SERIES 4300 Vertical In-Line: 5 0 HZ (I Ec / D I N) 20 0 - 3 3 0

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SERIES 4300 | VERTIC AL IN – LIN E File No: ÛÚáÜÛÜ/%ı

Date: $(. ÙÞ 201Ü

5 0 Hz (IEC / DI N) | 20 0 –33 0 | s u b m i t t a l
Supersedes: new
Date: new

Job: Representative:

Ordered by: Date:

Engineer: Submitted by: Date:

Contractor: Approved by: Date:

pum p d e s i g n data moto r d e s i g n data


)ÚĪ) Ī*/'*-Ü Ī !ÜĪ kW: rpm:
Capacity: mC/h (L/s) Head: m (ft) Frame size: Enclosure:
Liquid: Viscosity: Volts: Hertz: 50 Hz
'*,./,ÜĪ °c (°f)Ī *#ŔĪ!,0#.3ÜĪ Efficiency: … ie 1 … ie 2 … ie 3
Suction: 200 mm (8") Discharge: 200 mm (8") Flange size: Phase:

m a x imum pum p o pe r at i n g co n d it i o n s m ec h a n i c a l s e a l d e s i g n data


pn 16 ĪŔ&Ī(/',Ī43.50 for standard mechanical seal
12 bars at 60°c (175 psig at 140°f) details as indicated below
7 bars at 149°c (100 psig at 300°f) a r m s t r o n g s e a l r ef er en ce n u m b er :
pn 25 … c1 (a) … Others:
25 bars at 38°c (363 psig at 100°f)
19 bars at 149°c (275 psig at 300°f)
s e a l data o p t i o n s
àĪĪŔ&Ī()ÚĪ43.50Ī ),Ī'2#'/'Ī-&Ī)*,.#(!Ī)(#.#)(-Ú
à )/*&#(!Ī!/,Ī÷().Ī-")1(øĪ#-Ī-/**&#Ú
àĪ)&,(Ī) Ī±0.125" (±3 mm) should be used
à For exact installation data please write factory for
,.# #Ī#'(-#)(-Ú
à See performance curves on page 3Ú
à Pump equipped with casing drain plug and ¼" npt suction and o p t i o n a l eq u i pm e n t
#-",!Ī!/!Ī*),.-ÚĪ
ĪŔ&Ī()ÚĪ43.50 for environmental accessories

m at e r i a l s o f co n s t r u c t i o n

ansi flange rating pn 16 pn 25


Construction … bf … ai … dbf … di
Casing Cast iron Cast iron Ductile iron Ductile iron
Impeller Bronze Cast iron Bronze Cast iron

Flush line: Braided stainless steel


Pump shaft: 416 stainless steel
Coupling: High tensile aluminum
Gasket:Ī)(Ŕ(ĪŔ,
submittal Series 4300
200-330 Vertical In–Line pump

102

full load assembly


motor kW current (a) starting current (a) dimensions mm(inches) weight
star delta direct on
3000 1500 380-415v (sd) line (dol) e p r xy kg (lbs)

160M — 11 21.9 50.4 168.6 208 (8.19) 315 (12.40) 250 (9.84) 839 (33.03) 451.0 (994)

160L — 15 29.6 68.1 227.9 208 (8.19) 315 (12.40) 250 (9.84) 909 (35.79) 491.0 (1082)

180M — 18.5 36.3 94.4 304.9 248 (9.76) 316 (12.44) 325 (12.80) 909 (35.79) 514.0 (1133)

180L — 22 41.8 92.0 313.5 255 (10.04) 350 (13.78) 325 (12.80) 1007 (39.65) 547.0 (1206)

200L — 30 58.0 139.2 435.0 275 (10.83) 390 (15.35) 325 (12.80) 1083 (42.64) 614.0 (1354)

280S 75 — 135 324.2 1012.5 472 (18.58) 580 (22.83) 375 (14.76) 1387 (54.61) 934.0 (2059)

280M 90 — 161 386.4 1207.5 472 (18.58) 580 (22.83) 375 (14.76) 1396 (54.96) 948.0 (2090)

315S 110 — 196 470.4 1470.0 530 (20.87) 657 (25.87) 375 (14.76) 1569 (61.77) 1181.0 (2604)

315M 132 — 232 556.8 1740.0 530 (20.87) 657 (25.87) 375 (14.76) 1569 (61.77) 1290.0 (2844)

315M 160 — 281 702.5 2163.7 530 (20.87) 657 (25.87) 375 (14.76) 1569 (61.77) 1414.0 (3117)

pump dimensions
mm (inches)

b c d s sd t
305 (12.00) 248 (9.75) 483 (19.00) 584 (23.00) 1067 (42.00) 252 (9.94)
Series 4300 s u b m it ta l
Vertical In–Line pump 8 × 8 × 13

103

series 43 0 0 performance curves

Curve number
3000 rpm pt664-1-255-3000
(459.3) 140 Series
4300
(393.7) 120 292 mm 49 Size
63 72
275 mm 78 200–330
81
(328.1) 100 260 mm 84 rpm
85
head m (ft)

254 mm 3000
84
(262.5) 80 81 bhp based on shown
78% 250 kW Fluid’s sp. gr.
(196.9) 60 200 kW Availability
72%
4300 all ratings
(131.2) 40 160 kW
Performance
132 kW guaranteed only at
(65.6) 20 110 kW operating point
NPSHr
indicated.
(0.0) 0
0 200 400 600 800 1000
Curve shown for
0.00 55.56 111.12 166.68 222.25 277.81 clear, cold water
– sp. gr. 1.000
flow m3/h (L/s)

335 mm 49 Curve number


63 pt664-1-0-1500
72 1500 rpm
(114.8) 35 78
305 mm 81 Series
84 4300
(98.4) 30 85
Size
84
275 mm 200–330
(82.0) 25 81
rpm
head m (ft)

45 kW 1500
78%
(65.6) 20 254 mm 37 kW bhp based on shown
Fluid’s sp. gr.
(49.2) 15 72% 30 kW Availability
4300 all ratings
(32.8) 10 22 kW
18.5 kW Performance
N guaranteed only at
P 15 kW
(16.4) 5 S operating point
H NPSHr
r
indicated.
(0.0) 0 Curve shown for
0 100 200 300 400 500 600 700
0.00 27.78 55.56 83.34 111.12 138.90 166.68 194.46
clear, cold water
– sp. gr. 1.000
flow m3/h (L/s)

Performance curves are for reference only.


Confirm current performance data with Armstrong ACE Online selection software.
toronto
23 bertrand avenue
toronto, ontario
canada
m1l 2p3
+1 416 755 2291

buffalo
93 east avenue
north tonawanda, new york
u.s.a.
14120 -6594
+1 716 693 8813

birmingham
heywood wharf, mucklow hill
halesowen, west midlands
united kingdom
b62 8dj
+44 (0) 8444 145 145

manchester
wenlock way
manchester
united kingdom
m12 5jl
+44 (0) 8444 145 145

bangalore
#59, first floor, 3rd main
margosa road, malleswaram
bangalore, india
560 003
+91 (0) 80 4906 3555

shanghai
no. 1619 hu hang road, xi du township
feng xian district, shanghai
p.r.c.
201401
+86 21 3756 6696

a r m s t r o n g f lu i d t e c h n o lo g y
established 1934 a r m s t r o n g f lu i d t e c h n o lo g y. c o m
tm

You might also like