www.tokaihit.

com

Incubation System for microscopes

TOKAI HIT Co., Ltd. Glass/Metal Heater for microscopes


306-1, Gendoji-cho, Fujinomiya-shi,
Shizuoka-ken, Japan 418-0074
Phone: +81 544 24 6699 FAX: +81 544 24 6641
E-mail: solution@tokaihit.com
■ Catalog printed August 2019
It is essential to read the instruction ■ Specififications and products in the catalog are subject to change without
manual when using this device. any obligation o the part of the distributor/manufacture.
■ Copying and replication of the contents of this images and pictures are
strictly prohibited. All Rights Reserved.
CA-NIGEN-EN-03
TOKAI HIT will …
Pursue the joy of inspiring our customers.
Manufacture products conscientiously.
Contribute to our community and society.

Temp., Humidity and CO2 control instrument for Time-Lapse Imaging Control temperature around a microscope

Incubation System for microscopes ThermoBox for microscopes


ThermoBox
Offers precision temperature, humidity and CO2 control Maintains a stable cell culturing environment at places where Temp. fluctuation occur.
for cell culture on a microscope. Enables to conduct short By enclosing the microscope, it also prevents the focus drift caused by the thermal expansion
and long term (more than 2 weeks) Time-Lapse Imaging. of the microscope itself.

Automatic Thermo-control System (For IVF and basic research)

Glass/Metal Heater for microscopes

Happiness for Cells, Success for Researchers. Ensures more accurate and reliable thermal control of the
specimens during the observation under a microscope.
Wide product range supports Biotechnology Science and
Add-on Options Solutions for variety of experiments. Industry. 10 year free-repair service for grass breakage
is adopted.

1 2
Incubation System for microscopes Chamber Components
Top Heater Easy Dish Fixing
Main heater which heats the specimen from the Stable and easier “Magnetic” fixing
upper surface. The transparent glass heater
prevents condensation and supports clear visibility.
Offer precision temperature, humidity and CO2 control
Strengthen glass applied
for cell culture on a microscope. Enables to conduct short Minimize the risk of glass breakage.
and long term (more than 2 weeks) Time-Lapse Imaging.
Dish Fixing Lid Even when the objective interferes with the bottom
of the dish, a spring type buffering mechanism
Easy setting of vessels with magnetic lid.

Features
prevents breakage of the dish/objective.
<Normal use> <When objective interference>

Dish Attachment
Supports 35mm dish, 50/60mm dish, chamber slide,
TEMP. Accurate and uniform temperature control slide glass and chambered coverglass by changing
one-touch mangetic holder.

TOKAI HIT Heating Quality Real-time Sample Feedback Regulation The lid is secured to

Tokai Hit's original Top Heater is proven to distribute heat Sterilized temperature sensor and magnetic lids make it easy
Access Ports the holder by magnets.

uniformly within the Chamber regardless of the type of vessels. to measure the temp. of culture media upon research needs. For temperature sensor and tubing for media
The controller regulates the heater based on the sensor signal exchange and drug delivery. Spring type
buffering mechanism
to keep sample at the target temp. accurately.
Bath Unit
Sample temp. against room temp. change Keeps distilled water and embedded Bath Heater Wreck Proof Lens Heater Cord
40
Sample Temp. heats it directly from beneath to generate Easy attachment and detachment with magnet relay
温度 35 37.0℃ high-humidity inside the Chamber unit. connector prevents breakage of objective revolver
30
Lens Heater and lens heater. It is also possible to lock by twisting
(℃)

25 Room Temp. the connector.


20 Prevents heat escaping from the sample to
Temp.

Uniform temperature distribution between wells and within a well. the objective. Especially effective under high
15
* In our measurement environment magnification, oil/water immersion observation.
10
* Can accommodate objectives up to φ40mm.
No interference by objective 5 Thin type and longer type are optional.
0
0 1 2 3 4 5 6 7 8
With unique Top Heater Heating Time
(hour)
※Inside the 35mm dish(Water:2ml)
regulation, the bottom of Chamber is
access-free for variety of objectives. Measure the actual temp. of
Stage Top Incubator Culture Results
(No metal plate at the bottom.) culture media with a attached
Sensor sterilized sensor. Attribute Name Details Period
Cultured Cell STO Embryo; fibroblast, mouse Over 5 days
HUM. Keeps high-humidity over 95% CO 2 Stable CO2 environment Cultured Cell PC12 Pheochromocytoma; adrenal gland, rat (male) Over 5 days
Keep the humidity level inside the chamber more than 95% The controller mixes 100%CO2 gas and the surrounding air Cultured Cell Hela Adenocarcinoma; crvix, human (female, 31 years) Over 5 days
by heating the distilled water in the Bath Unit. The internal automatically. Stable gas concentration inside the Chamber
humidifier minimizes the change in concentration of media is obtained by keep sending the mixed gas to the Chamber.
Primary Human Embryo Human embryo in vitro; form fertilization to hatching blastocyst over 7 days Over 7 days
by keeping the humidity inside the chamber. (※In case of controller with a built-in digital gas mixer) Primary Neurons Development of rat cerebral cortical neurons Over 4 days
CO2 concentration can be
adjustable from 5.0 to 20.0%. Primary Neural Stem Cells Proliferation of neural stem cells of 14-day-old rat embryo Over 7 days
100%CO2
Primary Neural Stem Cells Differentiation of rat neural stem cells to neurons and glial cells Over 7 days
Primary Hippocampal Neuron E18 rat hippocampal neurons, cultured in CO2 incubator for the first day Over 3 days
Chamber
100%CO2 Controller
Primary Cardiac Myocite Neonatal rat heart, fetal mouse, heart beat synchronization Over 3 days
Internal humidifier by Bath Heater gas cylinder (With built-in digital gas mixer)

REG. Prevent the focus drift


In addition to PID control, Continuous Current Control minimizes the focus drift generated by thermal expansion and
it also prevents light intensity change compared to the conventional ON/OFF control.

