70%, maximum wood moisture protection. Any treatment of the wood should be per-
of up to 20%). formed after cutting the panels to size. Due to the large
number of wood protection products and their various
Special attention has to be paid to contact areas of KLH mechanisms, the relevant wood protection product has
solid wood elements with cold surfaces, such as foun- to be selected only after verifying that it is suitable for the
dations and basement ceilings. Critical climatic areas in planned application, whether treatment on site or in the
the bearing area and possible formations of condensate factory is reasonable and feasible.
Termites may also attack dry timber. They live on environmental considerations, the constructional solution
everything that contains cellulose, including leaves and should be given priority, for example by placing KLH
timber, or even paper. solid wood walls on reinforced concrete bases that avoid
direct contact with the ground. A distance of only a few
There are two types of termites – earth termites and centimetres will already provide sufficient and effective
drywood termites. While the first type needs contact with protection.
the soil in order to form colonies and to maintain them,
drywood termites, however, use wood as a place to live If chemical preservation is wanted and/or required,
and as part of their food chain. it may be applied on all sides and narrow surfaces after
cutting the panels to size.
In general, wood can be preventively protected by way
of constructional measures or chemical protection. For
13
P RO T E C T I O N A G A I N S T M O I S T U RE
Wood as a construction material is not only able to trans- Another characteristic of wood is that it swells and
port moisture by way of diffusion, but also by way of sorp- shrinks in relation to moisture. Wood is an anisotropic
tion and capillary lines. In this respect, wood is incredibly material with hygroscopic properties. Therefore, swelling
effective, even if these research results of the last 20 years and shrinking will vary, depending on the direction of the
are not always noted by the wider public. fibres.
We distinguish between 3 mechanisms that are responsible For sawn timber we distinguish the 3 main cutting
for the transport of moisture in wood directions as follows
• Vapour diffusion (vapour/pressure difference) • Longitudinal (~0.01% change of shape per % change
• Sorbate line (relative humidity) of moisture)
• Capillary line (surface tension) • Radial (~0.16% change of shape per % change of
moisture)
These are unsteady processes. Nevertheless, condensa- • Tangential (~0.33% change of shape per % change of
tion water calculations on the basis of the Glaser method moisture)
are still made, although this procedure only takes into
account the diffusion in mineral construction materials, Due to the crosswise arrangement of the layers and the
and is therefore far too narrow for wood. [7.11] high-quality gluing during the production of the KLH
solid wood panels, these values are significantly reduced.
The KLH solid wood panel has a similar effect as a On the plane of the panel, only a minor longitudinal
moisture-variable vapour retarder. In winter with low shrinkage can be observed. As regards the thickness of
humidity, the ability for wood to transport moisture is the panel, a mean value between radial and tangential will
reduced. It increases as soon as the inside air humidity apply.
has adjusted to the summer climate. Wood as a natural
construction material always behaves in tune with nature • On the panel plane ~0.01% change of shape per %
– through its entire service life. If the tried-and-tested change of moisture
“more airtight inside than outside” construction principle • At a right angle to the panel direction ~0.20% change
is taken into account, the exterior wall is made safer in of shape per % change of moisture (see “Technical
terms of building physics if a KLH solid wood panel is Key Figures“)
used.
14
P RO T E C T I O N A G A I N S T M O I S T U RE
In principle, floors and floorings of stone and ceramics are balance out movements between the KLH panel and the
not watertight. The joint is the weak element. Although used surface.
the KLH solid wood panel maintains its stable shape
due to its crosswise gluing, it would be disastrous to lay Fig. 10 shows moisture-induced length changes of dif-
tiles or comparable floorings directly onto the surface ferent, commonly used construction panels. It is quite
of the wooden panel. In order to avoid any excessive clearly visible how different the swelling and shrinking
tension and bending stresses due to a change in shape, the behaviour of plasterboards is compared to panels with a
KLH solid wood panel should be installed together with wood content.
plasterboards. These low swell and low shrink boards
0 1 2 3 4
ε • 103
F i g . 10 – D i f f e r e n t s w e l l i n g a n d s h r i n k i n g b e h a v i o u r o f c o m m o n p a n e l m a t e r i a l s i n r e l a t i o n t o e a c h o t h e r [ 7.12 ]
In corner areas of walls and floors material movements are The floor area usually features two-layer gypsum fibre
unavoidable (impact sound insulation). This problem can boards. Using construction products that have been
only be solved by means of elastic, permanently flexible approved for the floor area as a reference is recommended.
connections. Elastic sealing joints are also necessary In wooden constructions it is also recommended that one
for impact sound insulation towards side walls. At additional, simple sealing layer below the floor structure
inaccessible points (shower trays, bathtubs) or in areas be applied, directly on the KLH ceiling panel. The sealing
with strong splash water exposure (shower), the sealing layer should be designed with flooring all around raised
should be made according to the following figure 11 to the walls, and have a drainage option available in the
(sealing at walls and floors). In the rest of the bathroom, installation duct. In case of a pipe burst potential water
construction according to figure 12 should be sufficient damage can be detected early on, and any further damage
(sealing only on floors raised to the surrounding walls). to the building can be prevented.
