Professional Documents
Culture Documents
Bollfilter 1.03.02 PDF
Bollfilter 1.03.02 PDF
Filter for
Shipbuilding and
Diesel Engines
10.10.2002 PC 134-00
BOLLFILTER
Protection Systems
S a f e t y n e e d s q u a l i t y.
P R O T E C T Y O U R I N V E S T M E N T ...and more.
A company profile of
BOLL & KIRCH Filterbau GmbH
WHY THIS PROFILE?
A new millennium is just round the corner. Today, BOLL & KIRCH has never been better
Like every other company, BOLL & KIRCH will prepared in the world market for fluids filters.
need all its strength to face the challenges of This brochure presents the company’s current
the “Global Village” and “Dynamic Change”. position and the basic elements of its strategy for
Yet, this is nothing new for our company. For achieving success in the 21st century. And when
decades our direction has been determined by you have finished your reading, we look forward
the international market and hence, in the end, to discussing your needs and expectations.
the customer.
The Management
ta r
ur
1
ge
O
t
wo
No.
rl
e
d-wid
CONTENTS
T H E TA S K
THE MARKET
THE PERFORMANCE
THE PRODUCT
T H E F O U N D AT I O N
THE TEAM
T H E O R G A N I S AT I O N
4
T H E TA S K
Surface,
Type
Sea, Crude,
River, Mineral,
Borehole water Synthetic oil- Mineral oil-
Cooling
Water Oil Fuels Chemicals lubricants
Sealing Storage
Swimming pool Machine circulation
Washing water Waste oil
S a f e t y n e e d s q u a l i t y. 5
C A P I TA L I N V E S T M E N T S R E Q U I R E
wealth.
6
THE MARKET
S a f e t y n e e d s q u a l i t y. 7
Testing a filter cloth for dimensional stability and
weaving errors in the Quality Assurance Department.
S P E C I A L I S AT I O N B R I N G S
TY
Y
L
ding position in the field. And with a Quality IS O
90 01
Management System certified under DIN/ISO 9001,
of our own research and development, and are Regular quality tests of filter
candles guarantee BOLLFILTERS
protected by patent. their high safety standards.
8
THE PERFORMANCE
operating costs.
Experts in dialogue:
Through dialogue with custo-
mers, customised and systems-
optimised solutions are indivi-
dually developed.
Safety needs quality.
S a f e t y n e e d s q u a l i t y. 9
7 7
4 3 7 6 6
4 6
5 6
4 6
1
4 2
4 4
A filtration medium in the form of a cloth insert surface. And more: through the optimum com-
is the heart of every fluids filter. It essentially bination of core components every fluid can
consists of a supporting body with a filter mesh. achieve the desired degree of cleanliness.
10
THE PRODUCT
Twill weave
One warp thread is woven around two weft threads and vice
versa. This weave is elastic and easily shaped. The filtration
range is between 30 and 80 µm.
Special twist
The optimised braid weave is a combination of strong threads
for really high strength and thin threads for the narrowest pore
cross-section. Its special weave permits high dirt capture on
the filter surface. It is the ideal mesh for all backflush candles,
with high free flow cross-section and low flow resistance for a
filtration range of 10-70 µm.
S a f e t y n e e d s q u a l i t y.
▲
15
T h e B O L L F I LT E R - p r o d u c t r a n g e
BOLLFILTER products are integrated into suction They are designed to National and International
and pressure pipes and protect important plant standards and norms. Continuous or disconti-
components such as valves, pumps and bearings nuous operation, manual or fully automatic filter
from abrasive particles and choking. The filter cleaning are the determinants of filter choice.
housing consists of grey cast iron, nodular cast
BASIC
BOLL-Simplex Filter Simplex filters are the basic model of filter fluids
ments.
DOUBLE
BOLL-Duplex Filter over to the clean filter side without any pulse
filter chambers.
exceeds a tolerance threshold, the unit can switch Three-way ball valve Change-over cock
11
SELFCLEAN SELFCLEAN
TYPE 6.19
BOLL- Automatic Filter
process is totally automated. Type 6.18 becomes Type 6.19 by the incorpora-
Filter is water filtration, hence its internal parts SELFCLEAN Type 6.62 is a new development
are generally stainless steel. The product uses the especially designed for smaller flow rates of fuels
very efficient Crossflow-Reverseflow backflush and lubricating oils. The special design allows
system. The filter candle is open at both ends filter finenesses down to 10 µm. When in use as
and filtration takes place from the inside out. In a fuel filter there is also a facility for integrating a
the longitudinal wedge wire design it is ideal for bypass filter with change-over mechanism.
fibrous contaminants.
▲
SELFCLEAN SELFCLEAN
TYPE 6.61 TYPE 6.46
This BOLL Automatic Filter meets the highest This compact filter for horizontal or vertical fitting
demands for filtering moderate or large flows of is employed chiefly in lubricating oil systems as a
oil, washing solutions or fuels. The combination continuous cleaning unit. Its turbine-driven con-
of a flushing process dependent on the differential stantly revolving flush mechanism operates free
pressure and the multi-chamber system achieves from wear even with low flow rates and pressu-
the highest solids separation of any automatic res. The fine-grade filter candles are stable under
filter. Backflush is aided by compressed air and differential pressures of up to full operating pres-
sure cleaning whilst independent of the system backflush provides uniform cleaning over the en-
pressure. Hence, pressure fall in the system and tire candle length. A safety filter and an overflow
the flushing volume are very low. An electronic safety device at the first stage provide safety in
contamination.
▲
THE PRODUCT
B O L L F I LT E R S a t a g l a n c e
ic ing
ne ine
al
g
ts
rs
er
s
in
ic
an
br ol
ea al
el
at
at
lu Co
cl lk
Fu
W
ic
he
A
br
C
Lu
BASIC
Simplex Filter
DOUBLE
Duplex Filter
SELFCLEAN
Automatic Filter
Type 6.18
Type 6.19
Type 6.23/6.24
Type 6.41
Type 6.46
Type 6.60/6.61
Type 6.62
TOPSYSTEMS
Filter plants
Filtrator
Type 8.61
Precoat Filter
Type 8.35
S a f e t y n e e d s q u a l i t y. 14
RESOURCES OFFER
16
T H E F O U N D AT I O N
optimal functioning of the end product are manu- Special tools for economic
manufacture with CNC and
factured in-house. Manufacturing sequences are DNC-controlled machine
tools.
constantly reviewed and optimised by our teams,
down.
Management
Filter elements
▲
Auxiliary plants
manufacture
▲
Bonded ▲
warehouse
Mechanical
▲
▲
▲
Assembly
processing
Delivery:
Cast iron parts, ▲
metal sheets
Packing,
▲
▲
▲
Plant construction
S a f e t y n e e d s q u a l i t y. 17
Das BOLL- Fertigungs-
The BOLL m a n u f a c kt ounrzienpg
t concept
of achieving this.
the world.
Right:
Interim inspection of a BOLL
Automatic Filter, SELFCLEAN
Type 6.18.
18
T H E F O U N D AT I O N
Left:
Final inspection and function
testing under high load in a clas-
sification society test.
Below:
Flexible operating manufacturing
teams hold daily meetings about
the tasks in hand.
manufacturing areas.
24 hours.
Genuine Parts
S a f e t y n e e d s q u a l i t y. 19
PERFORMANCE OPENS UP
BOLL & KIRCH currently employs over 250 staff, Solid external qualifications and on-going internal
many of them the second or third generation of training are a matter of course. Performance is
their family to do so. They are the company’s encouraged and promoted. Together with team
most valuable asset, because their skills decide spirit and a feeling of “in-ness” these features go a
the quality of products they manufacture. Years long way to explaining BOLL & KIRCH’s success.
of vocational training and experience within the And more: commitment and willingness to deliver
company are the rule, and at the same time evi- give individuals the chance to link their personal
dence of the steadfast links between employees success with that of the company.
20
THE TEAM
S a f e t y n e e d s q u a l i t y. 21
PRESENCE LEADS TO
BOLLFILTERS originally won their outstanding bal presence in all important industrial centres in
reputation in the marine industry. From the start turn generates new growth trends.
BOLLFILTER products were at home on the high The company’s presence thus forms a stable basis
seas. Then they progressed to many other areas for further expansion in the 21st century.
and are today used all over the world. To meet And more: it guarantees customers throughout
constantly rising demand BOLL & KIRCH has built the world reliability and depth of service.
22
T H E O R G A N I S AT I O N
OY Insalko AB Brazil
FIN - 00181 Helsinki Petersen Matex Ltd.
BR-20093-900 Rio de Janeiro
France
SOFFIL Asia
F - 78200 Mantes la Jolie India
A.K. Dutta
Germany
IND-Serampore 712203 West-Bengal
BOLL & KIRCH Filterbau GmbH
D - 50170 Kerpen People’s Republic of China, inc. Hong Kong /
Macao
BOLL & KIRCH Filterbau GmbH
Branch Office North B + V Industrietechnik GmbH
D -22926 Ahrensburg HK - Hong Kong
FILTERKON Australasia
GR - Athens 10677 Australia
Italy Peacock & Smith Pty Ltd.
DeCoSta S.R.L. AUS - Kensington Vic. 3031
I - 20156 Mailand Africa
Netherlands South Africa
Lubrafil B.V. Filpro (PTY) Ltd.
NL - 3084 CB Rotterdam ZA - Isando, 1600
Romania
Total Trading S.R.L. Sales bureau Warehouse Service Centre
R-6200 Galatz
S a f e t y n e e d s q u a l i t y. 23
BOLLFILTER
Protection Systems
1. Liquid to be filtered
pH-degree
12. Quantity
14. Remarks/accessory
Europa / Europe
Deutschland/Germany
BOLL & KIRCH Filterbau GmbH Cyprus
Postfach 1420, 50143 Kerpen SRS Ing.büro für Filtertechnik GmbH
Siemensstr. 10-14, D-50170 Kerpen Werkstrasse 9
Tel.: +49/2273/562-0 25497 Prisdorf
Fax.: +49/2273/562-223 Tel.: +49/4101/474-235
E-Mail: info@bollfilter.de Fax.: +49/4101/474-232
Croatia Netherlands
Marine Trade d.o.o. Lubrafil B.V.
Vladimira Nazora 6 Aalborg 2
HR-47000 Karlovac, Kroatien NL - 2993 LB Barendrecht
Tel.: +385-47-61 13 65 Tel.: +31/180/556255
Fax.: +385-47-61 42 81 Fax.: +31/180/556265
E-Mail: hidring-karlovac@ka.hinet.hr E-mail: lubrafil@lubrafil.nl
PC003-98/09.05.2003
Russia / Ukraine / Belorussia Asien / Asia
Dr. Alexej Simakov Hongkong/P.R. of China/Macao
P.O. Box 133 BVI Marine Systems Ltd.
RUS - 198262 St. Petersburg HK - Hong Kong SAR
Tel. + Fax.: +7/812/15 23 04 4 Tel.: +852-3181 7830
E-Mail: simakov@rol.ru Fax.: +852-2541 2171
E-mail: info@bv-industrie.com.hk
Spain/Portugal
Bollfilter España India
World Trade Center A.K. Dutta
Muelle de Barcelona IND - Navi Mumbay 400614
Edificio Este - 6a planta Tel.: +91/22/75 60 147
E - 08039 Barcelona Fax.: +91/22/75 60 146
Tel.: +34- 93-508-8784
Fax.: +34-93-508-8785 Japan/Taiwan
E-mail: Martinez@bollfilter.de MISUZU Machineries & Eng. Ltd.
Japan / Kobe 650-0023
Switzerland/Liechtenstein/Poland Tel.: +81/78/35 12 20 4
Equipement Industriel Genève S.A. Fax.: +81/78/35 16 35 4
120 Route de Frontenex E-Mail: international@misuzu-machineries.co.jp
CH - 1208 Genève
Tel.: +41/22/73 59 50 0 Singapore / Malaysia / Indonesia
Fax.: +41/22/78 66 17 1 MNM Corporation Pte. Ltd.
E-Mail: info@eig-sa.ch SGP - Singapore 629021
Tel.: +65/86 14 22 2
Turkey Fax.: +65/86 24 22 2
Ares Ltd. E-Mail: mnmcorp@mbox4.singnet.com.sg
DES Sanayi Sitesi
117.Sokak C24 Blok South Korea
81260 Y.Dudullu / Istanbul Blohm & Voss (Korea) Ltd.
Tel: + 90 (0) 216 4996252 Pbx ROK - Pusan / Korea
Fax: + 90 (0) 216 4996276 Tel.: +82/51/74 05 70 1
Fax.: +82/51/74 05 70 4
U.K. and Ireland E-Mail: bvkorea@kornet.net
BOLLFILTER UK LTD
Commerce Park, Whitehall Road Australien / Australia
GB - Colchester, Essex C02 8HX Peacock & Smith Pty Ltd.
Tel.: +44-120679 22 34 AUS - Kensington Vic. 3031
Fax.: +44-1206-79 30 04 Tel.: +61/39/37 64 49 9
E-Mail: john@bollfilteruk.co.uk Fax.: +61/39/37 62 16 5
E-Mail: filters@peacocks-aus.com
Amerika / America
BOLL FILTER CORPORATION Afrika / Africa
USA - Plymouth, MI 48170 South Africa
Tel.: +1 -734-451-4680 Afrifil Industrial Filters (Pty) Ltd.
Fax.: +1 -734-451-4681 ZA - Isando, 1600
E-Mail: latorre@bollfilterusa.com Tel.: +27/11/452 5444
Fax.: +27/11/609 9535
Motor-Services Hugo Stamp, Inc. E-Mail: stachelr@afrifil.co.za
USA - Ft. Lauderdale, Florida 33315
Tel.: +1 (954) 763-3660 United Arabian Emirates
Fax.: +1 (954) 763-2872 Middle East
M/S Safe Technical Supply Co. L.L.C.
Brazil P.O. Box 4832
Petersen Matex Ltd. Dubai
BR - 20093-900-Rio de Janeiro Tel.: +971-4-3243240
Tel.: +55/21/2211-5050 Fax.: +971-4-3243786
Fax.: +55/21/2518-2220 E-Mail: safetech@emirates.net.ae
E-Mail: Max.Herrmann@pml.com.br
PC003-98/09.05.2003
WN211
01.89
DURCHFLUSSRICHTUNG
FLOW DIRECTIONS
DIRECTION DE PASSAGES
MANTELSIEB
MULTIMANTLE FILTER-ELEMENT
PANIER À MANTÈAUX
GEWEBEEINSTECKKERZEN-EINSATZ KORBSIEB STERNSIEB
FILTER-CANDLE INSERT BASKET FILTER-ELEMENT STAR PLEATED-ELEMENT
ÉLÉMENTS À BOUGLES' PANIER À CORBEILLE TREILLIS PLISSÉ
RUECKSPUELBARES KORBSIEB RING
RINGSIEB
BACK WASH FILTER-ELEMENT FILTER-ELEMENT
PANIER POUR RINCAGE PARCONTRE-COURANT PANIER À ANNEAUX
EINFACHFILTER
SINGLE FILTER
FILTRE SIMPLE
DOPPELFILTER
DUPLEX FILTER
FILTRE DOUBLE
steel- and
Z100272 1.94.2 20-65 stainless steel basket- or star-pleated element
casting
steel- and
Z100674 1.94.2.6 20-65 stainless steel steam heating jacket
casting
basket-element
Z45538 1.01.2 65-200 cast iron quick opening device
or cover with bolts
cast iron
Z45537 1.03.2.4 65-300 steam heating tube
nodular cast iron
10.10.2002 PC 134-00
Z45547
TYP 1.35.2
01.05.1991
S N1 EINTRITT
INLET
ENTRÉE
N2 AUSTRITT
OUTLET
E
SORTIE
N2 N1
RE ENTLÜFTUNG G1/4
AIR ESCAPE G1/4
DÉSAÉRATION G1/4
RS ENTLEERUNG G1
DRAIN G1
VIDANGE G1
Q
øD S SIEBAUSBAU
C
RS GEHÄUSE : GRAUGUSS
CASING : CASTIRON
RE CORPS : FONTE
øB
= =
N1 + N2
MUFFENVERBINDUNG
BELL AND SPIGAT JOINT
JOINT OU ASSEMBLAGE ÁMANCHONS OU Á EMBOÎTEMENT
TYP øG Q DN
BESTELLBEISPIEL
ORDERING EXAMPLE 1.35.2 90 95 G1
EXEMPLE DE COMMANDE
VOL.
øG Q DN B C øD E X S L
KG
90 95 G 1/2 118 248 65 37 202 170 1 10
90 95 G 3/4 118 248 65 37 202 170 1 10
90 95 G1 118 248 65 37 180 170 1 10
110 260 G1 1/4 152 418 85 45 298 300 2.7 17
110 260 G1 1/2 152 418 85 45 298 300 2.7 17
110 260 G2 152 418 85 45 270 300 2.7 17
N1 FILTEREINTRITT
POS.1 FILTERINLET
ENTREÉ DE FILTRE
S
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
N2
N1/N2 NACH DIN2501PN40 GEBOHRT
N1/N2 DRILLED ACC. TO DIN2501 PN40
N1/N2 PERCÉE D'APRÉS DIN2501 PN40
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THEFILTER ELEMENT
RE RS DÉMONTAGE DU PANIER
TYP øG Q DN
BESTELLBEISPIEL
ORDERING EXAMPLE 1.14.2 110 210 40
EXEMPLE DE COMMANDE
DN PN/ VOL.
øG Q A øB C øD E S KG
N1/N2 120°C L
90 95 25 40 118 230 65 55 170 0.9 8
145 32 200 +3 265 60 220 1.2 9.5
210 40 250 +3 350 300 2.3 13.5
110 40 142 85 75
260 50 260 +3 400 350 2.7 16.5
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N1 FILTEREINTRITT
POS.1 FILTERINLET
ENTREÉ DE FILTRE
S
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
N2 N1/N2 NACH DIN2501 PN40 GEBOHRT
N1/N2 DRILLED ACC. TO DIN2501 PN40
N1/N2 PERCÈE D'APRÈS DIN2501 PN40
BEI KORBSIEB DURCHFLUSS ENTGEGENGESETZT
WITH BASKET ELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À CORBEILLE LE PASSAGE
N1 EST EN SENS CONTRAIRE
N3
N3 DAMPFEINTRITT G1/2
STEAM INLET
D'ADMISSION DE LA VAPEUR
N4 KONDENSATAUSTRITT G1/2
CONDENSATE OUTLET
CONDENSE EMERGENCE
N4
RE ENTLÜFTUNG G1/4
AIR ESCAPE
RS DÉSAÉRATION
RS ENTLEERUNG G1
DRAIN
VIDANGE
RE S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
DN PN/ VOL.
øG Q A øB C øD E K L M S KG
N1/N2 120°C LITER
95 25 230 55 85 170 0.9 8.5
90 40 200 +3 118 65 40 165
145 32 265 60 95 220 1.2 10
210 40 250 +3 350 145 300 2.3 14.5
110 40 142 85 75 70 190
260 50 260 +3 400 165 350 2.7 18
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
POS.1
N2 FILTERAUSTRITT
FILTEROUTLET
S
SORTIE DU FILTRE
N1/N2 NACH DIN2501 PN40 GEBOHRT
N1/N2 DRILLED ACC. TO DIN2501 PN40
N2
N1/N2 PERCÉE D'APRÈS DIN2501 PN40
E
DN
BEI KORBSIEB DURCHFLUSS ENTGEGENGESETZT
WITH BASKET ELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS Á CORBEILLE LE PASSAGE
EST EN SENS CONTRAIRE
OG N1
OD RE ENTLÜFTUNG G1/4
C
Q
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
OM VERSCHRAUBUNG PG11
RS SCREWING
BOULONNAGE
A ELEKTR. HEIZUNG AUS STAHL
ELECTRICAL HEATING OF CARBON STEEL
CHAUFFAGE ELECTRIQUE EN ACIER
S N1 EINTRITT
INLET
ENTRÉE
N2 AUSTRITT
OUTLET
SORTIE
E
RE ENTLÜFTUNG G1/4
AIR ESCAPE
N1 N2 DÉSAÉRATION
RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
Q
øD
C
øG Q PN/
DN 120°C B C øD E K øP S øT øUxz V X VOLUMEN GEW.
