Date:

21/10/2019

Project 0
Project 0 21/10/2019

Project 0 / Content

Content
Project 0
Site 1
Building 1
Storey 1
balcony
Summary................................................................................................................................................................................................. 4
Luminaire layout plan.............................................................................................................................................................................. 5
Workplane (balcony) / Perpendicular illuminance (adaptive).................................................................................................................. 6
bath
Summary................................................................................................................................................................................................. 7
Luminaire layout plan.............................................................................................................................................................................. 8
Workplane (bath) / Perpendicular illuminance (adaptive)........................................................................................................................9
bed room 3
Summary............................................................................................................................................................................................... 12
Luminaire layout plan............................................................................................................................................................................ 13
Workplane (bed room 3) / Perpendicular illuminance (adaptive).......................................................................................................... 14
bed room1
Summary............................................................................................................................................................................................... 18
Luminaire layout plan............................................................................................................................................................................ 19
Workplane (bed room1) / Perpendicular illuminance (adaptive)........................................................................................................... 20
Bed room2
Summary............................................................................................................................................................................................... 24
Luminaire layout plan............................................................................................................................................................................ 25
Workplane (Bed room2) / Perpendicular illuminance (adaptive)........................................................................................................... 26
corridor
Summary............................................................................................................................................................................................... 30
Luminaire layout plan............................................................................................................................................................................ 31
Workplane (corridor) / Perpendicular illuminance (adaptive)................................................................................................................ 32
corridor1
Summary............................................................................................................................................................................................... 34
Luminaire layout plan............................................................................................................................................................................ 35
Workplane (corridor1) / Perpendicular illuminance (adaptive).............................................................................................................. 36
corridor2
Summary............................................................................................................................................................................................... 37
Luminaire layout plan............................................................................................................................................................................ 38
Workplane (corridor2) / Perpendicular illuminance (adaptive).............................................................................................................. 39
dining
Summary............................................................................................................................................................................................... 43
Luminaire layout plan............................................................................................................................................................................ 44
Workplane (dining) / Perpendicular illuminance (adaptive)................................................................................................................... 45
kitchen
Summary............................................................................................................................................................................................... 49
Luminaire layout plan............................................................................................................................................................................ 50
Workplane (kitchen) / Perpendicular illuminance (adaptive)................................................................................................................. 51
master bath
Summary............................................................................................................................................................................................... 55
Luminaire layout plan............................................................................................................................................................................ 56
Workplane (master bath) / Perpendicular illuminance (adaptive)..........................................................................................................57
reception
Summary............................................................................................................................................................................................... 60
Luminaire layout plan............................................................................................................................................................................ 61
Workplane (reception) / Perpendicular illuminance (adaptive)..............................................................................................................62
Room 7
Summary............................................................................................................................................................................................... 66
shower
Summary............................................................................................................................................................................................... 67
Luminaire layout plan............................................................................................................................................................................ 68

Page 2
Project 0 21/10/2019

Project 0 / Content

Workplane (shower) / Perpendicular illuminance (adaptive)................................................................................................................. 69


toilet
Summary............................................................................................................................................................................................... 73
Luminaire layout plan............................................................................................................................................................................ 74
Workplane (toilet) / Perpendicular illuminance (adaptive)..................................................................................................................... 75

Page 3
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Summary

balcony

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (balcony) Perpendicular illuminance (adaptive) [lx] * 99.8 (≥ 100) 63.7 120 0.64 0.53
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 5.17 W/m² = 5.18 W/m²/100 lx (Floor area of room 7.74 m²)

Consumption: 77 kWh/a of maximum 300 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 4
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Luminaire layout plan

balcony

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 5.699 0.525 2.800 0.70
2 1.900 0.525 2.800 0.70

Page 5
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / balcony / Workplane (balcony) / Perpendicular illuminance (adaptive)

Workplane (balcony) / Perpendicular illuminance (adaptive)

