Unit 5 - Week 4: Assignment 4
Unit 5 - Week 4: Assignment 4
reviewer4@nptel.iitm.ac.in ▼
Courses » Chemical Process Control Announcements Course Ask a Question Progress FAQ
Unit 5 - Week 4
Register for
Certification exam Assignment 4
The due date for submitting this assignment has passed.
Course As per our records you have not submitted this Due on 2019-03-27, 23:59 IST.
outline
assignment.
How to access 1) Considering human body’s blood glucose regulation system as an example of feedback 1 point
the portal control, occurrence of diabetes is caused by faulty sensor.
Week 1 True
False
Week 2
No, the answer is incorrect.
Week 3 Score: 0
Accepted Answers:
Week 4
False
Lecture 21 :
Block diagram
2) For a ON/OFF controller, the controller action depends on 1 point
representation
sign of the error
Lecture 22 :
ON-OFF current value of the error
control
historical value of the error
Lecture 23 :
future value of the error
Proportional
control No, the answer is incorrect.
Lecture 24 : Score: 0
Proportional- Accepted Answers:
Integral control
sign of the error
Lecture 25 : 5
PID control 3) Consider a feedback control system with process transfer function of , disturbance transfer
10s+1
−0.5 1 1
function of , measurement dynamics and valve dynamics of . If this process is
Lecture 26 : 10s+1 0.1s+1 s+1
Limitations of controlled by a P controller with gain 0.45 to reject a unit step in the disturbance, the offset of the
PID controllers controller is equal to ___
Download
Videos
Weekly
Feedback Hint
Quiz :
© 2014 NPTEL - Privacy & Terms - Honor Code - FAQs -
Assignment 4 No, the answer is incorrect.
A project of Score: 0 In association with
Assignment 4
solutions Accepted Answers:
(Type: Numeric) 0.15
Week 5 Funded by
1 point
True
Week 7
False
Week 8
No, the answer is incorrect.
Score: 0
TEXT
TRANSCRIPTS Accepted Answers:
True
Interaction
Session 5) A PI controller allows for zero offset due to a ___ at origin.
Hint
1 point
offset increases
7) Consider a fired heater wherein a process stream is heated by combusting fuel in a 1 point
furnace. The outlet temperature of the process stream is controlled using the fuel flow by manipulating
0.36 −s
the fuel flow valve. For this system, GP = 5s+1
e . You can assume instantaneous and accurate
temperature measurement as well as instantaneous valve action with a gain of 83.3. A P controller with
gain of 0.01 is used to control the temperature. If the set point of the controller is suddenly increased by
2C, what is the instantaneous increase in the fuel flow?
0 scfm
0.020 scfm
0.600 scfm
1.667 scfm
8) 1 point
0.2 0.01
Consider a process with transfer function of and disturbance transfer function of . The
5s+1 2s+1
process is controlled with a P controller (gain of 0.5). If there is a step change in the disturbance, we
would see overshoot in the response.
True
False
9) Consider that a shell and tube heat exchanger is used to preheat a cold process stream by
condensing steam on the shell side. A PI controller is implemented to maintain process stream outlet
temperature by manipulating steam flow. In this case, the corresponding controller will be _______-
acting controller.
Hint
1 point
10)Consider that pressure inside a gas-phase CSTR is controlled by manipulating vent stream 1 point
flowrate. If a P controller is used to regulate this pressure, the corresponding controller gain will be
positive.
True
False