L KG
N1 EINTRITT
INLET
ENTRÉE
S
N2 AUSTRITT
OUTLET
SORTIE
E
N3 DAMPFEINTRITT G1/2
STEAM INLET
D ADMISSION DE LA VAPEUR
N1 N2
N4 KONDENSATAUSTRITT G1/2
CONDENSATE OUTLET
OD CONDENSE EMERGENCE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
C
Q
DÉSAÉRATION
OG
N3 N4 RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
HEIZMANTEL: STAHL
OP
OT
DN
AUSFÜHRUNG I N1 FILTEREINTRITT
DESIGN I FILTERINLET
EXÉCUTION I ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
N1 RS ENTLEERUNG
S
DRAIN
VIDANGE
N2
S SIEBAUSBAU
DISMOUNTING OF THE FILTERELEMENT
øD
H
DÉMONTAGE DU PANIER
K
C
Q
E
øG
GEHÄUSE GEGOSSEN
CASTED HOUSING
CORPS MOULE
TYP øG Q DN PN
e
BESTELLBEISPIEL
a ORDERING EXAMPLE 1.01.2 180 250 100 10
EXEMPLE DE COMMANDE
PN/
øG Q DN 120°C
A B C øD E H K S Z a øe s øl RE RS KP
120 175 65 235 140 255 185 195 400 145 490 117.5 53 2x12 15 4x18 G1/4 G1/2 18
154 205 80 260 167 300 200 220 430 160 600 130 65 2x12 15 8x18 G1/4 G1/2 24
SIEHE AUSFÜHRUNG
180 250 100 335 224 390 220 260 550 180 750 200 76 2x14 15 8x18 G1/4 G1/2 36
VOIR EXECUTION
SEE DESIGN
210 250 125 360 224 440 250 310 600 210 860 180 90 2x14 17 8x18 G1/4 G1 55
220 330 150 450 224 550 285 400 700 240 1030 225 90 2x14 17 8x22 G1/2 G1 58
300 500 200 500 270 750 340 570 905 295 1390 250 125 2x18 20 8x22 G1/2 G1 185
360 500 250 660 270 780 395 570 900 350 1500 330 145 2x18 20 12x22 G1/2 G1 225
DN 300-600 SEE TYP 1.09.2 DN 300-600 SIEHE TYP 1.09.2 DN 300-600 VOIR TYP 1.09.2
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
RE POS.1
N2 N1
VARIANTE II øZ
S
RS
VARIANTE III øZ
BODENBEFESTIGUNG
BOTTOM-FASTENING
FIXATION AU FOND
RS ENTLEERUNG
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT BESTELLBEISPIEL TYP øG Q DN PN
DÉMONTAGE DU PANIER ORDERING EXAMPLE
EXEMPLE DE COMMANDE 1.03.2 195 500 80 10
N2 N1
DN
S
H
C
OG
E
RS
X
T
J
X AUSTRITT EINTRITT
OUTLET INLET
M
ROHR
O21,3x3,2
N
N1 FILTEREINTRITT RE ENTLÜFTUNG
FILTERINLET AIR ESCAPE
ENTRÉE DE FILTRE DÉSAÉRATION
N2 FILTERAUSTRITT RS ENTLEERUNG
FILTEROUTLET DRAIN
SORTIE DU FILTRE VIDANGE
BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT PN BETRIEBSÜBERDRUCK HEIZRAUM
WITH RINGELEMENTS FLOW IN OPOSITE DIRECTION 14BAR BEI 200°C
AVEC DES PANIERS À ANNEAUX LE PASSAGE WORKING PRESSURE HEATING COMPARTMENT
EST EN SENS CONTRAIRE 14BAR AT 200°C
FUER KORBSIEBE NICHT GEEIGNET PRESSION DE SERVICE CHAMBRE DE
NOT QUALIFIED FOR BASKET FILTER ELEMENTS CHAUFFAGE 14 BAR À 200°C
N'EST PAS POUR PANIER À CORBEILLE
N1/N2 NACH DIN2501 PN10 GEBOHRT
N1/N2 DRILLED ACC. TO DIN2501 PN10
S SIEBAUSBAU N1/N2 PERCÉE D'APRÈS DIN2501 PN10
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER AUF WUNSCH, ON REQUEST, SUR DEMANDE
POS.1 DIFFERENZDRUCKANZEIGER
GEHAEUSE GEGOSSEN DIFFERENCE PRESSURE INDICATOR
CASTED HOUSING INDICATEUR DE DIFFERÉNCE DE PRESSION
CORPS MOULÉ
RE TRANSPORTÖSEN
TRANSPORTATION LOOP
ANSE DE TRANSPORT
POS.1
N1 FILTEREINTRITT DIN
FILTERINLET 2501
ENTRÉE DE FILTRE PN 10
N2 FILTERAUSTRITT DIN
FILTEROUTLET 2501
SORTIE DU FILTRE PN 10
RE ENTLÜFTUNG DIN
AIR ESCAPE 2501
DÉSAÉRATION PN 16
S
RS ENTLEERUNG DIN
DRAIN 2501
VIDANGE PN 16
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
RS
PN BETRIEBSÜBERDRUCK IN BAR BEI 60°C
WORKING PRESSURE IN BAR AT 60°C
PRESSION DE SERVICE EN BAR Á 60°C
GEHÄUSE GEGOSSEN
CASTED HOUSING
CORPS MOULÉ
BESTELLBEISPIEL
ORDERING EXAMPLE
EXEMPLE DE COMMANDE ANSCHLUSSMÖGLICHKEITEN
TYP øG DN PN POSSIBILITIES FOR CONNECTION
POSSIBILITEES POR CONNECTION
1.09.2 680 400 2.5
NR.1 NR.3
NR.2
S RE RS
SIEBFLAECHE
øG DN PN A C E H J K L M a h e f g s SIEVE AREA
GEW.
DN DN SURFACE FILTRANTE
KG
300 305
570 2.5 380 725 415 882 82.5 288 83 80 1320 20 40 280 480 27 340 540 25 5040 CM^2
350 320
400 455
680 2.5 480 835 460 990 77 343 114 125 1525 20 40 240 560 33 310 630 30 8150 CM^2
450 490
500 930
890 2.5 600 1140 640 1360 115 415 130 130 2130 50 50 280 750 33 360 830 35 16060 CM^2
600 950
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N2 N1
DN
S
H
C
OG
E
RS
X
T
J
X AUSTRITT EINTRITT
OUTLET INLET
M
ROHR
O21,3x3,2
N
N1 FILTEREINTRITT RE ENTLÜFTUNG
FILTERINLET AIR ESCAPE
ENTRÉE DE FILTRE DÉSAÉRATION
N2 FILTERAUSTRITT RS ENTLEERUNG
FILTEROUTLET DRAIN
SORTIE DU FILTRE VIDANGE
BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT PN BETRIEBSÜBERDRUCK HEIZRAUM
WITH RINGELEMENTS FLOW IN OPOSITE DIRECTION 14BAR BEI 200°C
AVEC DES PANIERS À ANNEAUX LE PASSAGE WORKING PRESSURE HEATING COMPARTMENT
EST EN SENS CONTRAIRE 14BAR AT 200°C
FUER KORBSIEBE NICHT GEEIGNET PRESSION DE SERVICE CHAMBRE DE
NOT QUALIFIED FOR BASKET FILTER ELEMENTS CHAUFFAGE 14 BAR À 200°C
N'EST PAS POUR PANIER À CORBEILLE
N1/N2 NACH DIN2501 PN10 GEBOHRT
N1/N2 DRILLED ACC. TO DIN2501 PN10
S SIEBAUSBAU N1/N2 PERCÉE D'APRÈS DIN2501 PN10
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER AUF WUNSCH, ON REQUEST, SUR DEMANDE
POS.1 DIFFERENZDRUCKANZEIGER
GEHAEUSE GEGOSSEN DIFFERENCE PRESSURE INDICATOR
CASTED HOUSING INDICATEUR DE DIFFERÉNCE DE PRESSION
CORPS MOULÉ
OFFSET - execution
welded carbon
Z45545 1.65.1 65-300 basket-, ring-, multimantle- or
steel
filter-candle element
INLINE - execution
welded carbon
Z100690 1.65.2 65-300 basket-, ring-, multimantle- or
steel
filter-candle element
OFFSET - execution
welded
Z45548 1.53.1 65-400 basket-, ring-, multimantle- or
stainless steel
filter-candle element
welded
Z45549 1.53.2 65-400 INLINE - execution
stainless steel
10.10.2002 PC134-00
Z45545
TYP1.65.1
22.07.1996
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
S
N1
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
DRAIN
VIDANGE
X
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
S = Q BEI MANTELSIEB
BY MULTIMANTLE-ELEMENT
POUR LES PANIERS À MANTEAUX
GEHÄUSE GESCHWEISST
HOUSING WELDED
RS CORPS SOUDÉ
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERENCE DE PRESSION
BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE 1.65.1 270 500 100 25
EXEMPLE DE COMMANDE
PN/ VOL.
øG Q DN A øB C E F H N O P S T U øZ RS KG
120°C L
250 65, 80 583 570 723 480 55 20
220 40 335 290 170 232 292 320 15 60 18 G1/2
500 80,100 838 815 978 745 80 30
500 100,125 874 835 1014 785 105 45
270 25 360 340 260 219 329 560 20 110 23 G1
750 125 1134 1085 1274 1025 130 60
500 150 916 860 1056 840 170 85
355 10 480 440 325 314 424 560 20 110 23 G1
750 150,200 1241 1110 1381 1110 190 110
750 200 1215 1110 1360 1120 230 155
420 10 590 510 360 383 493 560 20 110 23 G1
1000 250 1605 1440 1750 1260 260 205
520 1000 300 10 695 610 1610 1440 445 1755 492 602 560 1515 20 110 23 G1 300 320
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N1 FILTEREINTRITT
FILTERINLET
S
ENTRÉE DE FILTRE
N2 N2 FILTERAUSTRITT
FILTEROUTLET
POS.1 SORTIE DU FILTRE
N7 HEIZUNGSEINTRITT
HEATING INLET
ENTRÉE DE CHAUFFAGE
N8 HEIZUNGSAUSTRITT
X HEATING OUTLET
SORTIE DU CHAUFFAGE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
O21.3x2.9
DÉSAÉRATION
N8
RS ENTLEERUNG
DRAIN
VIDANGE
110
215
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
53
55
GEHÄUSE GESCHWEISST
RS 150 N7 HOUSING WELDED
CORPS SOUDÉ
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
BESTELLBEISPIEL INDICATEUR DE DIFFERÉNCE DE PRESSION
TYP øG Q DN PN
ORDERING EXAMPLE
EXEMPLE DE COMMANDE 1.65.1.4 270 500 100 16
PN/ VOL.
øG Q DN A øB E F H N O P S T U øZ RS KG
120°C L
250 50,65,80 655 868 270 57 20
220 16 335 290 170 232 292 320 15 60 18 G1/2
500 80,100 900 1123 520 82.5 30
500 100,125 920 1159 520 108 44
270 16 360 340 260 219 329 560 20 110 23 G1/2
750 125 1170 1419 770 133 59
500 150 945 1201 520 173 87
355 10 480 440 325 314 424 560 20 110 23 G1/2
750 150,200 1195 1526 770 193 112
750 200 1195 1445 770 233 157
420 10 590 510 360 383 493 560 20 110 23 G1/2
1000 250 1525 1835 1020 263 207
520 1000 300 10 695 610 1525 445 1840 492 602 560 1020 20 110 23 G1/2 303 322
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
POS.2
ENTRÉE DE FILTRE
N2
N2 FILTERAUSTRITT
FILTEROUTLET
DN
POS.1
SORTIE DU FILTRE
BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
N1 WITH RINGELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À ANNEAUX LE PASSAGE
A EST EN SENS CONTRAIRE
F
RE ENTLÜFTUNG G1/4
AIR ESCAPE
OG DÉSAÉRATION
C
X RS ENTLEERUNG
H
DRAIN
VIDANGE
E
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
POS.2 THERMOSTAT
THERMOSTAT
THERMOSTAT
215
GEHÄUSE GESCHWEISST
T
HOUSING WELDED
CORPS SOUDÉ
53
U RS
SCHWEISSTOLERANZEN EN ISO 13920-c
Z TOLERANCE EN ISO 13920-c
TOLÉRANCE EN ISO 13920-c
øG Q DN PN/ A øB C F H N O P S T U øZ RS KG VOL.
E L
120°C
220 250 50,65,80 16 335 290 713 655 170 808 232 292 320 270 15 60 18 57 20
G1/2 82.5 30
500 80,100 968 900 1063 520
270 500 100,125 16 360 340 1009 920 260 1099 219 329 560 520 20 110 23 G1/2 108 44
750 125 1269 1170 1368 770 133 59
355 500 150 10 480 440 1051 945 325 1141 314 424 560 520 20 110 23 G1/2 173 87
750 150,200 1376 1195 1466 770 193 112
420 750 200 10 590 510 1350 1195 360 1445 383 493 560 770 20 110 23 G1/2 233 157
1000 250 1740 1525 1835 1020 263 207
520 1000 300 10 695 610 1745 1525 445 1840 492 602 560 1020 20 110 23 G1/2 303 322
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
SINGLE FILTER
WITH ELEC.HEATING
EINFACHFILTER 1.65.1.5 FILTRE SIMPLE AVEC
CHAUFFAGE ELEC.
MIT ELEKTRISCHER HEIZUNG
Z100690
TYP1.65.2
07.10.1997
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
S
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
N1 N2 AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
GEHÄUSE GESCHWEISST
HOUSING WELDED
CORPS SOUDÉ
RS
SCHWEISSTOLERANZEN EN ISO 13920-C
TOLERANCE EN ISO 13920-C
TOLÉRANCE EN ISO 13920-C
U RE
X= A + 2xHÖHE DER GEWÜNSCHTEN ANSCHLUSSFLANSCHE
A + 2xHEIGHT OF THE WANTED CONNECTING FLANGES
A + 2xHAUTEUR DES BRIDES DÉSIRÉES
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE 1.65.2 270 500 100 10
EXEMPLE DE COMMANDE
DN PN/
øG øU Q A øB C E F H N O P S T U øZ RS KG VOLUMEN
MIN. MAX. 120°C LITER
250 445 390 585 350 103 23
220 270 65 100 16 360 335 195 280 350 320 15 60 18 G1/2
500 695 640 835 600 107 37
500 745 610 890 650 168 64
270 355 100 150 10 480 440 280 314 424 560 20 110 23 G1
750 995 860 1140 900 187 87
500 745 575 890 650 213 83
355 420 125 200 10 590 510 315 383 493 560 20 110 23 G1
750 995 825 1140 900 217 120
750 995 800 1140 900 253 187
420 520 150 250 10 695 610 340 492 602 560 20 110 23 G1
1000 1270 1075 1415 1150 274 243
750
520 600 200 300 10 SIEHE MASSBLATT Z39400
1000
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
N7 HEIZUNGSEINTRITT
HEATING INLET
ENTRÉE DE CHAUFFAGE
N8 HEIZUNGSAUSTRITT
N8 HEATING OUTLET
SORTIE DU CHAUFFAGE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
DRAIN
VIDANGE
RS
N7 S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
U GEHÄUSE GESCHWEISST
HOUSING WELDED
RE CORPS SOUDÉ
DN PN/ VOLUMEN
øG øU Q A øB E F H N O P S T U øZ RS KG
MIN. MAX. 120°C LITER
ENTREE DE FILTRE
POS.1 N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DESAERATION
RS ENTLEERUNG
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
U RS DEMONTAGE DU PANIER
POS.2 THERMOSTAT
THERMOSTAT
THERMOSTAT
GEHÄUSE GESCHWEISST
HOUSING WELDED
CORPS SOUDE
DN PN/ VOLUMEN
øG øU Q A øB C E F H N O P S T U øZ RS KG
MIN. MAX. 120°C LITER
N1 FILTEREINTRITT
FILTERINLET
S
OB N2 ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
POS.1 BEI KORB- ODER RINGSIEBEN DURCHFLUSSENTGEGENGESETZT
N1 WITH BASKET- OR RINGELEMENTS FLOW IN OPOSITE DIRECTION
DN
AVEC DES PANIERS À CORBEILLE OU À ANNE AUX LE PASSAGE EST
EN SENS CONTRAIRE
F
RE ENTLÜFTUNG G1/4
AIR ESCAPE
A DÉSAÉRATION
RS ENTLEERUNG
C
X
DRAIN
OG VIDANGE
H
S SIEBAUSBAU
DISMOUNTING OF THE FILTERELEMENT
E
DÉMONTAGE DU PANIER
GEHÄUSE GESCHWEISST
HOUSING WELDED
CORPS SOUDÉ
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCEPRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
O
N
P BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE 1.53.1 220 250 50 16
EXEMPLE DE COMMANDE
DN PN/ VOL.
øG Q A øB C E F H N O P S T U øZ RS KG
MIN. MAX. 120°C L
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
S
OB
N2 FILTERAUSTRITT
FILTEROUTLET
POS.1 SORTIE DU FILTRE
N1 BEI KORB- ODER RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
DN
F
WITH BASKET- OR RINGELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À CORBEILLE OU À ANNE AUX LE PASSAGE EST EN SENS CONTRAIRE
N2 RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
A DRAIN
C
VIDANGE
Q
X
S SIEBAUSBAU
H
GEHÄUSE GESCHWEISST
HOUSING WELDED
CORPS SOUDÉ
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE
EXEMPLE DE COMMANDE 1.53.2 220 250 50 16
DN PN/ VOLUMEN
øG øK Q A øB C E F H N O P S T U øZ RS KG
MIN. MAX. 120°C LITER
160 220 250 65 80 16 335 290 445 420 165 585 232 292 320 350 15 60 18 G1/2 44 13
250 445 390 585 350 55 23
220 270 50 125 16 360 340 195 219 329 320 15 60 18 G1/2
500 695 640 835 600 81 37
500 745 610 890 650 142 64
270 355 100 200 10 480 440 280 314 424 560 20 110 23 G1
750 995 860 1140 900 189 87
500 745 575 890 650 145 83
355 420 125 250 10 590 510 315 383 493 560 20 110 23 G1
750 995 825 1140 900 192 120
750 995 800 1140 900 195 187
420 520 150 300 10 695 610 340 492 602 560 20 110 23 G1
1000 1270 1075 1415 1150 246 243
750 955 740 1100 900 338 251
520 600 200 400 10 800 710 360 574 684 560 20 110 23 G1
1000 1210 995 1355 1150 363 318
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N1 FILTEREINTRITT
S
FILTERINLET
ENTREÉE DE FILTRE
N1 N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
POS.1 RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
X
DISMOUNTING OF THE FILTER ELEMENT
A DÉMONTAGE DU PANIER
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE 1.58.1 160 500 80 16
EXEMPLE DE COMMANDE
DN PN/ VOL.
øG Q A øB C E F H N O P S T U øZ KG
N1/N2 120°C L
65
500 80 881 1021 600 65 17
100
160 16 310 235 310 370 176 236 320 15 60 18
80
750 1130 1270 850 75 22
100
100
500 943 1083 600 105 45
125
270 16 400 340 350 395 219 329 560 20 110 23
100
750 1200 1340 850 125 60
125
125
500 1060 1200 600 170 85
150
355 10 480 440 420 470 314 424 560 20 110 23
150
750 1313 1453 850 190 110
200
200
420 750 10 590 510 1400 500 570 1540 383 493 560 850 20 110 23 230 155
250
250
520 750 10 695 610 1500 550 670 1640 492 602 560 850 20 110 23 280 330
300
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES
S N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
N1 FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
POS.1 RS ENTLEERUNG G1
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
A DÉMONTAGE DU PANIER
POS.1 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
TYP øG Q DN PN
BESTELLBEISPIEL
ORDERING EXAMPLE 1.78.1 160 500 80 16
EXEMPLE DE COMMANDE
DN PN/ VOL.
øG Q A øB C E F H N O P S T U øZ KG
N1/N2 120°C L
65
500 80 888 1028 600 65 17
100
160 16 310 235 310 370 176 236 320 15 60 18
80
750 1158 1298 850 75 22
100
100
500 960 1100 600 105 45
125
270 16 400 340 350 395 219 329 560 20 110 23
100
750 1230 1370 850 125 60
125
125
500 1050 1190 600 170 85
150
355 10 480 440 420 470 314 424 560 20 110 23
150
750 1330 1470 850 190 110
200
200
420 750 10 590 510 1400 500 570 1540 383 493 560 850 20 110 23 230 155
250
250
520 750 10 695 610 1500 550 670 1640 492 602 560 850 20 110 23 280 330
300
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
RE
OB
N1 FILTEREINTRITT
S
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
N2
N1 RE ENTLÜFTUNG DN20 DIN2633
AIR ESCAPE
DÉSAÉRATION
DN
H
RS ENTLEERUNG DN50 DIN2633
C
OG
DRAIN
VIDANGE
S SIEBAUSBAU
E
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
N
GEHÄUSE AUS C-STAHL GESCHWEISST
RS HOUSING WELDED OF CARBON STEEL
CORPS EN ACIER AU CARBONE SOUDÉ
A
40
0
16
q
ANSCHLUSSMÖGLICHKEITEN
POSSIBILITIES FOR CONNECTION
POSSIBILITEES POUR CONNECTION
NR.1 NR.3
NR.2
GEWICHT VOLUMEN ANZ.DECKEL- BRUTTO SIEB-
DN øG PN A L øB C E H J øK øM N S KG LITER SCHRAUBEN FLÄCHE CM²
400 600 2.5 975 475 710 1200 815 1300 150 780 400 350 1100 335 400 12 12250
500 800 2.5 1225 575 915 1275 900 1375 150 980 500 450 1020 590 525 16 15300
600 900 2.5 1350 600 1015 1400 800 1475 150 1080 600 500 1200 670 755 18 18370
700 1100 2.5 1510 690 1215 1400 830 1500 150 1280 600 600 1250 800 1165 22 22850
800 1200 2.5 1860 840 1315 1475 900 1585 150 1380 600 650 1200 836 1350 24 25500
1000 1300 2.5 2060 910 1415 1755 990 1855 150 1480 800 700 1485 960 1745 26 39270
1200 1500 2.5 2415 1065 1615 2055 1245 2155 150 1680 800 800 1800 1990 3500 30 45496
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
ENTRÉE DE FILTRE
N2
N2 FILTERAUSTRITT
FILTEROUTLET
DN
POS.1
SORTIE DU FILTRE
BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
N1 WITH RINGELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À ANNEAUX LE PASSAGE
A EST EN SENS CONTRAIRE
F
RE ENTLÜFTUNG G1/4
AIR ESCAPE
OG DÉSAÉRATION
C
X RS ENTLEERUNG
H
DRAIN
VIDANGE
E
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
POS.2 THERMOSTAT
THERMOSTAT
THERMOSTAT
215
GEHÄUSE GESCHWEISST
T
HOUSING WELDED
CORPS SOUDÉ
53
U RS
SCHWEISSTOLERANZEN EN ISO 13920-c
Z TOLERANCE EN ISO 13920-c
TOLÉRANCE EN ISO 13920-c
PN/ VOL.
