Test Report

Model S-20
Pressure range: 0 ... 400 bar rel.
Signal: 4 ... 20 mA
Power supply: 12 ... 35 V
Pin assignment: U+:1 U-:3
Non-linearity: 0.125% BFSL
Product No: 14254229
Serial No.: 1A00NHHZQJM
Pressure Signal Error
[bar] [mA] [%]
0.0000 4.0011 0.0069
100.0000 8.0084 0.0525
200.0000 12.0145 0.0906
300.0000 16.0163 0.1020
400.0000 20.0027 0.0167
Max. Non-linearity: -0.05%
Test person: Ronny Jäger
8A

WIKA Alexander Wiegand SE & Co. KG Phone: +49 9372 132/0


Alexander-Wiegand-Str. 30 Fax Inland: +49 9372 132/406
63911 Klingenberg E-Mail: info@wika.de
Germany Internet: www.wika.de
Test Report
Model S-20
Pressure range: 0 ... 400 bar rel.
Signal: 4 ... 20 mA
Power supply: 12 ... 35 V
Pin assignment: U+:1 U-:3
Non-linearity: 0.125% BFSL
Product No: 14254229
Serial No.: 1A00NJYEA33
Pressure Signal Error
[bar] [mA] [%]
0.0000 4.0021 0.0132
100.0000 8.0093 0.0580
200.0000 12.0137 0.0855
300.0000 16.0158 0.0986
400.0000 20.0030 0.0188
Max. Non-linearity: -0.05%
Test person: Ronny Jäger
8A

WIKA Alexander Wiegand SE & Co. KG Phone: +49 9372 132/0


Alexander-Wiegand-Str. 30 Fax Inland: +49 9372 132/406
63911 Klingenberg E-Mail: info@wika.de
Germany Internet: www.wika.de