ON/OFF Control Continuous Current Control


(V) (V)
24 ON 24

±12V 11 Courtesy of Dr. Takeharu Nagai Paxillin actin tirf Courtesy of Dr. Kazuo Yamagata Courtesy of Dr. Hiroshi Kimura
±1V 9 The institute of Scientific and Industrial Simon Watkins and Claudette St. Croix Department of Genetic Engineering, Tokyo Institute of Technology
Research, Osaka University Center for Biologic Imaging, University of Pittsburgh Kindai University
OFF
0 (time) 0 (time)

Visit http://www.tokaihit.com for more details regarding our products. (Accessible from the QR code)

3 4
Cooling/Heating Chamber
/20~40℃(with oil/water immersion lens)
Sample temp.:15~40℃(with dry lens)

S ta n d a r d M o d e l Uniform Temperature Distribution


Normally, it is difficult to control around room temp. because there is not
big difference between room temp. and sample temp.. Since KRi series has
both cooling and heating function independently, it can control around room
25 years of our technical know-how is here. temp. precisely.
Heating(Sample:37℃) Cooling(Sample:20℃)

Happiness for Cells,


Success for Researchers 37.0 20.0

To support successful cell culturing with new features,


“STX” is our answer to the optimized incubating environment.
・Dish Attachment
For 35mm dish
Cooling/Heating Model KRiX-D35

Line-up KRiX series Heating only Model ATX-D


For slide glass, chamber slide, and chambered coverglass
For XY manual/motorized stage Cooling/Heating Model KRiX-CSG
With Chiller Unit Heating only ATX-CSG
WSKMX series
Model

Sample Feedback regulation *One of Dish Attachment(For Cooling/Heating)


is included as standard.
・Exclusive Sensor Lid
For small vessels use 35
For Nikon manual/motorized stage For well-plate and
Multi 35 50 60 Slide Chamber Chambered dish
mm Slide
Glass
Chamber
Slide
Chambered
Coverglass For 35mm dish
small vessels use
mm mm mm

Sample temperature:30~40℃
Well Plate dish dish dish Glass Slide Coverglass
(Included to the system as standard) Model LX-D35
With built-in digital gas mixer With built-in digital gas mixer STXGC-KRiX-SET
STXG-WSKMX-SET
Model For slide glass, chamber slide, and chambered coverglass
* for 100%CO2 gas cylinder use Model
(Included to the system as standard) Model LX-CSG
With built-in analog flow meter
With built-in analog flow meter Model STXFC-KRiX-SET
* for premixed gas cylinder use Model STXF-WSKMX-SET

TIZWX series
For upright microscope
For Nikon Ti/Ti2 exclusive piezo stage For well-plate and
small vessels use
Multi 35 50 60
mm mm mm Slide Chamber Chambered Sample temp.:37℃
Sample temperature:30~40℃ Well Plate dish dish dish Glass Slide Coverglass

With built-in digital gas mixer


* for 100%CO2 gas cylinder use Model STXG-TIZWX-SET UKX series
With built-in analog flow meter
* for premixed gas cylinder use Model STXF-TIZWX-SET For XY mechanical stage of upright microscope
For small vessels use 35 50 60
mm mm mm Slide
dish dish dish Glass

TIZBX series
With built-in digital gas mixer Model STXG-UKX-SET
For Nikon Ti/Ti2 exclusive piezo stage For small vessels use 35 50 60
mm mm mm Slide Chamber Chambered With built-in analog flow meter Model STXF-UKX-SET
Sample temperature:30~40℃ dish dish dish Glass Slide Coverglass

With built-in digital gas mixer


* for 100%CO2 gas cylinder use Model STXG-TIZBX-SET Opening/Closing Top Heater
With built-in analog flow meter
Model STXF-TIZBX-SET
Metal Top Heater with this function make it easy to set the object
* for premixed gas cylinder use
positioning before imaging.
・Dish Attachment ・Lens Heater