At the rising wall planking with gypsum plasterboards is
sufficient (damp room panels, compare fig. 11 and 12).
15
P RO T E C T I O N A G A I N S T M O I S T U RE
F i g . 11 – C o r n e r f o r m a t i o n a n d s e a l i n g i n t h e s p l a s h w a t e r a r e a .
T h e s e a l i n g “ F ” m u s t b e c o n t i n u e d b e h i n d t h e t i l e s . [ 7.12 ]
TL… … tile
JM… … joint mortar
AD… … adhesive, hydraulically hardened thin-bed mortar
C……… closing off of the entire area, modified plastic
dispersion
PR… … priming, if required by the adhesive manufacturer
PB… … plasterboard, drywall or gypsum fibre board –
observe rating
IL……… insulation layer
F i g . 13 – F l o o r s t r u c t u r e a n d s e a l i n g i n t h e a r e a [ 7.12 ]
16
P RO T E C T I O N A G A I N S T M O I S T U RE
Below are some examples to illustrate the splash water area according to the “Information sheet for bathrooms and wet
rooms in timber construction and drywall construction” by Info-Dienst Holz. On areas marked in grey, sealing according
to fig. 11 to 13 has to be used.
F i g . 14 -1 F i g . 14 - 2
Guest toilet Bathroom with bathtub as shower
F i g . 14 - 3 F i g . 14 - 4
Bathroom with tub without shower function Bathroom with tub without shower function
and shower and floor drain in shower area used as
planned
17
S O UND IN S UL AT I O N
Mould and its spores are a natural part of our environ- not only the inside surface temperature is important, but
ment and are also present in the interior. They grow on also the predominant level of relative humidity. Scientists
a large number of materials and across a wide range of have set a surface temperature limit of 12.5°C for mould
temperatures. Moisture – especially on material surfaces development. Under normal conditions of 20°C and 50%
– plays an essential role. relative humidity in interior rooms, the 12.5° isothermal
lines have a humidity of 85%. These 85% of relative
Such moisture is most often the result of constructional humidity are usually not sufficient for the development of
defects (e.g. thermal bridges or open joints in compo- moulds – independent of the construction material.
nents) and damage events (water pipe burst, insufficient
connection joints in bathrooms) as well as insufficient Due to its hygroscopic properties and its content materials,
ventilation and/or hygiene. wood has a higher moisture tolerance than mineral
construction materials. Sandwich-type wall structures
Mould does not destroy the building fabric – it needs it and the possibility of moisture storage provided by KLH
as carrier material for its own growth, but also uses its solid wood panels create a significant safety potential
substances as a possible food source. As mentioned, it and therefore the increased hygro-thermal application
can grow across a wide temperature range. Therefore, tolerance of structures with KLH solid wood panels.
In the process of harmonising standards within the EU, and to make an exact determination of their sound insu-
measurement and calculation procedures for sound lation properties in a laboratory. This results in test certifi-
parameters of construction components and buildings cates that only exhibit whole figures, free from influences
have been standardised. by secondary sound paths (flanking transmission).
18
S O UND IN S UL AT I O N
Ff
F i g . 16 – A i r b o r n e s o u n d a n d i m p a c t s o u n d t r a n s m i s s i o n p a t h s
b e t w e e n a d j a c e n t r o o m s [ 7.13 ]
19
S O UND IN S UL AT I O N
In a third step the energies of both individual com- Previously – especially in the German-speaking area –
ponents are added. The result is the expected sound sound insulation properties of construction components
insulation in the building. Impact sound at the con- were often determined on the basis of sample buildings.
struction site L’n results from the energetic addition of The planned wall and ceiling structures were set up on a
„Dd“ and „Df “ for example (compare fig. 16). test rig together with the usual technical secondary sound
paths, before sound measurements were performed. This
( (L /10)
L‘n = 10 log 10 n
(L /10)
+ 10 n,Df )
[dB] resulted in “mixed results” of direct sound transmission
L’n impact sound pressure level including secondary (construction component) and the secondary paths
paths present at the test rig. The resulting figures were usable
Ln impact sound pressure level of the component for planners insofar as the actual building situation was
measured in a laboratory comparable with the laboratory set-up. The separated
Ln,Df impact sound pressure level across the flank analysis of component and flank can therefore be regarded
as an additional tool for planners, in order to reach the
required sound insulation values with light-weight com-
ponents as well.
