AP5042 Alarm Panel Installation & User Manual

SAILOR®
by Thrane & Thrane

AP5042 Alarm Panel


Installation & User Manual

Copyright© Thrane & Thrane A/S


ALL RIGHTS RESERVED
2007, Thrane & Thrane A/S

Information in this document is subject to change without notice and


does not represent a commitment on the part of Thrane & Thrane A/S.

Document number: TT-98-125064-THR Revision: A

Release Date: 14th September 2007

1/21
AP5042 Alarm Panel Installation & User Manual

This page is intentionally left blank

2/21
AP5042 Alarm Panel Installation & User Manual

SAFETY SUMMARY
The following general safety precautions must be observed during all
phases of operation, service and repair of this equipment. Failure to
comply with these precautions or with specific warnings elsewhere in
this manual violates safety standards of design, manufacture and
intended use of the equipment.

Thrane & Thrane A/S assumes no liability for the customer’s failure to
comply with these requirements.

KEEP AWAY FROM LIVE CIRCUITS


Operating personnel must not remove equipment covers. Only
qualified maintenance personal must make component replacement and
internal adjustment. Under certain conditions, dangerous voltages may
exist even with the cable removed. To avoid injuries, always
disconnect power and discharge circuits before touching them.

3/21
AP5042 Alarm Panel Installation & User Manual

This page is intentionally left blank

4/21
AP5042 Alarm Panel Installation & User Manual

List of Contents:

1 Introduction ............................................................ 7
1.1 Initial Inspection ................................................................... 7
1.2 Storage .................................................................................. 7
1.3 Repacking for shipment ........................................................ 8
1.4 Additional manuals ............................................................... 8
1.5 Abbreviations........................................................................ 8
2 AP5042 Inmarsat-C Alarm Panel ......................... 9
3 Installation............................................................. 11
3.1 Mounting............................................................................. 11
3.1.1 Bracket Mount............................................................. 11
3.1.2 Flush mount ................................................................ 14
3.2 Grounding ........................................................................... 16
3.3 Connecting the AP5042 ...................................................... 16
3.3.1 AP5042 Power Connection ......................................... 16
3.3.2 AP5042 Network Address Configuration ................... 17
3.3.3 AP5042 Service Interface ........................................... 17
3.3.4 Connecting TT-3000E mini-C GMDSS System ......... 19
3.3.5 Connecting TT-3000C Inm-C GMDSS System.......... 19
3.4 AP5042 Initial check and configuration.............................. 19
4 Operation............................................................... 20
4.1 Sending Distress Alert ........................................................ 20
4.1.1 Acknowledgement – 3000C Inm-C GMDSS.............. 20
4.1.2 Acknowledgement – 3000E mini-C GMDSS ............. 20
4.2 Reception of Distress or Urgency ....................................... 20
4.3 Mute .................................................................................... 20
5 Appendix A: AP5042 Specifications ................... 21

5/21
AP5042 Alarm Panel Installation & User Manual

List of Figures:
Figure 1 AP5042 Inmarsat-C Alarm Panel..........................................10
Figure 2 Outline & dimensions - bracket mount .................................12
Figure 3 Drilling template - bracket ....................................................13
Figure 4 Outline and dimensions - flush mount...................................14
Figure 5 Drilling template - flush mount.............................................15
Figure 6 Flush mount assembly...........................................................15
Figure 7 RS232 Adapter Cable for Service Interface ..........................18
Figure 8 System detected, unit ready...................................................19

List of Tables:
Table 1 Pinout of "Power" connector on AP5042 ...............................16
Table 2 Node ID adressing ..................................................................17
Table 3 AP5042 Technical Specifications...........................................21

6/21
AP5042 Alarm Panel Installation & User Manual

1 INTRODUCTION
The AP5042 Inmarsat-C Distress Alarm Panel is used for remote
initiation of distress alert transmissions and visible and audible
indication of incoming distress and urgency messages on Inmarsat-C
GDMSS systems.

1.1 INITIAL INSPECTION


Inspect the shipping carton immediately upon receipt for evidence of
damage during the transport. If the shipping carton is severely
damaged or water stained, request the carrier's agent to be present
when opening the carton. Save the carton packing material for future
use.

WARNING
To avoid hazardous electrical shock, do not perform electrical
tests if there is any sign of shipping damage to any portion of
the outer cover. Read the safety summary at the front of this
manual before installation

Contents of the shipment should be as listed in the enclosed packing


list. If the contents are incomplete, if there is mechanical damage or
defect, or if the system components do not work properly, notify your
dealer.

After you unpack the system please:


• Inspect it thoroughly for damaged or loose components or loose
fittings.
• Inspect the cable harness for stress, loose or broken wires, or
broken cable ties.
• Examine all the components for loose or missing hardware.

1.2 STORAGE
The Alarm Panel AP5042 may be stored or shipped in temperatures
within the limits -40° C to +80° C. It is recommended that the system
is unpacked immediately on delivery.