Workplane (balcony): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 99.8 lx (Target: ≥ 100 lx), Min: 63.7 lx, Max: 120 lx, Min/average: 0.64, Min/max: 0.53
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 50

False colours [lx]

Scale: 1 : 50

Value grid [lx]

Scale: 1 : 50

Page 6
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Summary

bath

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (bath) Perpendicular illuminance (adaptive) [lx] * 354 (≥ 300) 273 414 0.77 0.66
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L1160 1xLED48S/830 4799 45.0 106.6

Total via all luminaires 9598 90.0 106.6

Lighting power density: 16.91 W/m² = 4.78 W/m²/100 lx (Floor area of room 5.32 m²)

Consumption: 170 kWh/a of maximum 200 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 7
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Luminaire layout plan

bath

Philips SM150C L1160 1xLED48S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.688 1.182 2.800 0.70
2 0.563 1.182 2.800 0.70

Page 8
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Workplane (bath) / Perpendicular illuminance (adaptive)

Workplane (bath): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 354 lx (Target: ≥ 300 lx), Min: 273 lx, Max: 414 lx, Min/average: 0.77, Min/max: 0.66
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 9
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 10
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bath / Workplane (bath) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 11
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Summary

bed room 3

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (bed room 3) Perpendicular illuminance (adaptive) [lx] * 207 (≥ 200) 136 250 0.66 0.54
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 Philips - SM531C L1130 1 xLED25S/830 NOC 2499 26.0 96.1

Total via all luminaires 9996 104.0 96.1

Lighting power density: 5.57 W/m² = 2.69 W/m²/100 lx (Floor area of room 18.67 m²)

Consumption: 410 kWh/a of maximum 700 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 12
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Luminaire layout plan

bed room 3

Philips SM531C L1130 1 xLED25S/830 NOC

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 3.004 1.166 2.800 0.70
2 3.004 3.499 2.800 0.70
3 1.001 1.166 2.800 0.70
4 1.001 3.499 2.800 0.70

Page 13
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Workplane (bed room 3) / Perpendicular illuminance (adaptive)

Workplane (bed room 3) / Perpendicular illuminance (adaptive)

Workplane (bed room 3): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 207 lx (Target: ≥ 200 lx), Min: 136 lx, Max: 250 lx, Min/average: 0.66, Min/max: 0.54
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 14
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Workplane (bed room 3) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 15
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Workplane (bed room 3) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 16
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room 3 / Workplane (bed room 3) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 17
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Summary

bed room1

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (bed room1) Perpendicular illuminance (adaptive) [lx] * 220 (≥ 200) 144 266 0.65 0.54
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 Philips - SM531C L1130 1 xLED25S/830 NOC 2499 26.0 96.1

Total via all luminaires 9996 104.0 96.1

Lighting power density: 6.16 W/m² = 2.80 W/m²/100 lx (Floor area of room 16.88 m²)

Consumption: 410 kWh/a of maximum 600 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 18
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Luminaire layout plan

bed room1

Philips SM531C L1130 1 xLED25S/830 NOC

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 0.938 3.375 2.800 0.70
2 0.938 1.125 2.800 0.70
3 2.813 3.375 2.800 0.70
4 2.813 1.125 2.800 0.70

Page 19
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Workplane (bed room1) / Perpendicular illuminance (adaptive)

Workplane (bed room1) / Perpendicular illuminance (adaptive)

Workplane (bed room1): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 220 lx (Target: ≥ 200 lx), Min: 144 lx, Max: 266 lx, Min/average: 0.65, Min/max: 0.54
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 20
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Workplane (bed room1) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 21
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Workplane (bed room1) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 22
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / bed room1 / Workplane (bed room1) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 23
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Summary

Bed room2

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (Bed room2) Perpendicular illuminance (adaptive) [lx] * 224 (≥ 300) 149 274 0.67 0.54
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 Philips - SM531C L1130 1 xLED25S/830 NOC 2499 26.0 96.1

