RHEOCRETE®222+

Organic corrosion inhibiting admixture

Description Plastic properties


RHEOCRETE®222+ is a state-of-the-art corrosion The plastic properties of concrete are not
inhibiting admixture formulated to inhibit the significantly affected by the use of
corrosion of steel reinforcement in concrete. RHEOCRETE®222+.
RHEOCRETE®222+ provides two levels of corrosion
protection, making it the most effective corrosion Slump and temperature
inhibiting admixture available. RHEOCRETE®222+ has no effect on slump or the
temperature development profile of concrete.
Advantages
RHEOCRETE®222+ extends the service life of Concrete steel bond strength
reinforced concrete by slowing the ingress of Concrete to steel bond strength is not affected by
chlorides and moisture into the concrete and by RHEOCRETE®222+.
forming a strong, durable protective film on the
reinforcing steel for a second level of corrosion Corrosion inhabiting systems
protection. This dual mechanism system makes In order to control corrosion in steel reinforced
RHEOCRETE®222+ effective with all cement concrete, the ACI Building Code (ACl 318) requires
factors, as well as in cracked concrete where the certain design considerations, such as limiting the
elements that cause corrosion have direct access to water-cementitious materials ratio; providing
the reinforcing steel. adequate concrete cover over reinforcing steel; and
limiting the initial chloride ion content of the
How it works concrete. Additionally, construction practices should
RHEOCRETE®222+ functions by inhibiting corrosion be such that a dense, void-free concrete is obtained.
at its most critical points. RHEOCRETE®222+ lines
In addition to the elements of good concrete practice
the pores of the concrete matrix thus slowing the
required by the ACI Building Code, BASF
rate at which chlorides and moisture enter the
Construction Chemicals recommends a corrosion
concrete and denying the corrosion process of its
inhibiting system that inhibits corrosion at multiple
two most important components.
levels for maximum protection. The basis for this
system can be established through the use of
RHEOCRETE®222+ provides additional protection by
RHEOCRETE®222+, which restricts the ingress of
adsorbing onto the reinforcing steel to form a
chlorides and moisture and slows the rate of
corrosion resistant protective film. This protective
corrosion by forming a protective film on the
film dramatically slows the corrosion process by
reinforcing steel. Additional protection can be
preventing chlorides from reacting with the
attained through the use of high-range water-reducing
reinforcing steel, and by depriving the corrosion
admixtures to provide adequate placeability and
process of moisture and oxygen, thus slowing the
consolidation at low water-cement
rate of corrosion once it begins.
RHEOCRETE®222+
ratios and/or the use of silica fume admixtures to Non chloride
reduce concrete permeability. RHEOCRETE®222+ will not initiate or promote
corrosion of reinforcing steel embedded in concrete,
Dosage prestressed concrete or concrete placed on
RHEOCRETE®222+ is recommended for use at a galvanised steel floor and roof systems. Neither
dosage rate of 5 litre / m³ of concrete for all calcium chloride nor any chloride-based ingredients
applications and corrosion environments. are used in the manufacture of RHEOCRETE®222+
RHEOCRETE®222+ dosed at 5 litre / m³ is corrosion inhibiting admixture.
formulated to provide optimum corrosion protection
of reinforced concrete structures in severe corrosive Packaging
environments, and therefore provides excellent RHEOCRETE®222+ is available in 208 litre drums
corrosive protection in less severe corrosion and bulk if required.
environments as well. RHEOCRETE®222+ is
formulated for use at a single dosage in order to Storage
eliminate the confusion and uncertainties related to POZZOLITH®Standard must be stored where
determining the severity of the corrosive temperatures do not drop below +5oC. If product
environment and predicting the chloride exposure of has frozen thaw and agitate until completely
the structure. reconstituted. Store under cover, out of direct
sunlight and protect from extremes of temperatures.
Directions for use
RHEOCRETE®222+ may be added with concrete Safety precautions
batch water. It should not be mixed with any other POZZOLITH®Standard is not a fire or health hazard.
admixtures prior to being introduced into the Spillages should be washed down immediately with
concrete mixer. The use of this admixture does not cold water. For further information refer to the
require changes in normal batching procedures. material safety data sheet.

Watchpoint Note
Trials must be carried out to ensure mix design Field service, where provided, does not constitute
meets specified performance criteria. supervisory responsibility. For additional information
contact your local BASF Construction Chemicals SA
Temperature precaution representative.
Store at ambient temperatures above 2°C but not
exceeding 52°C. Precautions should be taken to Quality and care
protect RHEOCRETE®222+ from freezing. If product All products originating from BASF Construction
freezes, thaw and reconstitute by mild mechanical Chemicals SA, are manufactured under a
agitation. Do not use pressurised air for agitation. management system independently certified to

Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is
given or implied with any recommendations made by us, our representatives or distributors, as the conditions of use and the
competence of any labour involved in the application are beyond our control.
As all BASF’s technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.
BASF Construction Chemicals South Africa (Pty) Ltd
852 Sixteenth Road, Midrand
P.O. Box 420, Westonaria, 1780
PO Box 2801, Halfway House, 1685
11 Pullinger Street, Westonaria, 1779 Tel: +27 11 203 2405
Tel: +27 11 754 1343
Fax: +27 11 754 1105 Website : basf-cc.co.za
e-mail: basfcc@mweb.co.za
RHEOCRETE®222+
conform to the requirements of the quality standards
ISO 9001/2000

Whilst any information contained herein is true, accurate and represents our best knowledge and experience, no warranty is
given or implied with any recommendations made by us, our representatives or distributors, as the conditions of use and the
competence of any labour involved in the application are beyond our control.
As all BASF’s technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.
BASF Construction Chemicals South Africa (Pty) Ltd
852 Sixteenth Road, Midrand
P.O. Box 420, Westonaria, 1780
PO Box 2801, Halfway House, 1685
11 Pullinger Street, Westonaria, 1779 Tel: +27 11 203 2405
Tel: +27 11 754 1343
Fax: +27 11 754 1105 Website : basf-cc.co.za
e-mail: basfcc@mweb.co.za

You might also like