7/21
AP5042 Alarm Panel Installation & User Manual

1.3 REPACKING FOR SHIPMENT


The shipping carton for the AP5042 Alarm Panel has been carefully
designed to protect the equipment during shipment. The carton and its
associated packing material should be used when repackaging for
shipment. Attach a tag indicating the type of service required, return
address and model number. Mark the carton FRAGILE to ensure
careful handling.

1.4 ADDITIONAL MANUALS

Ref. T&T number Title


[1] TT 98-107882 3020C installation manual

[2] TT 98-125065 AP5065 installation manual

[3] TT 98-122414 TT-3000E mini-C GMDSS


Installation Manual

[4] TT 98-125903 TT-3687A Alarm Panel Adapter


Installation & User Manual

1.5 ABBREVIATIONS
GMDSS Global Maritime Distress and Safety System

8/21
AP5042 Alarm Panel Installation & User Manual

2 AP5042 INMARSAT-C ALARM PANEL

The AP5042 Inmarsat-C Alarm Panel functions as a distress alarm


panel on a TT-3000E or a TT-3000C GMDSS system.

From the AP5042 Inmarsat-C Alarm Panel distress alerts can be


initiated. A distress alert is initiated by pressing the Distress button for
five seconds.

The AP5042 also has an indicator for reception of messages including


EGC with distress or urgent priority.

In case of the TT-3000E mini-C GMDSS System, the installation of a


distress alarm panels are mandatory.

In case of the TT-3000C Inm-C GMDSS System the installation only


one distress alarm panel is required as the TT-3020C has an alarm
button on the front.

AP5042 can be used as a supplement or replacement for TT-3042C


Remote Alarm/Distress Box.

Up to four AP5042 Inmarsat-C Alarm Panels can be connected to a


TT-3000E or a TT-3000C GMDSS System.

The design line of AP5042 matches that of the 5000 series radios from
Thrane & Thrane.

9/21
AP5042 Alarm Panel Installation & User Manual

Figure 1 AP5042 Inmarsat-C Alarm Panel

10/21
AP5042 Alarm Panel Installation & User Manual

3 INSTALLATION

3.1 MOUNTING
Two mounting options exist:
• Bracket
• Flush mount

3.1.1 BRACKET MOUNT


The outline and dimensions for a bracket mounted AP5042 are shown
in Figure 2.

11/21
AP5042 Alarm Panel Installation & User Manual

100

128

All dimensions are in millimetres

31.5

min. 150 60.5

Space for cable entry

Figure 2 Outline & dimensions - bracket mount

12/21
AP5042 Alarm Panel Installation & User Manual

The drilling template for the bracket is shown in Figure 3.

4 x ø 4.5

All dimensions are


in millimetres

11.6 86

109.2

Figure 3 Drilling template - bracket

13/21
AP5042 Alarm Panel Installation & User Manual

3.1.2 FLUSH MOUNT


The outline and dimensions for a flush mounted AP5042 are shown in
Figure 4.
120

Figure 4 Outline and dimensions - flush mount

The drilling template is shown in Figure 5 and the 3 dimensional


assembly drawing is shown in Figure 6.

14/21
AP5042 Alarm Panel Installation & User Manual

Figure 5 Drilling template - flush mount

Figure 6 Flush mount assembly

15/21
AP5042 Alarm Panel Installation & User Manual

3.2 GROUNDING
Connect a grounding wire between the ships structure and AP5042 by
using the dedicated grounding point found on the rear panel of the
alarm panel.

The grounding wire should have a cross section of at least 0.75mm2


and preferably the length should be kept below 1 meter.

3.3 CONNECTING THE AP5042


The connector marked “Power” is used for:

1) Connecting power to the internal electronics of the alarm panel


(the isolated RS485 interface is powered through connector “Inm-
C”).
2) Configuration of Node ID address on the RS485 network. As up to
four AP5042’s can be connected to the same cable, they need to
have their own unique address in the range 0-3.
3) Connection to the Service Interface.

The pin-out of the “Power” connector is shown in Table 1.

Male DSUB 9 pin connector marked “Power”


Pin Signal Remark
1 Node ID 1 GND GND for Node ID 1 selection
2 S-RX RS232 Service i/f RX (input)
3 S-TX RS232 Service i/f TX (output)
4 Node ID 1 Bus address selection pin
5 S-GND RS232 Service i/f GND
6 DC- Nominal voltage 24V DC. Can
7 DC+ operate from 8V to 32V DC.
8 Node ID 0 GND GND for Node ID 0 selection
9 Node ID 0 Bus address selection pin
Table 1 Pinout of "Power" connector on AP5042

3.3.1 AP5042 POWER CONNECTION

16/21
AP5042 Alarm Panel Installation & User Manual

Connect 24VDC between “Power” pin 6 (negative) and pin 7


(positive). Do not connect the shield of the power supply cable at the
alarm panel. It should be connected to ground at the source only.

The typical current drawn is 11mA@24VDC with the display lit as


shown in Figure 8. With full activity the maximum current will be
around 36mA@24VDC.

Note 1: The unit is internally protected against reverse polarity.

Note 2: The power supply is isolated from the box enclosure as well as
from the RS485 interface.