TIZSHX series PLAMX series For 35mm dish UKX-D35 Lens Heater UKX-LHD
*Lens Heater is included as standard
For 50/60mm dish UKX-D56
For Nikon Super Resolution N-SIM For MCL piezo stage, Prior NZ-200/400/500, For slide glass ・Lens Heater Options
UKX-SG
MCL PSZ200/400-S *Confirm the applicable stages Lens Heater Adapter UKX-LHA-□□
Sample temperature:30~40℃ *One Dish Attachment is included as standard
Sample temperature:30~40℃ Seal Ling TMU-□□
・Bracket *□□ contains the diameter of the objective
For small vessels use 35 50 60 For well-plate and 35 50 60 *One-set is included as standard
For manual stage UKX-STD
small vessels use
mm mm mm Slide Chamber Chambered Multi mm mm mm Slide Chamber Chambered
dish dish dish Glass Slide Coverglass Well Plate dish dish dish Glass Slide Coverglass
For Narishige fixed stage UKX-FNS
With built-in digital gas mixer With built-in digital gas mixer
* for 100%CO2 gas cylinder use Model STXG-TIZSHX-SET * for 100%CO2 gas cylinder use Model STXG-PLAMX-SET For Prior Z-deck UKX-ZD
For stages with 160×110mm opening UKX-SPC-3
With built-in analog flow meter With built-in analog flow meter
* for premixed gas cylinder use Model STXF-TIZSHX-SET * for premixed gas cylinder use Model STXF-PLAMX-SET For Nikon NI-S-E stage UKX-NI
*One-set is included as standard

5 6
Features
A fail-proof Incubation Simple Selections
Provides an easy, cleaver and accurate cellular environment. Easy add-on and expand the application. Now available with common accessories as standard.

Sample Feedback Mode SET model


Sterilized temperature sensor makes it easy to measure the sample temperature. The controller regulates the Top Heater setting value automatically All Dish Attachment and Dish Fixing Lid are included as standard. No more complicated selection.
based on the feedback from the sensor to keep sample at setting value accurately.
<SET components>
・Feedback Sensor
Sample temp. and room temp. ・Controller ・Chamber
40 Temperature sensor
Sample temp. Model Model Model
35 37.0℃ makes it easy to measure
STXG WSKMX TSU-200F
30 Sensor the sample temperature. With built-in digital gas mixer
or
Temp.(℃)

25 Room temp. ・Extension Wire ・USB cable


20
STXF
With built-in analog flow meter ・Software STX-APP ・Gas tube
15
・Dish Attachment ・Dish Fixing Lid
10 Model Model
5 ATX-W For well-plate LX-W For well-plate
Feedback mode can be used to determine the suitable setting value of
0
0 1 2 3 4 5 6 7 8 Top Heater in your actual room temperature/environment. ATX-A For ATX-D, ATX-CSG LX-D35 For 35mm dish
Time(hour)
※35mm dish with 2ml water
ATX-D For 35/50/60mm dish LX-D56 For 50/60mm dish

For slide glass, chamber slide For slide glass, chamber slide
ATX-CSG and chambered coverglass LX-CSG and chambered coverglass

Stress-Free Quality
Intuitive operation and varieties of new functions are included to support cell culturing without stress. Options
STX-APP(Software) Programmable Control Program Control
・Stage Adapter ・Dish Attachment

Simple operation of GUI will assist to The system includes the software

SAMPLE TEMP【℃】
45

visualize the preparation to setting and to program temp. and CO2/O2 40


37
lead your cell culture to success. concentration as this function allows 33

to expand the variety of experiment. 30


360 Model Model
25
60 120 180 240 300 Model TI2-ZILCS Model TI2-NA Model TI2-RA UNIV2-D35-2 UNIV2-D35-3
TIME【min】 For WSKMX For TIZWX・TIZBX For WSKMX For 35mm dish ×2 For 35mm dish ×3
TI2-S-SE-E, TI2-S-SS-E TI2-S-SE-E, TI2-S-SS-E TC-S-SR/SRF

Screen Capture Data Logging


Captures the PC screen to transfer Logs the temperature of each heaters,
images to smart-phones and tablets. sample temperature and gas
Model Model
Enables to see the image at home. concentration and saves the data in
CSV format. TID-ZILCS TID-NA MK-RA UNIV2-D35-4 UNIV2-D35-6
*PC must be connected with internet. Model Model Model
For 35mm dish ×4 For 35mm dish ×6
For WSKMX For TIZWX・TIZBX For WSKMX
TI-S-E/ER TI-S-E/ER TI-SR/SSR ※The dish attachment for 35mm dish ×5 is also available.

Add-on options
Digital Thermometer for research Reusable 35 mm dish *Cyto-cell Chamber (Auto-clavable) 【Assembly】

<Collaborative development with Prof. Takafumi Inoue, Waseda Univ.>


Precise temperature measurement is possible by using a thin Stainless top frame
sensor with Teflon covering and excellent chemical resistance. For a small For wide range
amount of medium observation 【Features】
1. Whole bottom observation is possble. O-ring
Model
No interferes with an objective even under
MC1000 <Components>
high magnification. Coverglass
Indicate temp. by 1 degree C/0.1 degree C units
・Digital Thermometer Thermo Prove(Sensor type) Model TSU-200F
・Thermo Probe(TSU-200F) 2. Running costs can be reduced.
2
K-type thermocouple Extension Wire(1.5m) Model HD1500
By changing the consumable parts, Stainless steel plate
the dish can be reused repeatedly.

SCC12-D35-SET SCC12-D35-SET 3. Observe with small amount of media.


