Data sheet

The configuration is inconsistent; this printout is possibly


incorrect.

Customer item no.:


Communication dated: Number: ES 3528249
Doc. no.: Item no.: 100
Quantity: 1 Date: 24/03/2015
Page: 1 / 5

KRTK 65-252/44UKG-D IE3 Version no.: 1

Operating data
Requested flow rate 54.36 m³/h Actual flow rate 54.36 m³/h
Requested developed head 12.50 m Actual developed head 12.50 m
Pumped medium Water Efficiency 52.0 %
Clean water Power absorbed 3.57 kW
Not containing chemical and Pump speed of rotation 1487 rpm
mechanical substances which NPSH required 3.19 m
affect the materials Permissible operating 10.00 bar.g
Ambient air temperature 20.0 °C pressure
Fluid temperature 20.0 °C Discharge press. 1.23 bar.g
Fluid density 998 kg/m³

Fluid viscosity 1.00 mm²/s Design Single system 1 x 100 %


Suction pressure max. 0.00 bar.g Performance test No
Max. power on curve 3.57 kW Tolerances to ISO 9906 Class
Shutoff head 20.38 m 3B; below 10 kW acc. to
paragraph 4.4.2

Design
Design Close-coupled submersible Material code SIC/SIC/NBR
Orientation Vertical Impeller type Multivane radial flow impeller
Suction flange pump EN 1092-2 / DN 80 / drilled (K)
according to(DN1) DIN 2501 / ISO 7005 Wear ring Casing wear ring
Discharge flange pump DN 65 / PN 16 / Drilled Impeller diameter 241.0 mm
according to(DN2) according to EN 1092-2 Free passage size 32.0 mm
Suction nozzle drilled acc. to DIN2501 with tapped blind holes Direction of rotation from drive Clockwise
Shaft seal 2 mech. seals in tandem Color Ultramarine blue (RAL 5002)
arrangement with oil reservoir KSB-blue
Manufacturer KSB
Type MG

Driver, accessories
Driver type Electric motor Temperature sensor PTC resistor
Model (make) KSB Motor winding 400 / 690 V
Motor const. type KSB Sub. motor Number of poles 4
Operating mode S1, non submerged operation Starting mode Direct/Star-delta possible
Efficiency class Efficiency class IE3 acc. to Connection mode Delta
IEC60034-30-1 Motor cooling method Surface cooling
Frequency 50 Hz Motor version U
Rated voltage 400 V Cable design Rubber hose
Rated power P2 4.00 kW Cable entry Sealed along entire length
Available reserve 12.16 % Power cable S1BN8-F 12G1.5
Rated current 8.1 A Number of power cables 1
Starting current ratio 9.5 Moisture sensor With
Insulation class H according IEC 34-1 Cable length 10.00 m
Motor enclosure IP68
Cos phi at 4/4 load 0.80
Motor efficiency at 4/4 load 89.1 %
Data sheet
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 3528249
Doc. no.: Item no.: 100
Quantity: 1 Date: 24/03/2015
Page: 2 / 5

KRTK 65-252/44UKG-D IE3 Version no.: 1

Materials G
Notes O-Ring (412) Nitrile rubber NBR
General criteria for a water analysis: pH-value >= 7; chloride Casing wear ring (502.1) Grey cast iron EN-GJL-250
content (Cl) <=250 mg/kg. Chlorine (Cl2) <=0.6 mg/kg. Motor housing (811) Grey cast iron EN-GJL-250
Pump casing (101) Grey cast iron EN-GJL-250 Motor cable (824) Chloroprene rubber
Discharge cover (163) Grey cast iron EN-GJL-250 Screw (900) CrNiMo steel A4
Shaft (210) Chrome steel 1.4021+QT800
Impeller (230) Grey cast iron EN-GJL-250

Nameplates
Nameplates language International Duplicate nameplate With

Installation parts
Installation type Dry installation Material concept G
Scope of supply Pump with installation parts Inlet elbow size / DN0 DN 80 / 80
Installation variant Dry
Performance curve
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 3528249
Doc. no.: Item no.:100
Quantity: 1 Date: 24/03/2015
Page: 3 / 5

KRTK 65-252/44UKG-D IE3 Version no.: 1

Qmin

Qmin
Total developed head

20

[m]

Qmax 256.0
10
Qmin 241.0

140.0
0
0 10 [m³/h] 20 30 40 50 60 70 80

4
NPSH req.

[m]

0 10 [m³/h] 20 30 40 50 60 70 80

50
Efficiency

[%]

0
0 10 [m³/h] 20 30 40 50 60 70 80
3.8

[kW]
Power Input

3.0

2.2
0 10 [m³/h] 20 30 40 50 60 70 80
Flow

Curve data
Speed of rotation 1487 rpm Efficiency 52.0 %
Fluid density 998 kg/m³ Power absorbed 3.57 kW
Viscosity 1.00 mm²/s NPSH required 3.19 m
Flow rate 54.36 m³/h Curve number K43310
Requested flow rate 54.36 m³/h Effective impeller diameter 241.0 mm
Total developed head 12.50 m Acceptance standard Tolerances to ISO 9906
Requested developed head 12.50 m Class 3B; below 10 kW
acc. to paragraph 4.4.2
Installation plan
The configuration is inconsistent; this printout is possibly
incorrect.

Customer item no.:


Communication dated: Number: ES 3528249
Doc. no.: Item no.:100
Quantity: 1 Date: 24/03/2015
Page: 4 / 5

KRTK 65-252/44UKG-D IE3 Version no.: 1

481

267
18

220
125

175 175

180 125 220


18

240 225

360

200

Drawing is not to scale Dimensions in mm


Installation plan
The configuration is inconsistent; this printout is possibly incorrect.

Customer item no.:


Communication dated: Number: ES 3528249
Doc. no.: Item no.:100
Quantity: 1 Date: 24/03/2015
Page: 5 / 5

KRTK 65-252/44UKG-D IE3 Version no.: 1

Motor Connections
Motor manufacturer KSB Inlet elbow size / DN0 DN 80 / 80
Motor size 4K Suction flange pump EN 1092-2 / DN 80 / drilled
Motor power 4.00 kW according to(DN1) DIN 2501 / ISO 7005
Number of poles 4 Discharge flange pump DN 65 / PN 16 / Drilled
Speed of rotation 1485 rpm according to(DN2) according to EN 1092-2
Suction nozzle drilled acc. to DIN2501 with tapped blind holes

Weight net
Pump, Motor, Cable 174 kg
Total 174 kg
Connect pipes without stress or strain! For auxiliary connections see
Dimensional tolerances for shaft axis height: DIN 747 separate drawing.
Dimensions without tolerances, middle tolerances to: ISO 2768-m
Connection dimensions for pumps: EN735
Dimensions without tolerances - welded parts: ISO 13920-B
Dimensions without tolerances - gray cast iron parts: ISO 8062-CT9