A. GENERAL
NOTES: MAIN REINFORCEMENT
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE CROSS TIE TABLE OF LAP SPLICE & ANCHORAGE LENGTH
SHOWN OR NOTED MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. 1. YIELD STRESS OF HOOPS = 40 KSI SLEEVES FOR UTILITY
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, 2. D = USE MAXIMUM COL. DIMENSION PIPES MAX. 1/5D BAR SIZES LAP SPLICES LENGTH ANCHORAGE
1/6 CLEAR HEIGHT OR 18" (450mm) MAX. PIPE DIA.=50mm (MM) TYPE "A" TYPE "B" LENGTH (MM)
t or 1_4d
MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED FOR ENGINEERS
6d
b
APPROVAL BEFORE FABRICATION. WHICHEVER IS GREATER. 0.40 0.30 0.60
H
M
t
IN
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN CHECK WITH 3. NUMBER OF HOOP TIES SAME AS PER
.
0.45 0.35 0.60
MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUIT PIPE SLEEVES, ETC., TO BE COLUMN TIES SCHEDULE.
D
0.61 0.40 0.60
D
EMBEDDED IN CONCRETE. 4. ALL CONCRETE REINFORCEMENT DETAIL
5
1_
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE, SHORING & BRACINGS SECTION SHOULD BE DONE IN ACCORDANCE W/ 0.76 0.56 0.60
OF THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. ACI DETAILING MANUAL 1980 PUB SP-66
1.10 0.90 0.68
B. CONCRETE & REINFORCEMENT 1.40 1.20 0.86
TYPICAL DETAIL FOR SLEEVES
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING CODE 1.90 1.40 1.12
AMERICAN CONCRETE INSTITUTE (ACI-318).
THRU CONCRETE BEAM
2.41 1.84 1.43
JOINT REINF.
2. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH AT THE END OF TWENTY JOINT HOOP SPACE @ "2Sh" WHEN THERE NOTES:
CONF.
REINF.
EIGHT (28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMPS AS FOLLOWS. ARE BEAMS HAVING WIDTH OF AT LEAST 1: TYPE "A" BUNDLED BARS
D
LOCATION 28 DAYS STRENGTH MAX. SIZE AGGREGATE MAX. SLUMP ONE HALF THE COLUMN WIDTH AND DEPTHS TYPE "B" INDIVIDUAL BARS
NOT LESS THAN THREE QUARTERS OF THE MAIN REINFORCEMENTS 2. NOT MORE THAN 33% OF THE BARS SHALL BE
CURBS 2500 PSI 3/4 IN. (19 MM) 4 IN. (100 MM) DEEPEST BEAM THAT FRAME INTO FOUR TO BE CONTINUOUS SPLICED WITHIN THE REQUIRED LAP LENGTH
COLUMNS 3000 PSI 3/4 IN. (10 MM) 4 IN. (100 MM) SIDES OF THE COLUMN. ALL OTHER
CONDITIONS USE HOOPS @ "Sh" CENTERS.
CONF.REINF.
BEAMS, GIRDERS 3000 PSI 3/4 IN. (19 MM) 4 IN. (100 MM)
SLAB ON GRADE 2500 PSI 3/4 IN. (19 MM) 4 IN. (100 MM) @ 300 o.c.
D
LOAD BEARING WALL 1000 PSI 3/4 IN. (19 MM) 4 IN. (100 MM)
40
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 40.
t
FOR COLUMN BAR SPLICES SEE TABLE
.
4. IN GENERAL THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING
REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS OTHERWISE SHOWN OF MINIMUM LAP SPLICE LENGTH OF
D
OR NOTED. COLUMN REINFORCEMENT
COLUMN TIES AS
PLAN
PER SCHEDULE
5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS.
SUSPENDED SLABS---------------------------------------- 3/4 IN .(19 MM) NOTE:
SLAB ON GRADE------------------------------------------ 1 1/2 IN. (38 MM)
WALLS ABOVE GRADE------------------------------------- 1 IN. (25 MM) ALL CONCRETE REINF. DETAIL SHOULD
BEAM STIRRUPS AND COLUMN TIES----------------------------1 1/2 IN (38 MM)
JOINT REINF.
BE DONE IN ACCORDANCE WITH ACI
WHERE CONCRETE IS TO EARTH BUT
REINF.
DETAILING MANUAL 1980 PUB-66.
CONF.
POURED AGAINST FORMS----------------------------------- 2 IN. (50 MM)
D
3 BAR DIA. 50 3 BAR DIA.
DIRECTLY AGAINST EARTH---------------------------------- 3 IN (75 MM)
6. SPLICES SHALL BESECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE W/
D3 D3 D3
TABLE 1 (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN ON
DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE.
D
7. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED & SECURED
IN PLACE PRIOP TO PLACING OF CONCRETE.
TYPICAL COLUMN ELEVATION SHOWING
8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, DOWELS AND TIES SPACING WHERE JOINTS IS AT POINT OF
EQUIPMENT'S AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL, STRESS, PROVIDE SHEAR RODS
AND MECHANICAL DRAWINGS. WITH ENGINEERS APPROVAL
MAIN REINFORCEMENTS TO BE
9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS IMMEDIATELY
CONTINUOUS (TOP & BOTT. BARS)
AFTER POURING BY THE USE OF WET BURLAP FOG SPRAYING, CURING COMPOUNDS OR OTHER BEAM
APPROVED METHODS.
TYPICAL SLAB & BEAM
10. STRIPPING OF FORMS AND SHORES:
FOUNDATION----------------------------------------------------------- 24 HRS. CONSTRUCTION JOINT DETAIL
SUSPENDED SLAB EXCEPT WHEN
ADDITIONAL LOADS ARE IMPOSED------------------------------ 8 DAYS LAP SPLICE LENGHT: AT ANY LEVEL NO
WALLS---------------------------------------------------------------------18 HRS. MORE THAN ALTERNATE BARS SHOULD
BEAMS---------------------------------------------------------------------14 DAYS BE SPLICED. MINIMUM DISTANCE BET.
H (CLEAR HEIGHT OF COLUMN)
1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 30 BAR DIA (MIN.) 30 BAR DIA (MIN.)
HALF OF THE "H"
WITHIN CENTER
80 PCF. FOR LOAD BEARING TYPE, TYPE CONCRETE BLOCKS, A MINIMUM COMPRESIVE STRENGTH OF TOP BARS @ SUPPORT (CONT.)
6.90 MPA SHALL BE DEVELOPED.
D=FOR BEAM
EXTRA TOP BARS @ SUPPORT
CONF.REINF.TIES
t=FOR SLAB
L
JT. REINF.
LAT. TIES
VERIFY DEPRESSION
3. LINTELBEAMS SHALL BEAR AT LEAT 8 INCHES (200 MM) ON EACH SIDE OF MASONRY WALL OPENINGS.
5. REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BAR DIAMETERS WHEE SPLICE 0.165L SPLICE
DOWELS FROM FOOTING OR SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF
30 BAR DIAMETERS, AND DOWELS TO MATCH. 0.22L