IN/OUT Pipe for Media Exchange/Drug Delivery 35 mm Dish Spacer Model

Cover glass size:φ12.0 mm


Model

Cover glass size:φ25.0 mm Stainless bottom frame


※Consumable parts (Stainless steel plate,
Observation area:φ9.6 mm Observation area:φ21.0 mm
For media exchange and drug delivery with When using the 35mm dish from IWAKI, Greiner and Nunc, cover glass etc.) are also available.
incubation system for upright microscopes etc.. recommended to use Dish Spacer at the bottom of the dish.
Model 35DI-BS(left)
Model

PSBD1 Pipe OD 1.1mm For 35mm dish from IWAKI


PSBD1H Pipe OD 1.1mm(with side holes)
Model 35DGN-BS(right)
PSBD2 Pipe OD 2.1mm
For 35mm dish from 0.00 s 0.01 s 0.02 s 0.03 s 0.04 s 0.05 s 0.06 s 0.07 s
PSBD2H Pipe OD 2.1mm(with side holes) Greiner and Nunc Calcium imaging captured with Cyto-cell chamber. (Fura-2 Fluorescent image) Courtesy of:Prof. Takafumi Inoue,
Department of Life Science and Medical Bioscience,

7 Faculty of Science and Engineering, Waseda University


8
ECO Model
ECO Various upgrade options
Various functions can be upgraded by adding on to STX-ECO model depending on your requirements.

We wish to introduce great cost performance system STX-ECO model ( -E ) e.g. STXG-WELSX-E
with 25 years of our technical know-how.

ADD Dish Attachment & Fixing Lid ( -C )


Deliver High-Quality system to everyone! For slide glass, chamber slide and chambered coverglass use

Dish Attachment ( Model ATX-CSG ) + Fixing Lid ( Model LX-CSG )


Features
Simple ECO model ADD Real-time Sample Feedback Regulation ( -F )
Start time-lapsing without a hassle with our simple product selection and function.
Sample temp. and room temp.
40
Components Sterilized temperature sensor and magnetic lids make it
easy to measure the temp. of culture media upon research
35 Sample temp.
30
needs. The controller regulates the heater based on the
・Controller ・Chamber sensor signal to keep sample at the target temp. accurately. 25
・Temperature Sensor
Model Model 20

STXG WELSX 15
Room temp.
With built-in digital gas mixer Measure the actual temp. of 10
or culture media with a attached Model
5
STXF ・Extension Wire Sensor sterilized sensor.
0
With built-in analog flow meter ・Gas tube 0 1 2 3 4 5 6 7 8
Time(hour) ※Inside the 35mm dish(Water:2ml)

・Dish Attachment ・Dish Fixing Lid


Model Model

ATX-D For 35/50/60mm dish LX-D35 For 35mm dish ADD Software Control & compatible with NIS-Elements ( -A )
LX-D56 For 50/60mm dish
STX-APP (Tokai Hit original software) has intuitive operation and varieties of functions.
<Data Logging> <Program Control> <Screen Capture>

SAMPLE TEMP【℃】
45
40
37
33

Simple and high cell culture performance 30


25
60 120 180 240 300 360
Maintains a high-capability of cell culturing environment without complicated functions. TIME【min】

Logs the temperature of each heaters, The system includes the software Captures the PC screen to transfer
Heating Quality Temperature & Humidity sample temperature and gas to program temp. and CO2/O2 images to smart-phones and tablets.
concentration and saves the data in concentration as this function allows Enables to see the image at home.
Tokai Hit’ s original Top Heater is proven to Saves complicated function but keeps a stable thermal environment under a determinate room CSV format. to expand the variety of experiment. *PC must be connected with internet.
distribute heat uniformly within the Chamber, environment. The built-in Bath Unit keeps the humidity level inside the Chmaber more than 95%.
regardless of the type of vessels.
Media temperature Humidity inside a Chamber
Selection example
Dish Attachment e.g. STXG-WELSX-C
Humid【%】

( -C )
Temp【℃】

ADD
& Fixing Lid
37.0
e.g. STXG -WELSX -E ADD
Sample Feedback
Regulation ( -F )
STXG-WELSX-FA
TIME【min】 TIME【min】 Controller type Chamber type Components
Functions e.g.
ADD Sofware control ( -A )
Universal Design Prevent the focus drift
The external dimensions of the WELSX Chamber are 127.5×85mm, which are In addition to PID control, Continuous Current Control minimizes
same size as well-plates. It could be used on all stage that fits a well-plate. the focus drift generated by thermal expansion and it also prevents Options (Stage Adapter)
Glass protector light intensity change compared to the conventional ON/OFF control.

Continuous Current Control


Strengthen glass heater
(V)
24
Minimizes the risk of glass breakage
by adopting the strengthen glass and ±1V 11
9
the glass protector.
12
7.5
mm
Model WELSX-RA Model WELSX-TIM Model WELSX-TIP Model WELSX-K
mm 0 (time) For rectangular stage(with φ108mm) For TI-S-E/ER For Ti/Ti2 piezo stage For XY motorized stage
85
TI-SR/SFR/SSR (160×110mm opening)

9 10
ThermoBox for microscopes
ThermoBox
OPEN

Maintains a stable cell culturing environment at places where the temperature


fluctuation occur. By isolating the microscope from the envionment, it also prevents
the focus drift caused by the thermal expansion of microscope itself.
The combination use of Stage Top Incubator
and ThermoBox will increase the stability of

Features the cell culturing environment especially the


room temp. is unstable and the microscope is
close to air conditioner.