øG Q DN A øB C E F H N O P S T U øZ RS KG
120°C L
220 250 50,65,80 16 335 290 713 655 170 808 232 292 320 270 15 60 18 G1/2 57 20
500 80,100 968 900 1063 520 82.5 30
500 100,125 1009 920 1099 520 108 44
270 16 360 340 260 219 329 560 20 110 23 G1/2
750 125 1269 1170 1368 770 133 59
500 150 1051 945 1141 520 173 87
355 750 150,200 10 480 440 325 314 424 560 770 20 110 23 G1/2 193 112
1376 1195 1466
420 750 200 10 590 510 1350 1195 360 1445 383 493 560 770 20 110 23 G1/2 233 157
1000 250 1740 1525 1835 1020 263 207
520 1000 300 10 695 610 1745 1525 445 1840 492 602 560 1020 20 110 23 G1/2 303 322
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
SINGLE FILTER
WITH ELEC.HEATING
EINFACHFILTER 1.65.1.5 FILTRE SIMPLE AVEC
CHAUFFAGE ELEC.
MIT ELEKTRISCHER HEIZUNG
INDEX
Chapter 4 Casted duplex filter
cast iron or
Z45540 2.04.5 25-80 basket- or star pleated element
nodular cast iron
INLINE - execution
Z100912 2.06.7 65-100 cast iron
basket-, ring-, candle-insert or multimantle element
cast iron or
Z100403 2.05.5 100-250 basket-, ring-, candle-insert or multimantle element
nodular cast iron
Z100923 25-32
basket-, star-pleated- or disposable elements
Z100677 2.29.2 50-65 nodular cast iron
double staged ball change over valve
Z100296 80-100
Z100955 25-32
steel- and basket-, star-pleated- or disposable elements
Z100632 2.93.2 50-65
stainless steel casting double staged ball change over valve
Z100958 80-100
PC 134-02
22.01.2003
Z101782
TYP 2.02.5.4
10.10.2002
POS.1
qB RE
S
N2
N1
OK
OG
O
F
C
OI
E
J
R
U
10
O21,3x3,2
30
33
OZ 50
N8 N7 RS
P N
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTER INLET FILTER OUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
N7 HEIZUNGSEINTRITT N8 HEIZUNGSAUSTRITT
HEATING INLET HEATING OUTLET
ENTRÉE DE CHAUFFAGE SORTIE DU CHAUFFAGE
A
GEHÄUSE GEGOSSEN
CASTED CASING
CORPS MOULÉ
POS.1
RE
qB
S
N2
N1
øK
O
F
øG
C
E
J
ØI
T
OZ
P RS N
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTER INLET FILTER OUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
S SIEBAUSBAU
DISMOUNTING OF THE FILTER ELEMENT
DÉMONTAGE DU PANIER
M FILTERELEMENT : MANTELSIEB
L FILTER ELEMENT : MULTIMANTLE FILTERELEMENT
ELEMENT FILTRANT : PANIER Á MANTEAUX
AUF WUNSCH, ON REQUEST, SUR DEMANDE
GEHÄUSE GEGOSSEN
POS.1 DIFFERENZDRUCKANZEIGER CASTED CASING
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFF. DE PRESSION CORPS MOULÉ
BESTELLBEISPIEL TYP øG Q DN PN
ORDERING EXAMPLE 2.02.5 154 300 50 10
EXEMPLE DE COMMANDE
GEW. VOL.
øG Q DN PN/120°C A qB C E F J OK L M O S N OZ P OI T RS KG L
96 125 20 10 55 102 200 92 62 22 55 262 160 122 340 80 10 80 M10 17 G1/4 15 2x0,95
110 200 25 10 90 120 310 191 84 30 80 290 170 164 600 91 10 78 14 17 G1/4 25 2x2
126 175 32 10 95 140 260 128 84 25 80 360 220 170 500 110 10 110 14 17 G1/4 34 2x2,5
154 205 40 10 90 167 310 113 115 25 110 427 260 225 590 130 M12 130 14 24 G1/2 53 2x5
154 300 50 10 90 167 410 213 115 25 110 427 260 225 790 130 14 130 14 20 G1/2 65 2x6
P
F
C
DN
E
J
W
M
OD
L
g
RE X
b
e
~O
ANSICHT X d
VIEW X
VUE X a
f
140
DN C VOL.
øG Q A øD E F J L M ~O P S a b d e f g w LITER KG
MIN. MAX.
90 95 25 32 95 199 65 79 80 22 206 92 159 363 170 95 92 12 110 10 2X1 17
90 145 32 40 95 249 65 129 80 22 206 92 159 413 220 95 92 12 110 10 2X1 18
110 210 40 50 115 330 85 157 120 20 250 110 189 478 300 95 110 14 110 10 2X2 29
110 260 50 65 128 385 85 208 120 20 250 110 202 533 350 95 110 14 110 10 2X3 36
110 390 65 80 180 523 85 317 140 34 260 120 244 685 480 120 65 75 14 200 137 20 2X4 55
170 500 80 100 214 690 124 453 160 50 370 203 307 835 700 174 120 105 18 220 135 25 2X13 107
O21,3
P
Q
OK
C
DN
33
E
W
RS
J
OD
RE OG
w
M HEIZANSCHLÜSSE
L HEATING CONNECTION
CONNECTION DE CHAUFFAGE
X AUSTRITT EINTRITT
g OUTLET INLET
SORTIE ENTRÉE
b
e
~O
d
a ANSICHT X
VIEW
f VUE
140
BESTELLBEISPIEL TYP øG Q DN
ALLGEMEINTOLERANZEN DIN ISO 2768-V
ORDERING EXAMPLE 2.04.5.6 90 145 32 TOLERANCE DIN ISO 2768-V
EXEMPLE DE COMMANDE TOLÉRANCE DIN ISO 2768-V
DN VOL.
øG Q A C øD E F J L M ~O P S W a b d e f g w LITER KG X
MIN. MAX.
90 95 25 32 95 199 65 79 80 22 206 92 159 363 170 75 95 92 12 110 10 2x1 18 85u2
90 145 32 40 95 249 65 129 80 22 206 92 159 413 220 125 95 92 12 110 10 2x1 19 85u2
110 210 40 50 115 330 85 157 120 20 250 110 189 478 300 123 95 110 14 110 10 2x2 32 107u2
110 260 50 65 128 385 85 208 120 20 250 110 202 533 350 168 95 110 14 110 10 2x3 39 107u2
110 390 65 80 180 523 85 317 140 34 260 120 244 663 480 160 120 65 75 14 200 137 20 2x4 58 107u2
P
F
Q
OK
C
DN
m
E
J
W
M RS 4
OD
OG
RE X PG13.5
VERSCHRAUBUNG
SCREWING
g BOULONAGE
b
e
~o
d
a ANSICHT X
f VIEW X
VUE X
140
S SIEBAUSBAU
FOR DISMOUNTING THE FILTER ELEMENT
RE ENTLÜFTUNG G1/4 DEMONTAGE DU PANIER
AUF WUNSCH , ON REQUEST , SUR DEMANDE AIR ESCAPE G1/4
1 DIFFERENZDRUCKANZEIGER (DDA) DÉSAÉRATION G1/4
DIFFERENCE PRESSURE INDICATOR FLANSCHANSCHLUSS:
INDICATEUR DE DIFFÉRENCE DE PRESSION RS ENTLEERUNG G3/8 FLANGED JOINT:
DRAIN G3/8 RACCORD A BRIDÈS:
2 DDA-ANBAU U. DURCHFLUSSRICHTUNG F. STERNSIEBE VIDANGE G3/8
DPI-INSTALLATION AND FLOW DIRECTION STIFTSCHRAUBE DIN939
FOR STAR-ELEMENT STUD BOLT DIN939
BETRIEBSÜBERDRUCK: BOULON DIN939
IDP-ASSEMBLAGE ET DIRECTION DE PASSAGE WORKING PRESSURE:
POUR PANIERS À ETOILE DN K m
PRESSION DE SERVICE:
25 80 M10 M10 X 25
3 DDA-ANBAU U. DURCHFLUSSRICHTUNG F. KORBSIEBE GEHÄUSE GEGOSSEN AUS EN-GJL-250
25 BAR BEI 120°C 32 80 M10 M10 X 25
DPI-INSTALLATION AND FLOW DIRECTION
FOR BASKET-ELEMENT CASTED CASING OF EN-GJL-250
IPD-ASSEMBLAGE ET DIRECTION DE PASSAGE 25 BAR AT 120°C SECHSKANTSCHRAUBE DIN931
POUR PANIERS À CORBEILLE CORPS MOULÈ EN EN-GJL-250 SPANNER BOLT DIN931
25 BAR À 120°C VIS HEXAGONALE DIN931
4 ELEKTRISCHES HEIZELEMENT SCHUTZART IP43
ELECTR. HEAT ELEMENT SYSTEM OF POTEC.IP43 GEHÄUSE GEGOSSEN AUS EN-GJS-400-15 DN K m
ELECTR.CHAUFFAGE TYPE DE PROTECTION IP43 25 BAR BEI 120°C 40 100 ø14 M12 X 50
CASTED CASING OF EN-GJS-400-15 50 110 ø14 M12 X 50
TEMPERATURBEGRENZER 100-104°C 25 BAR AT 120°C 65 130 ø18 M16 X 50
TEMPERATURE DELIMITER 100-104°C CORPS MOULÈ EN EN-GJS-400-15
LIMITE DE TEMPERATURE 100-104°C 25 BAR À 120°C 80 150 ø18 M16 X 50
BESTELLBEISPIEL TYP øG Q DN
ALLGEMEINTOLERANZEN DIN ISO 2768-V
ORDERING EXAMPLE 2.04.5.7 90 145 32 TOLERANCE DIN ISO 2768-V
EXEMPLE DE COMMANDE TOLÉRANCE DIN ISO 2768-V
ELEKTR.
ELEMENT
DN VOL.
øG Q A C øD E F J L M ~O P S a b d e f g w 220V KG
MIN. MAX. WATT LITER
90 95 25 32 95 199 65 79 80 22 206 92 225 363 170 95 92 12 110 10 350 2X1 18
90 145 32 40 95 249 65 129 80 22 206 92 225 413 220 95 92 12 110 10 350 2X1 20
110 210 40 50 115 330 85 157 120 20 250 110 255 478 300 95 110 14 110 10 350 2X2 32
110 260 50 65 128 385 85 208 120 20 250 110 268 533 350 95 110 14 110 10 350 2X3 39
110 390 65 80 180 523 85 317 140 34 260 120 244 633 480 120 65 75 14 200 137 20 350 2X4 56
øB N2
S
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
øG BEI KORB- ODER RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
F
C
H
AVEC DES PANIERS A CORBEILLE OU A
ANNEAUX LE PASSAGE EST EN SENS CONTRAIRE
Q
E
POS.1 POS.2
RE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
P
RS ENTLEERUNG
DRAIN
VIDANGE
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
U
Z
DÈMONTAGE DU PANIER
N-10
KUGELSCHALTUNG: CRNI-STAHL
BALL COCK VALVE: STAINLESS STEEL
COMMANDE DE VITESSE A ROTULE: ACIER AU INOX
POS.1 DRUCKAUSGLEICH
EQUALIZATION OF PRESSURE
EQUILIBRAGE DE PRESSION GEHÄUSE AUS CRNI-STAHL GESCHWEISST
HOUSING OF STAINLESS STEEL WELDED
AUF WUNSCH ,ON REQUEST ,SUR DEMANDE CORPS EN ACIER AU INOX SOUDÉ
POS.2 DIFFERENZDRUCKANZEIGER SCHWEISSTOLERANZEN EN ISO 13920-C
DIFFERENCE PRESSURE INDICATOR TOLERANCE EN ISO 13920-C
INDICATEUR DE DIFFERÉNCE DE PRESSION TOLÉRANCE EN ISO 13920-C
S
N2
F
N1
OK
H
Q
C
Øl A
øG ØG=265 ØG=195
RS RS
E
J
J
T
N1 FILTEREINTRITT
POS.2 FILTERINLET
ENTRÈE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
BEI KORB- UND RINGSIEBEN IST DER
DURCHFLUSS ENTGEGENGESETZT
O
N
DN
N2
F
qD
H
C
RS
k
(ø195)
O 18 OG (ø265) A
E
RS N1
60
20
J
r
t
30
S
B
N2
N1
F
qD
H
Q
C
OI OG W A
RS
E
T
J
L
P N1 FILTEREINTRITT
FILTERINLET
M ENTRÉE DE FILTRE
POS.2 N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
BEI KORB- ODER RINGSIEB DURCHFLUSS ENTGEGENGESETZT
WITH BASKET-OR RING-ELEMENTS
FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS A CORBEILLE OU A ANNEAUX LE
PASSAGE EST EN SENS CONTRAIRE
N
* RE ENTLÜEFTUNG
AIR ESCAPE
G1/4
DÉSAÉRATION
O 14
* RS ENTLEERUNG
DRAIN
DN VIDANGE
OK S SIEBAUSBAU
DISMOUNTING OF THEFILTER ELEMENT
DÉMONTAGE DU PANIER
S=Q BEI MANTEL- UND RINGSIEB
BY MULTIMANTLE FILTERELEMENT AND RINGELEMENT
PN BETRIEBSÜBERDRUCK IN BAR BEI 120°C POUR LES PANIERS À MANREAUX ET PANIER ÀNNEAUX
WORKING PRESSURE IN BAR AT 120°C
PRESSION DE SERVICE EN BAR À 120øC * BEI G=265, SIND RS UND RE UM 180° VERSETZT
GEHÄUSE EN-GJL-25, GEGOSSEN BY G=265, RS AND RE 180° DISPLACED
CASE EN-GJL-25, CASTED POUR G=265, RE ET RS 180° DÉPLACÉ
CORPS EN-GJL-25, MOULÉ POS.1 DRUCKAUSGLEICH
ALLGEMEINTOLERANZEN DIN ISO 2768-V EQUALIZATION OF PRESSURE
TOLERANCE DIN ISO 2768-V ÉQUILIBRAGE DE PRESSION
TOLÉRANCE DIN ISO 2768-V
AUF WUNSCH, ON REQUEST, SUR DEMANDE
BESTELLBEISPIEL TYP øG Q DN POS.2 DIFFERENZDRUCKANZEIGER
ORDERING EXAMPLE DIFF.PRESSURE INDICATOR
EXEMPLE DE COMMANDE 2.06.7 265 500 80 INDICATEUR DE DIFF.DE PRESSION
DN GEW. Volumen
øG Q min. max. PN A B C qD E F H J L M S N W P øK øl U O T RS kg LTR.
195 250 65 80 10 135 q200 425 130 175 195 580 45 520 320 350 160 110 480 130 18 50 200 20 G1/2 75 2x10
195 500 80 100 10 155 q200 695 150 420 210 840 50 550 350 610 160 115 510 150 18 50 200 20 G1 120 2x17
685 150 420 210 840 65 685 415 150 18 65 20
* 265 500 80 100 10 165 270 600 220 125 640 265 G1 185 2x32
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
S
RE
ANORDNUNG DER FLANSCHE
DISPOSITION OF THE FLANGES
DISPOSITION DES BRIDES
N2 NR.1
F
N1 NR.2
C
I
Q
OD
OG A A
E
J
T
M N1 FILTEREINTRITT N2 FILTERAUSTRITT
RS U FILTERINLET FILTEROUTLET
R ENTRÉE DE FILTRE SORTIE DU FILTRE
S SIEBAUSBAU
AUF WUNSCH, ON REQUEST, SUR DEMANDE DISMOUNTING THE FILTER ELEMENT
POS.1 DRUCKAUSGLEICH DÉMONTAGE DU PANIER
EQUALIZATION OF PRESSURE
ÉQUILIBRAGE DE PRESSION * S=Q BEI MANTELSIEB
BY MULTI MANTLE ELEMENT
POS.2 DIFFERENZDRUCKANZEIGER POUR LE PANIERS À MANTEAUX
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION GEHÄUSE GEGOSSEN
CASING CASTED
CORPS MOULÉ
BESTELLBEISPIEL TYP øG Q DN ALLGEMEINTOLERANZEN DIN ISO 2768-v
ORDERING EXAMPLE TOLERANCE DIN ISO 2768-v
EXEMPLE DE COMMANDE 2.05.5 340 750 150 TOLÉRANCE DIN ISO 2768-v
S
ANORDNUNG DER FLANSCHE
DISPOSITION OF THE FLANGES
N2 DISPOSITION DES BRIDES
F
NR.1
N1
C
I
Q
OD NR.2
A A
OG
O21,3x3,2
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
J
DÉMONTAGE DU PANIER
160
T
W
* S=Q BEI MANTELSIEB
33 N8 N7 BY MULTI MANTLE ELEMENT
RS 10 POUR LE PANIERS À MANTEAUX
POS.2 L POS.1 50
øZ P
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
N1/N2 NACH DIN2501 ODER ASME B16.5 150 lbs sq.in.
N
S
N2
OG
F
N1
H
C
Q
E
DN
OK
J
RS Z
POS.1 N
POS.2
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
A
M N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED ACC.
TO PRESSURE CLASS
L
N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
GEHÄUSE GEGOSSEN, EN-GJS-400-15 SUIVANT ÉTAGE DE PRESSION
CASING CASTED, EN-GJS-400-15
CORPS MOULÉ, EN-GJS-400-15 BEI KORBSIEB DURCHFLUSS ENTGEGENGESETZT
WITH BASKET ELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À CORBEILLE LE PASSAGE EST
ALLGEMEINTOLERANZEN DIN ISO 2768-v EN SENS CONTRAIRE
TOLERANCE DIN ISO 2768-v
TOLÉRANCE DIN ISO 2768-v
RE ENTLÜFTUNG G1/4
AUF WUNSCH, ON REQUEST, SUR DEMANDE AIR ESCAPE
POS.1 DRUCKAUSGLEICH DÉSAÉRATION
EQUALIZATION OF PRESSURE
RS ENTLEERUNG G1/4
ÉQUILIBRAGE DE PRESSION DRAIN
POS.2 DIFFERENZDRUCKANZEIGER VIDANGE
DIFFERENCE PRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
BESTELLBEISPIEL TYP øG Q GR. DN
ORDERING EXAMPLE
EXEMPLE DE COMMANDE 2.29.2 110 250 02 25
S
N2
OG
H
F
N1
C
Q
E
RS POS.1 = = øe
20
J
M a
L
N1 FILTEREINTRITT
POS.2 FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
DN
RE ENTLÜFTUNG G1/4
AIR ESCAPE
OK DÉSAÉRATION
h RS ENTLEERUNG G1/2
DRAIN
VIDANGE
S SIEBAUSBAU
GEGEN AUFPREIS, AT EXTRA CHARGE , AVEC SUPPL. DE PRIX DISMOUNTING OF THE FILTERELEMENT
DÉMONTAGE DU PANIER
POS.1 DRUCKAUSGLEICH ALLGEMEINTOLERANZEN DIN ISO 2768-v
EQUALIZATION OF PRESSURE TOLERANCE DIN ISO 2768-v
EQUILIBRAGE DE PRESSION TOLÉRANCE DIN ISO 2768-v
POS.2 DIFFERENZDRUCKANZEIGER
DIFF. PRESSURE INDICATOR GEHÄUSE: EN-GJS-400-15
INDICATEUR DE DIFF. DE PRESSION CASING: CAST IRON WITH SPHEROIDAL
CORPS: FONTE SPHÉROLITIQUE
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq. in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq. in.
DRILLED ACC. TO PRESSURE CLASS
BESTELLBEISPIEL N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq. in.