Total via all luminaires 9996 104.0 96.1

Lighting power density: 6.35 W/m² = 2.83 W/m²/100 lx (Floor area of room 16.39 m²)

Consumption: 410 kWh/a of maximum 600 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 24
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Luminaire layout plan

Bed room2

Philips SM531C L1130 1 xLED25S/830 NOC

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 2.813 1.095 2.800 0.70
2 2.813 3.285 2.800 0.70
3 0.938 1.095 2.800 0.70
4 0.938 3.285 2.800 0.70

Page 25
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Workplane (Bed room2) / Perpendicular illuminance (adaptive)

Workplane (Bed room2) / Perpendicular illuminance (adaptive)

Workplane (Bed room2): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 224 lx (Target: ≥ 300 lx), Min: 149 lx, Max: 274 lx, Min/average: 0.67, Min/max: 0.54
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 26
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Workplane (Bed room2) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 27
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Workplane (Bed room2) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 28
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Bed room2 / Workplane (Bed room2) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 29
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Summary

corridor

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (corridor) Perpendicular illuminance (adaptive) [lx] * 108 (≥ 100) 83.7 127 0.78 0.66
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

1 Philips - SM531C L1130 1 xLED25S/830 NOC 2499 26.0 96.1

Total via all luminaires 2499 26.0 96.1

Lighting power density: 5.27 W/m² = 4.87 W/m²/100 lx (Floor area of room 4.93 m²)

Consumption: 50 kWh/a of maximum 200 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 30
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Luminaire layout plan

corridor

Philips SM531C L1130 1 xLED25S/830 NOC

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.281 0.966 2.800 0.70

Page 31
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

Workplane (corridor) / Perpendicular illuminance (adaptive)

Workplane (corridor): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 108 lx (Target: ≥ 100 lx), Min: 83.7 lx, Max: 127 lx, Min/average: 0.78, Min/max: 0.66
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 25

Page 32
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor / Workplane (corridor) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Value grid [lx]

Scale: 1 : 25

Page 33
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor1 / Summary

corridor1

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (corridor1) Perpendicular illuminance (adaptive) [lx] * 129 (≥ 100) 97.0 150 0.75 0.65
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 5.92 W/m² = 4.58 W/m²/100 lx (Floor area of room 6.76 m²)

Consumption: 77 kWh/a of maximum 250 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 34
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor1 / Luminaire layout plan

corridor1

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.337 0.644 2.800 0.70
2 4.015 0.652 2.800 0.70

Page 35
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor1 / Workplane (corridor1) / Perpendicular illuminance (adaptive)

Workplane (corridor1) / Perpendicular illuminance (adaptive)

Workplane (corridor1): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 129 lx (Target: ≥ 100 lx), Min: 97.0 lx, Max: 150 lx, Min/average: 0.75, Min/max: 0.65
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 50

False colours [lx]

Scale: 1 : 50

Value grid [lx]

Scale: 1 : 50

Page 36
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Summary

corridor2

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (corridor2) Perpendicular illuminance (adaptive) [lx] * 122 (≥ 100) 52.3 149 0.43 0.35
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 4.24 W/m² = 3.48 W/m²/100 lx (Floor area of room 9.43 m²)

Consumption: 77 kWh/a of maximum 350 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 37
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Luminaire layout plan

corridor2

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.886 1.185 2.800 0.70
2 1.885 3.557 2.800 0.70

Page 38
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Workplane (corridor2) / Perpendicular illuminance (adaptive)

Workplane (corridor2) / Perpendicular illuminance (adaptive)

Workplane (corridor2): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 122 lx (Target: ≥ 100 lx), Min: 52.3 lx, Max: 149 lx, Min/average: 0.43, Min/max: 0.35
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 39
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Workplane (corridor2) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 40
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Workplane (corridor2) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 41
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / corridor2 / Workplane (corridor2) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 42
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Summary

dining

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (dining) Perpendicular illuminance (adaptive) [lx] * 258 (≥ 200) 147 321 0.57 0.46
Height: 0.800 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

