Professional Lighting for Hospitals In hospitals this is of extra importance, as it will affect the sizing

of emergency back-up systems.And, because many areas within


A hospital is a very demanding environment for lighting the hospital are in use 24 hours a day, energy efficiency is of
planning.The wide variety of tasks being performed demands greater importance than in other commercial applications.
a number of different lighting solutions. From examination
requirements to clean rooms, EN 12464-1 & I SO 8995
wards, corridors, etc.
The Right Light in the Right Place
New drugs or treatments are
given much attention, while good The two new lighting standards, the European EN 12464-1,
lighting is down on the priority list and the international ISO 8995, calls for the use of more task-
– but we should not under- specific lighting installations and less general-area lighting.
estimate the effects of lighting on
human health and wellbeing. In Planned in the correct way, it is now possible to gain a more
this area there is still plenty of efficient installation for all users while, at the same time,
research to be done before we increasing lighting quality and reducing power consumption.
know the full effects of lighting on Having good knowledge of these standards, Luxo can provide
human beings. However, it is not its proven task-lighting philosophies to numerous new fields of
so much what we do not know application in healthcare facilities. These core values of Luxo
about health and lighting, it is lighting puts the individual into focus. The individual, be it the
what we know. That poor lighting patient, the medical staff or the maintenance crew, is always kept
has adverse effects on wellbeing and health and is therefore in focus through the use of flexible and innovative solutions.
counterproductive to the efficient hospital. Luxo’s integrated tools give us the posssibility to do lighting
planning directly on the plan drawings in computer-aided design
Luxo’s arm-based lighting solutions offer facilities and have the results incorporated in the facilities management
management, very easy maintenance and a high degree of tools for ease of documentation and maintenance.
flexibility. By keeping a few spares, a faulty luminaire may be
replaced in minutes and taken back for maintenance at a Wards, Maternity Wards
suitable location, with minimal interruption of medical
routines. Most of Luxo’s fixed luminaires offer nearly the same Type of Interior, task or activity Em/lux Ra
ease of replacement when fitted with plug and cable. General lighting 100 80
Different electrical and building codes may prevent some of Reading lighting 300 80
these solutions from being applied in certain locations. Simple examinations 300 80
Examination and treatment 1000 90
Luxo, being a total supplier, provide know-how of the Night lighting, observation lighting 5 80
complete lit environment. Our staff are highly trained in Bathrooms and toilets for patients 200 80
designing total lighting solutions. From our point of view, the
ideal situation is when we are allowed to participate in As general lighting, downlighters should be avoided to prevent
planning the lighting from the beginning. This gives us the the patient from having to look directly into the luminaires.
possibility to create a total lighting solution where lighting Using uplighters will eliminate this problem, but care must be
does more than just provide the necessary lux to the task taken in choosing luminaires with wide or highly asymmetric
area. With our expertise we can supply a scheme that light distributions, so that the ceiling is as evenly lit as possible.
harmonises the requirements of the staff with the needs of Trunking systems integrate electrical and communication
the patient. This approach to a well-planned lighting scheme systems with the need for gases in the ward. Often, it is
is not necessarily more expensive than a poorly planned one. requested that lighting is integrated as well. However, for ease
In fact, considerable savings can be made in the long term. of access to these services the trunking needs to be situated
Efficiency also means low energy consumption, which is a approximately 1.4 metres above floor level, but this is not
main consideration in every luminaire we bring from the conducive to the lighting being integrated, as glare would be
drawing board to the end-user. caused by giving a direct view into the uplighter.

Page 1 www.luxo.com
A separate wall-mounted uplighter above the trunking system General Examination Rooms
might prove a better solution. Both the trunking system and
uplighter is then positioned at its optimum height. For reading Type of Interior, task or activity Em/lux Ra
and examination light we strongly recommend an arm-based General lighting 500 90
luminaire fixed to the wall or the furniture. Unlike a reading Examination and treatment 1000 90
light in a trunking system, an arm-based luminaire can be
positioned wherever light is needed. In wards with many beds, Since patients do not stay in an
what one patient does affects others in examination room for a long period
the room. When used as a reading-light, of time, ceiling-mounted luminaires
an arm-based luminaire will not disturb are the best way of reaching the
the patient nearby but will create a 500 lux average.
‘private’ zone. An arm-based luminaire
will also provide the staff with a The required high-colour rendering
supplementary examination lamp. of Ra 90 limits the light sources to
Modern arm-based bed-head luminaires certain T-5 and TC-L tubes. Just like
use highly efficient compact fluorescent in an intensive-care unit, an arm-
lamps with good colour rendering and based examination lamp mounted on a trolley, the wall or on
long lamp life. the ceiling will add the necessary light for examinations and
treatment. A halogen examination lamp is best suited due to
High-frequency ballasts provide the users with flicker-free its good colour rendering and focused beam. By using a
lighting while extending lamp life even more and lowering multibeam examination/procedure light, shadows are
power consumption. Dimming may also prove beneficial in eliminated.
lighting the ward. Smooth, even surfaces and covered arms
make cleaning easy. Rooms for General Use

Intensive-care Unit Type of Interior, task or activity Em/lux Ra


Waiting rooms 200 80
Type of interior, task or activity Em/lux Ra Corridors during the day 200 80
General lighting 100/400* 90 Corridors during the night 50 80
Simple examinations 300/400* 90 Day rooms 200 90
Examination and treatment 1,000 90 Staff office
Night watch 20 90 500
80
*UK. CIBSE LG2:1989/CIBSE Code for Interior Lighting: 1994