ORDERING EXAMPLE PERCÉE SUIVANT ÉTAGE DE PRESSION
EXEMPLE DE COMMANDE
TYP øG Q GR. DN
2.29.2 200 250 05 50
N2
øB N1 FILTEREINTRITT
S
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
øG FILTEROUTLET
SORTIE DU FILTRE
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
F
C
TO PRESSURE CLASS
H
N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300lbs sq.in. PERCÉE
Q SUIVANT ÉTAGE DE PRESSION
E
M
T
RE ENTLÜFTUNG G1/4
AIR ESCAPE
POS.2 DÉSAÉRATION
RE RS ENTLEERUNG G1/2
DRAIN
VIDANGE
O
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
P
X
A
DN
q60
OD
ALLGEMEINTOLERANZEN DIN ISO 2768-v
N -10 TOLERANCE DIN ISO 2768-v
TOLÉRANCE DIN ISO 2768-v
S
N2
OG
H
F
N1
C
Q
E
O21,3x2,9
20
W
J
RS
33 ØZ 60
POS.1 N8 N7 = =
M N7, N8
N
L
POS.2
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTER INLET FILTER OUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
OD
N7 HEIZEINTRITT
P HEATING INLET
ENTRÉE DE CHAUFFAGE
N8 HEIZAUSTRITT
HEATING OUTLET
ALLGEMEINTOLERANZEN DIN ISO 2768-v SORTIE DU CHAUFFAGE
TOLERANCE DIN ISO 2768-v
TOLÉRANCE DIN ISO 2768-v BETRIEBSÜBERDRUCK HEIZRAUM 14 BAR BEI 200°C
WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
GEHÄUSE GEGOSSEN, EN-GJS-400-15 PRESSION DE SERVICE CHAMBRE DE CHAUFFAGE 14 BAR À 200°C
CASING CASTED, EN-GJS-400-15
CORPS MOULÉ, EN-GJS-400-15 RE ENTLÜFTUNG G1/4
AIR ESCAPE
AUF WUNSCH, ON REQUEST, SUR DEMANDE DÉSAÉRATION
POS.1 DRUCKAUSGLEICH RS ENTLEERUNG G1/2
EQUALIZATION OF PRESSURE DRAIN
ÉQUILIBRAGE DE PRESSION VIDANGE
POS.2 DIFFERENZDRUCKANZEIGER
DIFFERENCE PRESSURE INDICATOR S SIEBAUSBAU
INDICATEUR DE DIFFERÉNCE DE PRESSION DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
SIEBEINSATZ : MANTELSIEB
FILTER ELEMENT: MULTIMANTLE FILTERELEMENT
BESTELLBEISPIEL TYP øG Q GR. DN PN ELEMENT FILTRANT: PANIER À MANTEAUX
ORDERING EXAMPLE
EXEMPLE DE COMMANDE 2.29.2.4 200 250 05 50 40
S
N2
OG
H
F
C
Q
N1
E
20
J
W
RS
POS.1
M VERSCHRAUBUNG PG11
= =
SCREWING
BOULONNAGE N
L
POS.2 N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
A
DÉSAÉRATION
RS ENTLEERUNG G1/2
DN DRAIN
X
OD VIDANGE
3
P S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
ALLGEMEINTOLERANZEN DIN ISO 2768-v
TOLERANCE DIN ISO 2768-v SIEBEINSATZ : MANTELSIEB
TOLÉRANCE DIN ISO 2768-v FILTERELEMENT : MULTIMANTLE FILTERELEMENT
ELEMENT FILTRANT : PANIER À MANTEAUX
GEHÄUSE GEGOSSEN, EN-GJS-400-15
CASING CASTED, EN-GJS-400-15 N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq. in.
CORPS MOULÉ, EN-GJS-400-15 ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED ACC.
GEGEN AUFPREIS, AT EXTRA CHARGE, AVEC PRIX EXTRA TO PRESSURE CLASS
POS.1 DRUCKAUSGLEICH N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq. in.
EQUALIZATION OF PRESSURE PERCÉE SUIVANT ÉTAGE DE PRESSION
ÉQUILIBRAGE DE PRESSION
POS.2 DIFFERENZDRUCKANZEIGER HEIZLEISTUNG 450 WATT BEI 230 VOLT
DIFFERENCE PRESSURE INDICATOR HEATING POWER 450 WATT AT 230 VOLT
INDICATEUR DE DIFFERÉNCE DE PRESSION PUISSANCE DE CHAUFFAGE 450 WATT POUR 230 VOLT
S
RE POS.2
N2
OG
F
H
N1
N7
C
Q
E
DN
W
V
G1/2 Z
J
RS POS.1 N N8
Y
M
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTER INLET FILTER OUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
OD
X
S
N2
OG
F
H
N1
C
Q
E
Z
RS POS.1 VERSCHRAUBUNG PG11
N
J
SCREWING
POS.2 BOULONNAGE
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
S
N2
OG
F
H
N1
C
Q
E
N
J
Z
RS POS.1
L
POS.2
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in.
A
3
X
S
N2
OG
H
F
N1
C
Q
E
RS POS.1 = = øe
20
J
M a
L
N1 FILTEREINTRITT
POS.2 FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
DN AIR ESCAPE
DÉSAÉRATION
OK
RS ENTLEERUNG G1/2
DRAIN
h VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTERELEMENT
DÉMONTAGE DU PANIER
GEGEN AUFPREIS,AT EXTRA CHARGE,AVEC SUPPL. DE PRIX
ALLGEMEINTOLERANZEN DIN ISO 2768-v
POS.1 DRUCKAUSGLEICH TOLERANCE DIN ISO 2768-v
EQUALIZATION OF PRESSURE TOLÉRANCE DIN ISO 2768-v
ÉQUILIBRAGE DE PRESSION
POS.2 DIFFERENZDRUCKANZEIGER GEHÄUSE: STAHLGUSS ODER AUSTENITISCHER STAHLGUSS
DIFFERENCE PRESSURE INDICATOR CASING: STEEL CASING OR STAINLESS STEEL CASING
INDICATEUR DE DIFFERÉNCE DE PRESSION CORPS: ACIER COULÉ OU ACIER AUSTENITIQUE
NUR AUF ANFRAGE,ONLY ON REQUEST,UNIQUEMENT SUR DEMANDE N1/N2 NACH DIN2501 ODER ANSI B16.5 300 lbs sq. in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
PN > 32bar N1/N2 ACC. TO DIN2501 OR ANSI B16.5 300 lbs sq. in.
PN > 32bar DRILLED ACC. TO PRESSURE CLASS
PN > 32bar
N1/N2 D'APRÉS DIN2501 OU ANSI B16.5 300 lbs sq. in.
PERCÉE SUIVANT ÉTAGE DE PRESSION
BESTELLBEISPIEL
ORDERING EXAMPLE
EXEMPLE DE COMMANDE
TYP øG Q GR. DN
2.93.2 200 250 05 50
OB N2
S
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
OG
N2 FILTERAUSTRITT
F
FILTEROUTLET
SORTIE DU FILTRE
C
Q
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
H
E
N1 N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED ACC.
TO PRESSURE CLASS
N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
SUIVANT ÉTAGE DE PRESSION
J
SENS CONTRAIRE
RE ENTLÜFTUNG G1/4
N-10 AIR ESCAPE
DÉSAÉRATION
POS.2
RS ENTLEERUNG G1/2
RE DRAIN
VIDANGE
O
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
P
DÉMONTAGE DU PANIER
q60
POS.1 DRUCKAUSGLEICH
EQUALIZATION OF PRESSURE
ÉQUILIBRAGE DE PRESSION
S
N2
OG
H
F
N1
C
Q
E
O21,3x2,9
W
J
RS
33 ØZ 60
POS.1 N8 N7 = =
M N7, N8
N
L
POS.2
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTER INLET FILTER OUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
TO PRESSURE CLASS
N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
DN SUIVANT ÉTAGE DE PRESSION
3
OD
N7 HEIZEINTRITT
P HEATING INLET
ENTRÉE DE CHAUFFAGE
ALLGEMEINTOLERANZEN DIN ISO 2768-v N8 HEIZAUSTRITT
TOLERANCE DIN ISO 2768-v HEATING OUTLET
TOLÉRANCE DIN ISO 2768-v SORTIE DU CHAUFFAGE
GEHÄUSE: STAHL- ODER AUSTENITISCHER STAHLGUSS BETRIEBSÜBERDRUCK HEIZRAUM 14 BAR BEI 200°C
CASING: STEEL CASTING OR STAINLESS-STEEL CASTING WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
CORPS: ACIER COULÉ OU ACIER AUSTÉNITIQUE PRESSION DE SERVICE CHAMBRE DE CHAUFFAGE 14 BAR À 200°C
N1 FILTEREINTRITT N2 FILTERAUSTRITT
N2 FILTERINLET FILTEROUTLET
OB ENTRÉE DE FILTRE SORTIE DU FILTRE
S
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED ACC.
OG TO PRESSURE CLASS
N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
F
Q
BEI RINGSIEB DURCHFLUSS ENTGEGENGESETZT
C
WITH RING-ELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À ANNEAUX LE PASSAGE EST EN SENS CONTRAIRE
H
E
N7 HEIZEINTRITT Ø21,3x2,9
N1 HEATINGINLET
J
ENTRÉE DE CHAUFFAGE
POS.1
RS N8 HEIZAUSTRITT Ø21,3x2,9
N8 HEATINGOUTLET
110
255
SORTIE DU CHAUFFAGE
N7 55
T
150
WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
M PRESSION DE SERVICE CHAMBRE DE CHAUFFAGE 14 BAR À 200°C
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG G1/2
POS.2 DRAIN
q 80 VIDANGE
18
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
O
DÉMONTAGE DU PANIER
DN
X
OB RE O
S
N2
OG
H
F
C
Q
N1
E
20
J
W
RS
POS.1
M VERSCHRAUBUNG PG11
= =
SCREWING
BOULONNAGE N
L
POS.2 N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RE ENTLÜFTUNG G1/4
AIR ESCAPE
A
DÉSAÉRATION
RS ENTLEERUNG G1/2
DN DRAIN
X
OD VIDANGE
3
P S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DÉMONTAGE DU PANIER
ALLGEMEINTOLERANZEN DIN ISO 2768-v
TOLERANCE DIN ISO 2768-v SIEBEINSATZ : MANTELSIEB
TOLÉRANCE DIN ISO 2768-v FILTERELEMENT : MULTIMANTLE FILTERELEMENT
ELEMENT FILTRANT : PANIER À MANTEAUX
GEHÄUSE GEGOSSEN, EN-GJS-400-15
CASING CASTED, EN-GJS-400-15 N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq. in.
CORPS MOULÉ, EN-GJS-400-15 ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED
GEGEN AUFPREIS, AT EXTRA CHARGE, AVEC PRIX EXTRA ACC. TO PRESSURE CLASS
POS.1 DRUCKAUSGLEICH N1/N2 D'APRÈS DIN2501 OU ASME B16.5 300 lbs sq. in. PERCÉE
EQUALIZATION OF PRESSURE SUIVANT ÉTAGE DE PRESSION
ÉQUILIBRAGE DE PRESSION
POS.2 DIFFERENZDRUCKANZEIGER HEIZLEISTUNG 450 WATT BEI 230 VOLT
DIFFERENCE PRESSURE INDICATOR HEATING POWER 450 WATT AT 230 VOLT
INDICATEUR DE DIFFERÉNCE DE PRESSION PUISSANCE DE CHAUFFAGE 450 WATT POUR 230 VOLT
S
RE POS.2
N2
OG
F
H
N7
C
Q
E
N1
W
N8
V
G1/2 Z
J
RS N
POS.1 Y
M
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
AUF WUNSCH, ON REQUEST, SUR DEMANDE BETRIEBSÜBERDRUCK HEIZRAUM 14 BAR BEI 200°C
POS.1 DRUCKAUSGLEICH WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
EQUALIZATION OF PRESSURE PRESSION DE SERVICE CHAMBRE DE CHAUFFAGE 14 BAR À 200°C
ÉQUILIBRAGE DE PRESSION
POS.2 DIFFERENZDRUCKANZEIGER RE ENTLÜFTUNG G1/4
DIFFERENCE PRESSURE INDICATOR AIR ESCAPE
INDICATEUR DE DIFFERÉNCE DE PRESSION DÉSAÉRATION
NUR AUF ANFRAGE, ONLY ON REQUEST, UNIQUEMENT SUR DEMANDE RS ENTLEERUNG G1/4
PN > 32 BAR DRAIN
PN > 32 BAR VIDANGE
PN > 32 BAR
S SIEBAUSBAU
BESTELLBEISPIEL TYP øG Q GR. DN DISMOUNTING THE FILTER ELEMENT
ORDERING EXAMPLE DÉMONTAGE DU PANIER
EXEMPLE DE COMMANDE 2.93.2.6 110 250 02 25
S
N2
OG
F
H
N1
C
Q
E
Z
RS POS.1 VERSCHRAUBUNG PG11
N
J
SCREWING
POS.2 BOULONNAGE
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
BEI KORBSIEB DURCHFLUSS ENTGEGENGESETZT
WITH BASKET ELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS A CÓRBEILLE LE PASSAGE EST EN SENS CONTRAIRE
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
X
dimensional
filtertype connection material remarks
drwg.
10.10.2002 PC 134.00
Z100892
TYP 2.68.2
02.12.2002
øB N2
N1 FILTEREINTRITT
S
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
BEI KORB- ODER RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
øG WITH BASKET- OR RING-ELEMENTS FLOW IN OPPOSITE DIRECTION
F
C
H
EN SENS CONTRAIRE
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
Q
E
DÈMONTAGE DU PANIER
A
V
AUF WUNSCH, ON REQUEST, SUR DEMANDE AUF ANFRAGE, ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER HÖHERE BETRIEBSDRÜCKE
DIFFERENCE PRESSURE INDICATOR HIGHER WORKING PRESSURES
INDICATEUR DE DIFFERÉNCE DE PRESSION PRESSIONS DE SERVICE ÉLEVÉES
øB N2
S
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
øG BEI KORB- ODER RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
F
C
H
AVEC DES PANIERS A CORBEILLE OU ANNEAUX LE PASSAGE EST
EN SENS CONTRAIRE
Q
E
S SIEBAUSBAU
A
V
DN
KUGELSCHALTUNG: CrNi-STAHL
OK
U
AUF WUNSCH, ON REQUEST, SUR DEMANDE AUF ANFRAGE, ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER HÖHERE BETRIEBSDRÜCKE
DIFFERENCE PRESSURE INDICATOR HIGHER WORKING PRESSURES
INDICATEUR DE DIFFERÉNCE DE PRESSION PRESSIONS DE SERVICE ÉLEVÉES
S
BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
WITH RING-ELEMENTS FLOW IN OPPOSITE DIRECTION
AVEC DES PANIERS A ANNEAUX LE PASSAGE EST EN SENS CONTRAIRE
Q
N1/N2 D'APRES DIN2501 OU ASME B16.5 300 lbs sq.in.
H
PERCÉE SUIVANT ETAGE DE PRESSION
E
N1 N7 HEIZUNGSEINTRITT N8 HEIZUNGSAUSTRITT
L HEATINGINLET HEATINGOUTLET
ENTRÉE DE CHAUFFAGE SORTIE DU CHAUFFAGE
N8 BETRIEBSÜBERDRUCK HEIZRAUM 14 BAR BEI 200°C
O21.3x2.9
110
210 WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
T
POS.2
POS.1 VIDANGE
qU
S SIEBAUSBAU
RE DISMOUNTING THE FILTER ELEMENT
DÈMONTAGE DU PANIER
P
DN
SPHEROLITIQUE OU ACIER AUSTENITIQUE
OK
GEHÄUSE AUS C-STAHL GESCHWEISST
HOUSING WELDED OF CARBON STEEL
CORPS EN ACIER AU CARBONE SOUDÉ
POS.1 DRUCKAUSGLEICH SCHWEISSTOLERANZEN EN ISO 13920-CF
EQUALIZATION OF PRESSURE TOLERANCE EN ISO 13920-CF
EQUILIBRAGE DE PRESSION TOLÉRANCE EN ISO 13920-CF
AUF WUNSCH, ON REQUEST, SUR DEMANDE AUF ANFRAGE, ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER HÖHERE BETRIEBSDRÜCKE
DIFFERENCE PRESSURE INDICATOR HIGHER WORKING PRESSURES
INDICATEUR DE DIFFERÉNCE DE PRESSION PRESSIONS DE SERVICE ÉLEVÉES
N1 FILTEREINTRITT N2 FILTERAUSTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
OB POS.3
N2 BEI RINGSIEBEN DURCHFLUSS ENTGEGENGESETZT
WITH RING-ELEMENTS FLOW IN OPPOSITE DIRECTION
S
AVEC DES PANIERS A ANNEAUX LE PASSAGE EST EN SENS CONTRAIRE
OG
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300lbs sq.in. DRILLED
ACC. TO PRESSURE CLASS
N1/N2 D'APRES DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
F
C
H
Q
DRAIN
T
RS DÉSAÉRATION
53 VIDANGE
POS.1 POS.2 S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
RE
DÈMONTAGE DU PANIER
DN
3
øB N1 N1 FILTEREINTRITT
FILTERINLET
S
ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
RS
Q
øG N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs. sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
F
C
H
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED
ACC. TO PRESSURE CLASS
N1/N2 D'APRES DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
SUIVANT ÉTAGE DE PRESSION
E
N2 RE ENTLÜFTUNG G1/4
L AIR ESCAPE
DÉSAÉRATION
RS
RS ENTLEERUNG
T
DN
SPHÉROLITIQUE OU ACIER AUSTÉNITIQUE
OK
U
Z
AUF WUNSCH, ON REQUEST, SUR DEMANDE AUF ANFRAGE, ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER HÖHERE BETRIEBSDRÜCKE
DIFFERENCE PRESSURE INDICATOR HIGHER WORKING PRESSURES
INDICATEUR DE DIFFERÉNCE DE PRESSION PRESSIONS DE SERVICE ÉLEVÉES
øB N1
S
N1 FILTEREINTRITT
FILTERINLET
ENTRÉE DE FILTRE
RS N2 FILTERAUSTRITT
Q
FILTEROUTLET
øG SORTIE DU FILTRE
F
C
H
N1/N2 NACH DIN2501 ODER ASME B16.5 300 lbs sq.in.
ENTSPRECHEND DER DRUCKSTUFE GEBOHRT
N1/N2 ACC. TO DIN2501 OR ASME B16.5 300 lbs sq.in. DRILLED
ACC. TO PRESSURE CLASS
N1/N2 D'APRES DIN2501 OU ASME B16.5 300 lbs sq.in. PERCÉE
E
DÉSAÉRATION
POS.1 POS.2
RS ENTLEERUNG
DRAIN
RE VIDANGE
S SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
P
DÈMONTAGE DU PANIER
A
V
KUGELSCHALTUNG: CrNi-STAHL
BALL COCK VALVE: STAINLESS STEEL
3
AUF WUNSCH, ON REQUEST, SUR DEMANDE AUF ANFRAGE , ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER HÖHERE BETRIEBSDRÜCKE
DIFFERENCE PRESSURE INDICATOR HIGHER WORKING PRESSURES
INDICATEUR DE DIFFERÉNCE DE PRESSION PRESSIONS DE SERVICE ÉLEVÉES
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
DRAIN
F
VIDANGE
S SIEBAUSBAU
DISMOUNTING OF THE FILTERELEMENT
DÉMONTAGE DU PANIER
H
V
BY MULTIMANTLE-ELEMENT
øG POUR LES PANIERS À MANTEAUX
E
V SCHALTUNGSAUSBAU
N1 DISMOUNTING OF THE REVERSING DEVICE
L DÉMONTAGE DU DISPOSITIF DE COMMUTATION
X = A + HÖHE DER GEWÜNSCHTEN ANSCHLUSSFLANSCHE
A + HEIGHT OF THE CONNECTING FLANGES
A + HAUTEUR DES BRIDES DESIREES
GEHÄUSE AUS C-STAHL GESCHWEISST
HOUSING WELDED OF CARBON STEEL
RS CORPS EN ACIER AU CARBONE SOUDÉ
SCHWEISSTOLERANZEN EN ISO 13920-CF
T
DN POS.2 DIFFERENZDRUCKANZEIGER
DIFFERENCEPRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
ØZ
HÖHERE BETRIEBSDRÜCKE
HIGHER WORKING PRESSURES
PRESSIONS DE SERVICE ÉLEVÉES
X
A
O
0
R30
ANORDNUNG DER FLANSCHE
DISPOSITION OF FLANGES
K
TYP øG Q GR. DN
BESTELLBEISPIEL
ORDERING EXAMPLE 2.62.9 420 750 25 250
EXEMPLE DE COMMANDE
PN/ GEW. VOL.
