Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Aspen Exchanger Design and Rating Shell & Tube V9

File: Printed: 24-08-2019 at 10:29:26 PM

Overall Summary

1 Size 590.55 X 4880 mm Type BFM Hor Connected in 1 parallel 1 series


2 Surf/Unit (gross/eff/finned) 126.2 / 124 / m² Shells/unit 1
3 Surf/Shell (gross/eff/finned) 126.2 / 124 / m²
4 Design (Sizing) PERFORMANCE OF ONE UNIT
5 Shell Side Tube Side Heat Transfer Parameters
6 Process Data In Out In Out Total heat load kW 2023
7 Total flow kg/s 13.8889 22.5848 Eff. MTD/ 1 pass MTD °C 18.29 / 20.1
8 Vapor kg/s 0 0 0 0 Actual/Reqd area ratio - fouled/clean 0.68 / 1.52
9 Liquid kg/s 13.8889 13.8889 22.5848 22.5848
10 Noncondensable kg/s 0 0 Coef./Resist. W/(m²-K) m²-K/W %
11 Cond./Evap. kg/s 0 0 Overall fouled 610.6 0.00164
12 Temperature °C 75 30 20 40 Overall clean 1358.7 0.00074
13 Dew / Bubble point °C 108.45 108.44 85.55 85.55 Tube side film 5942.9 0.00017 10.27
14 Quality 0 0 0 0 Tube side fouling 2489.5 0.0004 24.53
15 Pressure (abs) bar 3 2.5 1.01325 0.51325 Tube wall 27678.2 4E-05 2.21
16 DeltaP allow/cal bar 0.5 0.5871 0.5 0.70051 Outside fouling 2000 0.0005 30.53
17 Velocity m/s 1.3 1.23 1.59 1.66 Outside film 1881.2 0.00053 32.46
18 Liquid Properties Shell Side Pressure Drop bar %
19 Density kg/m³ 739.33 783.47 1011.06 995.93 Inlet nozzle 0.00583 1.02
20 Viscosity mPa-s 0.4445 0.8731 1.0017 0.6514 InletspaceXflow 0.01587 2.77
21 Specific heat kJ/(kg-K) 3.537 3.316 4.205 4.228 Baffle Xflow 0.30509 53.27
22 Therm. cond. W/(m-K) 0.1387 0.1556 0.6034 0.6315 Baffle window 0.20648 36.05
23 Surface tension N/m OutletspaceXflow 0.01594 2.78
24 Molecular weight 46.07 46.07 18.02 18.02 Outlet nozzle 0.02351 4.11
25 Vapor Properties Intermediate nozzles
26 Density kg/m³ Tube Side Pressure Drop bar %
27 Viscosity mPa-s Inlet nozzle 0.03629 4.97
28 Specific heat kJ/(kg-K) Entering tubes 0.04063 5.56
29 Therm. cond. W/(m-K) Inside tubes 0.59008 80.8
30 Molecular weight Exiting tubes 0.05894 8.07
31 Two-Phase Properties Outlet nozzle 0.0044 0.6
32 Latent heat kJ/kg Intermediate nozzles
33 Heat Transfer Parameters Velocity / Rho*V2 m/s kg/(m-s²)
34 Reynolds No. vapor Shell nozzle inlet 1.01 751
35 Reynolds No. liquid 41223.03 21002.46 25126.4 39726.1 Shell bundle Xflow 1.3 1.23
36 Prandtl No. vapor Shell baffle window 0.63 0.6
37 Prandtl No. liquid 11.33 18.61 6.98 4.36 Shell nozzle outlet 2.16 3650
38 Heat Load kW kW Shell nozzle interm
39 Vapor only 0 0 m/s kg/(m-s²)
40 2-Phase vapor 0 0 Tube nozzle inlet 2.72 7479
41 Latent heat 0 0 Tubes 1.59 1.66
42 2-Phase liquid 0 0 Tube nozzle outlet 1.22 1474
43 Liquid only -2138.7 1907.3 Tube nozzle interm
44 Tubes Baffles Nozzles: (No./OD)
45 Type Plain Type Double segmental Shell Side Tube Side
46 ID/OD mm 15.65 / 19.05 Number 37 Inlet mm 1 / 168.28 1 / 114.3
47 Length act/eff mm 4880 / 4795 Cut(%d) 26.63 13.97 Outlet 1 / 114.3 1 / 168.28
48 Tube passes 6 Cut orientation V Intermediate / /
49 Tube No. 432 Spacing: c/c mm 120 Impingement protection None
50 Tube pattern 30 Spacing at inlet mm 245.48
51 Tube pitch mm 23.81 Spacing at outlet mm 245.48
52 Insert None
53 Vibration problem (HTFS / TEMA) No / RhoV2 violation No