Connection No - C08-C2: Shear Tying Force FV 600 KN : Fa 600 KN
Connection No - C08-C2: Shear Tying Force FV 600 KN : Fa 600 KN
CONNECTION NO - C08-C2
305(MAX)
60 75 75 60 PG 600x220x81 <B111>/
PG 600x220x106 <B113>
100
60
80
305X305X97 UC
80
80
80
80
10
60
NOTES:-
All bolts are M24 Grade 8.8.
All welds are 6mm CFW
All main steel & fittings are S355
SECTIONAL PROPERTIES
Beam (B111) PG 600x220x81
Db := 600mm wb := 220mm Tb := 10mm tb := 10mm
Hole diameter Dh := 26 ⋅ mm
Bolt pitch p := 80 ⋅ mm
Gauge g1 := 75mm
Total no of bolts n = 18
MT ⋅ 200mm
Max. horizontal shear on extreme bolt Fhv := Fhv = 90.7 kN
Ibg
MT ⋅ 75 mm Fv
Max. vertical shear on extreme bolt Fvv := + Fvv = 67.3 kN
Ibg n
2 2
Resultant shear per bolt Fs := Fhv + Fvv Fs = 112.98 kN
k1 + 1
if nc = 3
0.6
k 1 if nc = 1
460
For Bending
Distance from column web to first a := 230mm
line of bolt group
g1
Eccentricity from column web to CG
of bolt group
(
e := a + nc − 1 ⋅
2
) e = 305 mm
Check for shear & bending interaction of incoming beam web section
Db = 600 mm
Depth of beam
2
Av := Db ⋅ tb Av = 6000 mm
Area of beam
2
Avnet := Av − nr ⋅ Dh ⋅ tb Avnet = 4440 mm
Net area of beam
N
pyb = 355
Design strength 2
mm
0.85 ⋅ Av
Plain shear capacity Pvb := 0.7 ⋅ pyb ⋅ Avnet ⋅ Ke355 if Avnet ≤ Pvb = 1213.7 kN
Ke355
Fv kN
Shear per mm FL := FL = 0.577
Lw mm
FL
Size of weld reqd s := s = 3.30 mm
0.7 ⋅ pw
Adopt 6mm CFW
Check for supporting column
N
Design tensile strength pu := 392
2
mm
tf + 2s
β 1 := β 1 = 0.130
dc
2
pu ⋅ tc
Mu := ⋅ 1m Mu = 9.6 kN ⋅ m
4
8Mu
T :=
( )
⋅ ⎡ η + 1.5 ⋅ 1 − β 1
1 − β 1 ⋅ 1m ⎣ 1
( )0.5⎤⎦ T = 309.7 kN
⎛ wc tc ⎞
Shear capacity of stiffener Pvs := 0.6 ⋅ 0.9 ⋅ ts ⋅ ⎜ − − Ls ⋅ pyb Pvs = 244.8 kN
⎝ 2 2 ⎠
Fa
Tie force on stiffener Fas := Fas = 150 kN
4