Three-component primer and bonding agent for Oxydur topping systems, elastomeric floor-
ing systems, Oxydur cements and -laminates

Base: Unsaturated polyester

Description Shelf Life


Oxydur K 425, when fully cured, displays abrasion-proof Oxydur K 425 - Liquid 1:
properties and is resistant to salt solutions, dilute acids, di- When stored in dry and frost-free conditions at temperatures
lute alkalis and many solvents. not exceeding 25°C: 6 months.
Oxydur K 425 yellows under UV light.
Oxydur K 425 - Liquid 2:
Typical Applications When stored in unopened original packages in dry conditions
at temperatures between 10°C (min.) and 25°C (max.): 6
Primer/Bonding Agent for Oxydur topping systems, Oxydur months.
cements and polyester laminates on concrete, steel, Oxydur
Liquid Sheeting and Elastomeric Flooring Systems. Oxydur Hardener 20:
When stored in dry conditions at a temperature of not more
than 25°C: 1 year.
Packaging
Oxydur K 425 is supplied in separate packages, quantities Substrate Requirements
premeasured in correct mixing ratio:
Concrete: Refer to DIN 28052, Parts 2 and 3 as well as
Oxydur K 425 Liquid 1: 3.00 kg can Steuler-KCH-Form Sheets No. 010 and 011.
Oxydur K 425 Liquid 2: 1.50 kg can Steel: Refer to DIN 28053 and DIN 28054 as well as Steuler-
Oxydur Hardener 20: 300 g bag KCH-Form Sheets No. 020 and 021.

Special package sizes available on request.


Moisture
Standard colour: Amber (transparent)
Residual moisture content of the concrete must not exceed 4
Oxydur K 425 is normally supplied only in the transparent %.
grade. Pigmented grades are available on request (please The material has to be protected from any kind of moisture
observe special mixing and application instructions!). (condensation, fog, precipitation or other water source). The
object temperature must have a dew point distance of mini-
mum 3 K, in case of a relative humidity of above 70% of mini-
2 mum 5 K.
Coverage (per m )
When applied to concrete substrates, the amount of material
required depends on the porosity and roughness of the sub- Preparation and Application
strate.
Mixing ratio for Oxydur K 425:
1st coat 0.20 kg
2 parts by weight of Liquid 1
2nd coat 0.15 kg
1 part by weight of Liquid 2.
Two coats are required to obtain a dense, nonporous sur-
The prepared mixture of Liquid 1 and 2 requires 60 - 70 g of
face.
Oxydur Hardener 20 for each kg of the mixture.
When applied to steel substrates:
Pre-mix the full amount of Oxydur Hardener 20 required for
each coat 0.10 to 0.15 kg/m2 the total mixture with a small amount of Oxydur K 425 Liquid
2 until a smooth, lump-free consistency is obtained. Then
The number of coats required depends on the field of appli- add the remaining portion of Liquid 2 and mix thoroughly. Fi-
cation and the type of material to be subsequently applied. nally add the required amount of Oxydur K 425 Liquid 1 and
For more information, please refer to the pertinent Technical remix well.
Information Sheets for such materials.
Do not prepare more mixture than can be applied within the
The film thickness of each coat is 50 to 70 microns. pot life specified for the material.
Make sure that opened packages are used up in full.

We master aggressive media page 1 of 2

Steuler-KCH GmbH ▲ Oberflächenschutz-Systeme ▲ Berggarten 1 ▲ D-56427 Siershahn


Fon: +49 (0) 2623 / 600-907 ▲ Fax: +49 (0) 2623 / 600-794 ▲ E-mail: materials@steuler-kch.de ▲ www.steuler-kch.de
Oxydur K 425 Technical Information 102 Issue 05/2011

Drying Time Curing Time


Between coats, or before proceeding with the application of To support foot traffic: 1.5 to 5 hours, depending on the tem-
other Oxydur material systems, the following minimum drying perature (see also Drying Time above).
times must be allowed for at the following ambient tempera-
tures: To achieve full chemical resistance properties: 24 hours at
20°C.
Minimum drying time at:
5 °C 5.0 hours
20 °C 3.5 hours Cleaning of Equipment
30 °C 1.5 hours
Clean equipment immediately after use with Steuler Cleaner
Oxydur K 425 is a highly reactive system. Therefore, the fol- "Universalreiniger" (see Technical Information Sheet No.
lowing maximum drying times must not be exceeded: 190).

5 °C 36 hours Safety Precautions


20 °C 24 hours
30 °C 12 hours Mix and apply material only in well ventilated areas. Provide
ventilation suited to the conditions when working in pits or
In the event of the maximum drying time being exceeded, or tanks. Do not smoke! Do not expose materials to heat or
in case of exposure to moisture, the area must be reprimed open flame. So not carry out any welding work in the vicinity
before proceeding with the application of any subsequently of the actual work area (welding beads!). Avoid contact with
applied material. First abrade the surface until a uniformly skin or eyes. Wash hands with soap and water; do not clean
dull finish has been obtained, then reprime. the skin with solvents. Use barrier soap and protective
creams on exposed skin areas.
Caution!
Direct sunlight will considerably reduce the drying time. The Refer to Safety Data Sheets!
decision, therefore, if or when to proceed with application
must be made on the basis of the specific conditions prevail-
ing on the site. It may be necessary to perform a bonding
test with the subsequently applied material.

Prevent direct sunlight by adequately sheltering the actual


work area.

Pot Life of Prepared Material


At a material temperature of:
5°C 45 minutes
20°C 20 minutes
30°C 10 minutes
Minimum curing temperature: 5°C.
Maximum curing temperature: 30°C.

The ideal material temperature for application is 20°C.


Oxydur K 425 can, however, also be applied successfully at
other temperatures within the pot life specified.

All information contained in this Product Information sheet is based on the present state of our knowledge and practical experience.
All data are approximate values for guidance only. A legally binding warranty of certain characteristics or the suitability for a certain
purpose of use cannot be derived from this.

The information given in this Product Information sheet is our intellectual property. The Product Information sheet may neither be
copied nor used by unauthorized parties, nor professionally distributed or otherwise made accessible to third parties without our
prior consent.

This issue replaces all previous versions.

We master aggressive media page 2 of 2

Steuler-KCH GmbH ▲ Oberflächenschutz-Systeme ▲ Berggarten 1 ▲ D-56427 Siershahn


Fon: +49 (0) 2623 / 600-907 ▲ Fax: +49 (0) 2623 / 600-794 ▲ E-mail: materials@steuler-kch.de ▲ www.steuler-kch.de

You might also like