øG Q GR. DN 120°C A B C E F H K L S V P qU O OZ T RS KG L
355 750 20 200 10 220 440 1241 1110 420 1381 340 515 1130 355 1175 110 560 23 20 G1 550 2x115
355 750 25 250 10 275 440 1241 1130 580 1381 380 580 1130 460 1290 120 560 23 20 G1 860 2x115
420 750 20 200 10 220 510 1255 1150 420 1400 340 515 1160 355 1310 110 560 23 20 G1 680 2x160
420 750 25 250 10 275 510 1255 1150 580 1400 380 580 1160 460 1425 120 560 23 20 G1 910 2x160
420 1000 25 250 10 275 510 1605 1445 580 1750 380 580 1500 460 1425 120 560 23 20 G1 961 2x204
520 1000 30 300 10 355 610 1610 1445 810 1755 440 735 1510 530 1770 120 560 23 20 G1 1380 2x325
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
N1 FILTEREINTRITT
FILTERINLET FILTEROUTLET
ENTRÉE DE FILTRE SORTIE DU FILTRE
F
DÉSAÈRATION
RS ENTLEERUNG
DRAIN
VIDANGE
H
S SIEBAUSBAU
V
DISMOUNTING OF THE FILTER ELEMENT
øG DÉMONTAGE DU PANIER
E
S=Q BEI MANTELSIEB
N1 BY MULTIMANTLE-ELEMENT
L POUR LES PANIERS A MANTEAUX
O21,3x2,9
V SCHALTUNGSAUSBAU
DISMOUNTING OF THE REVERSING DEVICE
N8 DEMONTAGE DU DISPOSITIF DE COMMUTATION
X = A + HÖHE DER GEWÜNSCHTEN ANSCHLUSSFLANSCHE
RS A + HEIGHT OF THE CONNECTING FLANGES
110
215
HEATINGINLET HEATINGOUTLET
RS, N7 UND N8 90° VERSETZT GEZEICHNET SORTIE DU CHAUFFAGE
RS, N7 AND N8 SHOWN 90° ROTATED ENTRÉE DE CHAUFFAGE
SCHALTSTELLUNGSANZEIGE RS, N7, N8 90° DEPLACÉ BETRIEBSÜBERDRUCK HEIZRAUM 14 BAR BEI 200°C
INDICATOR FOR SWITCH POSITION
INDICATEUR POUR POSITION DE MANOEUVRE WORKING PRESSURE HEATING COMPARTMENT 14 BAR AT 200°C
PRESSION DE SERVICE CHAMBRE DE CHAUFFAGE 14 BAR À 200°C
DN POS.1 DRUCKAUSGLEICH
EQUALIZATION OF PRESSURE
ÉQUILIBRAGE DE PRESSION
ØZ
0
R30
K
N1 FILTEREINTRITT
FILTERINLET
N2 ENTRÉE DE FILTRE
N2 FILTERAUSTRITT
FILTEROUTLET
SORTIE DU FILTRE
BEI RINGSIEBEN DURCHFLUSSENTGEGENGESETZT
WITH RINGELEMENTS FLOW IN OPOSITE DIRECTION
AVEC DES PANIERS À CORBEILLE LE PASSAGE EST EN SENS CONTRAIRE
FILTERELEMENT NUR RING- ODER MANTELSIEB
F
FILTERELEMENT ONLY RING- OR MULTIMANTLE ELEMENT
ELEMENT FILTRANT UNIQUEMENT PANIER À ANNEAUX OU À MANTEAUX
RE ENTLÜFTUNG G1/4
AIR ESCAPE
C
DÉSAÉRATION
H
RS ENTLEERUNG
V
DRAIN
øG VIDANGE
E
S SIEBAUSBAU
N1 DISMOUNTING OF THE FILTERELEMENT
L DÉMONTAGE DU PANIER
S=Q BEI MANTELSIEB
SCHALTSTERN BY MULTIMANTLE-ELEMENT
SWITCH-STAR POUR LES PANIERS À MANTEAUX
ETOILE DE MANOEUVRE
V SCHALTUNGSAUSBAU
215 DISMOUNTING OF THE REVERSING DEVICE
DÉMONTAGE DU DISPOSITIF DE COMMUTATION
RS X = A + HÖHE DER GEWÜNSCHTEN ANSCHLUSSFLANSCHE
T
EQUALIZATION OF PRESSURE
ÉQUILIBRAGE DE PRESSION
AUF WUNSCH, ON REQUEST, SUR DEMANDE
POS.2 DIFFERENZDRUCKANZEIGER
X
DIFFERENCEPRESSURE INDICATOR
A
HÖHERE BETRIEBSDRÜCKE
0
R30 HIGHER WORKING PRESSURES
PRESSIONS DE SERVICE ÉLEVÉES
K
RE ENTLÜFTUNG G1/4
AIR ESCAPE
DÉSAÉRATION
RS ENTLEERUNG
DRAIN
F
VIDANGE
S SIEBAUSBAU
C
V
BY MULTIMANTLE-ELEMENT
øG POUR LES PANIERS À MANTEAUX
E
V SCHALTUNGSAUSBAU
N1 DISMOUNTING OF THE REVERSING DEVICE
L DÉMONTAGE DU DISPOSITIF DE COMMUTATION
X = A + HÖHE DER GEWÜNSCHTEN ANSCHLUSSFLANSCHE
A + HEIGHT OF THE CONNECTING FLANGES
A + HAUTEUR DES BRIDES DESIREES
GEHÄUSE AUS CrNi-STAHL GESCHWEISST
HOUSING WELDED OF STAINLESS STEEL
RS CORPS EN ACIER AU INOX SOUDÉ
SCHWEISSTOLERANZEN EN ISO 13920-CF
T
DN POS.2 DIFFERENZDRUCKANZEIGER
DIFFERENCEPRESSURE INDICATOR
INDICATEUR DE DIFFERÉNCE DE PRESSION
ØZ
HÖHERE BETRIEBSDRÜCKE
HIGHER WORKING PRESSURES
PRESSIONS DE SERVICE ÉLEVÉES
X
A
O
0
R30
ANORDNUNG DER FLANSCHE
K
DISPOSITION OF FLANGES
DISPOSITION DES BRIDES
TYP2.52.9 TYP2.52.9-GÜ
qU POS.2
P -10
TYP øG Q GR. DN
BESTELLBEISPIEL 2.52.9 420 750 25 250
ORDERING EXAMPLE
EXEMPLE DE COMMANDE
PN/ GEW. VOL.
øG Q GR. DN 120°C A B C E F H K L S V P qU O OZ T RS KG L
355 750 20 200 10 220 440 1241 1110 420 1381 340 515 1130 355 1175 110 560 23 20 G1 550 2x115
355 750 25 250 10 275 440 1241 1130 580 1381 380 580 1130 460 1290 120 560 23 20 G1 860 2x115
420 750 20 200 10 220 510 1255 1150 420 1400 340 515 1160 355 1310 110 560 23 20 G1 680 2x160
420 750 25 250 10 275 510 1255 1150 580 1400 380 580 1160 460 1425 120 560 23 20 G1 910 2x160
420 1000 25 250 10 275 510 1605 1445 580 1750 380 580 1500 460 1425 120 560 23 20 G1 961 2x204
520 1000 30 300 10 355 610 1610 1445 810 1755 440 735 1510 530 1770 120 560 23 20 G1 1380 2x325
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
10.10.2002 PC 134-00
S a f e t y n e e d s q u a l i t y.
bipolar,
continuous,
process-optimized
THE SOLUTION
Filter candle open at both ends
BOLL SELFCLEAN types 6.18 and 6.19 use cylindrical filter candles open
at both ends with dynamic throttling at the top.
The fluid to be filtered flows via the two Simultaneously the pressure gradient that candles, because the effective back-
ends into the inside of the candles. In this arises permits a smaller quantity of fluid flushing prevents the candles beco-
way the particles of contamination to be to flow in reverse-flow from above ming progressively blocked. Saving
filtered out are retained over the whole through the filter candle. The rotating both labour and spare parts costs.
length of the inside of the candles so that throttle with PTFE covering plates locates • The way in which solids are separated
the full filtering area is uniformly at the upper end of the filter candles for is significantly more reliable than with
used. deliberate cross-flow backflushing and expanding disc elements, because
distribution of the backflushing energy there is a danger that particles of conta-
When the contamination deposited on over the full length of the candle. The mination will stick in between the
the inside of the candle reaches a level at combination of axial-flow and cross-flow expanding discs . At the point of
which cleaning of the filter becomes produces an optimal backflushing effect changeover from backflushing to fil-
necessary, the backflushing process is with uniform cleaning along the full tration, these trapped particles can be
initiated automatically. A geared motor length of the candle. released and the defined degree of
sets the cleaning device in action. A filtering will no longer be achieved.
covering arm moves over the upper, Thanks to this bipolar functional principle • In contrast to conical and expanding
open end of the filter candle and closes with cylindrical filter candles open at both disc filter elements, BOLL candles can
it. At the same time the flushing arm at ends, the BOLL 6.18 and 6.19 filters pos- be supplied with longitudinal wedge
the lower end is turned and the sludge sess several advantages over filters with wires . This produces superior
release valve is opened. In this way a conical or expanding disc filter elements: cleaning results particularly with
high axial flow is established in the filter • They have to be replaced less frequen- fibrous contaminants.
candle. tly than conical and cylindrical
2
Filter candles open at both ends –
the bipolar functional principle
Filtration phase Backflush phase Flushing speed * with candle open Wedge wire candle
at both ends with throttle at top
Longitudinal wedge
candle
Backflushing phase
*MET Motoren- and Energietechnik GmbH, Rostock, Prof. Dr.-Ing.habil. S.Bludszuweit, Dipl.-Ing. M. Britsch and Dipl.-Ing. Claudia Escher, 1996/1998. S a f e t y n e e d s q u a l i t y. 3
THE CONCEPT
Designed from experience to be flexible
and application oriented
The precision manufactured BOLL into the upper part of the housing and
SELFCLEAN type 6.18 and 6.19 automa- from there downwards into the open end
tic filters are robustly constructed of a of the filter elements . The other half
material suitable for the specific applica- flows from the bottom upwards into the
tion, cast iron, carbon steel or stainless filter element . The filtered fluid passes
steel. Based on years of experience in this to the outside via the gaps in the cand-
field, the design is both, simple for ease le. Gap widths down to 50 microns are
of maintenance and effective for preci- possible. During the backflushing cycle,
se filtration levels. Available in a range of the candles are cleaned one after the other
sizes, connection flanges up to 9000 m3/h. without the filtration process being inter-
The filter elements and all internal parts, rupted. The injection flow generated
connecting tubes and unions are of chro- prevents blocking in the upper part of the
me-nickel-molybdenum steel (Cr.Ni.Mo. filter element. Backflushing can be carried
steel). The sole moving parts are the flus- out with the filtrate fluid (type 6.18) or an
hing arm and the covering arm . The external medium (type 6.19), selection
plastic bushes of these are self-adjusting. being based on the plant operating
The sliding bearing and the flushing pressure. Steam or water at high pressure
bushes of plastic are sealed against conta- is used as the external medium at opera-
mination. ting pressures of less than 2 bar or when
In filtering mode the fluid to be filtered sticky contaminants are present. Back-
reaches the lower part of the housing via flushing is initiated as a function of the
the inlet flange . A part flow of approx. differential in pressure
between the
50% of the unfiltered medium is led via inlet and outlet or at programable inter-
the central riser pipe in the filter insert vals.
T H E A D VA N TA G E S
Economical and ecologically
trend-setting
The economical optimum can be ex- BOLL filters protect high-value capital
pressed as “as much as possible” for “as equipment from premature wear by filte-
little as necessary”. For those making ring the dirt out of the contaminated fluid
capital investment decisions, optimum in a consistent manner and feeding the
expenditure can be expressed as either, cleaned fluid back into the process again.
“as little as possible” or, “as much as is ne- They contribute to securing the opera-
cessary”. The more capital-intensive the tional reliability of the plant in a conti-
plant and machinery, the greater the ne- nuous and long-term manner. This saves
cessity for a one-off expenditure on a high resources while sparing the environment
quality filtering system. In existing plant and reducing costs. In this way BOLL
too, long-term economies can be made filters are the best insurance for both
by selecting effective and efficient filter product and process, providing the
systems. The installation of proper filtra- opportunity for reinvestment, growth
tion is the mark of a progressive business. and profit. Backflushing
4
Control and monitoring
Part of the standard scope of delivery of
the backflushing filter is the electronic
control type 2100 with the following
Flow rates of water
V = 2 m/s
V = 3 m/s
V = 4 m/s
9000
8000 DN 800
7000 DN 700
6000
DN 600
5000
4000 DN 500
3000
DN 400
2000
DN 300
1000 DN 250
DN 200
500
400
300
DN 150
200
DN 100
150
100
Flow rates in m 3/h
50
40 DN 50
30
20
0,05 0,1 0,2 0,3 0,4 0,5
Pressure loss in bar
S a f e t y n e e d s q u a l i t y. 5
THE COMPLETE OFFER
Quality thanks to specialization
At BOLL & KIRCH, we concentrate Economic manufacturing on CNC and
DNC controlled machine tools.
exclusively on the design and fabricati-
on of filters for fluids. BOLLFILTER
products are the result of our own rese-
arch and development and many are
protected by patent. Customers can take
advantage of our specialist know-how
by involving BOLL & KIRCH engineers
in their projects right from the earliest Our various stores and logistics
stages. The combination of expertise on systems underpin speedy and efficient
both sides in a simultaneous enginee- production.
T H E D E TA I L S
In summary form
SELFCLEAN Type 6.18 SELFCLEAN Type 6.19
backflushing with filtrate fluid backflushing with external medium
Areas of application filtration of water and emulsions filtration of water and emulsions
Max. flow rate 9000 m /h3
2500 m 3/h
Max. filter fineness 50 microns 50 microns
Nominal diameter of connection flange 50 - 900 mm 50 - 400 mm
Operating pressures from 0 to 16 bar (higher pressures on request) from 0 to 16 bar (higher pressures on request)
Housing material gray cast iron casting or welded steel gray cast iron or welded steel
Backflushing medium filtrate fluid external medium
Backflushing control as function of time or differential pressure as function of time or differential pressure
Filter candle type cylindrical candles open at both ends cylindrical candles open at both ends
Candle types lateral or longitudinal wedge or wire mesh lateral or longitudinal wedge or wire mesh
Optional accessories dirt pump in the sludge removal line dirt pump in the sludge removal line
booster pump
6
Examples of areas of application for BOLL Automatic Filters
S E L F C L E A N TYPE 6.18 and TYPE 6.19:
3. Paper industry
• Process water
• Washing (injection) water
for the paper machine
4. Offshore industry
• Injection water for oil rigs
6. Mining
• Process water
SELFCLEAN
• Cooling water
TYPE 6.19
7. Automobile industry
• Process water, cooling water
for welding shops, air-conditioning
systems and power stations
• Fire extinguishing water
8. Steelworks
• Cooling water for rolling mills,
skin-pass stands, heat treatment
systems
• Quenching water for continuous
casting lines
9. Artificial snow
• Operating water for
snow-making machines
S a f e t y n e e d s q u a l i t y. 7
BOLL Automatic Filters are characterized by the following particularly advantageous properties:
dimensional
filtertype connection material remarks
drwg.
Z100879 KV-sheet 124 quantity of back-flushing for type 6.23 and 6.24
Z100882 KV-sheet 125 pressure drop during back-flushing
Z100337 6.23 32-50 nodular cast iron without heating and bypass
Z100344 6.23.1 32-50 nodular cast iron without heating; with bypass
Z100348 6.24 32-50 nodular cast iron with heating; without bypass
Z100379 6.24.4 32-50 nodular cast iron with heating; with heated bypass filter
Z100814 6.24.2 32-50 nodular cast iron with heating; bypass as automatic filter
Z100816 6.24.7 32-50 nodular cast iron with heating; bypass as semi-automatic filter
Z100817 6.27 32-50 nodular cast iron heated semi-automatic filter; without bypass
10.10.2002 PC 134-00
Z100879
TYP6.23/6.24
01.10.88
VISKOSITAET 30 CST
VISCOSITY
L/S
1.1
1.0
9
0.9 ELø
SS
DRO LE
0.8 50 TT
40+ THRO
DN ROSSEL
ø6
0.7 50 D
DN 40+
QUANTITY OF BACK FLUSHING
E TL
THROT
0.6 ø6
RUECKSPUELMENGE
SEL
OS
0.5 DR TLE
32 ROT
DN TH EL ø4
32 DROSS
0.4 DN ROTT
LE
TH
0.3
0.2
0.1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 BAR
BETRIEBSDRUCK
OPERATING PRESSURE
EFFEKTIVE SPUELZEIT
FLUSHING TIME
DN 32 - 1.2 SEC
DN 40 - 1.5 SEC
DN 50 - 2.3 SEC
16
15
DRUCK-FILTERAUSTRITT WAEHREND DER RUECKSPUELUNG (BAR)
14
13
12
11 4
EL ø ø6
PRESSURE AT FILTER OUTLET DURING BACK FLUSHING
10 S L
ROS SSE
D O
9 N32 0 DR
D 0+5
4
8 DN
7
6
5
ø9
4 SEL
S 6
DRO EL ø
3 +5
0 SS
N40 DRO
2 D 32
DN
1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
DRUCK-FILTERAUSTRITT VOR RUECKSPUELUNG (BAR)
PRESSURE AT FILTER OUTLET FOR BACK FLUSHING
SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DEMONTAGE DU PANIER
H
e
k
E
AUSTRITT
OUTLET
D
SORTIE
F
D
EINTRITT
INLET
ENTREE
øG øU
SCHLAMMABLASS
MUD DRAIN
VIDANGE DE BOUES
Z B
BETRIEBSDRUCK FILTERRAUM AT
WORKING PRESS.FILTER CHAMBER 2-16 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR
JOINTS ET LA BOULONNERIE
A
GEHAEUSE GEGOSSEN
HOUSING CASTED GGG
CORPS MOULE
GEWICHT INHALT
DN A B C øD E F øG H L S øU Z a e h k KG L
32 110 90 315 44 90 85 139 517 184 250 29 220 75 M10x13 135 45 22 2.7
40 140 120 325 50 60 120 200 535 245 250 29 250 75 M10x13 135 50 35 6
50 140 120 425 62 110 120 200 680 245 300 29 250 75 M10x13 135 50 37 7.5
SUBJECT TO ALTERATIONS! AENDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES!
AUSTRITT
OUTLET
STEUERLUFTANSCHLUSS ø6x1 SORTIE
SIEBAUSBAU CONTROL AIR CONNECTION SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT CONNECTION D'AIR DE COMMANDE DISMOUNTING THE FILTER ELEMENT
DEMONTAGE DU PANIER
DEMONTAGE DU PANIER
T
S
H
E1
D
F
D
C
C1
EINTRITT
INLET
ENTREE
SCHLAMMABLASS øU ENTLEERUNG G1
MUD DRAIN øG øG1 MUD DRAIN
VIDANGE DE BOUES VIDANGE DE BOUES
L
M N
"X"
B1
B
ANSICHT "X"
VIEW "X"
A
VUE "X"
Z
e
e a
k
k
h
h
GEWICHT INHALT
DN A B B1 C C1 øD E E1 F øG øG1 H L M N S T øU a e h k Z KG L
32 80 90 90 315 315 44 133 133 85 139 139 517 485 171 171 250 150 29 75 M10x13 135 87 220 46 5.4
40 100 120 90 325 365 50 120 170 120 200 136 530 590 222 192 250 230 29 75 M10x13 135 70 250 58 9.6
50 100 120 90 425 365 62 170 170 120 200 136 680 590 222 192 300 230 29 75 M10x13 135 120 250 68 11
SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT
DEMONTAGE DU PANIER
H
e S
k
AUSTRITT
E
OUTLET
SORTIE
D
F
D
EINTRITT
INLET
ENTREE
R
R
~P
K
AUSTRITT HEIZANSCHLUSS
SORTIE RACC.RECHAUFFAGE
OUTLET HEATING CONNECTION
EINTRITT HEIZANSCHLUSS
øG INLET HEATING CONNECTION øU
ENTREE RACC.RECHAUFFAGE
Q O
SCHLAMMABLASS
MUD DRAIN
VIDANGE DE BOUES BETRIEBSDRUCK FILTERRAUM AT
WORKING PRESS.FILTER CHAMBER 2-16 BAR BEI 200°C
Z B PRESS.DE SERVICE CHAMBRE FILT. PAR
HEIZRAUM AT
HEATING CHAMBER 14 BAR BEI 200°C
CHAMBRE DE CHAUFFAGE PAR
GEHAEUSE GEGOSSEN
A
INHALT GEWICHT
DN A B C øD E F øG H K L O ~P Q R S øU Z a e h k L KG
32 110 90 315 44 90 85 139 517 33 184 10 65 80 21.3x3.2 250 29 220 75 M10x13 135 45 2.7 25
40 140 120 325 50 60 120 200 530 33 245 10 50 110 21.3x3.2 250 29 250 75 M10x13 135 50 6 41
50 140 120 425 62 110 120 200 680 33 245 10 100 110 21.3x3.2 300 29 250 75 M10x13 135 50 7.5 43
AENDERUNGEN VORBEHALTEN!
SUBJECT TO ALTERATIONS! MODIFICATIONS RESERVEES!
