1. Which of the following shall be the allowable stress to be used at 10. Determine the anchorage slip loss
top fiber considering compression? a. 21 MPa c. 36 MPa
a. 16 MPa c. 18 MPa b. 58 MPa d. 8 MPa
b. 24 MPa d. 2.85 MPa e. NOTA 11. Using K= 0.0033 and μ = 0.25, determine the friction loss.
2. Which of the following gives the maximum live load that the beam a. 109 MPa c. 41 MPa
could carry considering top fiber stress only? b. 12 MPa d. 163 MPa e. NOTA
a. 10.6 kN/m c. 8.4 kN/m 12. Determine the initial prestressing force, Pi.
b. 9.2 kN/m d. 12.7 kN/m e. NOTA a. 1198 kN c. 1346 kN
3. Which of the following shall be the allowable stress to be used at b. 865 kN d. 1520 kN e. NOTA
bottom fiber considering tension? 13. Determine the shrinkage loss after 30 days (Ksh = 0.58)
a. 3.16 MPa c. 20 MPa a. 25 MPa c. 67 MPa
b. 2.85 MPa d. 2.53 MPa e. NOTA b. 45 MPa d. 72 MPa e. NOTA
4. Which of the following gives the maximum live load that the beam
could carry considering bottom fiber stress only? Situation 4:
a. 8.5 kN/m c. 4.2 kN/m Design, for service load condition, a post-tensioned T-section to carry
b. 10.5 kN/m d. 6.6 kN/m e. NOTA a total service load of 15 kN/m (not including self-weight) on a 12m
simply supported span. Design the section for zero-tension, for fci =
Situation 2: 12.5MPa and fc = 11.0MPa at transfer and service conditions,
A 19.8m simply supported beam carries a superimposed dead load of respectively. Assume that the sectional properties are bf = 0.5h, hf =
1.46 kN/m and a service live load of 16.1 kN/m. The properties of an I- 0.2h, and bw = 0.25h and use multiples of 50mm for h. Use WSD/ASD
beam section to be investigated is shown below. The beam is method. Assume the self-weight of the beam is 6.0 kN/m and the
reinforced with 13 numbers of 7-wire 1/2” diameter (99 mm2) Grade following prestressing data:
270 tendons (fpu = 1860 MPa and fpy = 1580 MPa) and 4-12mm Grade
60 (414 MPa) non-prestressed reinforcement at tension side only. Use
34.5 MPa concrete.
Section Properties:
Ac = 243,225 mm2 ct = 537.5mm
b = 457 mm d = 955 mm
dp = 918.5 mm r2 = 120, 968 mm2
e (centerline) = 381 mm Ec = 27,800 MPa Eps = 193 GPa