Corridors
In the intensive-care unit, just like the ward, uplighters are the Illuminating corridors often requires
best choice for general lighting as they provide evenly energy efficiency and a high degree of
distributed luminances. If specified correctly they will even functionality. Corridor lighting has the
cover the need for simple examinations giving a shadow-free prime objective of illuminating
light. A high-colour rendering of minimum Ra 90 limits the ‘transportation’ areas evenly. This can
types of lamps suitable to certain T-5 and TC-L tubes. achieved by means of wall-mounted
luminaires that ‘wash’ the wall with light, by means of ceiling-
For examinations, a separate arm-based examination lamp is mounted direct-light luminaires or other solutions depending
the best choice. Unlike a reading-lamp it uses a tungsten on the individual design and construction of the corridors. For
halogen lamp for maximum colour rendering and intensity. An night-time use, corridor lighting should be dimmable.
examination lamp might be ceiling-mounted, wall-mounted or
mounted on a trolley for maximum flexibility. It also has a heat Offices
filter and front glass to prevent heat from the high-intensity
lamp being projected onto the examination area. Besides medical lighting, office lighting has been Luxo’s strength

Page 2 www.luxo.com
for decades. Luxo is devoted to ergonomically correct and Denmark
Tel: +45 44 200 700 Fax: +45 44 200 730
energy efficient office lighting. At Luxo, we recommend a E-mail: office@luxo.dk
http://dk.luxo.com/
lighting solution for the offices – and especially where Luxo-Deutchland GmbH
Daimlerring 25
computers are part of the interior – that consist of either well- D-31135 Hildesheim
Postfach 100942
shaded downlighters placed correctly to avoid glare or indirect D-31109 Hildesheim
Germany
lighting in combination with an asymmetric task light. This Tel.: +49 5121 70 601-0 Fax: +49 5121 529 10 / 5 29 22
E-mail: office@luxo.de
solution is both ergonomically http://de.luxo.com/
correct and individually adapted Luxo Export
and takes into account the need Enebakkveien 117
PO Box 60
for no-glare lighting and energy- Manglerud NO-0612
Norway
conserving solutions. Tel: +47 22 57 40 00 Fax: +47 22 57 29 93
E-mail: export@luxo.no, export@luxo.se
http://no.luxo.com/

Waiting Rooms Luxo Finland Oy


Mäkelänkatu 84
FI-00610 Helsinki
Finland
In waiting-room areas, the Tel: +358 (0)9 720 64 00 Fax: +358 (0)9 720 640 70
lighting plays a major role in E-mail: office@luxo.fi
http://fi.luxo.com/
creating a relaxing and
Luxo Lamp Ltd/Les Lampes Luxo Ltée
soothing atmosphere that is more ‘homely’. The lighting 1957 Le Chatelier Laval
Québec H7L 5B3
scheme can provide a different ‘feel’ to varying parts of the Canada
Tel: +1 450 688 58 96 Fax: +1 450 681 71 05
space. There may be bright zones or there may be more E-mail: office@luxo.ca
http://www.luxo.ca
secluded zones. The important point is that the lighting can
Luxo Nederland BV
be used as a tool to provide these Amnesty Internationalweg 25
NL-3318 AZ Dordrecht
different effects without necessarily Postbus 58
having to alter the physical attributes. NL-3300 AB Dordrecht
The Netherlands
The effects can even be manipulated Tel:+31 78 617 2748 Fax:+31 78 617 2794
E-mail: info@luxo.nl
via lighting controls according to the http://nl.luxo.com/

varying individual needs, daylight Luxo Norge AS


Enebakkveien 117
availability or simply by occupancy. PO Box 60
Manglerud NO-0612
Norway
Tel: +47 22 57 40 00 Fax: +47 22 57 29 93
Total Lighting Environment E-mail: ordrekontor@luxo.no
http://no.luxo.com/

Luxo can provide complete balanced Luxo Prosjekt AS


Enebakkveien 117 P.O.Box 60 Manglerud NO-0612
lighting solutions with the needs of patients, staff and Tel: +47 22 57 80 60 Fax: +47 22 57 80 61
E-mail: post@luxoprosjekt.no http://prosjekt.luxo.com/
maintenance team in focus at all times. This approach
Luxo Schweiz GmbH
facilitates a quick recovery through a well-lit, comfortable and Oberebenestrasse 67 CH-5620 Bremgarten
Tel: +41 56 633 88 28 Fax:+41 56 633 99 04
effective environment. E-mail: office@luxo.ch http://ch.luxo.com/

Luxo Sverige AB
Kråketorpsgatan 10A
New lighting standards open up to more task-specific lighting S- 431 53 Mölndal
Sweden
installations and less general-area lighting.The result is a lower Tel: +46 31 746 51 00 Fax:+46 31 87 15 25
installed load, fewer luminaires and a better-lit environment. E-mail: info@luxo.se
http://se.luxo.com/

Luxo UK Ltd.
Luxo Group Connect House, 21 Willow Lane
Mitcham, Surrey CR4 4NA
Luxo Corporation United Kingdom
200 Clearbrook Road Tel: +44 (0)8702 404012 Fax : +44 (0)8702 404013
Elmsford, NY 10523 E-mail: office@luxo.co.uk
United States http://uk.luxo.com/
Tel: +1 914 345 0067 Fax: +1 914 345 0068
E-mail: office@luxous.com
http://www.luxous.com

Luxo Danmark AS
Baltorpbakken 5-7
DK-2750 Ballerup

Page 3 www.luxo.com

You might also like