ThermoBox for Ti2

Line-up
Please select your suitable model from the list depending on your experiments or usage.
Microscope Stage Color Heater Model

Clear type
With heater Model TI2TB-E
Motorized stage No heater Model TI2TB-E-NH
<TI2-S-SE-E>
<TI2-S-SS-E> Black type With heater Model TI2TB-E-BK
with LED No heater Model TI2TB-E-BK-NH
Ti2
With heater Model TI2TB-M
Clear type
Manual stage No heater Model TI2TB-M-NH
<TC-S-SR/SRF>
Black type With heater Model TI2TB-M-BK
with LED No heater Model TI2TB-M-BK-NH
*Depending on the accessories (camera, stage etc.), the model may be a customized model. Please contact us for details.

Speci�ications
No duct required ・Dimensions of box:W820×D400×H290 (mm) Easy setup
・Dimensions of controller:W211×D305×H81 (mm)
Saves your working and setting space Anti-vibration heater ・Temp. setting range:Ambient~45℃(With Heater)
The panels are not separated one by one.
with built-in fan heaters. No air-duct It can be setup very easily by covering the
With anti-vibration design, the system can be
is required for heating. box from the top.
used under confocal without image drift.
<Front> <Side> <Top>

Available as a simple dark box 820

The black type is light shielding property and


can be used as a simple dark box.
290

400
Built-in heater

Anti-vibration
test movie

11 12
Add-on options
We offer the suitable solutions depending on your experiments.

Program fluidic control system Perfusion Media Exchange


Perfusion/Media exchange system
Perfusion, Media Exchange, Drug Delivery and Mixing can be easily Perfusion/Media exchange without removing a dish lid is possible.
programmed and done without disturbing your sample. Prevents media evaporation and contamination during long-term imaging.
Drug Delivery Mixing
<Media Exchange Lid>
Model PMD-D35 【Specification】
Continuous Perfusion:40μL/min~100μL/min Model KSX-Type1 *For STX/STR Chamber
※For STX/STR/INU Chamber Media Exchange volume:0.6ml~5.0ml Media IN Media OUT
※For 35mm dish Media Exchange Number:Maximum 10 times KS-Type1 *For INU Chamber
Drug Delivery:20μL~
System Image Controller size:W175×D175×H195 (mm) 【Components】 KS-PUMP <IN>
<Chamber(not included)

KS-PUMP <OUT>
・Peristaltic pumps ×2 KS-PUMP)・Media Exchange Lid LX-D35FME
<Controller> ・Diamond Insert KS-DIA)・Tube
<Chamber(not included)
> ・Glass bottle with air filter KS-BOTTLE
<Exclusive Dish Lid> *Media waste bottle is not included
Media/Drug OUT 【Specification】
Pump flow rate:0.05~0.145ml/min
(by using the attached tube)
Pump dimensions:W73×D208×H144 (mm)
Silicon tube:OD 3.0mm, ID 1.0mm(disposable)

1 2 <Glass bottle> Media IN Media OUT <Media waste bottle>


(not included)
3 4 KS-BOTTLE
<Media waste bottle>

Media/Drug IN 1 Drug delivery IN


2 Perfusion/Media Exchange IN
One-push drug delivery system
<Tube Heater> ∼
∼ Rapid and vibration-free drug delivery is possible.
The media/drug can be heated 3 Perfusion/Media Exchange OUT
Prevents media evaporation and contamination during long-term imaging.
and delivered to the Chamber
(Upper limit) <Start button>

4 Perfusion/Media Exchange OUT Model KSX-Type2 *For STX/STR Chamber


<Media container> (Lower limit)
KS-Type2 *For INU Chamber
■ Enables to mix the media and drug to be uniformly after the drug delivery. Connector OPEN
【Specification】
■ Setting of suction / supply liquid volume at a finer flow rate is possible. Dosage:20μℓ~100μℓ <Connector>

【Components】 ■ Regulates the system with TTL IN/OUT.     (Contact us if different dosage needed)
Controller dimensions:W100×D165×H116 (mm) Insert drug by pipette
・Controller ■ High-repeatability experiments are possible by keeping the media level evenly.
・Tube Heater Silicon tube:OD 3.0mm, ID 1.0mm
■ With a built-in tube heater, one fluidic control system can be completed with one system.     (Tube of the Dish side is disposable)
・Tubes(IN/OUT, with drug delivery fitting)
・Media containers(For perfusion, Media Exchange) ■ Supports general 35mm dish. <Chamber(not included)

Start drug delivery
※Media waste bottle is not included ■ Manages each user’ s program individually by using USB memory.

Digital Gas Mixer Media leakage detector


Digital Gas Mixer for Stage Top Incubator. You can choose depending on the usage gas cylinder. Detects the media leakage and stop the media pumps to prevent overflow
of media and damage to microscope.
For STX series
<Controller>

<Chamber for well-plate use> Shuts down electricity when

Model STX-CO2O2 Model STX-CO2 Model STX-O2 Model LM-UNIV2-D35 detecting media leakage

For low oxygen(Hypoxia) For CO2 concentration For O2 concentration


<Chamber for small vessels use> Pump OFF Pump OFF
O2 concentration:0.1~18.0%
CO2 concentration:5.0~20.0%
CO2 concentration:5.0~20.0%
Gas cylinder:100%CO2
O2 concentration:0.1~18.0%
Gas cylinder:100%N2
Model LM-UNIV-D35
Detect
Gas cylinder:100%CO2&100%N2 Dimensions:W115×D271×H250 Dimensions:W115×D271×H250
【Specification】 media leakage!
Dimensions:W160×D271×H250 *For STXF Controller *Must use with STX-CO2
Sensored Dish Attachment
Controller dimensions:W120×D175×H156 (mm)
For STX series <Exclusive Dish Attachment>