6 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 14400 120.0 120.0

Lighting power density: 4.59 W/m² = 1.78 W/m²/100 lx (Floor area of room 26.17 m²)

Consumption: 470 kWh/a of maximum 950 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 43
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Luminaire layout plan

dining

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 2.717 1.227 2.800 0.70
2 2.717 3.682 2.800 0.70
3 2.717 6.137 2.800 0.70
4 0.906 1.227 2.800 0.70
5 0.906 3.682 2.800 0.70
6 0.906 6.137 2.800 0.70

Page 44
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Workplane (dining) / Perpendicular illuminance (adaptive)

Workplane (dining) / Perpendicular illuminance (adaptive)

Workplane (dining): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 258 lx (Target: ≥ 200 lx), Min: 147 lx, Max: 321 lx, Min/average: 0.57, Min/max: 0.46
Height: 0.800 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 45
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Workplane (dining) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 50

Page 46
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Workplane (dining) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 50

Page 47
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / dining / Workplane (dining) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 50

Page 48
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Summary

kitchen

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (kitchen) Perpendicular illuminance (adaptive) [lx] * 543 (≥ 500) 333 646 0.61 0.52
Height: 1.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

4 DIALux - WT060C LED 36S840 PSU L1200 #1 3600 33.0 109.1

Total via all luminaires 14400 132.0 109.1

Lighting power density: 13.27 W/m² = 2.44 W/m²/100 lx (Floor area of room 9.95 m²)

Consumption: 810 kWh/a of maximum 350 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 49
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Luminaire layout plan

kitchen

DIALux WT060C LED 36S840 PSU L1200 #1

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 2.400 2.333 2.800 0.70
2 0.800 2.333 2.800 0.70
3 2.400 0.778 2.800 0.70
4 0.800 0.778 2.800 0.70

Page 50
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Workplane (kitchen) / Perpendicular illuminance (adaptive)

Workplane (kitchen): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 543 lx (Target: ≥ 500 lx), Min: 333 lx, Max: 646 lx, Min/average: 0.61, Min/max: 0.52
Height: 1.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 51
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

Page 52
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 25

Page 53
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / kitchen / Workplane (kitchen) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 54
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Summary

master bath

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (master bath) Perpendicular illuminance (adaptive) [lx] * 319 (≥ 300) 167 383 0.52 0.44
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L1160 1xLED48S/830 4799 45.0 106.6

Total via all luminaires 9598 90.0 106.6

Lighting power density: 14.85 W/m² = 4.66 W/m²/100 lx (Floor area of room 6.06 m²)

Consumption: 170 kWh/a of maximum 250 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 55
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Luminaire layout plan

master bath

Philips SM150C L1160 1xLED48S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 2.168 0.896 2.800 0.70
2 0.724 0.893 2.800 0.70

Page 56
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Workplane (master bath) / Perpendicular illuminance (adaptive)

Workplane (master bath): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 319 lx (Target: ≥ 300 lx), Min: 167 lx, Max: 383 lx, Min/average: 0.52, Min/max: 0.44
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 57
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 58
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 59
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Summary

reception

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (reception) Perpendicular illuminance (adaptive) [lx] * 301 (≥ 200) 178 368 0.59 0.48
Height: 0.800 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

6 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 14400 120.0 120.0

Lighting power density: 5.53 W/m² = 1.84 W/m²/100 lx (Floor area of room 21.69 m²)

Consumption: 470 kWh/a of maximum 800 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 60
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Luminaire layout plan

reception

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 2.834 0.958 2.800 0.70
2 2.838 2.888 2.800 0.70
3 2.843 4.817 2.800 0.70
4 0.938 0.963 2.800 0.70
5 0.943 2.892 2.800 0.70
6 0.948 4.822 2.800 0.70