AUTOMATIC FILTER DRUCKFILTERAUTOMAT FILTRE A PRESSION
AUTOMATIQUE
TYP6.24
Z100379
TYP6.24.4
04.04.97
AUSTRITT
SIEBAUSBAU OUTLET
DISMOUNTING THE SORTIE
FILTER ELEMENT STEUERLUFTANSCHLUSS ø6x1
DEMONTAGE DU PANIER CONTROL AIR CONNECTION SIEBAUSBAU
CONNECTION D'AIR DE COMMANDE DISMOUNTING THE FILTER ELEMENT
DEMONTAGE DU PANIER
T
S
H
E1
D
ANSICHT "Y"
VIEW "Y"
VUE "Y"
F
D
C
C1
P
P
R R
"Y"
EINTRITT
INLET J O
Q J ENTREE
K
øU ENTLEERUNG G1
SCHLAMMABLASS øG MUD DRAIN øG1
MUD DRAIN
VIDANGE DE BOUES
AUSTRITT-HEIZANSCHLUSS
VIDANGE DE BOUES OUTLET HEATING CONNECTION
L SORTIE RACCORDEMENT
RECHAUFFAGE
M N
"X"
EINTRITT-HEIZANSCHLUSS
INLET HEATING CONNECTION
B1
ENTREE RACCORDEMENT
B
RECHAUFFAGE
ANSICHT "X"
VIEW "X"
VUE "X"
A
e
Z
e a
k
k
h
h
SIEBAUSBAU
DISMOUNTING THE
FILTER ELEMENT STEUERLUFTANSCHLUSS ø6x1 STEUERLUFTANSCHLUSS ø6x1
DEMONTAGE DU PANIER CONTROL AIR CONNECTION CONTROL AIR CONNECTION
CONNECTION D'AIR DE COMMANDE CONNECTION D'AIR DE COMMANDE
AUSTRITT
OUTLET
SORTIE GEHAEUSE GEGOSSEN
HOUSING CASTED GGG
CORPS MOULE
S
GEGENFLANSCHE, DICHTUNGEN
UND SCHRAUBEN GEHOEREN
ZUM LIEFERUMFANG
COUNTER FLANGES, GASKETS AND BOLTS
E
BELONG TO DELIVERY
FRONT PARTIE DE LA FORNITURE
D
CONTRE BRIDES, JOINTS
ET LA BOULONNERIE
ANSICHT "Y"
VIEW "Y"
F
VUE "Y"
D
C
H
R R
"Y"
EINTRITT
INLET
Q J ENTREE
K
øU SCHLAMMABLASS
øG MUD DRAIN
VIDANGE DE BOUES
AUSTRITT-HEIZANSCHLUSS
OUTLET HEATING CONNECTION
L SORTIE RACCORDEMENT
RECHAUFFAGE
M N
"X"
EINTRITT-HEIZANSCHLUSS
INLET HEATING CONNECTION
ENTREE RACCORDEMENT
B
RECHAUFFAGE
A
ANSICHT "X"
VIEW "X"
VUE "X"
Z
e
e a
k
k
h
h
e
BETRIEBSDRUCK FILTERRAUM AT
WORKING PRESS.FILTER CHAMBER 2-16 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR
e
HEIZRAUM AT TOLERANZEN
HEATING CHAMBER 14 BAR BEI 200°C TOLERANCE DIN7168 "SG"
CHAMBRE DE CHAUFFAGE PAR TOLERANCE
GEWICHT INHALT
DN A B C øD E F øG H J K L M N P Q R S øU a e h k Z KG L
32 80 90 315 44 133 85 139 517 10 33 485 171 171 120 80 21.3x3.2 250 29 75 M10x13 135 87 220 53 5.4
40 100 120 325 50 120 120 200 530 10 33 650 222 222 155 110 21.3x3.2 250 29 75 M10x13 135 70 250 69 12
50 100 120 425 62 170 120 200 680 10 33 650 222 222 155 110 21.3x3.2 300 29 75 M10x13 135 120 250 79 15
FILTER COMBINATION
FILTERKOMBINATION COMBINAISON DES FILTRES
TYP 6.24.2
Z100816
TYP6.24.7
07.04.97
ANSICHT "Y"
F
VIEW "Y"
VUE "Y"
D
C
H
R R
"Y"
EINTRITT
INLET
Q J ENTREE
K
øU SCHLAMMABLASS
øG MUD DRAIN
VIDANGE DE BOUES
AUSTRITT-HEIZANSCHLUSS
OUTLET HEATING CONNECTION
L SORTIE RACCORDEMENT
RECHAUFFAGE
M N
"X"
EINTRITT-HEIZANSCHLUSS
INLET HEATING CONNECTION
ENTREE RACCORDEMENT
B
RECHAUFFAGE
ANSICHT "X"
A
VIEW "X"
VUE "X"
Z
e
e a
k
k
h
h
e
BETRIEBSDRUCK FILTERRAUM AT
WORKING PRESS.FILTER CHAMBER 2-16 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR
e
HEIZRAUM AT TOLERANZEN
HEATING CHAMBER 14 BAR BEI 200°C TOLERANCE DIN7168 "SG"
CHAMBRE DE CHAUFFAGE PAR TOLERANCE
GEWICHT INHALT
DN A B C øD E F øG H J K L M N P Q R S øU a e h k Z KG L
32 80 90 315 44 133 85 139 517 10 33 485 171 171 120 80 21.3x3.2 250 29 75 M10x13 135 87 220 51 5.4
40 100 120 325 50 120 120 200 530 10 33 650 222 222 155 110 21.3x3.2 250 29 75 M10x13 135 70 250 67 12
50 100 120 425 62 170 120 200 680 10 33 650 222 222 155 110 21.3x3.2 300 29 75 M10x13 135 120 250 77 15
SIEBAUSBAU
DISMOUNTING THE
FILTER ELEMENT
DEMONTAGE DU PANIER
H
e
k
AUSTRITT
E
OUTLET
SORTIE
D
F
D
EINTRITT
INLET
ENTREE
R
~P
K
AUSTRITT HEIZANSCHLUSS
OUTLET HEATING CONNECTION
SORTIE RACC.RECHAUFFAGE
EINTRITT HEIZANSCHLUSS
øG INLET HEATING CONNECTION øU
ENTREE RACC.RECHAUFFAGE
Q O
SCHLAMMABLASS
MUD DRAIN
VIDANGE DE BOUES STEUERLUFTANSCHLUSS ø6x1
CONTROL AIR CONNECTION
Z B CONNECTION D'AIR DE COMMANDE
AT
HEIZRAUM
HEATING CHAMBER 14 BAR BEI 200°C
CHAMBRE DE CHAUFFAGE PAR
BELONG TO DELIVERY
FRONT PARTIE DE LA FORNITURE CONTRE BRIDE
S
JOINTS ET LABOULONNERIE
L
A
GEHAEUSE GEGOSSEN
HOUSING CASTED GGG
CORPS MOULE
AT TOLERANZEN
BETRIEBSDRUCK FILTERRAUM TOLERANCE DIN7168 "SG"
WORKING PRESS.FILTER CHAMBER 2-16 BAR BEI 200°C TOLERANCE
PRESS.DE SERVICE CHAMBRE FILT. PAR
INHALT GEWICHT
DN A B C øD E F øG H K L O ~P Q R S øU Z a e h k L KG
32 110 90 315 44 90 85 139 517 33 184 10 65 80 21.3x3.2 250 29 295 75 M10x13 135 45 2.7 25
40 140 120 325 50 60 120 200 530 33 245 10 50 110 21.3x3.2 250 29 330 75 M10x13 135 50 6 41
50 140 120 425 62 110 120 200 680 33 245 10 100 110 21.3x3.2 300 29 330 75 M10x13 135 50 7.5 43
The BOLL automatic filter SELFCLEAN TYPE 6.60/6.61 is ter chamber with cleaned filter candles is always held in
designed precisely to fulfil the task. The filter housing is reserve, whilst the other filter chambers are simultane-
equipped with several filter chambers. Each filter cham- ously providing the filtration function. As the amount of
ber contains a filter insert made-up of a number of filter contamination increases, the differential pressure indica-
candles, each candle is made from a spiral-wound sup- tor initiates the back-flushing phase via the electronic
port structure over which high-grade filter mesh is drawn. control. Compressed air is used for cleaning the filter
Large filter surfaces with high “free passage” areas gua- candles. The system pressure remains constant and the
rantee a low pressure differential. As each filter chamber flushing quantities produced are very low. Additionally,
becomes dirt-loaded, it is isolated from flow and regene- the compact construction means little space is required to
rated by back-flushing, each in sequence with no inter- install the filter. This filter series can be provided with a
ruption to operation. During the filtration process one fil- sludge treatment unit on request.
During the filtration operation the liquid to be filtered en- nism until the inlet and outlet to one contaminated cham-
ters through the inlet into the change-over housing, on ber is blocked, simultaneously releasing the reserve
which the filter chambers with the filter candles are chamber. Now the sludge discharge valve opens and
mounted. The rotary selector mechanism is located in the blocked chamber is depressurised. At the same time
the centre of the housing. The contaminated liquid is fed the filter-stored compressed air is explosively released
into the filter chambers and flows through the filter can- from the upper hollow space of the selector mechanism
dles from outside to inside. The solids to be filtered out are and discharges the liquid from the selector mechanism
retained on the filter mesh. Cleaned liquid passes through and the closed-off filter chamber. In parallel with the
the inside of the candle to the filter outlet in the lower pressure release the flushing valve
opens. The com-
section of the housing. pressed air from the air reservoir accelerates the clean
During this process one filter chamber is held in reserve liquid in the filter chamber and pushes it in the reversed
with cleaned filter candles, separate from the filtration flow through the filter candles. Due to the pressure burst,
process, the sludge discharge valve is closed and com- the dirt particles are flushed off the filter mesh and out of
pressed air is stored in the air reservoir. the filter housing through the opened sludge discharge
The growing layer of dirt on the filter mesh results in a valve .
pressure differential between the dirty side and the clean Compressed air then continues to flow for a short period,
side; self-cleaning of one filter chamber is automatically then the sludge discharge valve and flushing valve are
triggered once this differential reaches a predetermined again closed. The now clean but empty chamber is filled
value. The electric motor (or, in the case of the TYPE with clean liquid via a top-up bore in the selector me-
6.60 a pneumatic drive system) turns the selector mecha- chanism, to become the reserve chamber, ready to be
brought into use on next signal.
Filtration Backflushing
Filtration of the back-flushing liquid
T H E D E TA I L S
Data and Facts at a glance
SELFCLEAN TYPE 6.60 / 6.61 Multi-chamber automatic filter with compressed-air back-flushing
Range of application Lubricating oil, diesel oil, heavy fuel oil, cutting oil, emulsions, coolant, industrial wash liquids
Operating pressures up to 10 bar (higher pressures on request)
differential pressure resistance up to operating pressure
Operating temperature up to 150ºC
Housing material grey cast iron and ductile iron
Nominal width coupling flange DN 50 - DN 350
Max. flow rate 800 m3/h
Filtration fineness up to 10 microns absolute
Filter candle type Cylindrical screw-in candles with woven mesh
Cleaning method Sequential, reversed flow back-flushing , assisted by compressed air
Back-flushing control Differential pressure dependent or time-dependent
Technical data Type Size Number of chambers Total number Filtration area Weight of filter (kg)
Total In use of filter candles in use cm2 Empty Filled
BOLL & KIRCH concentrate exclusively on the design and The global presence of BOLL & KIRCH in all important in-
manufacture of liquid/solid separation filters. Most BOLL- dustrial centres guarantee to customers worldwide the
FILTERs are the result of our own research and develop- reliability and service that they expect of a supplier of
ment and are protected by patents. Customers can take technologically exacting filter systems, a service that in-
advantage of our knowledge by involving our technicians cludes dispatching BOLLFILTER genuine parts all over
and engineers in the early phases of their projects. Focus- the world within 24 hours.
sing the knowledge of both partners in simultaneous en-
gineering ensures a perfect result.
Commercial production on CNC and DNC Modern storage and logistics systems sup- BOLLFILTER genuine parts leave the cen-
controlled machine tools. port smooth and effective production. tral warehouse within 24 hours.
BOLL Automatic filters type 6.60/6.61 – the advantages include the following:
S
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
EIN-BZW. AUSTRITT
HEIZUNG ø22
IN RESPECT. OUTLET
HEATING ø22
ENTREE RESPECT. SORTIE
CHAUFFAGE ø22
L
DN
F
H
DN
U
E
h
R
T P SCHLAMMABLASS dn V D
D
MUD DRAIN
VENTILAUSBAU VIDANGE DE BOUES
W
DISMOUNTING OF THE VALVE
DEMONTAGE DE LA VANNE DRUCKLUFT MIN 4BAR
AIR PRESSURE N
PRESSION D'AIR
LUFTANSCHLUSS ø8x1
AIR CONNECTION
PRISE D'AIR
B
Z
M
Y
d
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXAUTION AU FOND
X
A
AT AT
BETRIEBSDRUCK FILTERRAUM HEIZRAUM
WORKING PRESS.FILTER CHAMBER max.16 BAR BEI 140°C HEATING CHAMBER 14 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR CHAMBRE DE CHAUFFAGE PAR
50
05 2 475 410 110 195 120 415 895 205 210 265 65 300 200 300 240 33 240 37 240 12 18 50 100 15
65
SUBJECT TO ALTERATIONS! AENDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES!
FULLY AUTOMATIC BACK VOLLAUTOMATISCHER RUECKSPUELFILTER FILTRE AUTOMATIQUE
FLUSHING FILTER TYP 6.60
Z32570
TYP6.60.1
12.07.02
ANSICHT X
VIEW X
VUE X
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
EINTRITT DN50
EIN- BZW. AUSTRITT HEIZUNG ø22 INLET
IN RESPECTIVELY OUTLET HEATING ø22 ENTREE
ENTREE RESPECT. SORTIE CHAUFFAGE ø22
"Z"
ANSICHT Z
VIEW Z DRUCKLUFT MIN. 4BAR
VUE Z AIR PRESSURE
PRESSION D'AIR
LUFTANSCHLUSS ø8x1
AIR CONNECTION
PRISE D'AIR
ANSICHT Y FREIMASSTOLERANZEN
VIEW Y TOLERANCE ISO 2768-m BODENBEFESTIGUNG
VUE Y TOLERANCE BOTTOM FASTENING
"Y" FIXAUTION AU FOND
ø12
"X"
GEGENFLANSCHE IM LIEFERUMFANG
COUNTER FLANGES INCLUDED
CONTRES BRIDES INCLUS
VENTILAUSBAU
DISMOUNTING OF THE VALVE
DN50 DEMONTAGE DE LA VANNE
FILTERKOMBINATION
FILTER COMBINATION
TYP 6.60.1 GR.05 COMBINAISON DE FILTRES
Z100292
TYP6.61
04.03.02
SIEBAUSBAU
DISMOUNTING THE SIEVE
S
DEMONTAGE DU PANIER
G
L
DN
F
H
SCHLAMMABLASS
MUD DRAIN
VIDANGE DE BOUES
DN
dn
E
b
R
c D a C
DRUCKLUFT MIN. 4 BAR
T P AIR PRESSURE C1
PRESSION D'AIR
VENTILAUSBAU LUFTANSCHLUSS ø8x1
DISMOUNTING OF THE VALVE AIR CONNECTION
DEMONTAGE DE LA VANNE PRISE D'AIR
X
M
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATION AU FOND
d
N
Z
Y
B
80 200
10 4 600 460 200 - 140 135 315 476 515 1110 200 200 250 95 300 200 270 55 270 105 165 225 18 15 50 38
100 215
150 310 - 345
15 7 680 690 170 165 375 476 605 1250 300 300 250 95 300 200 370 55 370 105 165 225 18 15 50 71
200 - 580 395
200 335 - 620
20 6 850 750 275 225 475 485 750 1420 400 400 350 125 300 250 500 75 500 165 165 240 27 25 100 150
250 - 645 690
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
AUSTRITT DN100
OUTLET
SORTIE
DRUCKLUFT MIN.4 BAR
AIR PRESSURE SIEBAUSBAU
PRESSION D'AIR DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
LUFTANSCHL.ø8X1
AIR CONNECTION
PRISE D'AIR
EINTRITT DN100
INLET
EIN-BZW.AUSTRITT ENTREE
HEIZUNG ø22
IN-RESPEC.OUTLET
HEATING ø22
ENTREE RESPEC.SORTIE
CHAUFFAGE ø22
EINTRITT ø21.3x3.2
AUSTRITT ø21.3x3.2 INLET
SCHLAMMABLASS OUTLET ENTREE
MUD DRAIN SORTIE
VIDANGE DE BOUES
DN50 ø 14
40
ø18
VENTILAUSBAU FREIMASSTOLERANZEN
DISMOUNTING OFTHE VALVE TOLERANCE ISO 2768-m
DEMONTAGE DE LA VANNE TOLERANCE
FILTER COMBINATION
FILTERKOMBINATION COMBINAISON DE FILTRES
TYP 6.61.1 GR.10
Z40831
TYP6.61.1 GR.15
22.02.02
SIEBAUSBAU
300
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
AUSTRITT DN150
680
OUTLET
SORTIE
EIN-BZW.AUSTRITT
HEIZUNG ø22
(NACH AUFTRAG)
IN- RESPEC.OUTLET
HEATING ø22
(ACCORDING TO ORDER)
ENTREE RESPEC.SORTIE
CHAUFFAGE ø22
(APRES COMMANDE)
DRUCKLUFT
MIN 4 BAR
AIR PRESSURE
PRESSION D'AIR
LUFTANSCHL.ø8x1
AIR CONNECTION
PRISE D'AIR
SCHLAMMABLASS DN50
MUD DRAIN
VIDANGE DE BOUES
VENTILAUSBAU
200
FILTERKOMBINATION
FILTER COMBINATION
TYP 6.61.1 GR.15 COMBINAISON DE FILTRES
S a f e t y n e e d s q u a l i t y.
The BOLL automatic filter SELFCLEAN TYPE 6.62 opti- an exhausted one. The point of exhaustion is determined
mally meets the requirements outlined. This is attained by through the pressure difference between dirty and clean
a filter design based on several chambers which may be side. Regeneration is extremely fast, thorough and easy on
separated from each other in which the functions of filte- the mesh, and is supported by compressed air. The system
ring and regeneration are performed separately. pressure is maintained at a constant level and the flushing
The filter housing contains four filter chambers, with each quantities are small.
chamber containing a filter candle. These operate as a sin- In addition, a heating chamber has been integrated in the
gle system whereby the filtering task is split internally bottom section of the housing. This chamber ensures that
among the four candles. This is done in such a way that the discharged clean fluid is maintained at the temperatu-
always one is paused so that it may regenerate whilst the re needed for its further use.
others continue to filter. Once the capacity of the working
filter candles is exhausted, the fresh filter candle replaces
SELFCLEAN TYPE 6.62 Multi-chamber automatic filter with compressed air back-flushing
Range of application heavy fuel oil, diesel oil, lubricating oil
Operating pressure 1 to 16 bar (higher pressures on request)
Differential pressure resistance up to operating pressure
Housing material ductile graphite iron (GGG)
Nominal width coupling flanges DN 40
Type of filter candle / mesh cylindrical screw-in candles with woven mesh
Cleaning method sequential, reversed flow back-flushing with compressed air support
Back-flushing control differential pressure dependent or time dependent
Technical data
Booster system (t max. 150 °C) Supply system (t max. 100 °C)
Mesh micron Flow rate m /h
3
Mesh micron Flow rate m3/h
50 5,5 50 2,5
34 5,5 34 2,5
25 2,2 25 1,0
10 1,0
BOLL & KIRCH focuses its activities exclusively on the The global presence of BOLL & KIRCH in all important in-
manufacture of liquid/solid separating filters. Many dustrial centres guarantees to customers world-wide the
BOLLFILTERS are the result of own research and deve- reliability and service they expect from a supplier of tech-
lopment activities and are protected by patents. Custo- nology-wise demanding filter systems. This includes
mers can take advantage of our know-how by involving dispatching of BOLLFILTER genuine parts from all over
our technicians and engineers during the early phases of the world within 24 hours.
their projects. Focussing the know-how of both partners
in simultaneous engineering ensures a perfect result.
Economic production on CNC and DNC Modern warehousing and logistics BOLLFILTER genuine parts leave the cen-
controlled machines. systems support speedy and effective tral warehouse within 24 hours.
production.