Model GM-8000 Model GM-4000 Model GM-2000


For low oxygen(Hypoxia) For CO2 conc.& flow rate For supplying fixed 5%CO2
<Chamber(not included)

O2 concentration:0.1~18.0% CO2 concentration:5.0~20.0% CO2 concentration:Fixed 5.0%
CO2 concentration:5.0~20.0% CO2 flow rate:50~200ml/min Gas cylinder:100%CO2
Gas cylinder:100%CO2&100%N2 Gas cylinder:100%CO2 Dimensions:W120×D175×H156
Dimensions:W160×D260×H187 Dimensions:W120×D175×H156

13 14
Glass/Metal Heater for microscope

Persues high-end “User-Friendliness”


Ensure more accurate and more reliable thermal control of the
specimens during the observation under a microscope.
Wide product range supports Biotechnology Science and Industry.

Realized downsizing and weight saving of cotroller compared


10 year free-repair service for glass breakage *1
Applied strengthen glass for the glass heater and with 10 year free-repair service for glass breakage.
to TP/TPX series. No more glass breakage and no more stopping your experiment.
SERIES Multi-function system supports temperature management in *1. Depending on the model

New Intelligent ThermoPlate various fields such as biological science.

Features
Compact Controller
Miniaturize the controller to as same size as smart-phone
It is very useful for space saving in the clean bench.

Controller dimensions:W85×D135×H30 (mm)


Size:232 (cm3) *82% decreased
Weight:170 (g) *62% decreased

In addition to flat placement(left), stand upright(center)and wall


hanging(right)are available with attached mounting hook depending
on the location of use. The mounting hook is durable design with a
load capacity of 2 kg and thin.
Reference movie:
<Flat placement> Glass strength test
<Stand upright> (Drop ball)
<Wall hanging>

Plate LED Indicator One-touch calibration


Plate LED Indicator visualizes the plate condition Easy calibration to set the suitable PID value on your
by not seeing the controller. usage environment is available with just one-touch.
Green LED lights up when the glass heater is ready. *Tokai Hit’s ThermoPlate is calibrated with the controller
 and the plate as a set to make the center of the plate temp.
 to be at 37.0℃ when the room temp. is 25℃±2℃ prior to
 the shipping.
Simple temp. measurement Continuous current control
Attached sterilized sensor can measure the actual In addition to PID control, Continuous Current Control
temperature and correct the plate suface temperature. minimizes the focus drift generated by thermal expansion Plate LED
Enable to monitor and log the data of temperature which and it also prevents light intensity change compared to
the sensor measures. the conventional ON/OFF control. Statement of LED Condition of the plate
The plate surface temp. is stable at the
Lights up setting temp..
ON/OFF control Continuous Current Control Blinks slowly
Calibration is running.
(1.0 sec. period)
(V) (V)
Blinks fast
24 ON 24 (0.2 sec. period)
An error occurred.

*Plate LED is attached to some major models.


±12V ±1V 11
9

OFF
0 (time) 0 (time)

Reference movie:ICSI

15 16
Line-up

Glass Plate <Components>


Microscope: Ni / Ci / 90i / 80i / 55i / 50i
Tokai Hit’s Glass Heater Standards Glass Plate ○
E1000/800/600/400/200
SERIES

Temp. setting range:Ambient - 60℃ (*Depending on the model)


Controller ○
External Sensor ○ OPTIPHOT-2 / LABOPHOT-2
Original clear glass heater maintains stable temperature. Support the needs in Extension Wire ○ Applicable stage: XY mechanical stage
different various fields such as Time-Lapse in low magnification and/or IVF field. Logging Software TEM ○
UPRIGHT Model TPi-SX
Glass thickness:0.5 (mm)
Plate dimensions:W142×D115 (mm)

Microscope: Ti2 / TS2R Microscope: Ti2 / Ti / TE2000 Heating area:W128×D95 (mm)

Applicable stage: XY manual stage(TC-S-SR/SRF) Applicable stage: Rectangular stage with 108mm round opening
Model TPi-TCSX Model TPi-108RX
Glass thickness:0.5 (mm) Glass thickness:0.5 (mm)
INVERTED Plate dimensions:W127.5×D85.5 (mm) Plate dimension:φ108 (mm) Microscope: SMZ25/18/1270 Microscope: SMZ1500/1000/800
Heating area:W115×D75 (mm) Heating area:W70×D70 (mm) Illumination base: P2-PB/DBL/DBF, P-DSL32/DSF32 Illumination base: C-DSD/DSS/BD
Model TPi-SMZ25X Model TPi-SMZSLX
Glass thickness:1.0 (mm) Glass thickness:1.0 (mm)

STEREO Plate dimensions:W251×D238 (mm) Plate dimensions:W254×D263 (mm)


Microscope: Ti2 / Ti Heating area:W185×D175 (mm) Heating area:W175×D185 (mm)
Applicable stage: Ti2 exclusive XY motorized stage(TI2-S-SE-E, TI2-S-SS-E)/ Ti exclusive XY motorized stage(TI-S-E/ER)