3.3.2 AP5042 NETWORK ADDRESS CONFIGURATION


The first AP5042 connected to the TT-3000E mini-C GMDSS System
only needs external power to operate. Subsequent AP5042’s need to
get the address pins strapped according to Table 2.

ID Node ID 1 Node ID 0
3 (1st AP5042) Floating Floating

2 (2nd AP5042) Floating Strap to Node ID 0


GND
1 (3rd AP5042) Strap to Node ID 1 Floating
GND
0 (4th AP5042) Strap to Node ID 1 Strap to Node ID 0
GND GND
Table 2 Node ID adressing

3.3.3 AP5042 SERVICE INTERFACE


Normally there is no need to access the RS232 service interface, but in
case it is necessary, the easiest method is to make a cable adapter as
shown in Figure 7.

17/21
AP5042 Alarm Panel Installation & User Manual

Figure 7 RS232 Adapter Cable for Service Interface

The terminal settings are 38400, N, 8, 1. If connected using Windows


HyperTerminal® or equivalent, the following will be seen during
power up:

Thrane & Thrane (c), Alarm panel, AP5042


Reset by power-up
Panel node ID :3
:

To get a list of available commands, type “help<cr>”.

18/21
AP5042 Alarm Panel Installation & User Manual

3.3.4 CONNECTING TT-3000E MINI-C GMDSS SYSTEM


Please refer to the TT-3000E mini-C GMDSS
Installation Manual [3].

3.3.5 CONNECTING TT-3000C INM-C GMDSS SYSTEM


Please refer to the TT-3687A Alarm Panel Adapter
Installation & User Manual [4].

3.4 AP5042 INITIAL CHECK AND CONFIGURATION


Pressing and holding the Test button will make all light indicators and
the alarm button flash. Pressing any other button while holding the
Test button, will sound the buzzer enabling verification of the buttons
and the audible indicator.

When an AP5042 is properly connected to the Inmarsat-C GMDSS


System, the indicator panel will be lit as shown in Figure 8.

Figure 8 System detected, unit ready.

19/21
AP5042 Alarm Panel Installation & User Manual

4 OPERATION
4.1 SENDING DISTRESS ALERT
Open the key cover and press the ‘DISTRESS’ button for minimum 5
seconds. The alert button and the selection annunciator for the active
unit flashes, and the buzzer sounds periodically.
When the distress alert transmission starts, the distress button and the
selection annunciator change to a constant light. This indication is also
given if a distress alert is initiated from the transceiver.

4.1.1 ACKNOWLEDGEMENT – 3000C INM-C GMDSS


When a distress acknowledgement has been received the distress
annunciator blinks once and the buzzer remains silent. Furthermore the
dimmer will be set to full light intensity.
When the distress acknowledgement has been read out or the distress
alert has been cancelled at the transceiver the annunciator and the
buzzer are switched off.

4.1.2 ACKNOWLEDGEMENT – 3000E MINI-C GMDSS


When a distress acknowledgement has been received the distress
annunciator changes to a slow cycle and the buzzer remains silent.
Furthermore the dimmer will be set to full light intensity.
When the distress acknowledgement has been read out or the distress
alert has been cancelled at the transceiver the annunciator and the
buzzer are switched off.

4.2 RECEPTION OF DISTRESS OR URGENCY


Reception of Distress or Urgency EGCs and messages are indicated by
a slowly flashing distress annunciator and a periodic sound from the
buzzer. Furthermore the dimmer will be set to full light intensity.

4.3 MUTE
Pressing the Mute button will silence the buzzer.

20/21
AP5042 Alarm Panel Installation & User Manual

5 APPENDIX A: AP5042 SPECIFICATIONS


Model AP5042 Inmarsat-C Alarm Panel
General Specifications The unit is in full compliance with the Inmarsat
CN114, IEC 60945 and Wheel Mark
specifications.
Dimensions (H x W x D) 100 mm x 100 mm x 32 mm.
(D = 41 mm from top of lid to back of DB9)
Weight 0.3 Kg
Mountings Bracket (standard)
Flush mount (optional)
Power requirements Floating DC.
Nominal voltage range is 24V.
Working voltage range is 8V to 32V.
Max current 36mA@24VDC

Connector 1 x DSUB9 Female.


1 x DSUB9 Male.
Fuse Internal automatic recovering poly fuse.
Temperature -25°C to 55°C operating,
-40°C to 80°C storage
Relative humidity 95% non-condensing at 40°C
Vibration operational Random vibrations: 5-20 Hz:0.005 g²/Hz
20-150 Hz:-3 dB/oct
(0.5 g rms.)
Sinusoidal vibrations: 2-15.8 Hz: 2.54 mm
peak ampl.
10-100 Hz: 1.0 g
peak acceleration
Vibration survival Random vibrations: 5-20 Hz:0.05g²/Hz
20-150 Hz:-3 dB/oct
(1.7g rms.)
Sinusoidal vibrations: 2-15.8 Hz:2.54 mm
peak ampl.
10-100 Hz: 1.0g
peak acceleration
Shock Half sine: 20g/11ms

Table 3 AP5042 Technical Specifications

21/21