T H E A D VA N TA G E S
Economically and ecologically leading
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
S
L
LUFTANSCHLUSS ø8x1
H
AIR CONNECTION
PRISE D'AIR
EINTRITT DN
INLET
F
ENTREE
AUSTRITT DN
OUTLET
SORTIE
N
E
h
SCHLAMMABLASS dn b
MUD DRAIN M V
VIDANGE DE BOUES
EIN-BZW. AUSTRITT HEIZUNG ø22
A
IN RESPECTIVELY OUTLET HEATING ø22
ENTREE RESPECT. SORTIE CHAUFFAGE ø22
AT
BETRIEBSDRUCK FILTERRAUM
max.16 BAR BEI 160°C
WORKING PRESS.FILTER CHAMBER
PRESS.DE SERVICE CHAMBRE FILT. PAR
HEIZRAUM AT
B
FREIMASSTOLERANZEN
TOLERANCE DIN ISO 2768-m
TOLERANCE
C
GEGENFLANSCHE IM LIEFERUMFANG
COUNTER FLANGES INCLUDED
CONTRES BRIDES INCLUS
Z
Y
GEHAEUSE GEGOSSEN
HOUSING IN CAST IRON
CORPS MOULE
GEWICHT INHALT
GR. DN A B C D E F H L M N S U V W X Y Z b h d dn KG LTR
40
04 375 325 110 140 140 120 620 875 165 130 500 45 110 190 160 190 160 45 15 13.5 25 105 14
SIEBAUSBAU
DISMOUNTING THE SIEVE
L
DEMONTAGE DU PANIER
S1
EINTRITT DN
INLET
ENTREE
S2
H2
H1
F
E
N
U
U
b K
DRUCKLUFT MIN 4BAR M V
AIR PRESSURE
SCHLAMMABLASS dn "Y"
PRESSION D'AIR MUD DRAIN "X" AUSTRITT DN
LUFTANSCHLUSS ø8x1 VIDANGE DE BOUES
AIR CONNECTION OUTLET
PRISE D'AIR SORTIE A
"Y" Od
B
"X" Z
Y
R O P
BETRIEBSDRUCK FILTERRAUM AT HEIZRAUM AT
WORKING PRESS.FILTER CHAMBER max.16 BAR BEI 160°C HEATING CHAMBER 14 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR CHAMBRE DE CHAUFFAGE PAR
FREIMASSTOLERANZEN GEHAEUSE GEGOSSEN GEGENFLANSCHE IM LIEFERUMFANG
TOLERANCE DIN ISO 2768-m HOUSING IN CAST IRON COUNTER FLANGES INCLUDED
TOLERANCE CORPS MOULE CONTRES BRIDES INCLUS
GEWICHT INHALT
GR. DN A B E F G H1 H2 K L M N O P R S1 S2 U V W X Y Z b h d dn KG LTR
40
04 700 325 140 120 100 620 370 80 875 165 130 220 190 215 500 230 45 110 190 160 190 160 45 15 13.5 25 140 19
Z45559 6.60.07 50/65 nodular cast iron/AK size 05; with flushing oil treatment unit
Z45558 6.61.07 80-350 cast iron/AL with flushing oil treatment unit
Z32568 6.61.1 80/100 cast iron size 10, with bypass filter
Z40618 6.61.1 150/200 cast iron size 15, with bypass filter
Z40271 6.61.1 200/250 cast iron size 20, with bypass filter
Z40617 6.61.1 250/300 cast iron size 25, with bypass filter
Z33960 6.61.1.7 80/100 cast iron/AL size 10, with flushing oil treatment unit and bypass
Z40620 6.61.1.7 150/200 cast iron/AL size 15, with oil treatment unit and bypass
Z40272 6.61.1.7 200/250 cast iron/AL size 20, with flushing oil treatment unit and bypass
Z40619 6.61.1.7 250/300 cast iron/AL size 25, with flushing oil treatment unit and bypass
Z45560 6.62.1 40 nodular cast iron with heating and bypass filter
11.10.2002 PC 134-00
S a f e t y n e e d s q u a l i t y.
efficient, economical
BOLL & KIRCH Filterbau GmbH
T H E TA S K
Effective lubricating oil cleaning in
heavy oil operation
The economic operation of small and medium-sized die-
sel engines and generators with heavy oil over a long
period makes increased demands on the cleaning of lu-
bricating oil. The quality of filtration of the lubricating oil
is one of the factors determining its useful life, smooth en-
gine operation and hence also the level of operating costs.
The filters used for this purpose must
• have a precision that will guarantee a specific degree of
cleanliness of the circulating lubricating oil,
• have a reliability that will ensure uninterrupted and
trouble-free engine running during operation over a
long period even in the case of variable engine and
lubricating oil conditions,
• prolong the life of the engine, by protecting engine
bearings and reducing wear on bearings,
• help to keep operating costs low, being maintenance-
free, with long service lives,
• reduce the costs of the consumable materials used up
to now,
• be more economical than double filters with paper car-
tridges.
Trusted by
shipbuilders and
marine engineers
the world over:
BOLLFILTERS.
The SELFCLEAN
TYPE 6.46
is equally suitable for
vertical ...
The BOLL Concept separates filtration from lubricating oil over the function of an indicator filter . In both cases, the
care. The BOLL SELFCLEAN TYPE 6.46 automatic filter ful- BOLL SELFCLEAN TYPE 6.46 automatic filter keeps all
fils the task of lubricating oil filtration in the best possible solids away from the bearings. Removal of combustion re-
way. It can be fitted directly to the engine as a main flow sidues from the lubricating oil, on the other hand, it is car-
filter . Another solution is to incorporate it in the plant’s ried out by a separator or another auxiliary flow treatment
pipe system, possibly with additional flushing oil treat- section. This solution has proved to be advantageous both
ment. A double filter fitted directly onto the engine takes with regard to operational safety and from the point of
view of economy.
Separator
Pump protection filter
The BOLL SELFCLEAN TYPE 6.46 automatic filter’s superi- rough cleaning of the layer of dirt which has built up on
ority is demonstrated not only by a perfect filtration result, the inside of the candle, whilst protecting the filter mesh.
but also by the best possible operating behaviour. Its Even backflushing over a long period is achieved with
high-precision construction is convincingly simple and small quantities of flushing oil and prevents any drop in
robust. The SELFCLEAN 6.46, which can be mounted ho- the operating pressure.
rizontally or vertically as an attachment or plug-in filter,
has a housing made from grey cast iron. The filter is avail- If the filter candle cleaning operation is disturbed or inter-
able in various sizes with nominal diameters up to 150 rupted, once the differential pressure reaches 2 bar, the
mm and can be easily adapted to engine manufacturers’ overflow valves open and the lubricating oil is filtered
special requirements. via a protective mesh
incorporated as a second filter
stage. However before this stage is reached, the differen-
During the filter operation, the lubricating oil to be filte- tial pressure indicator will register the disturbance and
red passes through the inlet flange into the housing sec- trigger an alarm if it continues.
tion . A partial flow of ca. 50% of the unfiltered oil is fed
via the central riser pipe in the mesh insert into the upper
part of the filter housing and into the filter
candle , which is open at both ends,
from above. The other half flows
from below into the filter candle.
The candles’ filter mesh makes it
possible to have filtration grades
DESIGN
In-/Outlet DN 50 DN 65 DN 80 DN 100 DN 125 DN 150
Output m3/h min. 3 5 7 10 22 22
max. 18 32 48 78 130 179
Flushing quantity in m /h
3
Commercial production on CNC and DNC Various storage and logistics systems sup- BOLLFILTER genuine parts leave the facto-
controlled machine tools. port smooth and effective production. ry within 24 hours.
T H E A D VA N TA G E S
Economically and ecologically trend-
setting
In economic terms, the best is always the result of “as
much as possible” for “as little as necessary”. Where the
use of lubricating oil is concerned, this means: consistent,
precise filtration and regeneration of the lubricant with
minimal losses, a requirement for a forward-looking busi-
ness. One-off investment in high quality filter systems be-
comes more cost-effective with increased service life and
improved protection of rotating machinery. And even in
the majority of existing plants, expansion and improve-
ment is possible when replacement time comes along.
400
M12
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATIONS AU SOL
BETRIEBSDRUCK INHALT
WORKING PRESSURE 2-10 BAR VOLUME 15LTR. GEHAEUSE GEGOSSEN
PRESSION DE SERVICE VOLUME HOUSING CASTED
CORPS MOULE
BETRIEBSTEMPERATUR GEWICHT
WORKING TEMPERATURE MAX. 100°C WEIGHT 64KG GEGENFLANSCHE,DICHTUNGEN UND SCHRAUBEN
TEMPERATURE DE SERVICE POIDS GEHOEREN ZUM LIEFERUMFANG
COUNTER FLANGES,GASKETS AND BOLTS BELONG TO
TOLERANZEN DELIVERY
TOLERANCE ISO 2768-m FRONT PARTIE DE LA FORNITURE CONTIE-BRIDES
TOLERANCE JOINTS ET LA BOULONNERIE UNIQUEMENT
DIFFERENZDRUCK-ANZEIGER SIEBAUSBAU
DIFFERENTIAL-PRESSURE-INDICATOR DISMOUNTING THE FILTER ELEMENT
INDICATEUR DE PRESSION DIFF. DEMONTAGE DU PANIER
400
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATIONS AU SOL
BETRIEBSDRUCK INHALT
WORKING PRESSURE 2-10 BAR VOLUME 20LTR. GEHAEUSE GEGOSSEN
PRESSION DE SERVICE VOLUME HOUSING CASTED
CORPS MOULE
BETRIEBSTEMPERATUR GEWICHT
WORKING TEMPERATURE MAX. 100°C WEIGHT 73KG GEGENFLANSCHE,DICHTUNGEN UND SCHRAUBEN
TEMPERATURE DE SERVICE POIDS GEHOEREN ZUM LIEFERUMFANG
COUNTER FLANGES,GASKETS AND BOLTS BELONG TO
TOLERANZEN DELIVERY
TOLERANCE ISO 2768-m ONT PARTIE DE LA FOURNITURE: CONTRE-BRIDES
TOLERANCE JOINTS ET LA BOULONNERIE UNIQUEMENT
SIEBAUSBAU
DISMOUNTING THE FILTER ELEMENT B
DEMONTAGE DU PANIER
D
M
OK
G
C
F
A
N
P
L
E
DIFFERENZDRUCK-ANZEIGER
DIFFERENTIAL-PRESSURE-INDICATOR
INDICATEUR DE PRESSION DIFF.
160
75
13
H R
M16 BETRIEBSDRUCK
100 WORKING PRESSURE 2-10 BAR
140 PRESSION DE SERVICE SPÜLÖL-AUSTRITT "dn"
BETRIEBSTEMPERATUR
FLUSHING OIL OUTLET
U Z SORTIE HUILE DE RINCAGE
WORKING TEMPERATURE MAX. 100°C
TEMPERATURE DE SERVICE
TOLERANZEN
TOLERANCE DIN ISO2768-m
TOLERANCE
V
GEHÄUSE GEGOSSEN
HOUSING CASTED
CORPS MOULE
ANSCHLUSSFLANSCHE FÜR DN 125+150
Y
CONNECTION FLANGES FOR DN 125+150 DIN 2501 PN10
W BRIDES DESIREES POUR DN 125+150
DN A B C D E F G H øK L M N P R S U V W X Y Z dn GEWICHT
KG
INHALT
LITER
50 MASSBLATT Z40113 /DIMENSION PAGE /FEUILLET DE MODELE
65 MASSBLATT Z39879 /DIMENSION PAGE /FEUILLET DE MODELE
80 435 305 515 100 85 255 615 170 285 90 130 130 M16 105 400 46 200 195 160 160 14 32 77 33
100 485 365 515 100 85 295 615 200 325 116 160 160 M16 115 400 48 220 220 180 180 14 32 112 41
125 580 405 670 120 85 350 790 260 405 DIN2501 PN10 140 600 55 270 270 220 220 14 40 195 79
150 655 ø490 670 130 85 375 800 300 460 DIN2501 PN10 155 600 58 330 310 290 260 18 40 250 102
SUBJECT TO ALTERATIONS ÄNDERUNGEN VORBEHALTEN! MODIFICATIONS RÉSERVÉES
T
S
D
BETRIEBSDRUCK
M
BETRIEBSTEMPERATUR
WORKING TEMPERATURE MAX. 100°C
TEMPERATURE DE SERVICE
G
øK
TOLERANZEN
TOLERANCE DIN ISO 2768-m
F
TOLERANCE
N
M16
GEHAEUSE GEGOSSEN
HOUSING CASTED
O
CORPS MOULE
L
E
EINTRITT Q
INLET
ENTREE SPUELOEL-AUSTRITT DN32 ANSCHLUSSFLANSCHE F.DN125+150
FLUSHING OIL OUTLET CONNECTION FLANGES FOR DN125+150 DIN2501 PN 10
SORTIE HUILE DE RINCAGE BRIDES DESIREES POUR DN125+150
DIFFERENZDRUCK-ANZEIGER
DIFFERENTIAL-PRESSURE-INDICATOR
INDICATEUR DE PRESSION DIFF.
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATIONS AU SOL
V
X
A
Z
Y
W
H
GEWICHT
DN A B C D E F G H øK L M N O Q R S T U V W X Y Z KG
50 348 225 515 100 85 255 615 125 200 62 110 110 685 345 630 400 100 40 160 160 130 130 14 94
65 395 245 515 100 85 255 615 160 222 78 130 130 685 345 640 400 100 40 160 160 130 130 14 103
80 435 305 515 100 85 255 615 170 285 90 130 130 685 345 670 400 100 46 200 195 160 160 14 107
100 485 365 515 100 85 295 615 200 325 116 160 160 685 355 710 400 100 48 220 220 180 180 14 142
125 580 405 670 120 85 350 790 260 405 DIN2501 PN10 1000 380 755 600 550 58 270 270 220 220 14
150 655 ø490 670 130 85 375 800 300 460 DIN2501 PN10 1000 395 810 600 550 58 330 310 290 260 18
The BOLL automatic filter SELFCLEAN TYPE 6.60/6.61 is ter chamber with cleaned filter candles is always held in
designed precisely to fulfil the task. The filter housing is reserve, whilst the other filter chambers are simultane-
equipped with several filter chambers. Each filter cham- ously providing the filtration function. As the amount of
ber contains a filter insert made-up of a number of filter contamination increases, the differential pressure indica-
candles, each candle is made from a spiral-wound sup- tor initiates the back-flushing phase via the electronic
port structure over which high-grade filter mesh is drawn. control. Compressed air is used for cleaning the filter
Large filter surfaces with high “free passage” areas gua- candles. The system pressure remains constant and the
rantee a low pressure differential. As each filter chamber flushing quantities produced are very low. Additionally,
becomes dirt-loaded, it is isolated from flow and regene- the compact construction means little space is required to
rated by back-flushing, each in sequence with no inter- install the filter. This filter series can be provided with a
ruption to operation. During the filtration process one fil- sludge treatment unit on request.
During the filtration operation the liquid to be filtered en- nism until the inlet and outlet to one contaminated cham-
ters through the inlet into the change-over housing, on ber is blocked, simultaneously releasing the reserve
which the filter chambers with the filter candles are chamber. Now the sludge discharge valve opens and
mounted. The rotary selector mechanism is located in the blocked chamber is depressurised. At the same time
the centre of the housing. The contaminated liquid is fed the filter-stored compressed air is explosively released
into the filter chambers and flows through the filter can- from the upper hollow space of the selector mechanism
dles from outside to inside. The solids to be filtered out are and discharges the liquid from the selector mechanism
retained on the filter mesh. Cleaned liquid passes through and the closed-off filter chamber. In parallel with the
the inside of the candle to the filter outlet in the lower pressure release the flushing valve
opens. The com-
section of the housing. pressed air from the air reservoir accelerates the clean
During this process one filter chamber is held in reserve liquid in the filter chamber and pushes it in the reversed
with cleaned filter candles, separate from the filtration flow through the filter candles. Due to the pressure burst,
process, the sludge discharge valve is closed and com- the dirt particles are flushed off the filter mesh and out of
pressed air is stored in the air reservoir. the filter housing through the opened sludge discharge
The growing layer of dirt on the filter mesh results in a valve .
pressure differential between the dirty side and the clean Compressed air then continues to flow for a short period,
side; self-cleaning of one filter chamber is automatically then the sludge discharge valve and flushing valve are
triggered once this differential reaches a predetermined again closed. The now clean but empty chamber is filled
value. The electric motor (or, in the case of the TYPE with clean liquid via a top-up bore in the selector me-
6.60 a pneumatic drive system) turns the selector mecha- chanism, to become the reserve chamber, ready to be
brought into use on next signal.
Filtration Backflushing
Filtration of the back-flushing liquid
T H E D E TA I L S
Data and Facts at a glance
SELFCLEAN TYPE 6.60 / 6.61 Multi-chamber automatic filter with compressed-air back-flushing
Range of application Lubricating oil, diesel oil, heavy fuel oil, cutting oil, emulsions, coolant, industrial wash liquids
Operating pressures up to 10 bar (higher pressures on request)
differential pressure resistance up to operating pressure
Operating temperature up to 150ºC
Housing material grey cast iron and ductile iron
Nominal width coupling flange DN 50 - DN 350
Max. flow rate 800 m3/h
Filtration fineness up to 10 microns absolute
Filter candle type Cylindrical screw-in candles with woven mesh
Cleaning method Sequential, reversed flow back-flushing , assisted by compressed air
Back-flushing control Differential pressure dependent or time-dependent
Technical data Type Size Number of chambers Total number Filtration area Weight of filter (kg)
Total In use of filter candles in use cm2 Empty Filled
BOLL & KIRCH concentrate exclusively on the design and The global presence of BOLL & KIRCH in all important in-
manufacture of liquid/solid separation filters. Most BOLL- dustrial centres guarantee to customers worldwide the
FILTERs are the result of our own research and develop- reliability and service that they expect of a supplier of
ment and are protected by patents. Customers can take technologically exacting filter systems, a service that in-
advantage of our knowledge by involving our technicians cludes dispatching BOLLFILTER genuine parts all over
and engineers in the early phases of their projects. Focus- the world within 24 hours.
sing the knowledge of both partners in simultaneous en-
gineering ensures a perfect result.
Commercial production on CNC and DNC Modern storage and logistics systems sup- BOLLFILTER genuine parts leave the cen-
controlled machine tools. port smooth and effective production. tral warehouse within 24 hours.
BOLL Automatic filters type 6.60/6.61 – the advantages include the following:
S
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
EIN-BZW. AUSTRITT
HEIZUNG ø22
IN RESPECT. OUTLET
HEATING ø22
ENTREE RESPECT. SORTIE
CHAUFFAGE ø22
L
DN
F
H
DN
U
E
h
R
T P SCHLAMMABLASS dn V D
D
MUD DRAIN
VENTILAUSBAU VIDANGE DE BOUES
W
DISMOUNTING OF THE VALVE
DEMONTAGE DE LA VANNE DRUCKLUFT MIN 4BAR
AIR PRESSURE N
PRESSION D'AIR
LUFTANSCHLUSS ø8x1
AIR CONNECTION
PRISE D'AIR
B
Z
M
Y
d
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXAUTION AU FOND
X
A
AT AT
BETRIEBSDRUCK FILTERRAUM HEIZRAUM
WORKING PRESS.FILTER CHAMBER max.16 BAR BEI 140°C HEATING CHAMBER 14 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR CHAMBRE DE CHAUFFAGE PAR
50
05 2 475 410 110 195 120 415 895 205 210 265 65 300 200 300 240 33 240 37 240 12 18 50 100 15
65
SUBJECT TO ALTERATIONS! AENDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES!
FULLY AUTOMATIC BACK VOLLAUTOMATISCHER RUECKSPUELFILTER FILTRE AUTOMATIQUE
FLUSHING FILTER TYP 6.60
Z45559
TYP6.60.07
11.12.02
EIN-BZW. AUSTRITT
HEIZUNG ø22 N.AUFTRAG
IN RESPECT. OUTLET
S
HEATING ø22 ACC. TO ORDER
ENTREE RESPECT. SORTIE
CHAUFFAGE ø22 APRES COMMANDE
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
Z
EINTRITT DN
INLET
L
ENTREE
F
H
E
R
h
I
T P D Q C
l
AUSTRITT DN
OUTLET
REINOELAUSTRITT G3/4 SORTIE
VENTILAUSBAU
CLEANOIL OUTLET
DISMOUNTING OF THE VALVE
SORTIE OLE L'HUILE TUBRIFITEE
DEMONTAGE DE LA VANNE
DRUCKLUFT MIN 4 BAR
AIR PRESSURE
PRESSION D'AIR
A LUFTANSCHL.ø8x1
AIR CONNECTION
PRISE D'AIR K
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATION AU FOND
O
ød
V
B
GEHAEUSE GEGOSSEN
M
RESERVOIR A AIR
LUFTSPEICHER
AIR-RESERVOIR
PS P
FILTRATIONSPHASE
TYP 6.60.07 FILTRATION-PHASE
PHASE DE FILTRATION
Z33703 BL.2
TYP6.60.07
12.02.98
RESERVOIR A AIR
LUFTSPEICHER
AIR RESERVOIR
PS P
AUFFUELLBOHRUNG
REFILL BORE
TROU DE REMPLISSAGE
RUECKSPUELPHASE
TYP 6.60.07 BACK-FLUSHING-PHASE
POSITION DE LAVAGE A
CONTRE-COURANT
Z32570
TYP6.60.1
12.07.02
ANSICHT X
VIEW X
VUE X
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
EINTRITT DN50
EIN- BZW. AUSTRITT HEIZUNG ø22 INLET
IN RESPECTIVELY OUTLET HEATING ø22 ENTREE
ENTREE RESPECT. SORTIE CHAUFFAGE ø22
"Z"
ANSICHT Z
VIEW Z DRUCKLUFT MIN. 4BAR
VUE Z AIR PRESSURE
PRESSION D'AIR
LUFTANSCHLUSS ø8x1
AIR CONNECTION
PRISE D'AIR
ANSICHT Y FREIMASSTOLERANZEN
VIEW Y TOLERANCE ISO 2768-m BODENBEFESTIGUNG
VUE Y TOLERANCE BOTTOM FASTENING
"Y" FIXAUTION AU FOND
ø12
"X"
GEGENFLANSCHE IM LIEFERUMFANG
COUNTER FLANGES INCLUDED
CONTRES BRIDES INCLUS
VENTILAUSBAU
DISMOUNTING OF THE VALVE
DN50 DEMONTAGE DE LA VANNE
FILTERKOMBINATION
FILTER COMBINATION
TYP 6.60.1 GR.05 COMBINAISON DE FILTRES
Z33675
TYP6.60.1.7
16.07.97
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
GEGENFLANSCHE IM LIEFERUMFANG
COUNTER FLANGES INCLUDED EINTRITT DN50
CONTRES BRIDES INCLUS INLET
ENTREE "X"
FREIMASSTOLERANZEN
TOLERANCE DIN ISO 2768-m
TOLERANCE
HEIZRAUM AT
HEATING CHAMBER 14 BAR BEI 200°C
CHAMBRE DE CHAUFFAGE PAR
GEHAEUSE GEGOSSEN
HOUSING IN CAST IRON
CORPS MOULE
GEWICHT 157 KG
WEIGHT 157 KG
POIDS 157 KG
AUSTRITT DN50
OUTLET EIN-BZW. AUSTRITT
SORTIE
HEIZUNG ø22
SIEBAUSBAU IN RESPECTIVELY
DISMOUNTING THE SIEVE OUTLET HEATING ø22
DEMONTAGE DU PANIER ENTREE RESPECT.