Model TPi-TIZGX
Glass thickness:0.5 (mm)
Plate dimensions:W159.5×D109.5 (mm) *In case the Nikon Piezo stage is not attached, Microscope: SMZ1500/1000/800
Heating area:W129×D87 (mm) TI2-NA(for Ti2)/ TID-NA(for Ti)is required separately. Illumination base: C-PS, C-05

Model TPi-SMZSSX Model TPi-SMZR


Glass thickness:1.0 (mm) Glass thickness:1.0 (mm)
Plate dimensions:W198×D269 (mm) Plate dimensions:φ180 (mm)
Microscope: TS2 Microscope: TMS / TMS-F Heating area:W162×D152 (mm) Heating area:W120×D120 (mm)
Applicable stage: XY manual stage(TS2-S-SM) Applicable stage: XY mechanical stage
Model TPi-TS2X Model TPi-TMSX
Glass thickness:0.5 (mm) Glass thickness:0.5 (mm)
Plate dimensions:W238×D122 (mm) Plate dimensions:W130×D90 (mm) Microscope: SMZ series UNIVERSAL
Heating area:W216×D94 (mm) Heating area:W103×D66 (mm) Illumination base: SMZ series illumination base For various types of illumination bases

Model TPi-SMZU Model TPi-UNIX


TPi-SMZ6 Glass thickness:1.5 (mm)
TPi-SMZ Plate dimensions:W435×D220 (mm)
Microscope: TS / TS-100 Glass thickness:1.0 (mm) Heating area:W400×D175 (mm)
Applicable stage: XY mechanical stage Plate dimensions: Leg adjustment:75~100 (mm)
SMZU:W260×D225 (mm)
Model TPi-TSX Model TPi-CKTS SMZ6: W200×D240 (mm)
*Temp. setting:Ambient~50℃

Glass thickness:0.5 (mm) Glass thickness:0.5 (mm) SMZ: W132×D195 (mm)

Plate dimensions:W130×D97.5 (mm) Plate dimensions:W150×D117 (mm)


Heating area:W101×D71.5 (mm) Heating area:W131×D95 (mm)
Large Glass Model TPi-W Model TPi-WL
Type Glass thickness:1.5 (mm) Glass thickness:1.5 (mm)
Plate dimensions:W230×D180 (mm) Plate dimensions:W310×D220 (mm)
Heating area:W180×D140 (mm) Heating area:W250×D170 (mm)

Applied strengthen glass and with


10 year free-repair service for glass breakage

17 18
Metal Plate Cooling/Heating Plate <Components>
For oil/water immersion objective and SERIES
Best for observing yeast, plants, marine samples, Metal Plate with a hole ○
SERIES

high-magnification objective imaging <Components> cultured cell, C. elegans and/or Planarian, etc. Controller ○

Temp. setting range:Ambient - 60℃ Metal Plate with a hole ○


Temp. setting range:4℃ - 60℃
External Sensor ×
Controller ○ Extension Wire ×
Focus drift is caused by thermal expansion from the ordinaly ON/OFF regulation. External Sensor ○ With electronic cooling element (Peltier module) and original control system, Logging Software TEM ×
Tokai Hit is applying Continuous Current Control regulation as standard to minimize focus drift. Extension Wire ○ it allows responsive cooling and heating regulation. Chiller Unit ○
Logging Software TEM ○
Effective for controlling the sample temp. around room temp.
Microscope: Ti2 / TS2R Microscope: Ti2 / Ti / TE2000 37℃ Cultured Cell
Usually, it is difficult to control the temperature around room temperature because of
Applicable stage: XY manual stage(TC-S-SR/SRF) Applicable stage: Rectangular stage with 108mm round opening the small temperature difference between the room temperature and the sample temperature.
28℃ Zebrafish
Model TPi-TCSH26 Model TPi-108RH26 However, Tokai Hit Cooling/Heating Plate has both cooling and heating functions and
can control the temperature around the room temperature acculately without any
Plate dimensions:W127.5×D85 (mm) Plate dimension:φ108 (mm)
25℃ Drosophila
change-over switch.
With a hole (φ26mm) With a hole (φ26mm)
INVERTED 20℃ C. elegans It also can be used for controlling activation of the common samples which a normally cultured at
37.0 degree C by lowering the temperature or observe expressions of samples at each temperature.

Microscope: Ti2 / Ti
Microscope: Ti2 / TS2R
Applicable stage: XY manual stage(TC-S-SR/SRF)
Applicable stage: Ti2 exclusive XY motorized stage(TI2-S-SE-E, TI2-S-SS-E)/ Ti exclusive XY motorized stage(TI-S-E/ER)
<With Chiller Unit>
Model TPi-TIZH26 Model TP-CHTCS-C
Plate dimensions:W160×D110 (mm) *In case the Nikon Piezo stage is not attached,
With a hole (φ26mm) TI2-NA(for Ti2)/ TID-NA(for Ti)is required separately. INVERTED Plate dimensions:W127.5×D85 (mm)
With a hole (φ20mm)

Microscope: Ti2 / Ti / TE2000


Rectangular stage with 108mm round opening
Options Applicable stage:

<With Chiller Unit> <With Chiller Unit>

Model TP-CH108RBF-C Model TP-CH108R-C


Plate dimension:φ108 (mm) Plate dimension:φ108 (mm)
With a hole (φ20mm) With a hole (φ20mm)
Lens Heater Tube Heater Hot Plate *Bottom flat type *Surface flat type