Page 61
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Workplane (reception) / Perpendicular illuminance (adaptive)

Workplane (reception) / Perpendicular illuminance (adaptive)

Workplane (reception): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 301 lx (Target: ≥ 200 lx), Min: 178 lx, Max: 368 lx, Min/average: 0.59, Min/max: 0.48
Height: 0.800 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 62
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Workplane (reception) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 50

Page 63
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Workplane (reception) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 50

Page 64
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / reception / Workplane (reception) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 50

Page 65
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / Room 7 / Summary

Room 7

Clearance height: 2.800 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (Room 7) Perpendicular illuminance (adaptive) [lx] * 0.003 (≥ 500) 0.000 0.011 / 0.00
Height: 0.800 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Lighting power density: 0.00 W/m² = 0.00 W/m²/100 lx (Floor area of room 4.24 m²)

Consumption: 0 kWh/a of maximum 50 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 66
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Summary

shower

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (shower) Perpendicular illuminance (adaptive) [lx] * 142 (≥ 300) 127 153 0.89 0.83
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

1 DIALux - WT060C LED 36S840 PSU L1200 #1 3600 33.0 109.1

Total via all luminaires 3600 33.0 109.1

Lighting power density: 17.13 W/m² = 12.06 W/m²/100 lx (Floor area of room 1.93 m²)

Consumption: 64 kWh/a of maximum 100 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 67
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Luminaire layout plan

shower

DIALux WT060C LED 36S840 PSU L1200 #1

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 0.550 0.897 2.800 0.70

Page 68
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Workplane (shower) / Perpendicular illuminance (adaptive)

Workplane (shower): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 142 lx (Target: ≥ 300 lx), Min: 127 lx, Max: 153 lx, Min/average: 0.89, Min/max: 0.83
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Page 69
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Isolines [lx]

Scale: 1 : 10

Page 70
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

False colours [lx]

Scale: 1 : 10

Page 71
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / shower / Workplane (shower) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 10

Page 72
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Summary

toilet

Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70

Workplane
Surface Result Average (Target) Min Max Min/average Min/max

1 Workplane (toilet) Perpendicular illuminance (adaptive) [lx] * 238 (≥ 300) 191 276 0.80 0.69
Height: 0.000 m, Wall zone: 0.000 m

*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

# Luminaire Φ(Luminaire) [lm] Power [W] Luminous efficacy [lm/W]

2 Philips - SM150C L602 1xLED24S/830 2400 20.0 120.0

Total via all luminaires 4800 40.0 120.0

Lighting power density: 14.83 W/m² = 6.23 W/m²/100 lx (Floor area of room 2.70 m²)

Consumption: 77 kWh/a of maximum 100 kWh/a

The energy consumption quantities do not take into account light scenes and their dimming levels.

Page 73
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Luminaire layout plan

toilet

Philips SM150C L602 1xLED24S/830

No. X [m] Y [m] Mounting height [m] Maintenance factor


1 1.686 0.600 2.800 0.70
2 0.562 0.600 2.800 0.70

Page 74
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Workplane (toilet) / Perpendicular illuminance (adaptive)

Workplane (toilet) / Perpendicular illuminance (adaptive)

Workplane (toilet): Perpendicular illuminance (adaptive) (Surface)


Light scene: Light scene 1
Average: 238 lx (Target: ≥ 300 lx), Min: 191 lx, Max: 276 lx, Min/average: 0.80, Min/max: 0.69
Height: 0.000 m, Wall zone: 0.000 m

This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.

Isolines [lx]

Scale: 1 : 25

False colours [lx]

Scale: 1 : 25

Page 75
Project 0 21/10/2019

Site 1 / Building 1 / Storey 1 / toilet / Workplane (toilet) / Perpendicular illuminance (adaptive)

Value grid [lx]

Scale: 1 : 25

Page 76