Professional Documents
Culture Documents
2.0 Primary Load Cases: Structural Calculation Report For 6.0M and 8.2M Dia Roof Structure
2.0 Primary Load Cases: Structural Calculation Report For 6.0M and 8.2M Dia Roof Structure
STRUCTURAL CALCULATION 1
REPORT FOR 6.0M AND 8.2M DIA REV : 0
ROOF STRUCTURE DATE : 14‐02‐2019
PAGE : 5 OF 44__________________
2.0 PRIMARY LOAD CASES
The Primary Load Case includes various loads which listed below which applicable for the structure.
These loads are applied in Staad Pro Software.
21
2.1 DEAD LOAD
DEAD LOAD
In Dead Load, There are permanent loads applied to Structure which load are always act as static
load. Below are the different types of Dead load.
____________________________________________________________________________________________________
DESIGN CALCULATION REPORT FOR 6.0M AND 8.2M DIA TANK ROOF STRUCTURE
DOC NO.
STRUCTURAL CALCULATION 1
REPORT FOR 6.0M AND 8.2M DIA REV : 0
ROOF STRUCTURE DATE : 14‐02‐2019
PAGE : 6 OF 44__________________
2.2 LIVE LOAD
LIVE LOAD : 1.2 KN/M2
2.3 WIND LOAD
____________________________________________________________________________________________________
DESIGN CALCULATION REPORT FOR 6.0M AND 8.2M DIA TANK ROOF STRUCTURE
DOC NO.
STRUCTURAL CALCULATION 1
REPORT FOR 6.0M AND 8.2M DIA REV : 0
ROOF STRUCTURE DATE : 14‐02‐2019
PAGE : 7 OF 44__________________
3.0 STAAD PRO CALCULATION FOR TANK STRUCTURE
3.1 STAAD ISOMATRIC MODEL FOR 6.0m Dia and 8.0 Tank
____________________________________________________________________________________________________
DESIGN CALCULATION REPORT FOR 6.0M AND 8.2M DIA TANK ROOF STRUCTURE
DOC NO.
STRUCTURAL CALCULATION 1
REPORT FOR 6.0M AND 8.2M DIA REV : 0
ROOF STRUCTURE DATE : 14‐02‐2019
PAGE : 8 OF 44__________________
ISMC 150
ISMC 75
____________________________________________________________________________________________________
DESIGN CALCULATION REPORT FOR 6.0M AND 8.2M DIA TANK ROOF STRUCTURE
DOC NO.
STRUCTURAL CALCULATION 1
REPORT FOR 6.0M AND 8.2M DIA REV : 0
ROOF STRUCTURE DATE : 14‐02‐2019
PAGE : 9 OF 44__________________
3.2 STAAD 3D MODEL
____________________________________________________________________________________________________
DESIGN CALCULATION REPORT FOR 6.0M AND 8.2M DIA TANK ROOF STRUCTURE