SORTIE CHAUFFAGE ø22
REINOELAUSTRITT G3/4
CLEANOIL OUTLET
SORTIE OLE L'HUILE TUBRIFITEE
BODENBEFESTIGUNG
BOTTOM FASTENING
ANSICHT X FIXAUTION AU FOND
VIEW X
VUE X
ø13.5
ø12
ø18
VENTILAUSBAU
DISMOUNTING OF THE VALVE
DEMONTAGE DE LA VANNE
SUBJECT TO ALTERATIONS! AENDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES!
SIEBAUSBAU
DISMOUNTING THE SIEVE
S
DEMONTAGE DU PANIER
G
L
DN
F
H
SCHLAMMABLASS
MUD DRAIN
VIDANGE DE BOUES
DN
dn
E
b
R
c D a C
DRUCKLUFT MIN. 4 BAR
T P AIR PRESSURE C1
PRESSION D'AIR
VENTILAUSBAU LUFTANSCHLUSS ø8x1
DISMOUNTING OF THE VALVE AIR CONNECTION
DEMONTAGE DE LA VANNE PRISE D'AIR
X
M
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATION AU FOND
d
N
Z
Y
B
80 200
10 4 600 460 200 - 140 135 315 476 515 1110 200 200 250 95 300 200 270 55 270 105 165 225 18 15 50 38
100 215
150 310 - 345
15 7 680 690 170 165 375 476 605 1250 300 300 250 95 300 200 370 55 370 105 165 225 18 15 50 71
200 - 580 395
200 335 - 620
20 6 850 750 275 225 475 485 750 1420 400 400 350 125 300 250 500 75 500 165 165 240 27 25 100 150
250 - 645 690
S
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
G
Z
L
DN
F
H
DN
E
h
R
T P D Q C
DRUCKLUFT MIN. 4 BAR C1
AIR PRESSURE
VENTILAUSBAU
PRESSION D'AIR K
REINOELAUSTRITT G3/4 LUFTANSCHLUSS ø8x1
DISMOUNTING OF THE VALVE CLEANOIL OUTLET AIR CONNECTION
DEMONTAGE DE LA VANNE SORTIE OLE D'HUILE TUBRIFITEE PRISE D'AIR
BODENBEFESTIGUNG
V
BOTTOM FASTENING
FIXATION AU FOND
d
b
B
c
O
GEHAEUSE GEGOSSEN
M CASTED HOUSING
a CORPS MOULE
FREIMASSTOLERANZEN ANSCHLUSSFLANSCHE PN
X DIN ISO 2768-m
TOLERANCE CONNECTION FLANGE DIN 2501 PN 10
TOLERANCE BRIDES DESIREES PN
80 227
10 4 895 500 200 - 380 135 315 476 515 55 200 1110 200 200 75 250 200 95 300 200 700 560 600 560 270 270 55 18 15 67
100 242
150 310 - 372
15 7 965 690 410 165 375 476 605 55 200 1250 300 300 75 250 200 95 300 200 700 590 680 560 370 370 55 18 15 100
200 - 580 422
200 335 - 663
20 6 1250 800 575 225 475 485 750 55 246 1420 400 400 150 350 235 125 300 250 950 770 850 810 500 500 75 27 25 206
250 - 645 733
RESERVOIR A AIR
AIR-RESERVOIR
LUFTSPEICHER
P
PS
FILTRATIONSPHASE
TYP 6.61.07 FILTRATION-PHASE
PHASE DE FILTRATION
Z33701 BL.2
TYP6.61.07
12.02.98
RESERVOIR A AIR
LUFTSPEICHER
AIR-RESERVOIR
P
PS
SPUELFLUESSIGKEIT
BACK-FLUSHING-FLUID
LIQUIDE DE RETROLAVAGE
RUECKSPUELPHASE
TYP 6.61.07 BACK-FLUSHING-PHASE
POSITION DE LAVAGE A
CONTRE-COURANT
Z32568
TYP6.61.1 GR.10
22.11.99
300 SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
AUSTRITT DN100
OUTLET
SORTIE
EINTRITT DN100
INLET
ENTREE
EIN-BZW.AUSTRITT
HEIZUNG ø22
(NACH AUFTRAG)
IN-RESPEC.OUTLET
HEATING ø22
(ACCORDING TO ORDER)
ENTREE RESPEC.SORTIE
CHAUFFAGE ø22
(APRES COMMANDE)
DRUCKLUFT MIN.4 BAR LUFTANSCHL.ø8X1
AIR PRESSURE AIR CONNECTION
PRESSION D'AIR PRISE D'AIR
SCHLAMMABLASS
MUD DRAIN
DN50 VIDANGE DE BOUES ø14
ø18
VENTILAUSBAU
DISMOUNTING OFTHE VALVE FREIMASSTOLERANZEN
DEMONTAGE DE LA VANNE TOLERANCE ISO 2768-m
TOLERANCE
FILTER COMBINATION
FILTERKOMBINATION COMBINAISON DE FILTRES
TYP 6.61.1 GR.10
Z40618
TYP6.61.1 GR.15
22.02.02
SIEBAUSBAU
300
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
AUSTRITT DN150
680
OUTLET
SORTIE
EIN-BZW.AUSTRITT
HEIZUNG ø22
(NACH AUFTRAG)
IN- RESPEC.OUTLET
HEATING ø22
(ACCORDING TO ORDER)
ENTREE RESPEC.SORTIE
CHAUFFAGE ø22
(APRES COMMANDE)
DRUCKLUFT
MIN 4 BAR
AIR PRESSURE
PRESSION D'AIR
LUFTANSCHL.ø8x1
AIR CONNECTION
PRISE D'AIR
VENTILAUSBAU
200
AUSTRITT DN200
OUTLET
SORTIE SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
SCHLAMMABLASS DN100
MUD DRAIN DRUCKLUFT MIN. 4 BAR EINTRITT DN200
VIDANGE DE BOUES AIR PRESSURE INLET
PRESSION D'AIR ENTREE
LUFTANSCHLUSS ø8x1
AIR CONNECTION
PRISE D'AIR
FREIMASSTOLERANZEN
TOLERANCE DIN 7168 "SG"
TOLERANCE
FILTER COMBINATION
FILTERKOMBINATION COMBINAISON DE FILTRES
TYP 6.61.1 GR.20
Z40617
TYP6.61.1 GR.25
01.12.97
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
300
AUSTRITT DN250
1010
OUTLET
SORTIE
DN100
250
GEHAEUSE GEGOSSEN
VENTILAUSBAU CASTED HOUSING
DISMOUNTING OFTHE VALVE CORPS MOULE
DEMONTAGE DE LA VANNE
NP FREIMASSTOLERANZEN
ANSCHLUSSFLANSCHE
CONNECTION FLANGE DIN 2501 ND10
TOLERANCE DIN ISO 2768-m
TOLERANCE
BRIDES DESIREES PN
FILTERKOMBINATION
FILTER COMBINATION
TYP 6.61.1 GR.25 COMBINAISON DE FILTRES
Z33960
TYP6.61.1.7 GR.10
30.06.98
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
"X"
SIEBAUSBAU
AUSTRITT DN100 DISMOUNTING THE SIEVE
OUTLET DEMONTAGE DU PANIER
SORTIE
REINOELAUSTRITT G3/4
CLEANOIL OUTLET
SORTIE OLE L'HUILE
DRUCKLUFT EINTRITT DN100 TUBRIFITEE
INLET
MIN 4 BAR ENTREE
ANSICHT "X" AIR PRESSURE
PRESSION D'AIR
VIEW "X" ø13.5
VUE "X" LUFTANSCHL.ø8x1
AIR CONNECTION BODENBEFESTIGUNG
PRISE D'AIR BOTTOM FASTENING
FIXATION AU FOND
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
ø14
ø18
FREIMASSTOLERANZEN
TOLERANCE DIN ISO 2768-m
TOLERANCE
ANSCHLUSSFLANSCHE NP
CONECTION FLANGE DIN 2501 ND10
BRIDES DESIREES
PN
GEHAEUSE GEGOSSEN
CASTED HOUSING
CORPS MOULE
REINOELAUSTRITT G3/4
CLEANOIL OUTLET
SORTIE OLE L'HUILE
VENTILAUSBAU TUBRIFITEE
DISMOUNTING OF THE VALVE
DEMONTAGE DE LA VANNE
SUBJECT TO ALTERATIONS! AENDERUNGEN VORBEHALTEN! MODIFICATIONS RESERVEES!
FILTER COMBINATION WITH FILTERKOMBINATION MIT SPUELOELAUFB.
COMBINAISON DE FILTRES
FLUSH OIL TREATMENT TYP 6.61.1.7 GR.10 AVEC PREPARATEUR D'HUILE
Z40620
TYP 6.61.1.7 GR.15
10.09.98
SIEBAUSBAU
DISMOUNTING THE SIEVE
300
DEMONTAGE DU PANIER
680
AUSTRITT DN150 "X"
OUTLET
SORTIE
SIEBAUSBAU
DISMOUNTING THE SIEVE ø13.5
DEMONTAGE DU PANIER
ANSICHT "X"
VIEW "X"
VUE "X"
ø18
ø18
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATION AU FOND
REINOELAUSTRITT G3/4
CLEANOIL OUTLET
SORTIE OLE L'HUILE
TUBRIFITEE
GEHAEUSE GEGOSSEN
CASTED HOUSING
CORPS MOULE
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
AUSTRITT DN250
300
OUTLET
SORTIE
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
"X"
DRUCKLUFT LUFTANSCHL.ø8x1
MIN 4 BAR AIR CONNECTION
EINTRITT DN250
AIR PRESSURE PRISE D'AIR
PRESSION D'AIR INLET
ANSICHT "X" ENTREE
VIEW "X"
VUE "X"
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
REINOELAUSTRITT G3/4
CLEANOIL OUTLET
SORTIE OLE L'HUILE
TUBRIFITEE
ø13.5
BODENBEFESTIGUNG
BOTTOM FASTENING
FIXATION AU FOND
ø18
250
ANSCHLUSSFLANSCHE NP FREIMASSTOLERANZEN
CONECTION FLANGE DIN 2501 ND10 TOLERANCE DIN ISO 2768-m
BRIDES DESIREES TOLERANCE
PN
The BOLL automatic filter SELFCLEAN TYPE 6.62 opti- an exhausted one. The point of exhaustion is determined
mally meets the requirements outlined. This is attained by through the pressure difference between dirty and clean
a filter design based on several chambers which may be side. Regeneration is extremely fast, thorough and easy on
separated from each other in which the functions of filte- the mesh, and is supported by compressed air. The system
ring and regeneration are performed separately. pressure is maintained at a constant level and the flushing
The filter housing contains four filter chambers, with each quantities are small.
chamber containing a filter candle. These operate as a sin- In addition, a heating chamber has been integrated in the
gle system whereby the filtering task is split internally bottom section of the housing. This chamber ensures that
among the four candles. This is done in such a way that the discharged clean fluid is maintained at the temperatu-
always one is paused so that it may regenerate whilst the re needed for its further use.
others continue to filter. Once the capacity of the working
filter candles is exhausted, the fresh filter candle replaces
SELFCLEAN TYPE 6.62 Multi-chamber automatic filter with compressed air back-flushing
Range of application heavy fuel oil, diesel oil, lubricating oil
Operating pressure 1 to 16 bar (higher pressures on request)
Differential pressure resistance up to operating pressure
Housing material ductile graphite iron (GGG)
Nominal width coupling flanges DN 40
Type of filter candle / mesh cylindrical screw-in candles with woven mesh
Cleaning method sequential, reversed flow back-flushing with compressed air support
Back-flushing control differential pressure dependent or time dependent
Technical data
Booster system (t max. 150 °C) Supply system (t max. 100 °C)
Mesh micron Flow rate m /h
3
Mesh micron Flow rate m3/h
50 5,5 50 2,5
34 5,5 34 2,5
25 2,2 25 1,0
10 1,0
BOLL & KIRCH focuses its activities exclusively on the The global presence of BOLL & KIRCH in all important in-
manufacture of liquid/solid separating filters. Many dustrial centres guarantees to customers world-wide the
BOLLFILTERS are the result of own research and deve- reliability and service they expect from a supplier of tech-
lopment activities and are protected by patents. Custo- nology-wise demanding filter systems. This includes
mers can take advantage of our know-how by involving dispatching of BOLLFILTER genuine parts from all over
our technicians and engineers during the early phases of the world within 24 hours.
their projects. Focussing the know-how of both partners
in simultaneous engineering ensures a perfect result.
Economic production on CNC and DNC Modern warehousing and logistics BOLLFILTER genuine parts leave the cen-
controlled machines. systems support speedy and effective tral warehouse within 24 hours.
production.
T H E A D VA N TA G E S
Economically and ecologically leading
SIEBAUSBAU
DISMOUNTING THE SIEVE
DEMONTAGE DU PANIER
S
L
LUFTANSCHLUSS ø8x1
H
AIR CONNECTION
PRISE D'AIR
EINTRITT DN
INLET
F
ENTREE
AUSTRITT DN
OUTLET
SORTIE
N
E
h
SCHLAMMABLASS dn b
MUD DRAIN M V
VIDANGE DE BOUES
EIN-BZW. AUSTRITT HEIZUNG ø22
A
IN RESPECTIVELY OUTLET HEATING ø22
ENTREE RESPECT. SORTIE CHAUFFAGE ø22
AT
BETRIEBSDRUCK FILTERRAUM
max.16 BAR BEI 160°C
WORKING PRESS.FILTER CHAMBER
PRESS.DE SERVICE CHAMBRE FILT. PAR
HEIZRAUM AT
B
FREIMASSTOLERANZEN
TOLERANCE DIN ISO 2768-m
TOLERANCE
C
GEGENFLANSCHE IM LIEFERUMFANG
COUNTER FLANGES INCLUDED
CONTRES BRIDES INCLUS
Z
Y
GEHAEUSE GEGOSSEN
HOUSING IN CAST IRON
CORPS MOULE
GEWICHT INHALT
GR. DN A B C D E F H L M N S U V W X Y Z b h d dn KG LTR
40
04 375 325 110 140 140 120 620 875 165 130 500 45 110 190 160 190 160 45 15 13.5 25 105 14
SIEBAUSBAU
DISMOUNTING THE SIEVE
L
DEMONTAGE DU PANIER
S1
EINTRITT DN
INLET
ENTREE
S2
H2
H1
F
E
N
U
U
b K
DRUCKLUFT MIN 4BAR M V
AIR PRESSURE
SCHLAMMABLASS dn "Y"
PRESSION D'AIR MUD DRAIN "X" AUSTRITT DN
LUFTANSCHLUSS ø8x1 VIDANGE DE BOUES
AIR CONNECTION OUTLET
PRISE D'AIR SORTIE A
"Y" Od
B
"X" Z
Y
R O P
BETRIEBSDRUCK FILTERRAUM AT HEIZRAUM AT
WORKING PRESS.FILTER CHAMBER max.16 BAR BEI 160°C HEATING CHAMBER 14 BAR BEI 200°C
PRESS.DE SERVICE CHAMBRE FILT. PAR CHAMBRE DE CHAUFFAGE PAR
FREIMASSTOLERANZEN GEHAEUSE GEGOSSEN GEGENFLANSCHE IM LIEFERUMFANG
TOLERANCE DIN ISO 2768-m HOUSING IN CAST IRON COUNTER FLANGES INCLUDED
TOLERANCE CORPS MOULE CONTRES BRIDES INCLUS
GEWICHT INHALT
GR. DN A B E F G H1 H2 K L M N O P R S1 S2 U V W X Y Z b h d dn KG LTR
40
04 700 325 140 120 100 620 370 80 875 165 130 220 190 215 500 230 45 110 190 160 190 160 45 15 13.5 25 140 19
dimensional
filtertype connection material remarks
drwg.
10.10.2002 PC 134-00
INDEX
chapter 11 Change-over valves
dimensional
filtertype connection material remarks
drwg.
10.10.2002 PC 134-00
Z101010
TYP3.95.2
14.01.03
VARIANTE VARIANTE
DESIGN 1 DESIGN 2
EXÉCUTION EXÉCUTION
F
F
H
E
E
D
B
D
B
X X
POS.1
H
A
DN
A
DN
DN
PN II
GEHÄUSE: EN-GJS-400-15
BESTELLBEISPIEL TYP
CASING: CAST IRON WITH SPHEROIDAL
GR. DN PN
ORDERING EXAMPLE
3.95.2
CORPS: FONTE SPHÉROLITIQUE
EXEMPLE DE COMMANDE 10 100 40
GEWICHT
VARIANTE
DN GR. PN/120°C A B D E F H VOLUMEN WEIGHT
MODIFICATION
I II KG
VARIANTE LITER POIDS
C
C
OM OM
L=F-2xC S
L
S
F
L
OI
ØI
C
C
E
D
POS.1
H
DN
A
A
DN DN
X B
X
10.10.2002 PC 134-00
Z100810
TYP5.01
27.01.99
II I
SIEBGROESSE
L2
SIEVE SIZE
GRANDEUR DE PANIER
250 500 750
L1
NR. L1 L2 L3
I 290 520 790
II 520 790
OEFFNUNG DER RINGDUESE 0.1MM
OPENING OF RING-JET 0.1MM
OUVERTURE DE LA BUSE A ANNEAU 0.1MM
NR. L
1 300
2 600
3 900
F
C
CLEANING LANCE
G
PUMP PROTECTION FILTER
A PUMP
DRAIN G1
D E
TECHNICAL DESCRIPTION:
CONTAINER: MILD SHEET STEEL CONSTRUCTION CONSISTING OF A SOAKING TANK, A SPRAYING TANK, SUMP AND TROLLEY FRAME WITH 4 CASTORS
CLEANING PISTOL: HAND PISTOL WITH 5M HIGH-PRESSURE HOSE WITH QUICK-ACTION COUPLING
INTERCHANGEABLE CLEANING LANCE.
RECOMMENDED CLEANING AGENT: " BOLL CLEAN 2000 "
*THE SIZES QUOTED BELOW RELATE TO THE MAXIMUM SIZE OF FILTER ELEMENT WHICH CAN BE CLEANED (Ø / HEIGHT)
WEIGHT VOLUME
SIZE KG LTR.
GEWICHT INHALT
* GROESSE A B C qD qE F G T KG LTR.
355/500 995 500 1000 370 500 520 125 570 95 130
435/750 1285 700 1260 460 700 780 125 780 140 308
PRODUCT PROFILE
BOLL CLEAN 2000 is a liquid cleaning and degreasing agent with a brod spectrum of applications.
It can be used for virtually all cleaning and degreasing purposes.
BOLL CLEAN 2000 can be mixed with any type of water -including seawater. BOLL CLEAN 2000
cleans quickly and thoroughly and is extremely economical. Even at concentrations of 1 part in 50
parts water, it offers good cleaning and degreasing properties.
The use of BOLL CLEAN 2000 does not require any safety measures.
BOLL CLEAN 2000 offers all these outstanding characteristics without the disadvantages of
solvent-based cleaner.
BOLL CLEAN 2000 is not combustible,
not subject to identifacion marking regulations,
without unpleasant smell,
not chemically aggressive,
physiologically safe.
biologically decomposable
Umweltbundesamt Reg.-Nr. 04860019
BOLL CLEAN 2000 can be stored at low or high temperatures and will recover its functional
properties after is has returned to normal temperature.
RANGE OF APPLICATIONS
BOLL CLEAN 2000 is suitable for cleaning and degreasing metals, plastics, firmly adhering paint
finishes and similar surfaces. It removes oil, wax, grease, soot and a large of number of other
deposits.
BOLL CLEAN 2000 is used in the car industry, in shipping, in the oil industry (for drilling
equipment), in the food and beverages industries, in the metall-working industry, in reconditioning
and mechanical engineering workshops, for diesel and electric locomotives, for cleaning
generators in power stations, and for many other purposes.