Model TPiE-LH Model TPiE-TH Model TPiE-SP/SPE


Temp. setting range:Ambient - 45℃ Temp. setting range:Ambient - 50℃ Temp. setting range:Ambient - 45℃ Microscope: Ni / Ci / 90i / 80i Upright microscope
Prevents heat loss from the sample especially A compact barrel-type heater. Simply wrap Light-weight and thin aluminum thermal plate Applicable stage: XY mechanical stage
when using oil/water immersion objective the media tubing for heating the media TPiE-SP :W482×D282 (mm) <With Chiller Unit>
and high-magnification objective. before inserting it to Chamber Unit. TPiE-SPE:W282×D232 (mm)
Model TP-CHS-C
Plate dimensions:W110×D110 (mm)
UPRIGHT With a hole (φ20mm)

Ultra Low-noise Plate


Suitable to maintain sample temp. during SERIES

potential mesurement in life science field


Temp. setting range:Ambient - 60℃ Microscope: Ti2 / Ti / TE2000 <With exclusive Chiller Unit>
Applicable stage: Rectangular stage with 108mm round opening Cool circulating water with sealed water.
Incorporate shield mechanism to reduce noise. Effective for long-term use.

Minimize noise from surface of the plate because Model TPiN-108NLR


the whole surface of the glass heater is connected Glass thickness:0.7 (mm)
to the earth. INVERTED Plate dimensions:φ108 (mm)
Heating area:W70×D70 (mm)

<Components>
Metal Plate with a hole ○
Microscope: Ni / Ci / 90i / 80i Upright microscope
Applicable stage: XY mechanical stage
Controller ○
External Sensor × Model TPiN-NLS
Extension Wire × Glass thickness:0.7 (mm)
Logging Software TEM × Plate dimensions:W142×D115 (mm)
UPRIGHT Heating area:W128×D95 (mm) Controller Plate
Temperature controller and pump for Cooling element (Peltier module) and a circulation flow
Noiseless type controller circulating water are built in. path for taking heat of the Peltie module are built in.

19 20
Customization
We are accepting customization according to the application and conditions. Please feel free to contact us.

2-channel controller (Option) Abundant experiences more than 100 products per year
2 plates can be controlled by TPiD controller. SERIES
Our experienced staff and engineers will accomodate your requests.
Every combination is possible

Ex1:Glass(for inverted)+ Glass(for stereo) Ex2:Glass(for stereo)+ Glass(for stereo)

+ +
TCSX SMZ25X UNIX UNIX

Model TPiD-TCSX-SMZ25X Model TPiD-UNIX-UNIX


Hearing Design Machining Assembly
Ex3: Metal(for inverted)
+ Lens Heater Ex4:Glass(for inverted)+ Hot Plate

TPiD Customizaion reference


+ +
TCSH26 LH TCSX SP ・Incubation system for MED64
Model TPiD-TCSH26-LH Model TPiD-TCSX-SP This device has been designed on the assumptions of an
experiment of electrophysiology. Enable the low noise
attribution under the cell culturing environment.

Entire Surface Heating Plate


Temp. control before/after observation With built-in digital gas mixer Model INUG2M-MED
Temp. setting range:Ambient - 50℃ INUM-MED-F1
SERIES
With built-in analog flow meter Model

Since the entire surface of the plate is heated, it can manage the temp. of the sample under observation as well as Temperature Controller only Model INUM-MED
the sample before/after observation. It is very useful when dealing with many samples.

Microscope: SMZ25/18/1270 <Temperature Distribution>


Illumination base: P2-PB/DBL/DBF, <Chamber>
P-DSL32/DSF32
Model TPiD-SMZ25DX ・KW / KD series
37.0 BOX-type ThermoPlate with a gas port.
Glass thickness:0.5 (mm)
Plate dimensions:W370×D248 (mm)
・For inverted microscope
Heating area:<Glass part> W128×D95 (mm)
・Setting temp.:Ambient~50℃(Plate temp.)

・Top Glass Heater prevents the condensation of the dish.

Enables to keep the ・Double Heater system(Top Heater/Stage Heater)


keeps the suitable sample temp.
vessels warm before
and after observation.

For well-plate use Model TPiD-KW


For 35mm dish use Model TPiD-KD
<TPiD-KW> <TPiD-KD>
ThermoPlate for Vitrification
For thawing process of frozen embryo
・Chamber for MEMS
Temp. setting range:Ambient - 60℃
SERIES

Customized attachments or spacers are available for your usage vessels.


Model TPiD-VITX Base dimensions:W435×D280 (mm) Glass thickness:0.5 (mm) In addition, attachments for patch clamp are also available.
Plate dimensions:W230×D148 (mm) Leg adjustment:75~100 (mm)
For various types of illumination bases
(Universal type) Heating area:W95×D128 (mm) ×2

37.0℃ 25℃ (room temp.)


・Built-in Heater
It is possible to customize heater for your system. We can manage the length of cable, corresponding temperature etc..
Dish Dish

Slide Slide *We have designed multiple attachments and/or fixing holders for various vessels like original PDMS, marketed
 dish etc. Please feel free to cantact Tokai Hit.

2ch controller
Designed to place your arms

21 22

You might also like