5.2 SOUND INSUL ATION IN REL ATION TO KLH SOLID WOOD PANELS
Ambient noise and increasing stress in the working world effective construction components is the combination of
make quiet and relaxing homes more important than ever KLH solid wood panels and elements of dry construction
before. The highest sound insulation demands apply to or light-weight construction.
components separating individual homes.
Despite the lack of mass, the same or even better values
In order to meet these high requirements, a second layer are achieved through inner material damping and soft-
is usually introduced according to the state of technology. ness of components (for example, by way of facing form-
Even classic solid construction must resort to this work) than in solid mineral construction.
solution in order to reach the required values, because any
increase of masses would no longer yield the desired For more than a decade, KLH Massivholz GmbH has been
effect. A double partition with KLH solid wood panels carrying out research and development together with
is therefore equally efficient as two-layer solutions from institutes that are acknowledged throughout Europe in
classic solid construction. The structures have order to continuously improve sound insulation of KLH
comparable component thicknesses, but solid wood constructions. For many years the company has had its
constructions are five times lighter (weight reduction by own wall and ceiling test rigs and the required equipment
a factor of 5). to offer clients the appropriate solutions individually and
quickly.
The basic prerequisite is the careful planning of details,
knowing the principles of sound insulation and correct
technical implementation of the sound insulation concept
at the construction site. Another option for designing
20
S O UND IN S UL AT I O N
Sound insulation from one room to another plays a very If, however, planning mistakes are made in the field of
important role. Planning mistakes regarding room acous- building acoustics (transmission of airborne and impact
tics may be inconvenient, but such problems can usually sound), improvement measures very often entail conside-
be remedied at relatively low costs. rable costs.
F i g . 19 – D o m e l o u d s p e a k e r a s i t i s u s e d i n d e t e r m i n i n g a i r b o r n e
s o u n d i n s u l a t i o n [ 7.14]
21
S O UND IN S UL AT I O N
Both airborne sound transmission and impact sound levels in the entrance room are decisively influenced by
Modern calculation programmes and a large number of efficient the main separating component is, the stronger
construction component measurements facilitate the the influence of secondary sound paths will be. Depen-
determination of building acoustic properties of individual ding on the type of stimulus, the sound energy will follow
components. In order to comply with sound protection different paths. Similar to electric current, sound also
requirements for a particular construction it is, however, always follows the path of least resistance. In this context
not sufficient to only determine the properties of the it is important to consider improvements to the separating
separating components. The influence of secondary component as early as during the planning stage, but it is
sound paths also has to be taken into account. The more equally important to take flank paths into account as well.
• Constructional separation of components (e.g. conti- The third measure is also the most effective one. It not
nuous ceilings have to be avoided) only improves sound insulation, but also increases fire
• Partial decoupling by way of soft, resilient sandwich protection and provides a neutral surface.
layers
• Protection barriers (facing formwork makes it harder
for sound energy to enter or exit)
22
F I RE P RO T E C T I O N
06 FIRE PROTECTION
6.1 FL AMMABILIT Y OF KLH SOLID WOOD PANELS
23
F I RE P RO T E C T I O N
If the surface of KLH solid wood panels is protected It has to be pointed out that load-bearing interior walls
against fire by planking with, for example, plasterboard will most often be exposed to combustion on both sides.
fire protection slabs in the beginning, the failure times Special attention should also be paid to pillars between
of the planking may be considered in determining the windows and doors in exterior walls.
overall rating. By using the multi-layered KLH solid wood
panels, components can be designed with higher fire Proof of integrity – criterion “E”
resistance, and proof can be provided for R90 or R120,
for example. The criterion of integrity is regarded fulfilled if two com-
pletely intact panel layers as well as a 5 mm thick residual
5-layer KLH solid wood panels mostly reach R60 without lamella on the side exposed to the fire are left after a fire.
additional measures or even R90 if the thickness of the This means that a 3-layer residual panel with two fully
panel is sufficient. This way, even visible constructions intact glue joints has to survive the fire.
can be realised with high levels of fire resistance. Another
increase can be achieved by either increasing the thick- Proof of heat insulation – criterion “I”
ness of the panels and/or the number of layers and/or by
way of appropriate planking. The criterion of heat insulation is of minor importance for
constructions made of KLH solid wood panels, because
In order to increase economic efficiency or to maintain it is already regarded fulfilled with a residual panel thick-
the slim design of components, wall components are ness of a few centimetres.
often realised with 3-layer KLH solid wood panels (max.
R30) plus additional planking.
24
B I B L I O G RA P H Y
07 BIBLIOGRAPHY
25
NOTES
NOTES
NOTES
K L H M a ssivh o l z G mb H
A - 8 842 Kat sch a. d. Mur 202 | Tel +43 (0)358 8 8 835 0 | Fa x +43 (0)358 8 8 835 20
of f ice@klh.at | w w w.klh.at
www.pefc.at